Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-0IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 pm (1000 -4000 cm-') to allow high-resolution, high-speed hyperspectral imaging applications [l-51. One application will be theremote sensing of the measurement of a large number of different atmospheric gases simultaneously in the sameairmass. Due to the use of a combination of birefiingent phase retarders and multiple achromatic phase switches toachieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventionalFourier transform spectrometer but without any moving parts. In this paper, the principle of operations, systemarchitecture and recent experimental progress will be presen.

solild state imaging Fourier tranform spectrometer

Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-O IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 micron (1000-4000/cm) to allow high-resolution, high-speed hyperspectral imaging applications. One application will be the remote sensing of the measurement of a large number of different atmospheric gases simultaneously in the same airmass. Due to the use of a combination of birefringent phase retarders and multiple achromatic phase switches to achieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventional Fourier transform spectrometer but without any moving parts. In this paper, the principle of operations, system architecture and recent experimental progress will be presented.

liquid crystal achromatic phase switch

Radiant energy absorption enhancement in optical imaging systems

Reimaging system efficiently uses incident light and overcomes previous imaging detector problems. Optical system collects reflected and focal plane transmitted light and redirects it so it again impinges on focal plane in register with original image. Reimaging unabsorbed light increases light absorption and detector use probability.

Brown, R. M.

A Study of Planetary System Formation and Evolution Using a Dual Channel Adaptive Optics Imaging Polarimeter

The award I received from the Graduate Student Research Program in 2001, and the renewal award in 2002, supported the gathering and processing of my thesis data, and the presentation of my scientific results at astronomy conferences. Ultimately, this led to a successful defense of my PhD thesis. In the thesis work, I built, calibrated, and observed with the first dual imaging polarimeter ever used in series with a high order adaptive optics system and on an 8 meter class telescope. The instrument was arguably the most sensitive instrument for the high-contrast detection of the scattered light from circumstellar disks. The success of the instrument has provided the impetus for the construction of several similar simultaneous adaptive optics imaging polarimeters. In the course of the observations, a number of circumstellar disks were resolved for the first time in their scattered light, such as the disk around the classical T-tauri stars, LkCa 15 and LkHa 262. A sample of 24 young, nearby, solar-analog stars were observed with the instrument in search of the scattered light signature from debris disks around these stars. Although none of the stars revealed any obvious scattered light signatures, a meaningful limit was placed on the dust population around these stars. Also, a brown dwarf binary system was found to be a companion to one of the solar-analog stars observed, HD130948. A careful monitoring of the orbit of the binary brown dwarf will result in a dynamical mass determination of the objects, providing a valuable calibration of the physical models explaining brown dwarf evolution.

Potter, Daniel E.

Optical image of a cometary nucleus: 1980 flyby of Comet Encke

The feasibility was investigated of obtaining optical images of a cometary nucleus via a flyby of Comet Encke. A physical model of the dust cloud surrounding the nucleus was developed by using available physical data and theoretical knowledge of cometary physics. Using this model and a Mie scattering code, calculations were made of the absolute surface brightness of the dust in the line of sight of the on-board camera and the relative surface brightness of the dust compared to the nucleus. The brightness was calculated as a function of heliocentric distance and for different phase angles (sun-comet-spacecraft angle).

Wells, W. C.

Detecting X-rays with an optical imaging chamber

The light emitted by electron avalanches in a parallel plate chamber can be used to image the tracks of photoelectrons liberated by the interaction of an incident X-ray with the gas filling the chamber. The different morphologies of photoelectron tracks and minimum ionizing tracks can be used for charged particle rejection. The initial direction (before scattering) of the liberated photoelectron also contains information about the polarization of the incident radiation. We have built a small test chamber with which we have imaged photoelectron tracks using an intensified CCD camera. Our results show that optical imaging could be used in a hard X-ray imaging polarimeter useful for astronomy.

Austin, Robert A.

Optical imaging chamber for X-ray astronomy

The light emitted by electron avalanches in a parallel plate chamber can be used to image the tracks of photoelectrons liberated by the interaction of an incident X-ray with the gas filling the chamber. The differing morphologies of photoelectron tracks and high-energy charged particle tracks can be used for background rejection. The initial direction (before scattering) of the liberated photoelectron also contains information about the polarization of the incident radiation. We have built a small test chamber with which we have imaged photoelectron tracks using an intensified CCD camera. Our results show that optical imaging could be used in a hard X-ray imaging polarimeter useful for astronomy.

Austin, Robert A.

Spaceborne astronomy with electro-optical image sensors

The Space Telescope, planned for orbiting in the early 1980s, is described, with emphasis on its electro-optical image sensing capability. Relative advantages of image tubes and solid state arrays as image detectors are summarized; image tube technology is well characterized, but preference may be given to a more versatile tandem solid state array consisting of one module with high silicon response covering most of the spectrum, and a second intensified array with ultraviolet sensitivity and low noise readout. The classical 'photoelectron noise limit' calculation is reviewed, and a detailed calculation of sensitivity limits adaptable to analysis of image tube or solid state array detectors is also given. In particular, characteristics of a filter to optimize the signal to noise ratio is determined. Typical sensitivity calculations for an image tube detector show that with an exposure of one orbital night (approximately 2000 seconds), 10% photometry may be done to a low limit of visual magnitude.

Bradley, W. C.

High-speed joint-transform optical image correlator using GaAs/AlGaAs semi-insulating multiple quantum wells and diode lasers

We demonstrate a compact real-time optical image correlator using diode lasers and a semi-insulating GaAs/AlGaAs multiple-quantum-well (SI-MQW) device as the holographic element. With only 3 mW of power incident upon the SI-MQW device, the correlation is obtained in 1 microsec and can be erased in as fast as 2 microsec, which presents the possibility of a system capable of 3 x 10 exp 5 correlations/s. We also show that images can be stored for a controllable length of time (2-25 microsec), which presents possibilities for the use of the SI-MQW device as a data or image buffer memory.

Partovi, A.

Antiglare improvement for optical imaging systems

Baffle configuration provides a more efficient shade against interfering sources of illumination outside the desired field of view of optical imaging systems. It consists of a semi-ellipsoid of revolution about the minor axis with black specular reflecting surface and an aperture defined by the locus of the foci of the generating ellipse.

Davis, E. S.

Nonlinear Optical Image Processing with Bacteriorhodopsin Films

The transmission properties of some bacteriorhodopsin film spatial light modulators are uniquely suited to allow nonlinear optical image processing operations to be applied to images with multiplicative noise characteristics. A logarithmic amplitude transmission feature of the film permits the conversion of multiplicative noise to additive noise, which may then be linearly filtered out in the Fourier plane of the transformed image. The bacteriorhodopsin film displays the logarithmic amplitude response for write beam intensities spanning a dynamic range greater than 2.0 orders of magnitude. We present experimental results demonstrating the principle and capability for several different image and noise situations, including deterministic noise and speckle. Using the bacteriorhodopsin film, we successfully filter out image noise from the transformed image that cannot be removed from the original image.

Downie, John D.

Detection and Estimation of an Optical Image by Photon-Counting Techniques

Statistical description of a photoelectric detector is given. The photosensitive surface of the detector is divided into many small areas, and the moment generating function of the photo-counting statistic is derived for large time-bandwidth product. The detection of a specified optical image in the presence of the background light by using the hypothesis test is discussed. The ideal detector based on the likelihood ratio from a set of numbers of photoelectrons ejected from many small areas of the photosensitive surface is studied and compared with the threshold detector and a simple detector which is based on the likelihood ratio by counting the total number of photoelectrons from a finite area of the surface. The intensity of the image is assumed to be Gaussian distributed spatially against the uniformly distributed background light. The numerical approximation by the method of steepest descent is used, and the calculations of the reliabilities for the detectors are carried out by a digital computer.

Wang, Lily Lee

Acousto-Optic Imaging Spectrometers for Mars Surface Science

NASA's long term plan for Mars sample collection and return requires a highly streamlined approach for spectrally characterizing a landing site, documenting the mineralogical make-up of the site and guiding the collections of samples which represent the diversity of the site. Ideally, image data should be acquired at hundreds of VIS and IR wavelengths, in order to separately distinguish numerous anticipated species, using principal component analysis and linear unmixing. Cameras with bore-sighted point spectrometers can acquire spectra of isolated scene elements, but it requires 10(exp 2) to 10(exp 2) successive motions and precise relative pointing knowledge in order to create a single data cube which qualifies as a spectral map. These and other competing science objectives have to be accomplished within very short lander/rover operational lifetime (a few sols). True, 2-D imaging spectroscopy greatly speeds up the data acquisition process, since the spectra of all pixels in the scene are collected at once. This task can be accomplished with cameras that use electronically tunable acousto-optic tunable filters (AOTFs) as the optical tuning element. AOTFs made from TeO2 are now a mature technology, and operate at wavelengths from near-UV to about 5 microns. Because of incremental improvements in the last few years, present generation devices are rugged, radiation-hard and operate at temperatures down to at least 150K so they can be safely integrated into the ambient temperature optics of in-situ instruments such as planetary or small-body landers. They have been used for ground-based astronomy, and were also baselined for the ST-4 Champollion IR comet lander experiment (CIRCLE), prior to cancellation of the ST-4 mission last year. AIMS (for Acousto-optic Imaging spectrometer), is a prototype lander instrument which is being built at GSFC with support by the NASA OSS Advanced Technologies and Mission Studies, Mars Instrument Definition and Development Program (MIDP). AIMS is capable of tunable spectroscopic imaging of surface mineralogy, ices and dust between 0.5 and 2.4 microns, at a resolving power (lambda/delta lambda) which is typically several hundred. The design spatial resolution, similar to IMP and SSI, will allow mapping at scales down to about 1 cm.

Glenar, D. A.

Follow-up and Validation of K2 and TESS Planetary Systems with Keck NIRC2 Adaptive Optics Imaging

High resolution imaging (HRI) is a critical part of the transiting exoplanet follow-up and validation process. HRI allows previously unresolved stellar companions and background blends to be resolved, vetting false positive signals and improving the radii measurements of true planets. Through a multi-semester Keck NIRC2 adaptive optics imaging program, we have pursued HRI of K2 and TESS candidate planet host systems to provide the transiting exoplanet community with necessary data for system validation and characterization. Here we present a summary of our ongoing program that includes an up to date list of targets observed, a description of the observations and data reduction, and a discussion of planetary systems validated by the community using these data. This observing program has been key in NASA’s K2 and TESS missions reaching their goals of identifying new exoplanets ideal for continued follow-up observations to measure their masses and investigate their atmospheres. All observations presented here are available as calibrated images and resulting contrast curves through the Exoplanet Follow-up Observing Program (ExoFOP) website. We encourage members of the exoplanet community to use these data products in their ongoing planetary system validation and characterization efforts.

Adaptive optics

Electro-Optical Imaging Fourier-Transform Spectrometer

An electro-optical (E-O) imaging Fourier-transform spectrometer (IFTS), now under development, is a prototype of improved imaging spectrometers to be used for hyperspectral imaging, especially in the infrared spectral region. Unlike both imaging and non-imaging traditional Fourier-transform spectrometers, the E-O IFTS does not contain any moving parts. Elimination of the moving parts and the associated actuator mechanisms and supporting structures would increase reliability while enabling reductions in size and mass, relative to traditional Fourier-transform spectrometers that offer equivalent capabilities. Elimination of moving parts would also eliminate the vibrations caused by the motions of those parts. Figure 1 schematically depicts a traditional Fourier-transform spectrometer, wherein a critical time delay is varied by translating one the mirrors of a Michelson interferometer. The time-dependent optical output is a periodic representation of the input spectrum. Data characterizing the input spectrum are generated through fast-Fourier-transform (FFT) post-processing of the output in conjunction with the varying time delay.

Chao, Tien-Hsin

On optical imaging through aircraft turbulent boundary layers

Optical resolution quality as affected by aircraft turbulent boundary layers is analyzed. Wind-tunnel data was analyzed to obtained the variation of boundary layer turbulence scale length and mass density rms fluctuations with Mach number. The data gave good agreement with a mass density fluctuation turbulence spectrum that is either isotropic of orthogonally anisotropic. The data did not match an isotropic turbulence velocity spectrum which causes an anisotropic non-orthogonal mass density fluctuation spectrum. The results indicate that the average mass density rms fluctuation is about 10% of the maximum mass density across the boundary layer and that the transverse turbulence scale size is about 10% of the boundary layer thickness. The results indicate that the effect of the turbulent boundary layer is large angle scattering which decreases contrast but not resolution. Using extinction as a criteria the range of acceptable aircraft operating conditions are given.

Sutton, G. W.

Accuracy requirements of optical linear algebra processors in adaptive optics imaging systems

The accuracy requirements of optical processors in adaptive optics systems are determined by estimating the required accuracy in a general optical linear algebra processor (OLAP) that results in a smaller average residual aberration than that achieved with a conventional electronic digital processor with some specific computation speed. Special attention is given to an error analysis of a general OLAP with regard to the residual aberration that is created in an adaptive mirror system by the inaccuracies of the processor, and to the effect of computational speed of an electronic processor on the correction. Results are presented on the ability of an OLAP to compete with a digital processor in various situations.

Downie, John D.

Optical imaging and long-slit spectroscopy of Markarian galaxies with multiple nuclei. I - Basic data

Optical CCD images and long-slit spectroscopic data are presented for over 100 Markarian (UV-excess) galaxies reported in early studies to possess multiple optical nuclei or extreme morphological peculiarities suggestive of galaxy collisions and mergers. Stacked broad-band images are presented with histogram equalization in order to show simultaneously the nuclei and features at very low surface-brightness levels. Morphological properties, luminosities and colors of the integral systems are given. Photometric and image properties of over 200 individual nuclei and giant H II regions have been measured with respect to the local backgrounds in the galaxies using an objective image finding algorithm. Labeled contour plots identify the measured subcomponents. Two-dimensional spectral data are presented, in addition to intensity profiles along the slit in the light of H-alpha + forbidden N II emission lines and adjacent continuum. Nuclear emission-line measurements, reddening estimates, monochromatic continuum magnitudes, and colors are given.