Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

"Zero-Mass" Noninvasive Pressure Transducers

Extremely lightweight, compact, noninvasive, rugged, relatively inexpensive strain-gauge transducers have been developed for use in measuring pressures of fluids in tubes. These gauges were originally intended for measuring pressures of spacecraft-propulsion fluids, but they are also attractive for use in numerous terrestrial applications especially those involving fluids that are extremely chemically reactive, fluids that must be isolated for hygienic purposes, fluids that must be allowed to flow without obstruction, and fluid-containing tubes exposed to severe environments. A basic pressure transducer of this type comprises one or more pair(s) of thin-film strain gauges integral with a tube that contains the fluid of interest. Following established strain-gauge practice, the gauges in each pair are connected into opposite arms of a Wheatstone bridge (see figure). Typically, each pressure transducer includes one pair (the active pair) of strain gauges for measuring the hoop stress proportional to the pressure of the fluid in the tube and another pair (the dummy pair) of strain gauges that are nominally unstrained: The dummy gauges are mounted on a substrate that is made of the same material as that of the tube. The substrate is welded to the tube at only one spot so that stresses and strains are not coupled from the tube into the substrate. The dummy strain gauges measure neutral strains (basically, strains associated with thermal expansion), so that the neutral-strain contribution can be subtracted out of the final gauge reading.

Hartley, Frank T.↗

A Noninvasive Miniaturized-Wireless Laser-Doppler Fiber-Optic Sensor for Understanding Distal Fingertip Injuries in Astronauts

During extra-vehicular activities (EVAs) or spacewalks astronauts over use their fingertips under pressure inside the confined spaces of gloves/space suits. The repetitive hand motion is a probable cause for discomfort and injuries to the fingertips. We describe a new wireless fiber-optic probe that can be integrated inside the astronaut glove for noninvasive blood perfusion measurements in distal fingertips. In this preliminary study, we present blood perfusion measurements while performing hand-grip exercises simulating the use of space tools.

Ansari, Rafat R.↗

Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms

A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present method is the presence versus the absence of reduced-amplitude zones (RAZs). In terms that must be simplified for the sake of brevity, an RAZ comprises several cycles of a high-frequency QRS signal during which the amplitude of the high-frequency oscillation in a portion of the signal is abnormally low (see figure). A given signal sample exhibiting an interval of reduced amplitude may or may not be classified as an RAZ, depending on quantitative criteria regarding peaks and troughs within the reduced-amplitude portion of the high-frequency QRS signal. This analysis is performed in all 12 leads in real time.

Schlegel, Todd T.↗

Optoelectronic Apparatus Measures Glucose Noninvasively

An optoelectronic apparatus has been invented as a noninvasive means of measuring the concentration of glucose in the human body. The apparatus performs polarimetric and interferometric measurements of the human eye to acquire data from which the concentration of glucose in the aqueous humor can be computed. Because of the importance of the concentration of glucose in human health, there could be a large potential market for instruments based on this apparatus.

Ansari, Rafat R.↗

Noninvasive Indicators of Intracranial Pressure Before, During, and After Long-Duration Spaceflight

Weightlessness induces a cephalad shift of blood and cerebrospinal fluid that may increase intracranial pressure (ICP) during spaceflight, while lower body negative pressure (LBNP) may provide an opportunity to caudally redistribute fluids and lower ICP. To investigate the effects of spaceflight and LBNP on noninvasive indicators of ICP (nICP), we studied thirteen crewmembers before and after spaceflight in seated, supine, and 15° head-down tilt postures, and at ~45 and ~150 days of spaceflight with and without 25 mmHg LBNP. We used 4 techniques to quantify nICP: cerebral and cochlear fluid pressure (CCFP), otoacoustic emissions (OAE), ultrasound measures of optic nerve sheath diameter (ONSD), and ultrasound-based internal jugular vein pressure (IJVp). On flight day 45, two nICP measures were lower than preflight supine posture (CCFP: mean difference -98.5 -nl [CI: -190.8 to -6.1 -nl], p = 0.037]; OAE: -19.7 degrees [CI: -10.4 to -29.1 degrees], p < 0.001), but not significantly different from preflight seated measures. Conversely, ONSD was not different than any preflight posture, whereas IJVp was significantly greater than preflight seated measures (14.3 mmHg [CI: 10.1 to 18.5mmHg], p < 0.001), but not significantly different than preflight supine measures. During spaceflight, acute LBNP application did not cause a significant change in nICP indicators. These data suggest that during spaceflight nICP is not elevated above values observed in the seated posture on Earth. Invasive measures would be needed to provide absolute ICP values and more precise indications of ICP change during various phases of spaceflight.

Jessica V. Jasien↗

Noninvasive Medical Diagnostics & Treatment Using Ultrasonics

In parallel to the industrial application of NDE to flaw detection and material property determination, the medical community has succesfully adapted such methods to the noninvasaive diagnostics and treatment of many conditions and disorders of the human body.

NDE noninvasive diagnostics destruction of blood c↗

Noninvasive stress testing - Methodology for elimination of the phonocardiogram

Measurement by systolic time intervals (STI) of cardiac responses requires extremely careful recording during actual stress test performance. Previous work indicated no significant changes in the pulse transmission time (PTT) during exercise and other challenges. Since external STI depend on the carotid pulse offset by the PTT as an aortic curve equivalent, stable PTT implies that timing of the carotid upstroke and the carotid incisura would respectively track the pre-ejection period and the aortic incisura. In ten subjects, STIs were recorded at supine rest, sitting, standing, during prompt and sustained squatting and during isometric and dynamic exercise. The results demonstrated the tracking of both points. Coefficients of correlation and of determination were uniformly high for all challenges except isometric handgrip (IHG). Since left ventricular ejection time is obtained directly from the pulse curve, with the exception of IHG, STI responses during stress testing can be measured without a phonocardiogram.

Spodick, D. H.↗

Noninvasive measures of bone bending rigidity in the monkey /M. nemestrina/

The in vivo bending rigidity and bone mineral content of monkey ulnae and tibiae were measured. Bending rigidity in the anteroposterior plane was measured by an impedance probe technique. Forced vibrations of the bones were induced with an electromechanical shaker, and force and velocity at the driving point were determined. The responses over the range of 100-250 Hz were utilized to compute the bending rigidity. Bone mineral content in the cross section was determined by a photon absorption technique. Seventeen male monkeys (Macaca nemestrina) weighing 6-14 kg were evaluated. Bending rigidity was correlated with the mineral content of the cross section, with a correlation coefficient of 0.899. Two monkeys were evaluated during prolonged hypodynamic restraint. Restraint produced regional losses of bone most obviously in the proximal tibia. The local bone mineral content declines 17 to 24% and the average bending rigidity declines 12 to 22%. Changes in bones leading to a reduction in mineral content and stiffness are discussed.

Young, D. R.↗

Noninvasive Fluid Level Sensor for Organometallic Sources

Two ultrasonic methods available for measuring level of organometallic liquid in stainless-steel (or other homogeneous solid) container. Methods require no disassembly or weighing of container. Commercially available ultrasonic flaw detectors, some of which have digital readouts and computer interfaces, used in techniques. Both methods used in crystal growth to determine level of liquids contained in sealed, opaque containers.

Gerdes, W.↗

Remote gate capacitance-voltage studies for noninvasive surface characterization

A measurement technique has been developed which allows noncontact capacitance-voltage measurements to be made using a gate electrode located remote from the semiconductor surface under study. With gate electrodes about 0.5 mm in diameter and gate to semiconductor separations of about 1500 A, it was possible to generate data entirely comparable to that obtained with integrated MIS structures but with the advantage that there was access directly to the free-semiconductor surface. This technique was applied to bulk single-crystal Si and InP samples.

Chang, R. R.↗

Cardiovascular adaptation to O-G (Experiment 294) - Instrumentation for invasive and noninvasive studies

Many astronauts returning from space have difficulties regulating blood pressure, some to the point of fainting during quiet standing. Experiment 294 was designed to study this and other cardiovascular effects of adaptation to microgravity and to understand the mechanisms behind it. To accomplish this several cardiovascular variables had to be measured accurately. Heart rate, blood pressure, cardiac output (blood pumped by the heart each minute), stroke volume (blood pumped by the heart with each beat), limb flow, limb compliance, heart size and central venous pressure all had to been recorded during various stresses to understand fully the adaptation to space and the readaptation to earth's gravity. Numerous pieces of equipment were used. Some were purpose-built for the Spacelab mission and others were derived from commercial hardware. Developing spaceflight hardware is challenging and costly, but can lead to significant new information in the unique environment of space.

Buckey, Jay C.↗

Measuring Intracranial Pressure And Volume Noninvasively

Ultrasonic technique eliminates need to drill into brain cavity. Intracranial dynamics instrument probes cranium ultrasonically to obtain data for determination of intracranial pressure (ICP) and pressure-volume index (PVI). Instrument determines sensitivity of skull to changes in pressure and by use of mechanical device to exert external calibrated pressure on skull. By monitoring volume of blood flowing into jugular vein, one determines change of volume of blood in cranial system. By measuring response of skull to increasing pressure (where pressure increased by tilting patient known amount) and by using cranial blood pressure, one determines intial pressure in cerebrospinal fluid. Once PVI determined, ICP determined.

Cantrell, John H.↗

Noninvasive Determination of Bone Mechanical Properties Using Vibration Response: A Refined Model and Validation in vivo

Accurate non-invasive mechanical measurement of long bones is made difficult by the masking effect of surrounding soft tissues. Mechanical response tissue analysis (MRTA) offers a method for separating the effects of the soft tissue and bone; however, a direct validation has been lacking. A theoretical analysis of wave propagation through the compressed tissue revealed a strong mass effect dependent on the relative accelerations of the probe and bone. The previous mathematical model of the bone and overlying tissue system was reconfigured to incorporate the theoretical finding. This newer model (six-parameter) was used to interpret results using MRTA to determine bone cross-sectional bending stiffness, EI(sub MRTA). The relationship between EI(sub MRTA) and theoretical EI values for padded aluminum rods was R(sup 2) = 0.999. A biological validation followed using monkey tibias. Each bone was tested in vivo with the MRTA instrument. Postmortem, the same tibias were excised and tested to failure in three-point bending to determine EI(sub 3-PT) and maximum load. Diaphyseal bone mineral density (BMD) measurements were also made. The relationship between EI(sub 3-PT) and in vivo EI(sub MRTA) using the six-parameter model is strong (R(sup 2) = 0.947) and better than that using the older model (R(sup 2) = 0.645). EI(sub MRTA) and BMD are also highly correlated (R(sup 2) = 0.853). MRTA measurements in vivo and BMD ex vivo are both good predictors of scaled maximum strength (R(sup 2) = 0.915 and R(sup 2) = 0.894, respectively). This is the first biological validation of a non- invasive mechanical measurement of bone by comparison to actual values. The MRTA technique has potential clinical value for assessing long-bone mechanical properties.

Roberts, S. G.↗

Noninvasive Determination of Bone Mechanical Properties using Vibration Response: A Refined Model and Validation in vivo

Accurate non-invasive mechanical measurement of long bones is made difficult by the masking effect of surrounding soft tissues. Mechanical Response Tissue Analysis (MRTA) offers a method for separating the effects of the soft tissue and bone; however, a direct validation has been lacking. A theoretical analysis of wave propagation through the compressed tissue revealed a strong mass effect dependent on the relative accelerations of the probe and bone. The previous mathematical model of the bone and overlying tissue system was reconfigured to incorporate the theoretical finding. This newer model (six-parameter) was used to interpret results using MRTA to determine bone cross-sectional bending stiffness, EI(sub MRTA). The relationship between EI(MRTA) and theoretical EI values for padded aluminum rods was R(exp 2) = 0.999. A biological validation followed using monkey tibias. Each bone was tested in vivo with the MRTA instrument. Postmortem, the same tibias were excised and tested to failure in three-point bending to determine EI(sub 3-PT) and maximum load. Diaphyseal Bone Mineral Density (BMD) measurements were also made. The relationship between E(sub 3-PT) and in vivo EI(sub MRTA) using the six-parameter model is strong (R(exp 2) = 0.947) and better than that using the older model (R(exp 2) = 0.645). EI(MRTA) and BMD are also highly correlated (R(exp 2) = 0.853). MRTA measurements in vivo and BMD ex vivo are both good predictors of scaled maximum strength (R(exp 2) = 0.915 and R(exp 2) = 0.894, respectively). This is the first biological validation of a non-invasive mechanical measurement of bone by comparison to actual values. The MRTA technique has potential clinical value for assessing long-bone mechanical properties.

Roberts, S. G.↗

Noninvasive Investigation of Bone Adaptation in Humans Cumulative Daily Mechanical Loading

Our Research Objective is to measure the spatial distribution of bone mass throughout the entire internal volume of a bone such as the human calcaneus or heel bone. Currently, x-ray computed tomography (CT) is the only practical three-dimensional imaging technology capable of measuring bone density within small contiguous volumetric regions of a bone. spectrum of energies in the x-ray beam producing the image. We have developed a computational method of correcting these errors, provided the x-ray spectrum is known or measured (Yan et al., 2000). Monitoring serial changes in volumetric bone density with age, disuse, exercise or A CT image contains measurement errors in bone density caused by the broad drug therapy also requires accurate image registration.

Whalen, Robert T.↗