Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical tolerances”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Impact of shorter wavelengths on optical quality for laws

This study explores parametrically as a function of wavelength the degrading effects of several common optical aberrations (defocus, astigmatism, wavefronttilts, etc.), using the heterodyne mixing efficiency factor as the merit function. A 60 cm diameter aperture beam expander with an expansion ratio of 15:1 and a primary mirror focal ratio of f/2 was designed for the study. An HDOS copyrighted analysis program determined the value of merit function for various optical misalignments. With sensitivities provided by the analysis, preliminary error budget and tolerance allocations were made for potential optical wavefront errors and boresight errors during laser shot transit time. These were compared with the baseline 1.5 m CO2 laws and the optical fabrication state of the art (SOA) as characterized by the Hubble Space Telescope. Reducing wavelength and changing optical design resulted in optical quality tolerances within the SOA both at 2 and 1 micrometer. However, advanced sensing and control devices would be necessary to be tightened by a factory of 1.8 for a 2 micrometer system and by 3.6 for a 1 micrometer system relative to the baseline CO2 LAWS. Available SOA components could be used for operation at 2 micrometers but operation at 1 micrometer does not appear feasible.

Wissinger, Alan B.↗

Control of optical performance on the Space Telescope

A large astronomical telescope, termed the Space Telescope, is expected to be placed in orbit in the early 1980's. It will be operated as an international observatory that will enable astronomers to detect electromagnetic radiation over a much broader spectrum than is possible from ground observatories. The image quality (not degraded by atmospheric effects) will be limited only by the quality of the optics and by aperture diffraction. This opportunity to approach diffraction-limited imagery on an astronomical telescope of this size (2.4-m aperture) sets unusually stringent tolerances on the optical quality. The budgeting and control of these qualities throughout the design, fabrication, assembly, and operation of the Space Telescope is described. A feedback control system which will maintain the telescope at peak performance in the orbital environment is examined.

Jones, C. O.↗

Fault-tolerance techniques for high-speed fiber-optic networks

Four fiber optic network topologies (linear bus, ring, central star, and distributed star) are discussed relative to their application to high data throughput, fault tolerant networks. The topologies are also examined in terms of redundancy and the need to provide for single point, failure free (or better) system operation. Linear bus topology, although traditionally the method of choice for wire systems, presents implementation problems when larger fiber optic systems are considered. Ring topology works well for high speed systems when coupled with a token passing protocol, but it requires a significant increase in protocol complexity to manage system reconfiguration due to ring and node failures. Star topologies offer a natural fault tolerance, without added protocol complexity, while still providing high data throughput capability.

Deruiter, John↗

Wide field/planetary camera optics study

Design feasibility of the baseline optical design concept was established for the wide field/planetary camera (WF/PC) and will be used with the space telescope (ST) to obtain high angular resolution astronomical information over a wide field. The design concept employs internal optics to relay the ST image to a CCD detector system. Optical design performance predictions, sensitivity and tolerance analyses, manufacturability of the optical components, and acceptance testing of the two mirror Cassegrain relays are discussed.

Source record↗

Focal Plane Alignment Utilizing Optical CMM

In many applications, an optical detector has to be located relative to mechanical reference points. One solution is to specify stringent requirements on (1) mounting the optical detector relative to the chip carrier, (2) soldering the chip carrier onto the printed circuit board (PCB), and (3) installing the PCB to the mechanical structure of the subsystem. Figure 1 shows a sketch of an optical detector mounted relative to mechanical reference with high positional accuracy. The optical detector is typically a fragile wafer that cannot be physically touched by any measurement tool. An optical coordinate measuring machine (CMM) can be used to position optical detectors relative to mechanical reference points. This approach will eliminate all requirements on positional tolerances. The only requirement is that the PCB is manufactured with oversized holes. An exaggerated sketch of this situation is shown in Figure 2. The sketch shows very loose tolerances on mounting the optical detector in the chip carrier, loose tolerance on soldering the chip carrier to the PCB, and finally large tolerance on where the mounting screws are located. The PCB is held with large screws and oversized holes. The PCB is mounted loosely so it can move freely around. The optical CMM measures the mechanical reference points. Based on these measurements, the required positions of the optical detector corners can be calculated. The optical CMM is commanded to go to the position where one detector corner is supposed to be. This is indicated with the cross-hairs in Figure 2(a). This figure is representative of the image of the optical CMM monitor. Using a suitable tapping tool, the PCB is manually tapped around until the corner of the optical detector is at the crosshairs of the optical CMM. The CMM is commanded to another corner, and the process is repeated a number of times until all corners of the optical detector are within a distance of 10 to 30 microns of the required position. The situation is sketched in Figure 2(b) (the figure also shows the tapping tool and where to tap). At this point the fasteners for the PCB are torqued slightly so the PCB can still move. The PCB location is adjusted again with the tapping tool. This process is repeated 3 to 4 times until the final torque is achieved. The oversized mounting holes are then filled with a liquid bonding agent to secure the board in position (not shown in the sketch). A 10- to 30-micron mounting accuracy has been achieved utilizing this method..

Liebe, Carl Christian↗

Optical Design of the Extreme Coronagraph for Living Planetary Systems Instrument for the LUVOIR Mission Study

The large UV/optical/IR surveyor (LUVOIR) is a concept for a highly capable, multiwavelength space observatory with ambitious science goals. Finding and characterizing a wide range of exoplanets, including those that might be habitable, is a major goal of the study. The ambitious science goals drive the challenges of optical design. This paper will present how the optical design meets the unique challenges for coronagraphs on large telescopes to achieve high contrast for a wide wavelength range from 200 to 2000 nm. Some of these unique challenges include the position and size of occulter masks, deformable mirror placement and separation, tight tolerances on the optical system and each element, and finally, packaging all instruments in a limited space. Three types of modules are designed after the coronagraph to explore the exoplanets and analyze the spectrum of detected exoplanet signals: two imaging cameras, two integral field spectrographs, and one high-resolution spectrometer. All of them work together to provide information to meet scientific challenges in searching for habitable planets. The optical designs, unique challenges, and the solutions for all coronagraph and spectral modules are presented. Their specifications derived from science goals are also presented.

Qian Gong↗

Optical design of the Extreme Coronagraph for Living Planetary Systems instrument for the LUVOIR mission study

The large UV/optical/IR surveyor (LUVOIR) is a concept for a highly capable, multiwavelength space observatory with ambitious science goals. Finding and characterizing a wide range of exoplanets, including those that might be habitable, is a major goal of the study. The ambitious science goals drive the challenges of optical design. This paper will present how the optical design meets the unique challenges for coronagraphs on large telescopes to achieve high contrast for a wide wavelength range from 200 to 2000 nm. Some of these unique challenges include the position and size of occulter masks, deformable mirror placement and separation, tight tolerances on the optical system and each element, and finally, packaging all instruments in a limited space. Three types of modules are designed after the coronagraph to explore the exoplanets and analyze the spectrum of detected exoplanet signals: two imaging cameras, two integral field spectrographs, and one high-resolution spectrometer. All of them work together to provide information to meet scientific challenges in searching for habitable planets. The optical designs, unique challenges, and the solutions for all coronagraph and spectral modules are presented. Their specifications derived from science goals are also presented.

Qian Gong↗

A low maintenance and highly reliable fly-by-light architecture

This paper proposes a highly reliable distributed architecture for use in a commercial transport. Fly-By-Light characteristics of the architecture are a serial fiber optic backplane and redundant fiber optic data bus. The fiber optic bus is fault tolerant and Byzantine resilient. A distributed architecture (both physically and logically) can be realized by utilizing several processing clusters on the data bus. A processing cluster is composed of one or more processing units. The processing units consist of several modules. The modules of the processing unit are connected via a serial fiber optic backplane. Fault tolerance is implemented at the backplane to increase reliability and availability.

Dan Palumbo↗

Lifetime Assessment of the NEXT Ion Thruster

Ion thrusters are low thrust, high specific impulse devices with required operational lifetimes on the order of 10,000 to 100,000 hr. The NEXT ion thruster is the latest generation of ion thrusters under development. The NEXT ion thruster currently has a qualification level propellant throughput requirement of 450 kg of xenon, which corresponds to roughly 22,000 hr of operation at the highest throttling point. Currently, a NEXT engineering model ion thruster with prototype model ion optics is undergoing a long duration test to determine wear characteristics and establish propellant throughput capability. The NEXT thruster includes many improvements over previous generations of ion thrusters, but two of its component improvements have a larger effect on thruster lifetime. These include the ion optics with tighter tolerances, a masked region and better gap control, and the discharge cathode keeper material change to graphite. Data from the NEXT 2000 hr wear test, the NEXT long duration test, and further analysis is used to determine the expected lifetime of the NEXT ion thruster. This paper will review the predictions for all of the anticipated failure mechanisms. The mechanisms will include wear of the ion optics and cathode s orifice plate and keeper from the plasma, depletion of low work function material in each cathode s insert, and spalling of material in the discharge chamber leading to arcing. Based on the analysis of the NEXT ion thruster, the first failure mode for operation above a specific impulse of 2000 sec is expected to be the structural failure of the ion optics at 750 kg of propellant throughput, 1.7 times the qualification requirement. An assessment based on mission analyses for operation below a specific impulse of 2000 sec indicates that the NEXT thruster is capable of double the propellant throughput required by these missions.

VanNoord, Jonathan L.↗

PACE OCI Short-Wave Infrared Detection Assembly Optical System Design, Alignment, and Environmental Test

The Ocean Color Instrument (OCI), which will be integrated with the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) satellite, will collect science data that will be used to monitor the health of Earth’s oceans and atmosphere. The Short-Wave Infrared (SWIR) Detection Assembly (SDA), built and characterized by Utah State University Space Dynamics Laboratory (SDL), is a subsystem of OCI consisting of 32 channels covering seven discrete optical bands of interest. A total of 16 SWIR Detection Subassemblies (SDSs) compose the SDA and house the cold optical system. The science data optical input for each SDS is supplied by a 0.22 NA multimode fiber interfacing with a fiber adapter. The diverging light from the fiber is collimated, split by a dichroic beamsplitter to two separate channels, filtered by the science filter, and then reimaged onto the single-element detectors with a final 0.76 NA. Aspheric, diamond-turned powered elements are used throughout the optical design. Fabrication and alignment tolerance analysis/budgets are balanced to ensure the optical system meets throughput requirements. All systems are aligned at ambient temperature using an InSb camera and an in-line illumination microscope system to directly image the active detector area through the science filters. Compensators used during alignment are detector focus and decenter, which are adjusted via photoetched shims in increments of 25 µm. Average focus and centering errors were less than 8 µm among all 32 flight and 10 flight spare detectors. Each SDS spectral response and conversion gain was verified at operational temperature of -65°C in vacuum.

OCI↗

Theoretical analysis of segmented Wolter/LSM X-ray telescope systems

The Segmented Wolter I/LSM X-ray Telescope, which consists of a Wolter I Telescope with a tilted, off-axis convex spherical Layered Synthetic Microstructure (LSM) optics placed near the primary focus to accommodate multiple off-axis detectors, has been analyzed. The Skylab ATM Experiment S056 Wolter I telescope and the Stanford/MSFC nested Wolter-Schwarzschild x-ray telescope have been considered as the primary optics. A ray trace analysis has been performed to calculate the RMS blur circle radius, point spread function (PSF), the meridional and sagittal line functions (LST), and the full width half maximum (PWHM) of the PSF to study the spatial resolution of the system. The effects on resolution of defocussing the image plane, tilting and decentrating of the multilayer (LSM) optics have also been investigated to give the mounting and alignment tolerances of the LSM optic. Comparison has been made between the performance of the segmented Wolter/LSM optical system and that of the Spectral Slicing X-ray Telescope (SSXRT) systems.

Shealy, D. L.↗

Elastic Surface Wrinkling

Instability phenomena in elastic surfaces subject to compressive stresses are examined theoretically in new report. Theory is potentially applicable to such practical problems as aircraft panel flutter, nondestructive testing, piezoelectric transducer design, distortion of optical surfaces, and tolerance studies of very precise machine parts.

Zak, M.↗

Zone plate lens antennas for millimeter and submillimeter wavelengths

Zone plate lenses are a type of focusing element which function essentially as differential phase shifters, having a relatively few, coarsely quantized phase delays across the incident beam of radiation. The major advantages are ease of fabrication and much reduced thickness, compared to conventional refractive focusing elements. These considerations are both of particular importance for the submillimeter range, in which manufacturing tolerances for curved optical elements can pose significant problems, and where the absorption of readily available dielectric materials is quite large. In this presentation we briefly review the theory of zone plate lens operations, present a relatively simple method for calculating the aperture efficiency of zone plate lenses used as antennas, and show some theoretical and measured results in the 100 GHz range.

Goldsmith, Paul F.↗

System identification of the JPL micro-precision interferometer truss - Test-analysis reconciliation

The JPL Micro-Precision Interferometer (MPI) is a testbed for studying the use of control-structure interaction technology in the design of space-based interferometers. A layered control architecture will be employed to regulate the interferometer optical system to tolerances in the nanometer range. An important aspect of designing and implementing the control schemes for such a system is the need for high fidelity, test-verified analytical structural models. This paper focuses on one aspect of the effort to produce such a model for the MPI structure, test-analysis model reconciliation. Pretest analysis, modal testing, and model refinement results are summarized for a series of tests at both the component and full system levels.

Red-Horse, J. R.↗

The Space Mobile Network

The definition and development of the next generation space communications and navigation architecture is underway. The primary goals are to remove communications and navigations constraints from missions and to enable increased autonomy. The Space Mobile Network (SMN) is an architectural concept that includes new technology and operations that will provide flight systems with an similar user experience to terrestrial wireless mobile networks. This talk will describe the SMN and its proposed new features, such as Disruption Tolerant Networking (DTN), optical communications, and User Initiated Services (UIS).

Spacecraft Communications↗