Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In Vivo Noninvasive Analysis of Human Forearm Muscle Function and Fatigue: Applications to EVA Operations and Training Maneuvers

Forearm muscle fatigue is one of the major limiting factors affecting endurance during performance of deep-space extravehicular activity (EVA) by crew members. Magnetic resonance (MR) provides in vivo noninvasive analysis of tissue level metabolism and fluid exchange dynamics in exercised forearm muscles through the monitoring of proton magnetic resonance imaging (MRI) and phosphorus magnetic resonance spectroscopy (P-31-MRS) parameter variations. Using a space glove box and EVA simulation protocols, we conducted a preliminary MRS/MRI study in a small group of human test subjects during submaximal exercise and recovery and following exhaustive exercise. In assessing simulated EVA-related muscle fatigue and function, this pilot study revealed substantial changes in the MR image longitudinal relaxation times (T2) as an indicator of specific muscle activation and proton flux as well as changes in spectral phosphocreatine-to-phosphate (PCr/Pi) levels as a function of tissue bioenergetic potential.

Fotedar, L. K.↗

Noninvasive Intracranial Volume and Pressure Measurements Using Ultrasound (Head and Spinal)

Prevention of secondary brain injuries following head trauma can be accomplished most easily when intracranial pressure (ICP) is monitored. However, current measurement techniques are invasive and thus not practical in the combat environment. The Pulsed Phase Lock Loop device, which was developed and patented by consultants Drs. Yost and Cantrell, uses a unique, noninvasive ultrasonic phase comparison method to measure slight changes in cranial volume which occur with changes in ICP. Year two studies included whole body head-up and head-down tilting effects on intracranial compliance and pressure in six healthy volunteers.

Hargens, Alan R.↗

Ultrasound as a Noninvasive Method to Assess Changes of Intracranial Volume and Pressure During Simulated Microgravity

Headaches are commonly experienced by astronauts in microgravity and by subjects undergoing head-down tilt (simulated microgravity on Earth). Exposure to microgravity probably elevates blood pressure and flow in the head which may increase intracranial volume (ICV) and pressure (ICP) and in turn cause headache. Due to the slightly compliant nature of the cranial vault and the encasement of brain and its vasculature within this vault, any increase of ICV will increase ICP and slightly distend the cranium. Previous studies document perivascular edema and increased ICP in rhesus monkeys during head-down tilt. Elevated ICP has also been reported in humans during head-down tilt. ICP measurements in healthy humans are rare because of the invasiveness of currently-available measurement techniques. Therefore, we proposed a noninvasive ultrasound technique to assess changes of ICV and JCP. The ultrasound principle is based on compliance of the cranial vault. A 450 kHz ultrasound stimulus is transmitted through the cranium by a transducer every 7.5-10 msec. The ultrasound wave enters the brain tissue, reflects off the opposite side of the cranium and is received by the same transducer. The detected wave is compared for phase quadrature (90 deg.to transmitted wave). Because the electronic circuitry of the device maintains a 90 deg. phase (phi), any alterations in the detected wave caused by an increase of ICV and ICP will be reflected as a change in the wave frequency. Phase shift is directly proportional to path length of the wave, DELTA x, which is expressed as DELTA x = phi lambda/2 pi where lambda is wavelength. Elevated ICV and ICP expand the cranial vault and increase path length of the wave (a measure of intracranial distance). Increased path length equals reduced frequency of the detected wave. Reduced frequency is then related to elevated ICP. This technique has potential uses for ICP studies of astronauts in space and head trauma patients on Earth.

Murthy, G.↗

Postural Effects on Intracranial Pressure as Assessed Noninvasively

This study was designed to investigate effects of whole body tilting on intracranial compliance and pressure in six healthy volunteers by using a noninvasive ultrasonic device. Subjects were randomly tilted up or down sequentially at 60 degree, 30 degree head-up, supine, and 15 degree head-down position for one minute at each angle. We measured arterial blood pressure with a finger pressure cuff and changes in intracranial distance with an ultrasonic device. The device measures skull movement on the order of micro-meter. Our ultrasound technique demonstrates that skull movement is highly correlated (r$(circumflex){2}$=0.77) with intracranial pressure variations due to cerebral arterial pulsation. The amplitudes of arterial pressure (r$(circumflex){2}$=0.99 and those of intracranial distance changes (r$(circumflex){2}$=0.87) associated with one cardiac cycle were inversely correlated with the angle of tilt. The ratio of pulsation amplitudes for intracranial distance over arterial pressure also showed a significant increase as the angle of tilt was lowered (p=0.003). Thus, postural changes alter intracranial compliance in healthy volunteers and intracranial volume-buffering capacity is reduced in head-down position.

Ueno, Toshiaki↗

Ocular static and dynamic light scattering: a noninvasive diagnostic tool for eye research and clinical practice

The noninvasive techniques of static and dynamic light scattering are emerging as valuable diagnostic tools for the early detection of ocular and systemic diseases. These include corneal abnormalities, pigmentary dispersion syndrome, glaucoma, cataract, diabetic vitreopathy, and possibly macular degeneration. Systemic conditions such as diabetes and possibly Alzheimer's disease can potentially be detected early via ocular tissues. The current state of development of these techniques for application to ophthalmic research and ultimately clinical practice is reviewed. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Review↗

Automated assessment of noninvasive filling pressure using color Doppler M-mode echocardiography

Assessment of left ventricular filling pressure usually requires invasive hemodynamic monitoring to follow the progression of disease or the response to therapy. Previous investigations have shown accurate estimation of wedge pressure using noninvasive Doppler information obtained from the ratio of the wave propagation slope from color M-mode (CMM) images and the peak early diastolic filling velocity from transmitral Doppler images. This study reports an automated algorithm that derives an estimate of wedge pressure based on the spatiotemporal velocity distribution available from digital CMM Doppler images of LV filling.

Non-NASA Center↗

Intracranial pressure dynamics during simulated microgravity using a new noninvasive ultrasonic technique

It is believed that intracranial pressure (ICP) may be elevated in microgravity because a fluid shift toward the head occurs due to loss of gravitational blood pressures. Elevated ICP may contribute to space adaptation syndrome, because as widely observed in clinical settings, elevated ICP causes headache, nausea, and projectile vomiting, which are similar to symptoms of space adaptation syndrome. However, the hypothesis that ICP is altered in microgravity is difficult to test because of the invasiveness of currently-available techniques. We have developed a new ultrasonic technique, which allows us to record ICP waveforms noninvasively. The present study was designed to understand postural effects on ICP and assess the feasibility of our new device in future flight experiments.

NASA Center ARC↗

Noninvasive assessment of left atrial maximum dP/dt by a combination of transmitral and pulmonary venous flow

OBJECTIVES: The study assessed whether hemodynamic parameters of left atrial (LA) systolic function could be estimated noninvasively using Doppler echocardiography. BACKGROUND: Left atrial systolic function is an important aspect of cardiac function. Doppler echocardiography can measure changes in LA volume, but has not been shown to relate to hemodynamic parameters such as the maximal value of the first derivative of the pressure (LA dP/dt(max)). METHODS: Eighteen patients in sinus rhythm were studied immediately before and after open heart surgery using simultaneous LA pressure measurements and intraoperative transesophageal echocardiography. Left atrial pressure was measured with a micromanometer catheter, and LA dP/dt(max) during atrial contraction was obtained. Transmitral and pulmonary venous flow were recorded by pulsed Doppler echocardiography. Peak velocity, and mean acceleration and deceleration, and the time-velocity integral of each flow during atrial contraction was measured. The initial eight patients served as the study group to derive a multilinear regression equation to estimate LA dP/dt(max) from Doppler parameters, and the latter 10 patients served as the test group to validate the equation. A previously validated numeric model was used to confirm these results. RESULTS: In the study group, LA dP/dt(max) showed a linear relation with LA pressure before atrial contraction (r = 0.80, p < 0.005), confirming the presence of the Frank-Starling mechanism in the LA. Among transmitral flow parameters, mean acceleration showed the strongest correlation with LA dP/dt(max) (r = 0.78, p < 0.001). Among pulmonary venous flow parameters, no single parameter was sufficient to estimate LA dP/dt(max) with an r2 > 0.30. By stepwise and multiple linear regression analysis, LA dP/dt(max) was best described as follows: LA dP/dt(max) = 0.1 M-AC +/- 1.8 P-V - 4.1; r = 0.88, p < 0.0001, where M-AC is the mean acceleration of transmitral flow and P-V is the peak velocity of pulmonary venous flow during atrial contraction. This equation was tested in the latter 10 patients of the test group. Predicted and measured LA dP/dt(max) correlated well (r = 0.90, p < 0.0001). Numerical simulation verified that this relationship held across a wide range of atrial elastance, ventricular relaxation and systolic function, with LA dP/dt(max) predicted by the above equation with r = 0.94. CONCLUSIONS: A combination of transmitral and pulmonary venous flow parameters can provide a hemodynamic assessment of LA systolic function.

NASA Discipline Cardiopulmonary↗

Noninvasive analysis of human neck muscle function

STUDY DESIGN. Muscle use evoked by exercise was determined by quantifying shifts in signal relaxation times of T2-weighted magnetic resonance images. Images were collected at rest and after exercise at each of two intensities (moderate and intense) for each of four head movements: 1) extension, 2) flexion, 3) rotation, and 4) lateral flexion. OBJECTIVE. This study examined the intensity and pattern of neck muscle use evoked by various movements of the head. The results will help elucidate the pathophysiology, and thus methods for treating disorders of the cervical musculoskeletal system. SUMMARY OF BACKGROUND DATA. Exercise-induced contrast shifts in T2 has been shown to indicate muscle use during the activity. The noninvasive nature of magnetic resonance imaging appears to make it an ideal approach for studying the function of the complex neuromuscular system of the neck. METHODS. The extent of T2 increase was examined to gauge how intensely nine different neck muscles or muscle pairs were used in seven subjects. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation was assessed to infer the pattern of use among and within individual neck muscles or muscle pairs. RESULTS. Signal relaxation increased with exercise intensity for each head movement. The absolute and relative cross-sectional area of muscle showing a shift in signal relaxation also increased with exercise load. Neck muscles or muscle pairs extensively used to perform each head movement were: extension--semispinalis capitis and cervicis and splenius capitis; flexion--sternocleidomastoid and longus capitis and colli; rotation--splenius capitis, levator scapulae, scalenus, semispinalis capitis ipsilateral to the rotation, and sternocleidomastoid contralateral; and lateral flexion--sternocleidomastoid CONCLUSION. The results of this study, in part, agree with the purported functions of neck muscles derived from anatomic location. This also was true for the few selected muscles that have been examined in human electromyographic studies. Neck muscle function and morphology can be studied at a detailed level using exercise-induced shifts in magnetic resonance images.

NASA Program Space Physiology and Countermeasures↗

Applications in Bioastronautics and Bioinformatics: Early Radiation Cataracts Detected by Noninvasive, Quantitative, and Remote Means

Human exploration of Mars is a key goal in NASA's exploration planning in the next 20 years. Maintaining crew health and good vision is certainly an important aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts because radiation exposure in space travel has the potential of accelerating the aging process (ref. 1). A patented compact device (ref. 2) based on the technique of dynamic light scattering (DLS) was designed for monitoring an astronaut's ocular health during long-duration space travel. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An Internet web-based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. The new technology detects cataracts very early (at the molecular level). Cataract studies onboard the International Space Station will be helpful in quantifying any adverse effect of radiation to ocular health. The normal lens in a human eye, situated behind the cornea, is a transparent tissue. It contains 35 wt % protein and 65 wt % water. Aging, disease (e.g., diabetes), smoking, dehydration, malnutrition, and exposure to ultraviolet light and ionizing radiation can cause agglomeration of the lens proteins. Protein aggregation can take place anywhere in the lens, causing lens opacity. The aggregation and opacification could produce nuclear (central portion of the lens) or cortical (peripheral) cataracts. Nuclear and posterior subcapsular (the membrane's capsule surrounds the whole lens) cataracts, being on the visual optical axis of the eye, cause visual impairment that can finally lead to blindness. The lens proteins, in their native state, are small in size. As a cataract develops, this size grows from a few nanometers (transparent) to several micrometers (cloudy). Ansari and Datiles have shown that DLS can detect cataracts at least two to three orders of magnitude earlier noninvasively and quantitatively than the best imaging (Scheimpflug) techniques in clinical use today (ref. 3).

Ansari, Rafat R.↗

PillCam(TradeMark), a Noninvasive Endoscopic Device for the Measurement of Gastrointestinal Motility Changes

Introduction: Bioavailability and effectiveness of drugs given by mouth are governed in part by gastrointestinal (GI) motility and function. Microgravity has been shown to decrease GI motility as indicated by a 3 fold increase in gastrointestinal transit time (GITT). The PillCam(TradeMark), an endoscopic camera embedded in a capsule, is a novel noninvasive and unobtrusive device that is used for the diagnosis of GI pathology. The purpose of this study is to evaluate the usefulness of PillCam(TradeMark) as an alternative to the Lactulose Breath Hydrogen Test (LBHT) for estimating GI motility. The sensitivity and applicability of this device for detection and estimation of the effect of promethazine, a deterrent, and caffeine, a prokinetic, on GI motility were also examined. Method: In this semi-randomized cross-over design study, six male and six female subjects were administered the following 4 treatments: PillCam(TradeMark) alone, PillCam(TradeMark)+Lactulose (10g), PillCam(TradeMark)+caffeine (200mg), and PillCam(TradeMark)+Promethazine (50mg). Results: GITT ranged between 1:24 and 7:52 hr:min. Lactulose did not alter GITT. A significant increase in GITT was noticed after administration of PMZ when compared to values from PillCam(TradeMark) treatment alone or PillCam(TradeMark)+Lactulose treatment. No difference in GITT after caffeine treatment was noticed. While there were no gender related differences in GITT after administration of PillCam(TradeMark) or with lactulose, a significant difference (p<.05) between genders was observed after promethazine administration with mean GITT higher in males (5:50 hr:min) than females (4:15 hr:min). Conclusion: The PillCam(TradeMark) capsule is applicable for the determination of GITT using time stamped GI images. It can be successfully used for the assessment of drug induced changes in GI motility and therefore, may be applicable for microgravity and analog environment studies on GI motility and function.

Vaksman, Zahman↗

Noninvasive Sensor for Measuring Muscle Metabolism During Exercise

The measurement of oxygen uptake (VO2) and lactate threshold (LT) are utilized to assess changes in aerobic capacity and the efficacy of exercise countermeasures in astronauts. During extravehicular activity (EVA), real-time knowledge of VO2 and relative work intensity can be used to monitor crew activity levels and organize tasks to reduce the cumulative effects of fatigue. Currently VO2 and LT are determined with complicated measurement techniques that require sampling of expired ventilatory gases, which may not be accurate in enclosed, oxygen-rich environments such as the EVA suit. The UMMS team has developed a novel near infrared spectroscopic (NIRS) system which noninvasively, simultaneously and continuously measures muscle oxygen tension, oxygen saturation, pH (pHm), and hematocrit from a small sensor placed on the leg. This system is unique in that it allows accurate, absolute measurement of these parameters in the thigh muscle by correcting spectra for the interference from skin pigment and fat. These parameters can be used to estimate VO2 and LT. A preliminary evaluation of the system s capabilities was performed in the NASA JSC Exercise Physiology Lab.

Soller, B. R.↗

"Zero-Mass" Noninvasive Pressure Transducers

Extremely lightweight, compact, noninvasive, rugged, relatively inexpensive strain-gauge transducers have been developed for use in measuring pressures of fluids in tubes. These gauges were originally intended for measuring pressures of spacecraft-propulsion fluids, but they are also attractive for use in numerous terrestrial applications especially those involving fluids that are extremely chemically reactive, fluids that must be isolated for hygienic purposes, fluids that must be allowed to flow without obstruction, and fluid-containing tubes exposed to severe environments. A basic pressure transducer of this type comprises one or more pair(s) of thin-film strain gauges integral with a tube that contains the fluid of interest. Following established strain-gauge practice, the gauges in each pair are connected into opposite arms of a Wheatstone bridge (see figure). Typically, each pressure transducer includes one pair (the active pair) of strain gauges for measuring the hoop stress proportional to the pressure of the fluid in the tube and another pair (the dummy pair) of strain gauges that are nominally unstrained: The dummy gauges are mounted on a substrate that is made of the same material as that of the tube. The substrate is welded to the tube at only one spot so that stresses and strains are not coupled from the tube into the substrate. The dummy strain gauges measure neutral strains (basically, strains associated with thermal expansion), so that the neutral-strain contribution can be subtracted out of the final gauge reading.

Hartley, Frank T.↗

A Noninvasive Miniaturized-Wireless Laser-Doppler Fiber-Optic Sensor for Understanding Distal Fingertip Injuries in Astronauts

During extra-vehicular activities (EVAs) or spacewalks astronauts over use their fingertips under pressure inside the confined spaces of gloves/space suits. The repetitive hand motion is a probable cause for discomfort and injuries to the fingertips. We describe a new wireless fiber-optic probe that can be integrated inside the astronaut glove for noninvasive blood perfusion measurements in distal fingertips. In this preliminary study, we present blood perfusion measurements while performing hand-grip exercises simulating the use of space tools.

Ansari, Rafat R.↗

Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms

A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present method is the presence versus the absence of reduced-amplitude zones (RAZs). In terms that must be simplified for the sake of brevity, an RAZ comprises several cycles of a high-frequency QRS signal during which the amplitude of the high-frequency oscillation in a portion of the signal is abnormally low (see figure). A given signal sample exhibiting an interval of reduced amplitude may or may not be classified as an RAZ, depending on quantitative criteria regarding peaks and troughs within the reduced-amplitude portion of the high-frequency QRS signal. This analysis is performed in all 12 leads in real time.

Schlegel, Todd T.↗

Optoelectronic Apparatus Measures Glucose Noninvasively

An optoelectronic apparatus has been invented as a noninvasive means of measuring the concentration of glucose in the human body. The apparatus performs polarimetric and interferometric measurements of the human eye to acquire data from which the concentration of glucose in the aqueous humor can be computed. Because of the importance of the concentration of glucose in human health, there could be a large potential market for instruments based on this apparatus.

Ansari, Rafat R.↗

Noninvasive Indicators of Intracranial Pressure Before, During, and After Long-Duration Spaceflight

Weightlessness induces a cephalad shift of blood and cerebrospinal fluid that may increase intracranial pressure (ICP) during spaceflight, while lower body negative pressure (LBNP) may provide an opportunity to caudally redistribute fluids and lower ICP. To investigate the effects of spaceflight and LBNP on noninvasive indicators of ICP (nICP), we studied thirteen crewmembers before and after spaceflight in seated, supine, and 15° head-down tilt postures, and at ~45 and ~150 days of spaceflight with and without 25 mmHg LBNP. We used 4 techniques to quantify nICP: cerebral and cochlear fluid pressure (CCFP), otoacoustic emissions (OAE), ultrasound measures of optic nerve sheath diameter (ONSD), and ultrasound-based internal jugular vein pressure (IJVp). On flight day 45, two nICP measures were lower than preflight supine posture (CCFP: mean difference -98.5 -nl [CI: -190.8 to -6.1 -nl], p = 0.037]; OAE: -19.7 degrees [CI: -10.4 to -29.1 degrees], p < 0.001), but not significantly different from preflight seated measures. Conversely, ONSD was not different than any preflight posture, whereas IJVp was significantly greater than preflight seated measures (14.3 mmHg [CI: 10.1 to 18.5mmHg], p < 0.001), but not significantly different than preflight supine measures. During spaceflight, acute LBNP application did not cause a significant change in nICP indicators. These data suggest that during spaceflight nICP is not elevated above values observed in the seated posture on Earth. Invasive measures would be needed to provide absolute ICP values and more precise indications of ICP change during various phases of spaceflight.

Jessica V. Jasien↗

Noninvasive acoustical property measurement of fluids

Methods for noninvasive determination of acoustical properties of flowing in pipes having a large ratio (>10) of pipe diameter to wall thickness, and in highly attenuating fluids are described. When vibrations are excited on the outer surface of the wall of a pipe, the resulting vibrations propagate directly through the wall in a normal direction and through the pipe wall as guided waves, appearing on the opposite side of the pipe. This dual path propagation through pipes, where guided waves take the circumferential path in the wall of the pipe and may interfere with the time of-flight measurement obtained from the direct path through the fluid, is at least in part resolved by subtracting the signal from the guided wave from the combined signal, thereby permitting improved observation of the direct path propagation through the fluid.

Sinha, Dipen N.↗