Search NASA⌕ Search

SEARCH · Search NASA

Results for “open circuit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Incorporating Electrochemical Halide Oxidation into Drift-Diffusion Models to Explain Performance Losses in Perovskite Solar Cells under Prolonged Reverse Bias

Partial shading of a solar module can induce a set of cells within the module to operate under reverse bias. Studies have shown that metal halide perovskite solar cells with a wide variety of compositions and contacts exhibit interesting behavior in reverse bias that includes both reversible performance loss and non-reversible degradation. In this paper, an advanced drift-diffusion approach incorporating an electrochemical term to explain the short-circuit, open circuit and fill factor losses that are experimentally measured after prolonged reverse bias is used. It is shown that holes can tunnel into the perovskite due to sharp band bending near the contact, accumulate within the bulk of the perovskite absorber, and trigger the oxidation of halides to form neutral halogens. The density of neutral halogens is much higher in reverse bias because there are hardly any electrons available to reduce the iodine. The resulting halogens act as bulk recombination centers. While the interstitial halogen density does decay when the cell is operated in forward bias, permanent degradation can occur if the iodine diffuses out of the perovskite layer. Finally, the ways in which changing parameters such as the mobile ion density or the series resistance at the contact can influence device performance and stability are discussed.

degradation↗

Potentiometric sensor

According to one aspect of the invention, a potentiometric sensor having a cathode and an anode. The cathode is configured to provide a summary voltage representative of at least two voltage points. The anode is configured to provide a first voltage. The cathode is in communication with the anode by a first electrolyte forming an open circuit having an open circuit potential. Within the first electrolyte is a concentration of a target ion. The open circuit potential mathematically corresponds to the concentration of the target ion.

Cao, Guoping↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutralization Short-Circuiting with Weak Electrolytes Erodes the Efficiency of Bipolar Membranes

Bipolar membranes (BPMs) are critical components of a variety of electrochemical energy technologies. Many electrochemical applications require the use of buffers to maintain stable, nonextreme pH environments, yet the impact of buffers or weak acids/bases on the electrochemical behavior of BPMs remains poorly understood. Here, our data for a cell containing weak electrolytes is consistent with internal pH gradients within the anion exchange membrane (AEM) or cation exchange membrane (CEM) component of the BPM that form via ionic short-circuiting processes at open-circuit. Short-circuiting results from the coupling of co-ion crossover and parasitic neutralization and leads to buffering of the bipolar interface. This phenomenon, which we term neutralization short-circuiting, serves to erode BPM efficiency by attenuating the open-circuit membrane voltage and introducing parasitic reverse bias currents associated with weak acid/base dissociation at the interface. These findings establish a mechanistic basis for the operation of BPM cells in the presence of weak acid/base electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ZnTiN 2 as an Electron-Selective, Protective Layer on Si Photocathodes

Photoelectrochemical production of fuels requires photoelectrodes that efficiently convert sunlight to electrochemical energy by producing photovoltage and photocurrent and maintain this ability over time under a variety of pH, illumination, and applied bias conditions. Work in the photovoltaic community has demonstrated that interfaces with high charge carrier selectivity provide high photovoltages. This offers a co-design opportunity to create semiconductor photoelectrodes with contact layers that are both carrier-selective and offer protection from degradation in aqueous solutions. In this work, we explored the ternary nitride ZnTiN 2 as an electronselective, protective layer for Si-based photocathodes. We demonstrated that ZnTiN 2 formed a heterojunction with p-type Si that facilitated electron movement toward the ZnTiN 2 surface for light-driven reduction reactions. Across a variety of electrolyte conditions, ZnTiN 2 /Si produced an open circuit voltage of ca. 400 mV vs the solution potential, while bare Si produced 220−480 mV vs the solution potential depending on conditions. ZnTiN 2 was also shown to protect Si over 72 h at open circuit in the dark in 0.1 M KHCO 3 aqueous solution at pH 10.5, with a 2.4% loss in open circuit voltage compared to a 17% loss for unprotected Si. A protective effect was also observed under illumination during methyl viologen reduction at pH 3.5 for 21 h, with a 2.5% loss in open circuit voltage observed for ZnTiN 2 /Si compared to a 25% loss in open circuit voltage for unprotected Si under the same conditions. Elemental characterization revealed the presence of oxides on the surface of ZnTiN 2 that are consistent with the Pourbaix diagram after photoelectrochemical operation; these oxides appeared to support durability without hindering charge carrier extraction to drive electrochemical work. This work highlights the promise of ZnTiN 2 for durable photoelectrochemical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Doping CdSexTe1-x/CdTe Graded Absorber Films with Arsenic for Thin-Film Photovoltaics

CdTe thin-film photovoltaics have demonstrated some of the lowest costs of electricity generation owing to its low material cost and ease of manufacturing. However, the full potential of polycrystalline CdTe photovoltaics can only be realized if the open-circuit voltage can be increased beyond 1 V Open-circuit voltage ~850-900 mV has been consistently observed for state-of-the-art polycrystalline CdTe solar cells. Open-circuit voltage of over 1V has been demonstrated for single crystal CdTe devices by doping with Group V elements. Therefore, this study is aimed at understanding behavior of polycrystalline CdTe devices with arsenic doping, its activation and process and performance optimization in order to overcome current voltage limitations in CdTe solar cells.

14 SOLAR ENERGY↗

Microbial potentiometric sensor array measurements in unsaturated soils

The overarching goal of this study is to demonstrate a novel technology for monitoring changes in electrical potential of unsaturated soils using biofilm-populated electrodes. The novelty of the study stems from the fact that it demonstrates a method for measuring open-circuit potentials (OCP) in environments without the presence of an electrolyte solution. This study also reveals that using a biofilm-populated electrode as a reference in stable environments could successfully be employed to assess and monitor the electrochemical potential generated by plants and microorganisms. The findings imply that long-term (months to years) and real-time measurements of the open-circuit potential in unsaturated soils are possible. Because MPS arrays can directly measure open-circuit potential from the biofilm, the challenges related to locally induced electrochemical changes caused by microorganisms in the soil to achieve optimum physiological levels are eliminated. The simplicity of the technology, which allows for multiple indicator electrodes to be referenced against an “internal” reference electrode, enables spatial-temporal monitoring of the changes in the soil and the generation of 2D- or 3D-signal patterns. Once a signal pattern, generated by an array of sensors, develops (usually after 30 to 90 days), it does not significantly change unless the soil is exposed to external stimuli. The observed OCP phenomena, however, suggests that the change in OCP signal is independent of changes in soil conductivity resulting from the addition of water. In brief, findings suggest that the proposed technology can enable multidimensional profiling and long-term monitoring of changes occurring in unsaturated soils without direct implications of presence of water. The changes in the 2D or 3-D signal patterns, however, can be correlated to other important parameters that characterize soil health.

54 ENVIRONMENTAL SCIENCES↗

Electrothermal Phenomena in Ferroelectrics

Physical properties of lead-zirconate-titanate (PZT) ceramics change according to the initial electric poling process and electrical boundary conditions. This paper reports the electrothermal, piezothermal, and piezoelectric coupling phenomena in ferroelectrics from thermodynamics viewpoints, in particular, thermal property differences between unpoled and poled PZT’s in the poling direction for open circuit and short circuit conditions. We propose a new terminology, “secondary electrothermal” coupling factor kλ, which is analogous to the electromechanical coupling factor k, relating the elastic compliances under short- and open-circuit conditions, in order to explain the fact that the short-circuit condition exhibited the larger thermal diffusivity than the open-circuit condition. On the other hand, the unpoled specimen exhibits the lowest thermal diffusivity. This tutorial paper was authored for providing comprehensive knowledge on equilibrium and time-dependent thermodynamics in ferroelectrics.

Uchino, Kenji (ORCID:0000000316517912)↗

Evaluating capacity fade in dual insertion batteries using potential and temperature measurements

Methods and systems are described of managing a battery system. The battery system including at least one battery cell and one or more sensors configured to measure a temperature of the at least one battery cell. The method includes receiving a measurement of the temperature of the at least one battery cell, estimating an open circuit potential of the at least one battery cell, estimating a capacity fade of the at least one battery cell based on the open circuit potential of the at least one battery cell and a ratio of a change in the open circuit potential relative to a change in the temperature of the at least one battery cell, and regulating at least one of charging or discharging of the at least one battery cell based on the estimation of the capacity fade.

Christensen, John F.↗

Tracking Spatiotemporal Electric Potential in Batteries Using High-Resolution Operando X‑ray Transmission Imaging

The formation of significant concentration gradients across electrolytes in batteries affects the rate at which electrochemical reactions occur. In this work, we use high-resolution operando X-ray transmission imaging to capture spatiotemporal salt concentration profiles c(x,t) in a symmetric cell comprising a polymer electrolyte sandwiched between two lithium–indium alloy electrodes during a constant-current experiment followed by open-circuit relaxation. The decay of open-circuit potential is related to the concentration dependence of the potential across concentration cells, U. We show how operando c(x,t) data can be used to calculate the spatiotemporal electric potential “inside” the polarized electrolyte. We track the spatial- and time-dependent cell potential during the constant-current step and distinguish its two contributions: a concentration overpotential governed by U. and an ohmic contribution governed by ionic conductivity. Over most of the time window, the concentration overpotential dominates. At steady state, it is a factor of 7 larger than the ohmic contribution. Such findings indicate that efforts to design new polymer electrolytes should focus on minimizing concentration gradients.

Electrical conductivity↗

Redox Couples Control Band Bending, Photovoltage, and Quasi-Fermi Levels in Tungsten Oxide (WO 3 ) Photoanodes

Tungsten oxide (WO 3 ) is a well-known photoanode and photocatalyst for photoelectrochemical (PEC) water oxidation. Because the compound has a deep valence band, it can facilitate the oxygen evolution reaction without added cocatalysts, and it can drive the oxidation of species with much higher electrochemical potentials, including the conversion of water to hydrogen peroxide, sulfate to persulfate, and iodate to meta-periodate. Here, we use the liquid vibrating Kelvin probe surface photovoltage (liquid VK-SPV) technique in combination with open circuit potential (OCP) and photoelectrochemical (PEC) scans to assess the possibility of reaching such oxidizing potentials in aqueous electrolytes and at open circuit. Here, this is done by mapping the quasi-Fermi levels of electrons and holes at the interfaces as a function of the light intensity. Nanostructured WO 3 photoelectrodes for this purpose were fabricated by thermal annealing of a tungstic acid solution on fluorine-doped tin oxide. Electrochemical measurements are conducted at open circuit and 400 nm LED light illumination in electrolytes containing fast (O 2 /H 2 O 2 ), slow (O 2 /H 2 O), and very oxidizing (NaIO 4 /NaIO 3 ) redox couples. Photovoltage values scale with the light intensity and with the built-in potential for each redox couple and reach values up to 0.61 V under 20 mW cm –2 illumination for the NaIO 4 electrolyte. This shows that the photoelectrodes behave like Schottky-type diodes whose maximum possible energy output is determined mainly by the built-in voltage of each junction. For slow redox couples, the quasi-Fermi level of the holes increases with light intensity due to hole accumulation at the WO 3 –liquid interface. For example, for the O 2 /H 2 O electrolyte, interfacial hole accumulation and removal occur on the 90–300 s time scale. For the fast hole acceptor H 2 O 2 , on the other hand, the quasi-Fermi level of the photoholes is pinned to the electrochemical potential of the O 2 /H 2 O 2 couple. This limits the energy conversion efficiency of the electrode. Overall, these results reveal the influence of charge transfer thermodynamics and kinetics on the photovoltage of WO 3 . Furthermore, the work further establishes VK-SPV as a contactless method to observe the photovoltage, carrier dynamics, and quasi-Fermi levels of semiconductor-liquid junctions.

Electrodes↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Predicting Trends in VOC Through Rapid, Multimodal Characterization of State-of-the-Art p-i-n Perovskite Devices

Perovskite photovoltaic technologies are approaching commercial deployment, yet single junction and tandem architectures both still have significant room to improve power conversion efficiency and stability. The ability to perform rapid screening of material quality after altering processing conditions is critical to accelerating the optimization and commercialization of perovskite-based technologies. Currently, researchers utilize a wide range of stand-alone metrology tools to isolate sources of power loss throughout a device stack, which can be slow and labor intensive. Here, we demonstrate the use of a multimodal metrology approach to rapidly determine the maximum achievable and predicted open circuit voltages of >100 perovskite devices during fabrication. Acquisition of these different data is facilitated by combining them into a single integrated measurement platform. We show that these data and automated analysis can be used to rapidly understand and ultimately predict quantitative trends in open circuit voltages of state-of-the-art device architectures. The data and automated analysis workflow presented provides a reliable approach to quickly identify absorber and charge transport layer combinations that can lead to improved open circuit voltages.

14 SOLAR ENERGY↗