Level of holographic noise in interferometry

The level of holographic noise expected to be observed in interferometric gravitational wave detectors such as GEO600 is reexamined. It is demonstrated that earlier estimates are based on assumed linear diffractive behavior of Planck radiation. Since nonlinear effects, such as self-focusing, are expected to appear at much lower energies, the expected level of holographic noise must be reduced by many orders of magnitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Generalized Residual Stress Inversion Technique

Residual stress is a common result of manufacturing processes, but it is one that is often overlooked in design and qualification activities. There are many reasons for this oversight, such as lack of observable indicators and difficulty in measurement. Traditional relaxation-based measurement methods use some type of material removal to cause surface displacements, which can then be used to solve for the residual stresses relieved by the removal. While widely used, these methods may offer only individual stress components or may be limited by part or cut geometry requirements. Diffraction-based methods, such as X-ray or neutron, offer non-destructive results but require access to a radiation source. With the goal of producing a more flexible solution, this LDRD developed a generalized residual stress inversion technique that can recover residual stresses released by all traction components on a cut surface, with much greater freedom in part geometry and cut location. The developed method has been successfully demonstrated on both synthetic and experimental data. The project also investigated dislocation density quantification using nonlinear ultrasound, residual stress measurement using Electronic Speckle Pattern Interferometry Hole Drilling, and validation of residual stress predictions in Additive Manufacturing process models.

42 ENGINEERING↗

Frequency stabilization via the mixed mode in three mode HeNe lasers

This paper describes a three mode HeNe laser frequency stabilization technique using the mixed mode frequency to obtain a fractional frequency stability of 2 x 10{sup -11}. The mixed mode frequency occurs due to optical nonlinear interactions with the adjacent modes at each of the three modes. In precision displacement interferometry systems, the laser source frequency must be stabilized to provide an accurate conversion ratio between phase change and displacement. In systems, such as lithography applications, which require high speed, high accuracy and low data age uncertainty, it is also desirable to avoid periodic nonlinearities, which reduces computation time and errors. One method to reduce periodic nonlinearity is to spatially separate the measurement and reference beams to prevent optical mixing, which has been shown for several systems. Using spatially separated beams and the proper optical configuration, the interferometer can be fiber fed, which can increase the interferometer's stability by reducing the number of beam steering optical elements. Additionally, as the number of measurement axes increases, a higher optical power from the laser source is necessary.

42 ENGINEERING↗

A Fourier transform method for Vsin i estimations under nonlinear Limb-Darkening laws

Star rotation offers us a large horizon for the study of many important physical issues pertaining to stellar evolution. Currently, four methods are widely used to infer rotation velocities, namely those related to line width calibrations, on the fitting of synthetic spectra, interferometry, and on Fourier transforms (FTs) of line profiles. Almost all of the estimations of stellar projected rotation velocities using the Fourier method in the literature have been addressed with the use of linear limb-darkening (LD) approximations during the evaluation of rotation profiles and their cosine FTs, which in certain cases, lead to discrepant velocity estimates. In this work, we introduce new mathematical expressions of rotation profiles and their Fourier cosine transforms assuming three nonlinear LD laws—quadratic, square-root, and logarithmic—and study their applications with and without gravity-darkening (GD) and geometrical flattening (GF) effects. Through an analysis of He I models in the visible range accounting for both limb and GD, we find out that, for classical models without rotationally driven effects, all the Vsin i values are too close to each other. On the other hand, taking into account GD and GF, the Vsin i obtained with the linear law result in Vsin i values that are systematically smaller than those obtained with the other laws. As a rule of thumb, we apply these expressions to the FT method to evaluate the projected rotation velocity of the emission B-type star Achernar (α Eri).

79 ASTRONOMY AND ASTROPHYSICS↗

Investigations of laser-induced damages in fused silica optics using x-ray laser interferometric microscopy

A novel x-ray laser (XRL) application, aimed at understanding the microscopic effects involved in formation of laser-induced damage in optical materials exposed to high-power sub-ns laser pulses, is presented. Standard fused silica substrates with permanent damage threshold below 20 J/cm{sup 2}, when irradiated by 438 nm laser pulses, were probed in situ by a neonlike zinc XRL at 21.2 nm. The probing beamline employed a double Lloyd's mirror x-ray interferometer, used in conjunction with an imaging mirror to achieve magnification of {approx}8. In conjunction with an array of in situ optical diagnostics, the main question addressed is whether the damage on the rear surface of the beamsplitter is transient or permanent. The second issue, examined by both the x-ray interferometric microscopy and the optical diagnostics, is whether a local rear-surface modification is associated with nonlinear effects such as self-focusing or filamentation of the damaging laser beam in the bulk.

36 MATERIALS SCIENCE↗

Chromatic dispersion effects in ultra-low coherence interferometry

We consider the properties of an interference signal shift from zero-path-difference position in the presence of an uncompensated dispersive layer in one of the interferometer arms. It is experimentally shown that in using an ultra-low coherence light source, the formation of the interference signal is also determined by the group velocity dispersion, which results in a nonlinear dependence of the position of the interference signal on the geometrical thickness of the dispersive layer. The discrepancy in the dispersive layer and compensator refractive indices in the third decimal place is experimentally shown to lead to an interference signal shift that is an order of magnitude greater than the pulse width. (interferometry)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Ultrafast high strain rate acoustic wave measurements at high static pressure in a diamond anvil cell

We have used sub-picosecond laser pulses to launch ultra-high strain rate ({approx} 10{sup 9} s{sup -1}) nonlinear acoustic waves into a 4:1 methanol-ethanol pressure medium which has been precompressed in a standard diamond anvil cell. Using ultrafast interferometry, we have characterized acoustic wave propagation into the pressure medium at static compression up to 24 GPa. We find that the velocity is dependent on the incident laser fluence, demonstrating a nonlinear acoustic response which may result in shock wave behavior. We compare our results with low strain, low strain-rate acoustic data. This technique provides controlled access to regions of thermodynamic phase space that are otherwise difficult to obtain.

36 MATERIALS SCIENCE↗

Mach-Zehnder interferometry with interacting trapped Bose-Einstein condensates

We theoretically analyze a Mach-Zehnder interferometer with trapped condensates and find that it is surprisingly stable against the nonlinearity induced by interparticle interactions. The phase sensitivity, which we study for number-squeezed input states, can overcome the shot noise limit and be increased up to the Heisenberg limit provided that a Bayesian or maximum-likelihood phase estimation strategy is used. We finally demonstrate the robustness of the Mach-Zehnder interferometer in the presence of interactions against condensate oscillations and a realistic atom-counting error.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density characterization of discharged gas-filled capillaries through common-path two-color spectral-domain interferometry

Electrically discharged plasma structures, typically several centimeters in length and sub-millimeter in diameter, have been applied to guide laser pulses in laser plasma accelerators and to focus ion and relativistic electron beams in compact, radially symmetric transport configurations. Knowledge of the on-axis plasma density is critical. Traditional density interferometry has been ineffective for these laser-machined structures, while group velocity delay (GVD) techniques involve combining two laser paths with corresponding alignment complexities and stability sensitivities. Here the GVD technique is advanced to a common-path two-color interferometer configuration performed in the spectral domain of a broad-bandwidth femtosecond laser. Multi-shot tracking of the phase is not required, and the common path assures improved stability. Here, this in situ technique was validated on 15 mm long plasma structures, measuring electron densities of 10 17 -10 18 cm -3 for various fill pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral interferometry-based microwave-frequency vibrometry for integrated acoustic wave devices

Microwave phononics is a promising platform for sensing, computing, and quantum information science; thus, sensitive and high-throughput characterization tools are needed not only for device verification and optimization but also for revealing transient and nonlinear dynamics. Existing interferometric optical vibrometers for 2D mapping are challenged by operating point stabilization, surface reflectivity contrast, and long acquisition time. Here, we use spectral interferometry, which is insensitive to these factors and utilizes a continuous raster scanning scheme for vibration mapping with high throughput. We intensity-modulate our broadband light source with an electro-optic modulator to resolve vibrations at microwave frequencies. Our system requires no fast photodetector or digitizer operating in the microwave frequency range. We image the 1 GHz vibration field of a 300 × 150 µm 2 area of an entire surface acoustic wave device in 10 min with simultaneous surface profilometry. Our system has a vibration sensitivity of 120 fm/sqrt(Hz) and a linear throughput of 0.77 mm/s on the chip surface. The technique offers capabilities for characterizing a wide range of acoustic wave and micromechanical devices to better understand their behavior and performance.

47 OTHER INSTRUMENTATION↗

Direct measurement of the matched spot size in a slow capillary discharge optical waveguide

This communication presents direct method for experimental determining the matched spot size in a plasma optical waveguide, created in a slow capillary discharge. It can be used for Laser Wakefield Acceleration experiments in addition to interferometry for fast control of optical properties of discharge plasma. The measurements are done by means of the comparison of the laser beam size at the entrance and at the exit of the plasma channel. They are direct in the sense that the interpretation is made in terms of the refractive index without usage of the information about electron density distribution. The method can be used for matched spot size measurement in conditions of the nonlinear effects (transmission of high power laser pulses)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon self-induced spin-to-orbital conversion in a terbium-gallium-garnet crystal at high laser power

In this paper, we present experimental evidence of a third-order nonlinear optical process, self-induced spin-to-orbital conversion (SISTOC) of the photon angular momentum. This effect is the physical mechanism at the origin of the depolarization of very intense laser beams propagating in isotropic materials. The SISTOC process, like self-focusing, is triggered by laser heating leading to a radial temperature gradient in the medium. In this work we tested the occurrence of SISTOC in a terbium-gallium-garnet rod for an impinging laser power of about 100 W. To study the SISTOC process we used different techniques: polarization analysis, interferometry, and tomography of the photon orbital angular momentum. Our results confirm, in particular, that the apparent depolarization of the beam is due to the occurrence of maximal entanglement between the spin and orbital angular momentum of the photons undergoing the SISTOC process. This explanation of the true nature of the depolarization mechanism could be of some help in finding novel methods to reduce or to compensate for this usually unwanted depolarization effect in all cases where very high laser power and good beam quality are required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of dynamic patterns of an elastic membrane at bi-modal vibration using high speed electronic speckle pattern interferometry

Implementing a hybrid arrangement of Laser Doppler Vibrometry (LDV) and high speed Electronic Speckle Pattern Interferometry (ESPI) we were able to measure the dynamic patterns of a flat rectangular elastic membrane clamped at its edges stimulated with the sum of two resonance frequencies. ESPI is a versatile technique to analyze in real-time the deformation of a membrane since its low computational cost and easy implementation of the optical setup. Elastic membranes present nonlinear behaviors when stimulated with low amplitude signals. The elastic membrane under test, with several non rational related vibrating modals below the 200 Hz, was stimulated with two consecutives resonant frequencies. The ESPI patterns, acquired at high speed rates, shown a similar behavior for the dual frequency stimulation as in the case of patterns formed with the entrainment frequency. We think this may be related to the effects observed in the application of dual frequency stimulation in ultrasound.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE PARABOLIC JET STRUCTURE IN M87 AS A MAGNETOHYDRODYNAMIC NOZZLE

The structure and dynamics of the M87 jet from sub-milliarcsec to arcsecond scales are continuously examined. We analyzed the Very Long Baseline Array archival data taken at 43 and 86 GHz to measure the size of very long baseline interferometry (VLBI) cores. Millimeter/sub-millimeter VLBI cores are considered as innermost jet emissions, which has been originally suggested by Blandford and Königl. Those components fairly follow an extrapolated parabolic streamline in our previous study so that the jet has a single power-law structure with nearly 5 orders of magnitude in the distance starting from the vicinity of the supermassive black hole (SMBH), less than 10 Schwarzschild radius (r{sub s}). We further inspect the jet parabolic structure as a counterpart of the magnetohydrodynamic (MHD) nozzle in order to identify the property of a bulk acceleration. We interpret that the parabolic jet consists of Poynting-flux dominated flows, powered by large-amplitude, nonlinear torsional Alfvén waves. We examine the non-relativistic MHD nozzle equation in a parabolic shape. The nature of trans-fast magnetosonic flow is similar to the one of transonic solution of Parker's hydrodynamic solar wind; the jet becomes super-escape as well as super-fast magnetosonic at around ∼10{sup 3} r{sub s}, while the upstream trans-Alfvénic flow speed increases linearly as a function of the distance at ∼10{sup 2}-10{sup 3} r{sub s}. We here point out that this is the first evidence to identify these features in astrophysical jets. We propose that the M87 jet is magnetically accelerated, but thermally confined by the stratified interstellar medium inside the sphere of gravitational influence of the SMBH potential, which may be a norm in active galactic nucleus jets.

79 ASTRONOMY AND ASTROPHYSICS↗

General relativistic effects in atom interferometry

Atom interferometry is now reaching sufficient precision to motivate laboratory tests of general relativity. We begin by explaining the nonrelativistic calculation of the phase shift in an atom interferometer and deriving its range of validity. From this, we develop a method for calculating the phase shift in general relativity. Both the atoms and the light are treated relativistically and all coordinate dependencies are removed, thus revealing novel terms, cancellations, and new origins for previously calculated terms. This formalism is then used to find the relativistic effects in an atom interferometer in a weak gravitational field for application to laboratory tests of general relativity. The potentially testable relativistic effects include the nonlinear three-graviton coupling, the gravity of kinetic energy, and the falling of light. We propose specific experiments, one currently under construction, to measure each of these effects. These experiments could provide a test of the principle of equivalence to 1 part in 10{sup 15} (300 times better than the present limit), and general relativity at the 10% level, with many potential future improvements. We also consider applications to other metrics including the Lense-Thirring effect, the expansion of the Universe, and preferred frame and location effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A method for measuring the amplitude and phase of ultrashort laser pulses using self-modulation in a Kerr medium and spectral interferometry

A new method is proposed for measuring the field of ultrashort pulses by assessing spectral interference between an input pulse and the pulse transmitted through a Kerr medium. The proposed iterative algorithm allows the pulse amplitude and phase to be reconstructed. Our numerical experiments demonstrate that the proposed algorithm can be used to reconstruct pulses with complex intensity and phase shapes and is stable to a noise in input data. The method requires that only one nonlinear element be placed in the laser beam to be studied. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shock compression of diamond single crystals to 120 GPa: Refractive index and nonlinear photoelasticity

The optical response of transparent solids at extreme conditions is important for both fundamental science and many applications. Strong transparent solids are of particular interest for use as optical windows in dynamic compression experiments. Due to diamond’s exceptional strength and optical properties, laser-driven shock experiments and plate impact experiments were carried out to examine the diamond optical response for shock wave compression along two different crystal orientations. Using laser interferometry at 532 nm and 1550 nm wavelengths, optical transparency was observed and refractive indices were determined for [100] diamond at stresses up to 119 GPa and for [111] diamond at stresses up to 87 GPa. From these results, the nonlinear photoelastic response for [100] and [111] diamond was determined, revealing significant dependence on both crystal orientation and laser wavelength. To enable [100] diamond as an interferometry window in dynamic compression experiments, the requisite window corrections were determined for 532 nm and 1550 nm wavelengths. Because of diamond’s excellent x-ray transparency, the present findings will be particularly useful for incorporating [100] diamonds as windows in dynamic compression experiments involving x-ray diffraction or other x-ray diagnostics.