Search NASA⌕ Search

SEARCH · Search NASA

Results for “non-destructive techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neutron Grating Interferometry at the High Flux Isotope Reactor

Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.

Zhang, Yuxuan [ORNL] (ORCID:0000000200831408)↗

Screening and qualification methodology for SiC end plug processing methods

Deployment of SiC-ceramic-based fuel cladding for light water reactors requires a hermetic end plug–to–cladding joint that can withstand neutron irradiation during normal operation and maintain integrity during design-basis accidents. Reactor experiments have shown that some SiC composite tubes with SiC end plugs can retain hermeticity after irradiation. However, achieving consistent joint performance under irradiation remains a key challenge. Resolving this issue is essential to enable integral irradiation testing and to demonstrate fuel integrity under commercial-reactor irradiation conditions. This report aims to: (1) provide guidance for designing radiation-tolerant end plug joints for SiC cladding; (2) demonstrate experimental methods to detect processing defects that are unstable under neutron irradiation at light-water-reactor-relevant temperatures and doses; and (3) outline a step-by-step approach for designing and conducting reactor experiments to screen joining methods. The resulting data will be used to improve joint processing and to define critical defect types and sizes that must be detected and eliminated through non-destructive evaluation for quality assurance. Based on prior irradiation experiments at the High Flux Isotope Reactor, differential swelling among the cladding, bonding layer, and end plug was identified as an underlying mechanism for irradiation-induced joint degradation. Accordingly, this effect must be considered in the design of radiation-tolerant joining techniques. In this work, miniature SiC end plug joint specimens irradiated during the previous project were analyzed using X-ray computed tomography to characterize the joint microstructure. Digital volume correlation of the tomography data quantified radiation-induced microstructural changes and enabled evaluation of defect-related risks. Finally, ongoing neutron irradiation efforts using larger specimen volumes are presented. These efforts aim to statistically assess joint performance and to build a microstructure–performance (e.g., leak-tightness) dataset to inform processing improvements and quality control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Non-destructive structural characterization of graphite components using mechanical resonance and deep learning

As compared to conventional nuclear reactors, microreactors have the potential to significantly reduce construction timelines and capital costs, decreasing the barriers for advanced nuclear reactor technologies. However, the lower power output of these microreactors (typically < 20 MWe) creates challenging economics if operation and maintenance costs cannot be sufficiently reduced. The compact size of these designs presents an opportunity for comprehensive in-situ structural health monitoring to provide real-time feedback in order to reduce operational costs associated with maintenance and downtime. Many microreactor concepts use graphite for both in-core neutron moderation and as a structural material, which has typically required some form of periodic and laborious inspection. This report provides a description and assessment of recent work with graphite to couple acoustic-based experimental measurements and characterization with machine learning models to mature structural health monitoring capabilities and generate benefits for the nuclear microreactor industry. With resilient embedded sensors in development in other programs funded by the US Department of Energy’s Office of Nuclear Energy and elsewhere, the work described herein builds upon previously funded efforts to mature non-destructive testing technology that relates measured vibrational signatures to structural changes, using a combination of new experimental measurements and machine learning processing. Building on past successful demonstrations of predictive workflows to identify structural changes in a hexagonal stainless steel test article with excellent acoustic propagation, we first performed baseline characterization on graphite samples with canonical geometries to ensure compatibility and confidence in the applied techniques for a material with distinctly different mechanical properties. In contrast to efforts in previous years, we worked exclusively with unidirectional vibration data that is more comparable to those expected from the existing embedded sensor technologies which are suitable for deployment in a reactor setting. Established acoustic and modern machine-learning-based characterization approaches were applied to the resulting datasets from these simple geometries. Both approaches were found to be highly capable of detecting even small geometric irregularities amongst nominally identical samples. As such, we then moved to testing these approaches for detection of artificial local stress perturbations introduced into a more complex geometry: a hexagonal block with drilled holes. A main outcome of this work is that a generalizable ML workflow can be used to detect and predict the characteristics of small artificial anomalies in a graphite component with a relevant geometry. While this work was performed using surficial vibration data, we expect the approach to be flexible and viable for other monitoring scenarios, such as those with different arrangements or types of sensor arrays. As compared to previously funded efforts, an existing ML workflow based on neural networks was enhanced through the addition of recently developed Fourier neural operators. As applied to previously collected and new vibration datasets, prediction accuracies of anomaly characterizations were greatly improved with minimal added computational cost. As trained on small durations of vibration data (tens of seconds) collected over a realistic number of locations, the model was able to reliably determine the presence of a subtle stress anomaly and begin to provide location estimates. Such an approach is likely to be viable for more relevant reactor damage scenarios for graphite components, such as progressive crack growth or creep.

36 MATERIALS SCIENCE↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗

Pattern-enhanced Resonant Soft X-ray Scattering for Operando monitoring of electrochemical solid-liquid interfaces

Unveiling interfaces at sub-nanometer scales is essential for advancing the understanding of complex chemical transformations. However, characterizing solid-liquid interfaces with high dimensional sensitivity and temporal resolution remains challenging, due to their dynamic nature and inaccessibility by conventional probes. Here we present an approach, Pattern-enhanced Resonant Soft X-ray Scattering, to overcome the challenges. Rooted in a “sample-as-optics” philosophy, this technique utilizes precisely engineered line-grating nanopatterns to modulate near-field X-ray illumination, coherently enhancing scattering signals from the line-gratings. We implement the method using Ni line-grating nanopatterns in electrochemical water oxidation. The periodic nanostructures serve as diffractive optical elements to reveal the Ni oxidation gradients and structural dynamics at the electrode-electrolyte interfaces. Finite-element simulations corroborate the observed trends by modeling variations in compositions and structures during electrocatalysis. Through integrating advanced sample design with coherent wave nature of soft X-rays, our approach opens accessible pathways to operando exploring chemical evolution and sub-nanometer dimensional variations simultaneously in electrochemical systems. This non-destructive method is efficient and element-specific, making it valuable for probing chemical and dimensional dynamics with appropriate modeling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting (SC) circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in SC films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu–Shiba–Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

metal/substrate interlayer↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗

Quasiparticle spectroscopy in tantalum films with different Ta/sapphire interfaces

One of the crucial aspects of current research in quantum information science is the identification and control of loss mechanisms in superconducting circuits. Although microwave measurements directly quantify device performance, additional techniques that probe quasiparticle excitations in superconducting films are needed to understand the microscopic mechanisms underlying dissipation and decoherence. Here, we present results from quasiparticle spectroscopy of Ta/sapphire films by measuring the Meissner-state magnetic susceptibility using a precision frequency-domain resonator specifically designed for thin films. We find direct evidence for additional low-energy excitations in samples with lower internal quality factors. These excitations are consistent with deep subgap states due to two-level systems, Yu-Shiba-Rusinov states near the gap edge, and perhaps other pair-breaking mechanisms. The developed non-destructive frequency-domain quasiparticle spectroscopy is a valuable addition to the quantum materials toolbox.

Moirangthem, Bicky Singh [Ames Lab; Iowa State U.]↗

Deep learning‑based metal artefact reduction in X-ray computed tomography of TRISO fuel compacts

TRISO (TRi-structural ISOtropic) – compact-type micro-particle fuels – are next generation nuclear fuel compacts designed with safety in mind. Structural integrity and characterisation before and after irradiation are important to determine the performance of the fuel compacts under real reactor conditions. X-ray computed tomography can be an important tool for non-destructive evaluation of these fuel compacts. The fuel particles are highly attenuating for X-rays which creates metal artefact, rendering the images unusable. Our artefact correction can mitigate these artefacts significantly. The proposed method works by first segmenting highly-attenuating structures (metal) and forward projecting to localise the source of artefacts in the projection domain, then, using a traditional or U-net-based deep learning architecture, contextually interpolating those regions to remove the artefacts. Finally the reconstruction from the modified projection is fused with the segmented metal. The proposed method shows a significant improvement in the image quality while significantly reducing the reconstruction time compared to the standard technique.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Advancing Reel-to-Reel Inspection Techniques for Long HTS Conductors: Comparison and Innovations

The continuous advancement of high-temperature superconductor (HTS) technologies has greatly accelerated the development and deployment of HTS applications. Among the critical tools supporting these advancements are reel-to-reel (R2R) critical current (I c ) measurement techniques, which are extensively used by both manufacturers and end users to characterize long-length REBCO conductors. These techniques play a vital role in quality assurance and quality control (QA/QC), ensuring the reliability and performance of HTS conductors and applications throughout the production cycle. We have developed a range of in-house devices for R2R measurements at the University of Houston and Princeton Plasma Physics Laboratory. These include one-dimensional (1D) scan using a magnetic circuit (MC) and two-dimensional (2D) magnetic field mapping systems based on scanning probe array microscope (SPAM) or scanning probe microscopy (SPM). Each technique offers distinct advantages: the MC system provides ultra-fast scanning speeds, ideal for rapid inspection in large-scale industrial production; the high-resolution SPM delivers detailed insights for conductor research and development; and the SPAM, with its simpler mechanical setup, can be upgraded for higher field and lower temperature conditions with a balanced 2D resolution. Here we compared the magnetization and detection capabilities of these techniques through experiments on rare-earth barium copper oxide (REBCO) coated conductor samples, with data analysis supported by numerical simulations. Based on our comprehensive comparative studies, we propose enhancements for each measurement system and provide guidelines for selecting the optimal technique combinations to meet specific application requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchrotron-based diffraction-enhanced imaging and diffraction-enhanced imaging combined with CT X-ray imaging systems to image seeds at 30 keV

Utilized the upgraded Synchrotron-based non-destructive Diffraction-enhanced imaging and Diffraction-enhanced imaging coupled with CT X-ray imaging systems to image the chickpea seeds, to enhance the contrast in plant root architecture, visibility of fine structures of root architecture growth and some aspects of physiology at acceptable level. DEI-CT images were acquired with 30 keV synchrotron X-rays. A series of DEI-CT slices were assembled together, to form a 3D data set. DEI-CT images explored more structural information and morphology. Noticed detailed anatomical, physiological observations, and contrast mechanisms. Furthermore, with these systems, some of the complex plant traits, root morphology, growth of laterals and subsequent laterals can be visualized directly.

36 MATERIALS SCIENCE↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

Monte Carlo N-Particle Transport Performance of Predicting Digital Radiographic IQI Inspection

The identification of porosity, geometric noncompliance, and other defect types are critical to the qualification of materials and components. X-ray radiographic nondestructive testing is a common industrial inspection method for process quality control and component qualification and certification. Digital radiography provides a quick and efficient alternative when compared to traditional film-based inspection. The quality of radiographic inspection is dependent on equipment specifications, such as the source spot size and detector pixel size, and the specific parameters selected for use for the radiographic technique. To evaluate if an x-ray system and technique is sufficient for a given requirement, a radiographic image quality indicator (IQI) can be used. Radiographic IQIs in hard to machine materials or hard to manufacture defects can be time consuming and expensive to manufacture. This study was conducted to evaluate current Savannah River National Laboratory (SRNL) x-ray imaging systems with a custom tantalum IQI and using Monte Carlo simulations to predict the performance of future systems. The tantalum IQI was tested using a Siefert Isovolt 420 keV x-ray tube with a Perkin Elmer XRD 1611 flat panel with 100-micron pixels. Using the Monte Carlo N-Particle transport software, the radiographic tally was used to simulate the photon flux through an identical tantalum IQI. These simulations provided a benchmark as to the best theoretical identification on a given system using our tantalum IQI. The simulations were refined to match SRNL’s current systems’ noise levels, leading to confidence in their ability to predict the performance of other systems that may be purchased and deployed in the future at the Savannah River Site. Future studies will be conducted to prove this research can be extended to artificially evaluate the ability for systems to identify critical defect sizes through x-ray radiographic inspection, drastically reducing the cost and time burdens of producing high-fidelity radiographic test articles.

digital X-ray radiography↗

Non-destructive electrochemical diagnosis of failure mechanisms in aqueous zinc batteries

The early detection of secondary reactions that affect the life and performance of zinc manganese oxide batteries requires a shift from conventional time-consuming and often destructive procedures to rapid lifetime-predictive techniques. In this work, an electrochemical approach is employed to elucidate independent signatures for four common types of failure mechanisms in zinc manganese dioxide (Zn||MnO2) batteries—namely, the loss of zinc inventory, the loss of active material at the cathode, electrolyte depletion, and increased cell impedance. Our findings, specific to coin cell configurations, reveal that each induced failure mechanism can be distinctively modeled and identified based on responses from the rest voltage and columbic-efficiency data for prompt detection. For instance, electrolyte depletion response manifests a distinctive abrupt (>80 %) decrease in columbic efficiency (CE) and charge-rest voltage (Vc) while the discharge-rest voltage remained constant at ~1.3 V. Furthermore, electrolyte rejuvenation of the cell increased the CE to >95 % and restored Vc from ~0.3 to >1.7 V. Recovery experiments and reference performance tests demonstrated consistency between electrochemical descriptors and their associated failure mechanisms. Further, the outcomes of this work provide valuable insights and data models for some of the dominant failure mechanisms present in zinc manganese battery chemistries, which are beneficial to accelerated early-lifetime diagnosis and advancement of Zn batteries development.

25 ENERGY STORAGE↗

X-ray linear dichroic tomography of crystallographic and topological defects

Abstract The functionality of materials is determined by their composition 1–4 and microstructure, that is, the distribution and orientation of crystalline grains, grain boundaries and the defects within them 5,6 . Until now, characterization techniques that map the distribution of grains, their orientation and the presence of defects have been limited to surface investigations, to spatial resolutions of a few hundred nanometres or to systems of thickness around 100 nm, thus requiring destructive sample preparation for measurements and preventing the study of system-representative volumes or the investigation of materials under operational conditions 7–15 . Here we present X-ray linear dichroic orientation tomography (XL-DOT), a quantitative, non-invasive technique that allows for an intragranular and intergranular characterization of extended polycrystalline and non-crystalline 16 materials in three dimensions. We present the detailed characterization of a polycrystalline sample of vanadium pentoxide (V 2 O 5 ), a key catalyst in the production of sulfuric acid 17 . We determine the nanoscale composition, microstructure and crystal orientation throughout the polycrystalline sample with 73 nm spatial resolution. We identify and characterize grains, as well as twist, tilt and twin grain boundaries. We further observe the creation and annihilation of topological defects promoted by the presence of volume crystallographic defects. The non-destructive and spectroscopic nature of our method opens the door to operando combined chemical and microstructural investigations 11,18 of functional materials, including energy, mechanical and quantum materials.

Science & Technology - Other Topics↗