Search NASA⌕ Search

SEARCH · Search NASA

Results for “object positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Machine Vision-based Robot Manipulators for Nuclear Applications - 20370

Decommissioning and dismantling of nuclear facilities are major challenges facing the nuclear industry. Robot manipulators with capabilities of restoring nuclear structures and significantly prolonging nuclear power generation in addition to their applications in decommissioning and dismantling (D and D) would immensely ease the above-mentioned challenge. Ability to remotely sense/monitor and analyze dangerous and hazardous environments such as nuclear reactors as well as performing reparatory tasks in such environments using robot manipulators require additional information from vision sensors. Structural sample collection and inspection as well as restoration require object and position information. Computer vision is used to obtain precise 3D position information. The current work uses the Sawyer robot with the integrated Cognex camera. The research presents an approach to facilitate and improve operations in a nuclear reactor using robotic vision control. The vision control system is modeled with Augmented Image Space-based visual servoing approach. Results showing accurate robot control. Object recognition is used to recognize the image and calculate it poses. To transform coordinates of the object's pose from the camera frame to the robotic frame transformation matrices are employed. Future work will employ a 3D camera (with depth information) using Denso robot. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Upright cone beam CT imaging using the onboard imager

Purpose: Many patients could benefit from being treated in an upright position. The objectives of this study were to determine whether cone beam computed tomography (CBCT) could be used to acquire upright images for treatment planning and to demonstrate whether reconstruction of upright images maintained accurate geometry and Hounsfield units (HUs). Methods: A TrueBeam linac was programmed in developer mode to take upright CBCT images. The gantry head was positioned at 0°, and the couch was rotated to 270°. The x-ray source and detector arms were extended to their lateral positions. The x-ray source and gantry remained stationary as fluoroscopic projections were taken and the couch was rotated from 270° to 90°. The x-ray tube current was normalized to deposit the same dose (measured using a calibrated Farmer ion chamber) as that received during a clinical helical CT scan to the center of a cylindrical, polyethylene phantom. To extend the field of view, two couch rotation scans were taken with the detector offset 15 cm superiorly and then 15 cm inferiorly. The images from these two scans were stitched together before reconstruction. Upright reconstructions were compared to reconstructions from simulation CT scans of the same phantoms. Two methods were investigated for correcting the HUs, including direct calibration and mapping the values from a simulation CT. Results: Overall geometry, spatial linearity, and high contrast resolution were maintained in upright reconstructions. Some artifacts were created and HU accuracy was compromised; however, these limitations could be removed by mapping the HUs from a simulation CT to the upright reconstruction for treatment planning. Conclusions: The feasibility of using the TrueBeam linac to take upright CBCT images was demonstrated. This technique is straightforward to implement and could be of enormous benefit to patients with thoracic tumors or those who find a supine position difficult to endure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE BOLOCAM GALACTIC PLANE SURVEY. XII. DISTANCE CATALOG EXPANSION USING KINEMATIC ISOLATION OF DENSE MOLECULAR CLOUD STRUCTURES WITH {sup 13}CO(1-0)

We present an expanded distance catalog for 1710 molecular cloud structures identified in the Bolocam Galactic Plane Survey (BGPS) version 2, representing a nearly threefold increase over the previous BGPS distance catalog. We additionally present a new method for incorporating extant data sets into our Bayesian distance probability density function (DPDF) methodology. To augment the dense-gas tracers (e.g., HCO{sup +}(3-2), NH{sub 3}(1,1)) used to derive line-of-sight velocities for kinematic distances, we utilize the Galactic Ring Survey (GRS) {sup 13}CO(1-0) data to morphologically extract velocities for BGPS sources. The outline of a BGPS source is used to select a region of the GRS {sup 13}CO data, along with a reference region to subtract enveloping diffuse emission, to produce a line profile of {sup 13}CO matched to the BGPS source. For objects with a HCO{sup +}(3-2) velocity, ≈95% of the new {sup 13}CO(1-0) velocities agree with that of the dense gas. A new prior DPDF for kinematic distance ambiguity (KDA) resolution, based on a validated formalism for associating molecular cloud structures with known objects from the literature, is presented. We demonstrate this prior using catalogs of masers with trigonometric parallaxes and H II regions with robust KDA resolutions. The distance catalog presented here contains well-constrained distance estimates for 20% of BGPS V2 sources, with typical distance uncertainties ≲ 0.5 kpc. Approximately 75% of the well-constrained sources lie within 6 kpc of the Sun, concentrated in the Scutum-Centaurus arm. Galactocentric positions of objects additionally trace out portions of the Sagittarius, Perseus, and Outer arms in the first and second Galactic quadrants, and we also find evidence for significant regions of interarm dense gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Multivariable Analysis of Aerodynamic Forces on Slotted Airfoils for Wind Turbine Blades

Improvement of the aerodynamic performance for cambered airfoils with leading-edge slots is investigated in this work. This concept is proven both computationally and experimentally in recent years. Five design variables of interest are slot's length, slot's width or thickness, inlet angle, exit angle, and the vertical position. The objective is to perform design of experiment and optimization studies on these variables and evaluate the behavior of the objective functions, namely lift and lift over drag ratio (LoD), within the appropriate ranges of the independent variables. Simulations are mainly carried out at the Reynolds number of 1.6 × 10 6 and the angles of attack (AoA) of 6 deg for NACA 4412 airfoil. However, some of the analyses are repeated at Reynolds number of 3.2 × 10 6 and AoA of 0 and 8 deg to show the scalability of the results. Results indicate that the proper selection of three of the design variables, i.e., length, inlet angle, and vertical position, can have a significant impact on both lift and LoD, while the other two variables seem less influential. For the combination of the operating conditions and the values of the design variables considered in this investigation, a LoD improvement as large as 11% is observed.

Energy & Fuels↗

Understanding KKLT from a 10d perspective

Some of the most well-celebrated constructions of metastable de Sitter vacua from string theory, such as the KKLT proposal, involve the interplay of gaugino condensation on a D7-brane stack and an uplift by a positive tension object. These constructions have recently been challenged using arguments that rely on the trace-reversed and integrated 10d Einstein equation. We give a critical assessment of such concerns. We first relate an integrated 10d Einstein equation to the extremization condition for a 10d-derived 4d effective potential. Then we argue how to obtain the latter from a 10d action which incorporates gaugino condensation in a (recently proposed) manifestly finite, perfect-square form. This effective potential is consistent with 4d supergravity and does not present obstacles for an uplifted minimum. Moreover, within standard approximations, we understand the uplift explicitly in one of the popular versions of the integrated 10d equation. Our conclusion is that de Sitter constructions of the KKLT type cannot be dismissed simply based on the integrated 10d equations considered so far.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emergent Newtonian dynamics and the geometric origin of mass

We consider a set of macroscopic (classical) degrees of freedom coupled to an arbitrary many-particle Hamiltonian system, quantum or classical. These degrees of freedom can represent positions of objects in space, their angles, shape distortions, magnetization, currents and so on. Expanding their dynamics near the adiabatic limit we find the emergent Newton’s second law (force is equal to the mass times acceleration) with an extra dissipative term. In systems with broken time reversal symmetry there is an additional Coriolis type force proportional to the Berry curvature. We give the microscopic definition of the mass tensor. The mass tensor is related to the non-equal time correlation functions in equilibrium and describes the dressing of the slow degree of freedom by virtual excitations in the system. In the classical (high-temperature) limit the mass tensor is given by the product of the inverse temperature and the Fubini–Study metric tensor determining the natural distance between the eigenstates of the Hamiltonian. For free particles this result reduces to the conventional definition of mass. This finding shows that any mass, at least in the classical limit, emerges from the distortions of the Hilbert space highlighting deep connections between any motion (not necessarily in space) and geometry. We illustrate our findings with four simple examples. -- Highlights: •Derive the macroscopic Newton’s equation from the microscopic many-particle Schrödinger’s equation. •Deep connection between geometry and dynamics. •Geometrical interpretation of the mass of macroscopic object as deformation of Hilbert space. •Microscopic expression for mass and friction tensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Casimir Forces On A Silicon Micromechanical Chip

Quantum fluctuations give rise to van der Waals and Casimir forces that dominate the interaction between electrically neutral objects at sub-micron separations. Under the trend of miniaturization, such quantum electrodynamical effects are expected to play an important role in micro- and nano-mechanical devices. Nevertheless, so far the Casimir force has been experimentally observed only in situations involving an external object manually positioned close to a micromechanical element on a silicon chip. Here, we demonstrate the Casimir effect between two silicon components on the same substrate. In addition to providing an integrated and compact platform for Casimir force measurements, this scheme also opens the possibility of tailoring the Casimir force using lithographically defined components of non-conventional shapes on a single micromechanical chip.

Zou, J.↗

Kinematic Sunyaev-Zel’dovich effect with ACT, DES, and BOSS: A novel hybrid estimator

The kinematic and thermal Sunyaev-Zel’dovich (kSZ and tSZ) effects probe the abundance and thermodynamics of ionized gas in galaxies and clusters. We present a new hybrid estimator to measure the kSZ effect by combining cosmic microwave background temperature anisotropy maps with photometric and spectroscopic optical survey data. The method interpolates a velocity reconstruction from a spectroscopic catalog at the positions of objects in a photometric catalog, which makes it possible to leverage the high number density of the photometric catalog and the precision of the spectroscopic survey. Combining this hybrid kSZ estimator with a measurement of the tSZ effect simultaneously constrains the density and temperature of free electrons in the photometrically selected galaxies. Using the 1000 deg 2 of overlap between the Atacama Cosmology Telescope (ACT) Data Release 5, the first three years of data from the Dark Energy Survey (DES), and the Baryon Oscillation Spectroscopic Survey (BOSS) Data Release 12, we detect the kSZ signal at 4.8 σ and reject the null (no-kSZ) hypothesis at 5.1 σ . This corresponds to 2.0 σ per 100,000 photometric objects with a velocity field based on a spectroscopic survey with 1 / 5 th the density of the photometric catalog. For comparison, a recent ACT analysis using exclusively spectroscopic data from BOSS measured the kSZ signal at 2.1 σ per 100,000 objects. Our derived constraints on the thermodynamic properties of the galaxy halos are consistent with previous measurements. With future surveys, such as the Dark Energy Spectroscopic Instrument and the Rubin Observatory Legacy Survey of Space and Time, we expect that this hybrid estimator could result in measurements with significantly better signal-to-noise than those that rely on spectroscopic data alone.

79 ASTRONOMY AND ASTROPHYSICS↗

Redshift propagation equations in the {beta}{sup '{ne}}0 Szekeres models

The set of differential equations obeyed by the redshift in the general {beta}{sup '{ne}}0 Szekeres spacetimes is derived. Transversal components of the ray's momentum have to be taken into account, which leads to a set of 3 coupled differential equations. It is shown that in a general Szekeres model, and in a general Lemaitre-Tolman (L-T) model, generic light rays do not have repeatable paths (RLPs): two rays sent from the same source at different times to the same observer pass through different sequences of intermediate matter particles. The only spacetimes in the Szekeres class in which all rays are RLPs are the Friedmann models. Among the proper Szekeres models, RLPs exist only in the axially symmetric subcases, and in each one the RLPs are the null geodesics that intersect each t=constant space on the symmetry axis. In the special models with a 3-dimensional symmetry group (L-T among them), the only RLPs are radial geodesics. This shows that RLPs are very special and in the real Universe should not exist. We present several numerical examples which suggest that the rate of change of positions of objects in the sky, for the studied configuration, is 10{sup -6}-10{sup -7} arc sec per year. With the current accuracy of direction measurement, this drift would become observable after approximately 10 years of monitoring. More precise future observations will be able, in principle, to detect this effect, but there are basic problems with determining the reference direction that does not change.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Framework for X-ray mirror surface shape fitting

For accurate characterization of grazing-incidence X-ray mirrors, we present a comprehensive framework to fit measured surface shapes (either slope or height) of X-ray mirrors used in synchrotron radiation and free-electron laser facilities. We summarize the closed-form expressions of some typical surface shapes of X-ray mirrors including elliptic cylinders, hyperbolic cylinders, ellipsoids, hyperboloids, and diaboloids. This framework is composed of four layers: definition of standard shapes with closed-form expressions, generation of theoretical surface with pose parameters (six degrees of freedom defining an object's position and orientation relative to a coordinate system), parameter optimization with the ability to select which parameters are fit and which are held constant, and the development of user-friendly fitting function wrappers for particular fitting tasks. A few practical fitting examples are demonstrated to verify the effectiveness of the proposed fitting framework. We discuss the physical meanings of the fitting parameters, and provide several examples using the elliptic cylinder and ellipsoid shapes to highlight some features of the framework. Moreover, we provide the presented framework as open-source codes (MATLAB and Python codes available at https://github.com/nsls2omf/xmf) to the community to encourage academic collaboration and further improvements.

36 MATERIALS SCIENCE↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

Improving Phase Measurement Procedures for Pump-Probe Experiments

Pump-probe experiments use a visible laser to excite an atom or molecule, while an X-ray pulse measures its shape. The phases and pulse times of each beam are used to calculate the object's positing at a given time - a moving picture of the chemical reaction. Currently, the fastest X-ray pulses can travel a time-length of five femtoseconds. However, present-day phase measurements can only be done as quickly as 50 femtoseconds. The purpose of this research is to explore ways in which phase-timing measurements can be improved. Three experiments are undergone to find the key factors in phase-timing. Different frequency mixers, the radio frequency (RF) components used for phase measurement, are tested for the highest sensitivity. These same mixers are then tested using two different power splitters for the lowest noise-to-sensitivity ratio. Lastly, the temperature dependency of phase is explored by testing each component at a range of temperatures to see how the phase is affected. This research demonstrated that certain mixers were more sensitive than others; on average, one mixer performed the best with a sensitivity of 0.0230 V/ps. The results also showed that same mixer combined with one splitter gave the best noise-to-sensitivity ratio overall with an average of 6.95E-04 fs/{radical}(Hz). All the components tested exhibited a temperature-dependent phase change (ranging from 1.69 to 81.6 fs/{sup o}C); the same mixer that performed at the highest sensitivity with the least noise had a significantly greater phase change than the other two. In conclusion, the experiments showed that a temperature-controlled environment is most appropriate for phase measurement. They also demonstrated that mixers are not significantly noisy and that certain types of mixers may perform better than others, which could be accounted for in their construction. The results of this research encourage further investigation into the study of different mixers and other RF components used in pump-probe experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Colors of Irregular Satellites of Saturn with the Dark Energy Camera

We report g – r and r – i new colors for 21 Saturn Irregular Satellites; among them, four previously unreported. This is the highest number of Saturn Irregular satellites reported in a single survey. These satellites were measured by "stacking" their observations to increase their signal without trailing. This work describes a novel processing algorithm that enables the detection of faint sources under significant background noise and in front of a severely crowded field. Our survey shows these new color measurements of Saturn Irregular Satellites are consistent with other Irregular Satellites populations as found in previous works and reinforcing the observation that the lack of ultrared objects among the irregular satellites is a real feature that separates them from the trans-Neptunian objects (their posited source population).

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling the long-term evolution of space debris

A space object modeling system that models the evolution of space debris is provided. The modeling system simulates interaction of space objects at simulation times throughout a simulation period. The modeling system includes a propagator that calculates the position of each object at each simulation time based on orbital parameters. The modeling system also includes a collision detector that, for each pair of objects at each simulation time, performs a collision analysis. When the distance between objects satisfies a conjunction criterion, the modeling system calculates a local minimum distance between the pair of objects based on a curve fitting to identify a time of closest approach at the simulation times and calculating the position of the objects at the identified time. When the local minimum distance satisfies a collision criterion, the modeling system models the debris created by the collision of the pair of objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser Doppler sensor employing a single fan-shaped interference fringe system for distance and shape measurement of laterally moving objects

For monitoring the position and shape of fast moving and, especially, rotating objects such as turbo machine rotors, contactless and compact sensors with a high measurement rate as well as high precision are required. We present for the first time, to the best of our knowledge, a novel laser Doppler sensor employing a single fan-shaped interference fringe system, which allows measuring for the position and shape of fast moving solid bodies with known tangential velocity. It is shown theoretically as well as experimentally that this sensor offers concurrently high position resolution and high temporal resolution in contrast to conventional measurement techniques, since its measurement uncertainty is, in principle, independent of the object velocity. Moreover, it can be built very compact, because it features low complexity. To prove its operational capability and its potential for practical applications, radial and axial shape measurements of rotating bodies are demonstrated in comparison with triangulation. An average position resolution of about 2 {mu}m could be achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-197: Investigation of Microsoft Kinect 2.0 Depth Resolution for Patient Motion Tracking

Purpose: Investigate the use of the Kinect 2.0 for patient motion tracking during radiotherapy by studying spatial and depth resolution capabilities. Methods: Using code written in C#, depth map data was abstracted from the Kinect to create an initial depth map template indicative of the initial position of an object to be compared to the depth map of the object over time. To test this process, simple setup was created in which two objects were imaged: a 40 cm × 40 cm board covered in non reflective material and a 15 cm × 26 cm textbook with a slightly reflective, glossy cover. Each object, imaged and measured separately, was placed on a movable platform with object to camera distance measured. The object was then moved a specified amount to ascertain whether the Kinect’s depth camera would visualize the difference in position of the object. Results: Initial investigations have shown the Kinect depth resolution is dependent on the object to camera distance. Measurements indicate that movements as small as 1 mm can be visualized for objects as close as 50 cm away. This depth resolution decreases linearly with object to camera distance. At 4 m, the depth resolution had decreased to observe a minimum movement of 1 cm. Conclusion: The improved resolution and advanced hardware of the Kinect 2.0 allows for increase of depth resolution over the Kinect 1.0. Although obvious that the depth resolution should decrease with increasing distance from an object given the decrease in number of pixels representing said object, the depth resolution at large distances indicates its usefulness in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Models of the strongly lensed quasar DES J0408-5354

We present gravitational lens models of the multiply imaged quasar DES J0408-5354, recently discovered in the Dark Energy Survey (DES) footprint, with the aim of interpreting its remarkable quad-like configuration. We first model the DES single-epoch $grizY$ images as a superposition of a lens galaxy and four point-like objects, obtaining spectral energy distributions (SEDs) and relative positions for the objects. Three of the point sources (A,B,D) have SEDs compatible with the discovery quasar spectra, while the faintest point-like image (G2/C) shows significant reddening and a `grey' dimming of $\approx0.8$mag. In order to understand the lens configuration, we fit different models to the relative positions of A,B,D. Models with just a single deflector predict a fourth image at the location of G2/C but considerably brighter and bluer. The addition of a small satellite galaxy ($R_{\rm E}\approx0.2$") in the lens plane near the position of G2/C suppresses the flux of the fourth image and can explain both the reddening and grey dimming. All models predict a main deflector with Einstein radius between $1.7"$ and $2.0",$ velocity dispersion $267-280$km/s and enclosed mass $\approx 6\times10^{11}M_{\odot},$ even though higher resolution imaging data are needed to break residual degeneracies in model parameters. The longest time-delay (B-A) is estimated as $\approx 85$ (resp. $\approx125$) days by models with (resp. without) a perturber near G2/C. The configuration and predicted time-delays of J0408-5354 make it an excellent target for follow-up aimed at understanding the source quasar host galaxy and substructure in the lens, and measuring cosmological parameters. We also discuss some lessons learnt from J0408-5354 on lensed quasar finding strategies, due to its chromaticity and morphology.

79 ASTRONOMY AND ASTROPHYSICS↗