Radiation-Hard, High-Bandwidth Optical Fiber Links for Detectors at High Energy Colliders
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The sheared-flow-stabilized Z pinch concept has been studied extensively and is able to produce fusion-relevant plasma parameters along with neutron production over several microseconds. In this work, we present elevated electron temperature results spatially and temporally coincident with the plasma neutron source. An optical Thomson scattering apparatus designed for the FuZE device measures temperatures in the range of 1–3 keV on the axis of the device, 20 cm downstream of the nose cone. The 17-fiber system measures the radial profiles of the electron temperature. Scanning the laser time with respect to the neutron pulse time over a series of discharges allows the reconstruction of the T e temporal response, confirming that the electron temperature peaks simultaneously with the neutron output, as well as the pinch current and inductive voltage generated within the plasma. Comparison to spectroscopic ion temperature measurements suggests a plasma in thermal equilibrium. The elevated T e confirms the presence of a plasma assembled on axis, and indicates limited radiative losses, demonstrating a basis for scaling this device toward net gain fusion conditions.
A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.
As diagnostic groups are increasingly called upon to participate in experimental campaigns at remote facilities, there is a need to develop portable versions of plasma diagnostic systems. One such diagnostic is laser induced fluorescence (LIF). Here, we describe a portable LIF apparatus that eliminates the need for an optical table, beam splitters, and an optical chopper. All of the light exiting the laser system is coupled through optical fibers to the experiment and housekeeping diagnostics. Here, the collected light is coupled through an optical fiber as well. A key feature is modulation of the tapered amplifier current instead of physical modulation of the laser output. Using this portable LIF system, measurements of ion temperature, ion flow, and relative metastable ion density are reported for two different remote experiments.
Here, in this work, we studied single-pulse ablation dynamics of a temporally modulated continuous wave laser-material interaction with Al using in situ multimodal time-resolved diagnostics that describe in detail the associated physical and chemical processes. Time-resolved scattering, emission imaging, and optical emission spectroscopy unveiled a sequence of events spread out across three distinct phases: (i) early phase ablation process, associated with particle generation and liquid Al column formation (<20 μs), (ii) secondary detonation when sufficient ejected material is accumulated over the surface (20-50 μs), and (iii) molten liquid Al pool oscillation on the surface, followed by large droplet ejection from the liquid pool (100-500 μs). Atomic Al and AlO were observed with optical emission spectroscopy at different ratios during the entire lifetime of the event, verifying the formation of oxidized Al vapor upon its interaction with air. Morphological and compositional characterization confirmed surface oxidation and material re-solidification in the form of protrusions produced during the irradiation process. This work provides insights into the complex physical and chemical mechanisms of single-pulse ablation in the sub-millisecond laser pulse regime, which are critically important for parameter optimization in a variety of laser processing, microfabrication, and deposition applications.
An actively Q-switched laser induced breakdown spectroscopy (LIBS) probe, utilizing an optical fiber, a pump beam transmitted through the optical fiber, a coupler, and a lens for collimating the pump beam. The actively Q-switched laser, coupled to a sensor which provides information to a computer that controls a high voltage pulser providing a pulse to a Pockels cell located within the laser which can selectively cause the laser to pulse, resulting in high energy pulses and a second lens for focusing the output pulse such that it creates a plasma or spark. The light from the spark is captured and directed back through an optical system to remote equipment for elemental and/or molecular analysis.
An optically recording velocity interferometer system has been used to measure acceleration histories and maximum velocities for laser-driven aluminum foil targets launched from the output face of optical fibers. Peak flyer velocities have been determined as a function of various parameters, including driving laser fluence, laser pulse duration and target thickness. The results at high fluences are consistent with a nearly constant efficiency of coupling optical energy into flyer kinetic energy and a small ablated mass fraction; however, the coupling efficiency falls off rapidly at fluences < 15 J-cm -2 . Measurement of the time delay between laser pulse arrival at the target and the onset of flyer motion have also been performed. Significant delays are observed at low fluences, arising from the increased time required for plasma formation at the fiber/foil interface under these conditions.
A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.
An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103–104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.
Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.
We present the first Thomson scattering measurements of electron density and temperature in the Large Plasma Device (LAPD), a 22 m long magnetized linear plasma device at the University of California Los Angeles (UCLA). The diagnostic spectrally resolves the Doppler shift imparted on light from a frequency-doubled Nd:YAG laser when scattered by plasma electrons. A fiber array coupled to a triple-grating spectrometer is used to obtain high stray light rejection and discriminate the faint scattering signal from a much larger background. In the center of the plasma column, the measured electron density and temperature are about ne≈1.5×1013 cm−3 and Te≈ 3 eV, respectively, depending on the discharge parameters and in good agreement with Langmuir probe data. Optical design considerations to maximize photon count while minimizing alignment sensitivity are discussed in detail and compared to numerical calculations. Raman scattering off of a quartz crystal probe is used for an absolute irradiance calibration of the system.
We describe the upgrades to the Thomson scattering (TS) diagnostic on the Lithium Tokamak eXperiment-beta (LTX- β ) to provide complete radial coverage of the plasma. LTX- β is a spherical tokamak with plasma limited at a major radius of R = 14 cm and R = 66 cm. Flat temperature profiles with peaked density were observed in LTX- β using an existing multipoint TS diagnostic with radial coverage of the plasma core. There is a need for more comprehensive core and edge TS measurements to thoroughly examine beam fueling, beam heating, and transport under low recycling conditions with liquid lithium walls and a lower collisionality scrape-off layer (SOL). The core TS set up provides plasma profiles from R = 40–60 cm. To extend the TS diagnostic coverage: 1) we added a TS viewing optics to cover the SOL region at five radial points from R = 57–64 cm, and 2) another TS viewing optics in the HFS region from R = 15–45 cm to obtain TS data from ten radial positions while making use of the original laser beam. The main focus of this article is on the new HFS TS setup that is equipped with better-matched collection optics located in the horizontal midplane where the laser polarization lies and views from a scattering angle of 130°–150° with respect to the laser path. A set of unequal-length Y-branched fiber bundles transports the TS light from two radial points to each polychromator. The new HFS view is better matched in spot size, scattering angle, and throughput to the laser and polychromators and has new V-grooved style viewing dumps. The new HFS TS view, along with the core and SOL TS views, will provide a full radial measurement coverage from R = 15–64 cm to explore the flat temperature profiles.
The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.
Rare earth elements and other metals are vital to a range of technologies that are used in the energy and defense sectors. However, monopolistic market conditions have caused significant concern over the stability of the critical metal supply chain, and this has spurred extensive efforts in many nations to produce these metals domestically, both from conventional sources such as mining and well as from unconventional sources such as coal and its utilization byproducts. Slow and expensive characterization methods pose a significant barrier for both metals prospecting and process monitoring. A promising solution to this challenge is the development of highly sensitive luminescent sensors for metals, which can offer low costs, portability, and sensitivity. Anionic zinc adeninate metal-organic frameworks (BioMOFs) are known to distinguishing and detect part-per-billion levels of terbium, europium, samarium, and dysprosium in water by sensitizing the narrow, element-specific emission bands from these lanthanides. Here, a BioMOF material is immobilized onto a large diameter, solarization-resistant fiber optic tip integrated with a portable, low-cost spectrometer for rare earth element sensing. Immobilizing the sensing material on fiber instead of dispersing the sensing material in solution offers several advantages: it facilitates solvent removal, which enhances luminescent signal from the sensitized lanthanides, and it also allows the BioMOF to be recycled for multiple uses. The sensing system was deployed on a simulated process stream and exhibited qualitative agreement with inductively-coupled plasma mass spectrometry for terbium and europium detection, highlighting the potential for the sensing system to be deployed for real-world applications. By using different sensing materials, the same portable sensor may be deployed to detect other energy relevant metals such as cobalt, providing a cost-effective and sensitive platform for critical metal characterization.
We report optical fiber diagnostics are extensively used in pulsed power experiments, such as the Sandia Z machine. However, radiation produced in a pulsed power environment can significantly affect these measurements. Catastrophic fiber darkening may be mitigated with shielding, but no flexible material can stop all radiation produced by the machine and/or target. Radiation-induced refractive index modulations are particularly challenging for optical interferometry. Several approaches for radiation-tolerant photonic Doppler velocimetry are discussed here.
Laser–plasma instabilities (LPIs) hinder the interaction of high-energy laser pulses with targets. Simulations show that broadband spectrally incoherent pulses can mitigate these instabilities. Optimizing laser operation and target interaction requires controlling the properties of these optical pulses. We demonstrate closed-loop control of the spectral density and pulse shape of nanosecond spectrally incoherent pulses after optical parametric amplification in the infrared (∼1053 nm) and sum–frequency generation to the ultraviolet (∼351 nm) using spectral and temporal modulation in the fiber front end. The high versatility of the demonstrated approaches can support the generation of high-energy, spectrally incoherent pulses by future laser facilities for improved LPI mitigation.
Graphite is a key material in a variety of cross-cutting applications in energy conversion, energy storage, and nuclear energy. Recently, temporally modulated continuous wave lasers have been shown to produce well-defined ablation features in graphite at relatively high processing speeds. In this work, we analyze in detail the laser ablation dynamics of single-pulse ablation in the sub-millisecond time regime to elucidate the origins of the resulting well-defined ablation craters using a combination of time-resolved emission imaging, diffuse reflection/scattering imaging, and optical emission spectroscopy. These multimodal in situ diagnostics revealed three main contributors to achieve well-defined ablation features: (1) rapid ejection of particles with ~100 m/s speed, (2) ablation of the graphite in the gaseous form, and (3) absence of bulk liquid motion, which is typically observed in laser processing of metals. Plasma plume formation was sustained throughout the duration of the laser pulse (500 μs). Here, this work provides insights into the complex physical and chemical mechanisms of sub-millisecond laser–matter interactions, which are critical for parameter space optimization and tailoring of laser machining and drilling processes.