Search NASA⌕ Search

SEARCH · Search NASA

Results for “operational vibration environment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Relocatable 10 kW Solar Array for Lunar South Pole Missions

Deployable, relocatable, free-standing solar arrays are being developed to provide modular power for future lunar South Pole missions. Major design requirements for these arrays will be low mass, compact launch stowage, and highly reliable deployment and retraction. This paper presents a novel conceptual design for a10 kW solar array to address these requirements referred to as the Relocatable Solar Array (RSA).Simply stated, the concept is a pair of solar cell blankets freely hanging from a horizontal cross arm supported by a vertical, slender, telescoping mast resting on a deployable tripod base. A major factor in simplifying the design is that the force exerted by lunar gravity is used to deploy and maintain extension of the hanging array blankets. A second major factor in achieving the desired low mass and high volumetric efficiency is that the array operates in the vacuum, low-gravity, lunar environment with no deployed vibration frequency requirement. Such a low-load environment enables use of extraordinarily slender and low mass structural members to support the hanging array blankets. This concept was developed, in part, to serve as a NASA reference solar array concept against which other proposed arrays can be compared.

Lunar Surface Power↗

Stirling Research Laboratory Providing Independent Performance Verification of Convertors for a Stirling Radioisotope Generator

The Department of Energy (DOE), Germantown, Maryland, Stirling Technology Company (STC), Kennewick, Washington, and NASA Glenn Research Center are developing a free-piston Stirling convertor for a high-efficiency Stirling Radioisotope Generator for NASA Space Science missions. This generator is being developed for multimission use, including providing electric power for unmanned Mars rovers and for deep space missions. STC is developing the 55-W Technology Demonstration Convertor (TDC) under contract to DOE. Glenn is conducting an in-house technology project to assist in developing the convertor for readiness for space qualification and mission implementation. As part of this effort, a Stirling Research Laboratory was established to test the TDC's and related technologies. A key task is providing an independent verification and validation of the TDC performance. Four TDC's are now being tested at Glenn. Acceptance testing has been completed for all convertors, and in general, performance agreed well with that achieved by STC prior to the delivery of the convertors. Performance mapping has also been completed on two of the convertors over a range of hot-end temperatures (450 to 650 C), cold-end temperatures (80 to 120 C), and piston amplitudes (5.2 to 6.2 mm). These test data are available online at http://www.grc.nasa.gov/WWW/tmsb/. The TDC's can be tested in either a horizontal orientation with dual-opposed convertors or in a vertical orientation with a single convertor. Synchronized dual-opposed pairs are used for dynamically balanced operation that results in very low levels of vibration. The Stirling Research Laboratory also supports launch environment testing of the TDC's in Glenn's Structural Dynamics Laboratory and electromagnetic interference and electromagnetic compatibility characterization and reduction efforts. In addition, the TDC's will be used for long-term endurance testing, and preparations are underway for unattended operation.

Thieme, Lanny G.↗

Investigation of Gearbox Vibration Transmission Paths on Gear Condition Indicator Performance

Helicopter health monitoring systems use vibration signatures generated from damaged components to identify transmission faults. For damaged gears, these signatures relate to changes in dynamics due to the meshing of the damaged tooth. These signatures, referred to as condition indicators (CI), can perform differently when measured on different systems, such as a component test rig, or a full-scale transmission test stand, or an aircraft. These differences can result from dissimilarities in systems design and environment under dynamic operating conditions. The static structure can also filter the response between the vibration source and the accelerometer, when the accelerometer is installed on the housing. To assess the utility of static vibration transfer paths for predicting gear CI performance, measurements were taken on the NASA Glenn Spiral Bevel Gear Fatigue Test Rig. The vibration measurements were taken to determine the effect of torque, accelerometer location and gearbox design on accelerometer response. Measurements were taken at the housing and compared while impacting the gear set near mesh. These impacts were made at gear mesh to simulate gear meshing dynamics. Data measured on a helicopter gearbox installed in a static fixture were also compared to the test rig. The behavior of the structure under static conditions was also compared to CI values calculated under dynamic conditions. Results indicate that static vibration transfer path measurements can provide some insight into spiral bevel gear CI performance by identifying structural characteristics unique to each system that can affect specific CI response.

Dempsey, Paula J.↗

Effects Of Environmental And Operational Stresses On RF MEMS Switch Technologies For Space Applications

Micro Electro Mechanical Systems (MEMS) have been heralded for their ability to provide tremendous advantages in electronic systems through increased electrical performance, reduced power consumption, and higher levels of device integration with a reduction of board real estate. RF MEMS switch technology offers advantages such as low insertion loss (0.1- 0.5 dB), wide bandwidth (1 GHz-100 GHz), and compatibility with many different process technologies (quartz, high resistivity Si, GaAs) which can replace the use of traditional electronic switches, such as GaAs FETS and PIN Diodes, in microwave systems for low signal power (x < 500 mW) applications. Although the electrical characteristics of RF MEMS switches far surpass any existing technologies, the unknown reliability, due to the lack of information concerning failure modes and mechanisms inherent to MEMS devices, create an obstacle to insertion of MEMS technology into high reliability applications. All MEMS devices are sensitive to moisture and contaminants, issues easily resolved by hermetic or near-hermetic packaging. Two well-known failure modes of RF MEMS switches are charging in the dielectric layer of capacitive membrane switches and contact interface stiction of metal-metal switches. Determining the integrity of MEMS devices when subjected to the shock, vibration, temperature extremes, and radiation of the space environment is necessary to facilitate integration into space systems. This paper will explore the effects of different environmental stresses, operational life cycling, temperature, mechanical shock, and vibration on the first commercially available RF MEMS switches to identify relevant failure modes and mechanisms inherent to these device and packaging schemes for space applications. This paper will also describe RF MEMS Switch technology under development at NASA GSFC.

Jah, Muzar↗

Evaluating Manufacturing and Assembly Errors in Rotating Machinery to Enhance Component Performance

Manufacturing and assembly phases play a crucial role in providing products that meet the strict functional specifications associated with rotating machinery components. The errors resulting during the manufacturing and assembly of such components are correlated with the vibration and noise emanating from the final system during its operational lifetime. Vibration and noise are especially unacceptable elements in high-risk systems such as helicopters, resulting in premature component degradation and an unsafe flying environment. In such applications, individual components often are subject to 100% inspection prior to assembly, as well as during operation through rigorous maintenance, resulting in increased product development cycles and high production and operation costs. In this work, we focus on providing designers and manufacturing engineers with a technique to evaluate vibration modes and levels for each component or subsystem prior to putting them into operation. This paper presents a preliminary investigation of the correlation between vibrations and manufacturing and assembly errors using an experimental test rig, which simulates a simple bearing and shaft arrangement. A factorial design is used to study the effects of: 1) different manufacturing instances; 2) different assembly instances; and, 3) varying shaft speeds. The results indicate a correlation between manufacturing or assembly errors and vibrations measured from accelerometers. Challenges in developing a tool for DFM are identified, followed by a discussion of future work, including a real-world application to helicopter transmission vibrations.

Tumer, Irem Y.↗

Stellar Interferometer Tracking experiment - A proposed technology demonstration experiment

A flight experiment entitled the Stellar Interferometer Tracking Experiment (SITE) is described. The objective of the program is to validate the operation of the primary detector of a space-based optical interferometric telescope and to evaluate how isolation, vibration suppression, and pathlength control enable and enhance instrument operation in the disturbance environment of the Shuttle payload bay. The minimum set of hardware that can perform stellar interferometry is described and the need for nanometer pathlength and arcsecond jitter control is shown. The justification for flight, the experimental benefits, and the applications to future space missions are presented. Results of previous ground experiments that demonstrate the required disturbance rejection are reviewed, and initial estimates of open-loop and required closed-loop performance of the flight experiment are presented.

Blackwood, Gary↗

Space Qualification Issues in Acousto-optic and Electro-optic Devices

Satellite and space-based applications of photonic devices and systems require operational reliability in the harsh environment of space for extended periods of time. This in turn requires every component of the systems and their packaging to meet space qualifications. Acousto- and electro-optical devices form the major components of many current space based optical systems, which is the focus of this paper. The major space qualification issues are related to: mechanical stability, thermal effects and operation of the devices in the naturally occurring space radiation environment. This paper will discuss acousto- and electro-optic materials and devices with respect to their stability against mechanical vibrations, thermal cycling in operating and non-operating conditions and device responses to space ionizing and displacement radiation effects. Selection of suitable materials and packaging to meet space qualification criteria will also be discussed. Finally, a general roadmap for production and testing of acousto- and electro-optic devices will be discussed.

Prasad, Narasimha S.↗

Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Expansion Thermal Switch for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the thermal switch (TS) operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center including the pre-vibe thermal vacuum cycle test, vibration test, post-vibe thermal vacuum cycle test, and long duration thermal vacuum cycle test. The pre- and post-vibe thermal cycle and the long duration cycle test tested to hot and cold plateau initial temperatures of 40 °C, and -173 °C, respectively. The pre- and post-vibe tests required plateau holds of at least 2 hours, whereas the long duration cycle test required plateau holds of at least 20 hours. The tests each used a rate of temperature change of < 2 °C/min when transitioning between plateaus. The data collected from each thermal test is compared to show the operation of the TS both before and after the vibration test to GEVS levels, and throughout the long duration cycle test. From the data collected, the total conductance through the TS interfaces is calculated for both on (TS closed – during hot plateau) and off (TS open – during cold plateau) configurations, and the turndown ratio is also calculated. Challenges and lessons learned from the testing are also discussed.

thermal control technology↗

Dynamic Capability of an Operating Stirling Convertor

The NASA John H. Glenn Research Center and the US Department of Energy are currently developing a Stirling convertor for use as an advanced spacecraft power system for future NASA deep-space missions. NASA Headquarters has recently identified the Stirling technology generator for potential use as the spacecraft power system for two of NASA's new missions, the Europa Orbiter and the Solar Probe missions (planned for launch in 2006 and 2007 respectively). As part of the development of this power system, a Stirling Technology Demonstration Convertor was vibration tested at NASA John H. Glenn Research Center to verify its survivability and capability of withstanding the harsh dynamic environment typically seen by the spacecraft when it is launched by an expendable launch vehicle. The Technology Demonstration Convertor was fully operational (producing power) during the random vibration testing. The output power of the convertor and other convertor performance indicators were measured during the testing, and these results are discussed in this paper. Numerous accelerometers and force gauges also were used to provide information on the dynamic characteristics of the Technology Demonstration Convertor and as an indication of any possible damage due to the vibration. These measurements will also be discussed in this paper. The vibration testing of the Stirling Technology Demonstration Convertor was extremely successful. The Technology Demonstration Convertor survived all its vibration testing with no structural damage or functional performance degradation. As a result of this testing, the Stirling convertor's capability to withstand vibration has been demonstrated, enabling its usage in future spacecraft power systems.

Goodnight, Thomas W.↗

The US National Transonic Facility, NTF

The construction of the National Transonic Facility was completed in September 1982 and the start-up and checkout of tunnel systems were performed over the next two years. In August 1984, the Operational Readiness Review (ORR) was conducted and the facility was declared operational for final checkout of cryogenic instrumentation and control systems, and for the aerodynamic calibration and testing to commence. Also, the model access system for the cryogenic mode of operation would be placed into operation along with tunnel testing. Since the ORR, a host of operating problems resulting from the cryogenic environment were identified and solved. These range from making mechanical and electrical systems functional to eliminating temperature induced model vibration to coping with the outgassing of moisture from the thermal insulation. Additionally, a series of aerodynamic tests have demonstrated data quality and provided research data on several configurations. Some of the more significant efforts are reviewed since the ORR and the NTF status concerning hardware, instrumentation and process controls systems, operating constraints imposed by the cryogenic environment, and data quality are summarized.

Bruce, Walter E., Jr.↗

Damping and vibration considerations for the design of optical systems in a launch/space environment

Engineering philosophies for the design of optical systems launched into space and operating in a vacuum or cryovacuum environment are reviewed. Particular attention is given to sources of energy dissipation which are usually lumped under a single modal parameter denoted as the equivalent viscous damping coefficient. Caging and/or damping system components or application of viscoelastic materials and/or dry friction devices are considered to be alternative methods for stabilizing instruments sensitive to motion.

Richard, Ralph M.↗

Improvement in the control aspect of laser frequency stabilization for SUNLITE project

Flight Electronics Division of Langley Research Center is developing a spaceflight experiment called the Stanford University and NASA Laser In-Space Technology (SUNLITE). The objective of the project is to explore the fundamental limits on frequency stability using an FM laser locking technique on a Nd:YAG non-planar ring (free-running linewidth of 5 KHz) oscillator in the vibration free, microgravity environment of space. Compact and automated actively stabilized terahertz laser oscillators will operate in space with an expected linewidth of less than 3 Hz. To implement and verify this experiment, NASA engineers have designed and built a state of the art, space qualified high speed data acquisition system for measuring the linewidth and stability limits of a laser oscillator. In order to achieve greater stability and better performance, an active frequency control scheme requiring the use of a feedback control loop has been applied. In the summer of 1991, the application of control theory in active frequency control as a frequency stabilization technique was investigated. The results and findings were presented in 1992 at the American Control Conference in Chicago, and have been published in Conference Proceedings. The main focus was to seek further improvement in the overall performance of the system by replacing the analogue controller by a digital algorithm.

Zia, Omar↗

A Risk Analysis Tool for Estimating the Risk of Electrical Failures Due to Human Induced Defects

Aerospace electrical systems are required to withstand and adequately operate in extremely harsh environments that include, for example, high radiation exposure, temperature extremes, intense vibrational stress and drastic temperature cycling. The nature of aerospace electronics also demands high reliability since, with very few exceptions, there is no chance for hardware servicing or repairs. Common risk mitigation techniques for this type of situation are to perform a Reliability Analysis of the system throughout the development cycle, and to use electrical components that are regarded as “high reliability” because of additional controls and requirements applied in their design, manufacturing and testing. Unfortunately, studies have shown that even though these techniques are used, many systems fail to meet mission requirements well before the predicted lifetimes. This paper presents the analysis of failures of electrical parts, experienced during various stages of system development, at NASA Goddard Space Flight Center, Greenbelt MD, between the years 2001 and 2013. These components were subjected to qualification, screening and testing in which the goal was to ensure that the components would survive the stresses of the mission. The analysis categorizes failures by part type and failure mechanisms. One of the results of the analysis was the realization that a surprising proportion of failures experienced during system integration and testing were caused by human error (i.e. human induced defect). Further analysis included the determination of root failure mechanisms and any influencing factors contributing to these failures. The major causes of these defects were attributed to electrostatic damage (ESD), electrical overstress (EOS), mechanical overstress (MOS), and thermal overstress (TOS). Finally, the study proposes a risk analysis tool which incorporates these major causes for the failures, termed error-producing conditions (EPCs), and a proportionality factor representing the number of each type of failure that has occurred at the facility under study. These factors are quantified and used to communicate the risk of human induced defects for the assembly, integration and testing of space hardware based on the system’s electrical parts list. The new risk identification can trigger risk-mitigating actions more effectively, based on the presence of component categories or other hazardous conditions that have a history of failure due to human error.

Majewicz, Peter J.↗

Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Thermal Expansion (DTE) Thermal Switch (TS) for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the TS operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center (MSFC) including the vibration (vibe) test, pre-vibe thermal vacuum (t-vac) cycle test, post-vibe t-vac cycle test, and long duration t-vac cycle test. The data collected from the pre- and post-vibe tests are compared to show the impact of the vibe test on performance. The data collected from the long duration test is used to calculate the total thermal contact conductance through the TS interfaces for both ‘on’ (TS closed, during hot plateau) and ‘off’ (TS open, during cold plateau) configurations, and the turndown ratio is also calculated. Challenges experienced throughout testing are also discussed.

Thermal control technology↗

Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Thermal Expansion (DTE) Thermal Switch (TS) for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the TS operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center (MSFC) including the vibration (vibe) test, pre-vibe thermal vacuum (t-vac) cycle test, post-vibe t-vac cycle test, and long duration t-vac cycle test. The data collected from the pre- and post-vibe tests are compared to show the impact of the vibe test on performance. The data collected from the long duration test is used to calculate the total thermal contact conductance through the TS interfaces for both ‘on’ (TS closed, during hot plateau) and ‘off’ (TS open, during cold plateau) configurations, and the turndown ratio is also calculated. Challenges experienced throughout testing are also discussed.

Thermal control technology↗

Signal Processing Methods for Removing the Effects of Whole Body Vibration upon Speech

Humans may be exposed to whole-body vibration in environments where clear speech communications are crucial, particularly during the launch phases of space flight and in high-performance aircraft. Prior research has shown that high levels of vibration cause a decrease in speech intelligibility. However, the effects of whole-body vibration upon speech are not well understood, and no attempt has been made to restore speech distorted by whole-body vibration. In this paper, a model for speech under whole-body vibration is proposed and a method to remove its effect is described. The method described reduces the perceptual effects of vibration, yields higher ASR accuracy scores, and may significantly improve intelligibility. Possible applications include incorporation within communication systems to improve radio-communication systems in environments such a spaceflight, aviation, or off-road vehicle operations.

human response to vibration↗

Flight set 360L003 instrumentation final test report, volume 9

Post-flight instrumentation hardware and data evaluation for 360L003 is summarized. The 360L003 motors were equipped with Developmental Flight Instrumentation (DFI), Operational Flight Instrumentation (OFI), and Ground Environmental Instrumentation (GEI). The DFI was designed to measure strain, temperature, pressure, and vibration at various locations on the motor during flight. The DFI is used to validate engineering models in a flight environment. The OFI consists of six Operational Pressure Tranducers which monitor chamber pressure during flight. These pressure transducers are used in the SRB separation cue. GEI measures the motor case, igniter flange, and nozzle temperature prior to launch.

Source record↗

Structural dynamic and aeroelastic considerations for hypersonic vehicles

Structural dynamic and aeroelastic considerations applicable to hypersonic vehicles are discussed. Emphasis is given to aerospace plane configurations. The definition of aerothermoelasticity and the operational flight environment are reviewed, and structural dynamic and aeroelastic areas of concern are individually discussed, including vibration, landing and taxiing, propellant dynamics, acoustics, lifting surface flutter, panel flutter, control surface buzz, buffeting, gust response, and static aeroelasticity. Recent research results from all-moveable delta-wing aerolastic studies, engine inlet lip aeroelastic analysis, and studies of thermal effects on vibration frequencies, aerodynamic heating effects on flutter, and active control of aeroelastic response are reviewed.

Cazier, F. W., Jr.↗