Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical thermometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Automated bubble analysis of high-speed subcooled flow boiling images using U-net transfer learning and global optical flow

Capturing and analyzing the bubble dynamics is crucial to improving the understanding of boiling heat transfer mechanisms and predicting boiling heat transfer coefficient and boiling crisis. High speed video (HSV) imaging has been used for decades towards this end. Still, there is no universal approach to quantitatively analyze bubble dynamics from HSV images. In this study, we propose a data-driven post-processing approach to segment, track, and identify wall-attached vapor bubbles from HSV images of the boiling process in subcooled flow conditions. Firstly, we employ a transfer learning framework with a U-Net-based convolution neural network (CNN) architecture to detect and segment bubbles in HSV images of diverse contrast and surface texture using very little data (e.g., 10 images) for training. Then, we evaluate the trained CNN model with 100 ground-truth images, and the validation results show that the model accuracy and precision in detecting the optical footprint of bubbles are higher than 90%. Finally, we suggest a criterion to identify a condensing bubble based on the divergence of the bubble displacement, which is calculated from sequential segmented bubble images using a global optical flow code. Using this combination of machine learning and optical flow, we can identify nucleation sites and track the growth of bubbles nucleating at each site to quantify nucleation site density, nucleation frequency, and other fundamental boiling parameters. The proposed system is validated using results obtained on a special heater, which enables both infrared (IR) thermometry and HSV imaging on a metallic surface. We compare the fundamental boiling parameters obtained by the two different diagnostics. The results show good agreement. In conclusion, the difference between the measurements of nucleation site density, averaged nucleation frequency, and averaged growth time performed with the two techniques is always within ± 20% and mostly ± 10% of the values measured with IR thermometry.

42 ENGINEERING↗

Post-detonation fireball thermometry via femtosecond-picosecond coherent anti-Stokes Raman Scattering (CARS)

Accurate knowledge of post-detonation fireball temperatures is important for understanding device performance and for validation of numerical models. Such measurements are difficult to make even under controlled laboratory conditions. Here, temperature measurements were performed in the fireball of a commercial detonator (RP-80, Teledyne RISI). The explosion and fragments were contained in a plastic enclosure with glass windows for optical access. A hybrid femtosecond-picosecond (fs-ps) rotational coherent anti-Stokes Raman scattering (CARS) instrument was used to perform gas-phase thermometry along a one-dimensional measurement volume in a single laser shot. The 13-mm-thick windows on the explosive-containment housing introduced significant nonlinear chirp on the fs lasers pulses, which reduced the Raman excitation bandwidth and did not allow for efficient excitation of high-J Raman transitions populated at flame temperatures. To overcome this, distinct pump and Stokes pulses were used in conjunction with spectral focusing, achieved by varying the relative timing between the pump and Stokes pulses to preferentially excite Raman transitions relevant to flame thermometry. Light scattering from particulate matter and solid fragments was a significant challenge and was mitigated using a new polarization scheme to isolate the CARS signal. Fireball temperatures were measured 35–40 mm above the detonator, 12–25 mm radially outward from the detonator centerline, and at 18 and 28 µs after initiation. At these locations and times, significant mixing between the detonation products and ambient air had occurred thus increasing the nitrogen-based CARS thermometry signal. Initial measurements show a distribution of fireball temperatures in the range 300–2000 K with higher temperatures occurring 28 µs after detonation.

42 ENGINEERING↗

Development of A Multi-Spectral Pyrometry Sensor for High-Speed Transient Surface-Temperature Measurements in Combustion-Relevant Harsh Environments

Accurate and high-speed transient surface-temperature measurements of combustion devices including internal combustion (IC) engines, gas turbines, etc., provide validation targets and boundary conditions for computational fluid dynamics models, and are broadly relevant to technology advancements such as performance improvement and emissions reduction. Development and demonstration of a multi-infrared-channel pyrometry-based optical instrument for high-speed surface-temperature measurement is described. The measurement principle is based on multi-spectral radiation thermometry (MRT) and uses surface thermal radiation at four discrete spectral regions and a corresponding emissivity model to obtain surface temperature via non-linear least squares (NLLS) optimization. Rules of thumb for specifying the spectral regions and considerations to avoid interference with common combustion products are developed; the impact of these along with linear and non-linear MRT analysis are assessed as a function of temperature and signal-to-noise ratio. A multi-start method to determine the MRT-solution global optimum is described and demonstrated. The resulting multi-channel transient pyrometry instrument is described along with practical considerations including optical-alignment drift, matching intra-channel transient response, and solution-confidence indicators. The instrument demonstrated excellent >97% accuracy and >99% 2-sigma precision over the 400–800 °C range, with ~20 µs (50 kHz, equivalent to 0.2 cad at 2000 RPM IC-engine operation) transient response in the bench validation.

47 OTHER INSTRUMENTATION↗

Temperature-dependent x-ray fluorescent response from thermographic phosphors under x-ray excitation

Phosphor thermometry has been successfully applied within several challenging environments. Typically, the thermographic phosphors are excited by an ultraviolet light source, and the temperature-dependent spectral or temporal response is measured. However, this is challenging or impossible in optically thick environments. In addition, emission from other sources (e.g., a flame) may interfere with the optical phosphor emission. Furthermore, a temperature dependent x-ray excitation/emission could alleviate these issues as x-rays could penetrate obscurants with no interference from flame luminosity. In addition, x-ray emission could allow for thermometry within solids while simultaneously x-ray imaging the structural evolution. In this study, select thermographic phosphors were excited via x-ray radiation, and their x-ray emission characteristics were measured at various temperatures. Several of the phosphors showed varying levels of temperature dependence with the strongest sensitivity occurring for YAG:Dy and ZnGa 2 O 4 :Mn. This approach opens a path for less intrusive temperature measurements, particularly in optically opaque multiphase and solid phase combustion environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of liquid-phase thermometry in impinging jet sprays using synchrotron x-ray scattering

Liquid thermometry during primary and secondary breakup of liquid sprays is challenging due to the presence of highly dynamic, optically complex flow features. This work evaluates the use of x-ray scattering from a focused, monochromatic beam of the Advanced Photon Source at Argonne National Laboratory for the measurement of liquid temperatures within the mixing zone of an impinging jet spray. The measured scattering profiles are converted to temperature through a previously developed two-component partial least squares (PLS) regression model. Transmitive mixing during jet merging is inferred through spatial mapping of temperatures within the impingement region. In this work, the technique exhibits uncertainties of ±2K in temperature and 2% in capturing the correct scattering profile, showing its potential utility for probing liquid temperature distributions in multiphase flows.

42 ENGINEERING↗

The impact of 2 H 9/2 → 4 I 13/2 emission from Er 3+ ions on ratiometric optical temperature sensing with Yb 3+ /Er 3+ co-doped upconversion materials

Yb 3+ /Er 3+ co-doped upconversion materials are widely used for luminescence intensity ratio (LIR) thermometry, where the relative intensity ratio of the green luminescence transitions ( 2 H 11/2 4 I 15/2 and 4 S 3/2 4 I 15/2 ) of Er 3+ dopant ions changes with temperature. In this work we report on the impact of an additional transition from the 2 H 9/2 level to the intermediate 4 I 13/2 level, which overlaps with the green luminescence normally used for LIR thermometry. The 2 H 9/2 4 I 13/2 emission overlaps extensively with the 4 S 3/2 4 I 15/2 emission and is more sensitive to pump power. The wavelength intervals used to integrate both 2 H 11/2 4 I 15/2 and 4 S 3/2 4 I 15/2 luminescence need be selected carefully in order to achieve accurate temperature readouts.

36 MATERIALS SCIENCE↗

Optical radiation measurements II; Proceedings of the Meeting, Orlando, FL, Mar. 27, 28, 1989

The present conference discusses topics in the characterization of imaging radiometers, laboratory instrumentation, field and spacecraft instrumentation, and quantum and thermal standard detectors. Attention is given to UV radiometric imaging, dual-color radiometer imagery, a novel diode-array radiometer, a novel reference spectrophotometer, radiance calibration of spherical integrators, instrumentation for measurement of spectral goniometric reflectance, and a real-time IR background discrimination radiometer. Also discussed are a multichannel radiometer for atmosphere optical property measurements, the UV spectroradiometric output of a turbojet, characterizations of the Earth Radiation Budget Experiment scanning radiometers, total-radiation thermometry, future directions in Si photodiode self-calibration, and radiometric quality Ge photodiodes.

Palmer, James M.↗

Equation of State and Thermometry of the 2D SU ( N ) Fermi-Hubbard Model

We characterize the equation of state (EoS) of the SU ( N > 2 ) Fermi-Hubbard Model (FHM) in a two-dimensional single-layer square optical lattice. We probe the density and the site occupation probabilities as functions of interaction strength and temperature for N = 3 , 4, and 6. Our measurements are used as a benchmark for state-of-the-art numerical methods including determinantal quantum Monte Carlo and numerical linked cluster expansion. By probing the density fluctuations, we compare temperatures determined in a model-independent way by fitting measurements to numerically calculated EoS results, making this a particularly interesting new step in the exploration and characterization of the SU ( N ) FHM. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescence spectroscopy and thermometry for hypersonic flight research

The present study, which has demonstrated the feasibility of using time-resolved laser-induced fluorescence methods to ascertain boundary layer temperature distributions in real time for hypersonic vehicles in atmospheric flight, employs conventional optics in combination with novel time-resolved spectroscopy. The radiative lifetime and signal intensity involved, both of which are reduced by quenching, are adequate for measurement with state-of-the-art time-resolved fluorescence techniques, except for certain conditions associated with both the highest speeds and the lowest altitudes.

Thompson, B. E.↗

Post-Irradiation Examination on MiniFuel UCO and UO 2 TRISO Particles Irradiated in HFIR at High Power

Post-irradiation examination (PIE) of MiniFuel compacts was conducted at Oak Ridge National Laboratory (ORNL) under the Nuclear Science User Facilities project in collaboration with Kairos Power (KP) to evaluate the performance of tristructural-isotropic (TRISO) particles under high particle power and fluoride-salt-cooled high-temperature reactor (FHR)-relevant conditions. MiniFuel compacts containing low-enriched uranium oxide-uranium carbide (LEUCO), low-enriched uranium dioxide (LEUO2), and natural UCO (NUCO) kernels were irradiated for four cycles at ORNL’s High Flux Isotope Reactor (HFIR) at target temperatures between 500°C and 900°C. Post irradiation, the experiment was disassembled at ORNL to recover the MiniFuel subcapsules, which were subsequently punctured to measure fission gas release. Subcapsule disassembly allowed the recovery of components of interest, such as silicon carbide (SiC) thermometry, fuel specimens, fission product sinks, and SiC spacers. The experimental irradiation temperature was confirmed by analyzing the SiC thermometry via dilatometry. PIE on the fuel specimens included gamma spectrometry and deconsolidation leach burn leach, which were complemented by imaging techniques such as x-ray computed tomography, optical microscopy, and electron microscopy. The PIE results provide insight into TRISO particle integrity, fission product retention, coating performance, and kernel migration, informing fuel qualification for application in KP’s FHR concept.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Post-Irradiation Examination on MiniFuel UCO and UO 2 TRISO Particles Irradiated in HFIR at High Power

Post-irradiation examination (PIE) of MiniFuel compacts was conducted at Oak Ridge National Laboratory (ORNL) under the Nuclear Science User Facilities project in collaboration with Kairos Power (KP) to evaluate the performance of tristructural-isotropic (TRISO) particles under high particle power and fluoride-salt-cooled high-temperature reactor (FHR)-relevant conditions. MiniFuel compacts containing low-enriched uranium oxide-uranium carbide (LEUCO), low-enriched uranium dioxide (LEUO 2 ), and natural UCO (NUCO) kernels were irradiated for four cycles at ORNL’s High Flux Isotope Reactor (HFIR) at target temperatures between 500°C and 900°C. Post irradiation, the experiment was disassembled at ORNL to recover the MiniFuel subcapsules, which were subsequently punctured to measure fission gas release. Subcapsule disassembly allowed the recovery of components of interest, such as silicon carbide (SiC) thermometry, fuel specimens, fission product sinks, and SiC spacers. The experimental irradiation temperature was confirmed by analyzing the SiC thermometry via dilatometry. PIE on the fuel specimens included gamma spectrometry and deconsolidation leach burn leach, which were complemented by imaging techniques such as x-ray computed tomography, optical microscopy, and electron microscopy. The PIE results provide insight into TRISO particle integrity, fission product retention, coating performance, and kernel migration, informing fuel qualification for application in KP’s FHR concept.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation thermometry: The measurement problem

An overview of the theory and techniques of radiometric thermometry is presented. The characteristics of thermal radiators (targets) are discussed along with surface roughness and oxidation effects, fresnel reflection and subsurface effects in dielectrics. The effects of the optical medium between the radiating target and the radiation thermometer are characterized including atmospheric effects, ambient temperature and dust environment effects and the influence of measurement windows. The optical and photodetection components of radiation thermometers are described and techniques for the correction of emissivity effects are addressed.

Nutter, G. D.↗

Microstructure dependent shear localization in 316L SS

Shear localization is characterized by the concentration of plastic deformation within narrow bands of material and constitutes the precursor to failure in materials subjected to high strain rates. These bands have been observed experimentally, but classical continuum material models have not been able to fully capture their development. The aim of this research is to investigate the role of microstructural differences in the dynamic shear response of wrought and additively manufactured (AM) 316L SS. Compact Forced Simple Shear specimens for Digital Image Correlation (CFSS-DIC) of wrought and additively manufactured 316L SS were tested on a Split Hopkinson Pressure Bar (SHPB) in conjunction with infrared thermometry measurements. Results indicate that the microstructures of wrought and AM 316L SS exhibit differences that affect the shear response of this materials. In conclusion, CFSS-DIC samples tested on the SHPB did not exhibit recrystallization inside the shear region, fact confirmed by thermometry measurements.

36 MATERIALS SCIENCE↗

One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

Extending in situ X-ray Temperature Diagnostics to Internal Components

Time-resolved X-ray thermometry is an enabling technology for measuring temperature and phase change of components. However, current diagnostic methods are limited in their ability due to the invasive nature of probes or the requirement of coatings and optical access to the component. Our proposed developments overcome these challenges by utilizing X-rays to directly measure the objects temperature. Variable-Temperature X-ray Diffraction (VT-XRD) was performed over a wide range of temperatures and diffraction angles and was performed on several materials to analyze the patterns of the bulk materials for sensitivity. "High-speed" VT-XRD was then performed for a single material over a small range of diffraction angles to see how fast the experiments could be performed, whilst still maintaining peaks sufficiently large enough for analysis.

36 MATERIALS SCIENCE↗

Single-pulse broad-band rotational CARS thermometry of cold N2 gas

Coherent anti Stokes Raman scattering (CARS) from the pure rotational Raman lines of N2 was employed to measure the instantaneous (10 nsec) rotational temperature of the gas at room temperature and below. An entire rotational CARS spectrum was generated by a single laser pulse using a broad bandwidth dye laser and was recorded on an optical multichannel analyzer. A best fit temperature obtained for individual experimental spectra by comparison with calculated spectra. Good agreement between CARS temperatures and thermocouple temperatures was observed.

Chang, R. K.↗