Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscilloscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

50 records · Page 3

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗

Improving Chirped Fiber Bragg Grating Resolution for Position-Sensitive Sensors in Shock- and Detonation-Driven Experiments

Chirped fiber Bragg gratings (CFBGs) are robust diagnostic sensors that are widely used to track detonation-driven and shock wave propagation. CFBGs are inscribed with a linearly chirped periodic index of refraction changes that alter the Bragg wavelength along the length of the probe. The light return of each individual Bragg element is captured by a detector at a unique time to map the full reflected spectrum. The CFBG spectrum is measured with a dispersive Fourier transform of the reflected light that temporally stretches the spectrum to increase spatial resolution and make a one-to-one map of the wavelength on a time axis. Here, we propose an improvement of CFBG temporal resolution by incorporating two co-linear laser pulses with orthogonal polarization states and a 5 ns time offset. The two separate signals were split and tracked by two separate detectors. An oscilloscope captured good separation in the signals, and two separate spectrograms were generated and interleaved in the post-processing of the data. This novel technique doubled the CFBG temporal resolution and led to a doubled location resolution. As a proof-of-concept of this technique, the resolution improvement was compared between standard CFBG measurements and the two polarization states method on a position-sensitive CFBG sensor. CFBG resolution doubling will advance sensor capabilities and will have a direct impact on improving capture and analysis in dynamic, high-explosive experiments.

42 ENGINEERING↗

MESOSCALE THERMAL TRANSPORT MEASUREMENTS OF MULTI-PHASE AND POROUS NUCLEAR FUELS USING A SQUARE-WAVE PULSE THERMOREFLECTANCE TECHNIQUE

The safe and efficient operation of nuclear reactors require accurate knowledge of peak temperatures in the fuel assemblies. The temperature profiles are governed by the thermal transport properties of the fuel, namely the thermal conductivities (k) and thermal diffusivities (D). These values can be very difficult to measure as they are known to vary considerably from the measured bulk values of the fresh fuel, and quickly degrade with increasing burnup [1 -3] . Laser-based techniques have been effectively used for non-destructive and non-contact thermal transport measurements of a wide variety of materials, including nuclear materials [4-6] that would otherwise prove too hazardous or difficult to measure otherwise. In this study, a new thermoreflectance technique known as square-pulse transient thermoreflectance (SPTR) is described and used to determine the mesoscale thermal diffusivity of both uranium sesquisilicide (U3Si2) and uranium nitride (UN) phases in a composite fuel with micron level spatial resolution [7]. This technique employs a rapid train of square-wave pulses from an excitation laser to create a periodic heat flux on a gold coated sample surface. Surface adsorption results in transient film temperatures and hence rapid fluctuations in thermoreflectance that can be measured via a detection laser coupled with a digital oscilloscope. The lasers are coaxially focused on the sample surface, allowing for a sample measurement area of a single convolved laser spot size (~2 µm). A sensitivity analysis was conducted to identify key measurement parameters of this technique using reference materials with a range of thermal conductivities comparable to those of both ceramic, composite, and metal nuclear fuel types (1.4 – 27.2 W/m-K). The reference materials were measured using the new technique as well as a spatial-domain thermoreflectance technique (SDTR) previously reported for a comparison [8]. Additionally, measurements of several U3Si2 and UN phase regions of a polished UN/U3Si2 (70/30 vol.%) sample were taken, and the resulting calculated D values are reported, with both techniques showing excellent agreement between samples. This technique was used to scan a multiphase region at 5 micron increments to generate a local diffusivity map, demonstrating the utility of the techniques for measuring thermal transport properties in specimens with precipitates and secondary phases. Furthermore, the technique is currently being applied to measure thermal properties of Fast Flux Test Reactor (FFTR) irradiated metal fuel specimens whose porous microstructure make it very difficult to measure using other techniques. Comparison of the local scale measurements are compared with the pre-irradiated fuel samples to show the degradation of thermal transport in fuels due to pores from fission gas bubbles and other irradiation induced defects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Short pulsewidth high repetition rate nanosecond transient absorption spectrometer

A high-sensitivity nanosecond to millisecond transient absorption spectrometer for measurements of miniscule signals under low excitation intensities includes an excitation source generating a >100 Hz, <5 ns pulsewidth excitation pulse for exciting a light absorbing sample, a probe light source for generating a high photon flux probe light beam producing an average irradiance greater than 1 μW m-2 nm-1 for measuring the transient absorption spectrum of the sample before and after excitation by the excitation source, a DC-coupled detector capable of measuring light for enabling synchronous measurement of both the transmission of the probe light beam and the change in transmission of the probe light beam between a signal with the excitation pulse present and a signal in the absence of the excitation pulse, and a digital oscilloscope with a trigger rearm time capable of collecting every trigger event at frequencies including 1MHz, for enabling sequential noise subtraction protocols.

Rimshaw, Adam↗

Parallel Grid-Forming Inverter-Driven Black Start: Power-Hardware-in-the-Loop Validation: Preprint

With power systems encountering increasing deployment levels of inverter-based resources (IBRs), system restoration using grid-forming (GFM) IBRs has gained attention. Engineered to establish grid voltages in the absence of a stiff grid, black-start-capable GFM IBRs are expected to enhance power system resilience by playing a critical role in bottom-up system restoration. This paper experimentally studies the feasibility of the novel approach through power-hardware-in-the-loop (PHIL) testing and validation with a commercial GFM inverter. The PHIL test setup demonstrates an inverter-driven black start of a 5-MW unbalanced distribution feeder where two GFM inverters collectively black start the feeder: one is a commercial hardware GFM inverter interacting through the PHIL interface, and the other is a software GFM emulated by a real-time simulation with full electromagnetic transient (EMT) models. Both GFM inverters are equipped with negative-sequence voltage control to suppress the voltage imbalance resulting from the unbalanced loading, allowing us to study the dynamic interactions between the GFMs with their control parameters unknown. To evaluate the dynamic behavior of the GFM inverters under the entire black-start process, the EMT model of the distribution system details the transformer and motor dynamics to emulate their inrush and startup behaviors. It abstracts conventional grid-connected inverter dynamics, i.e., grid-following inverters. Oscilloscope measurements of the hardware GFM inverter are also presented for critical steps. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Development and Testing of a new Current-Regulated Arc Modulator for the LINAC

In this study, the performance of a current-regulated arc modulator was investigated with a focus on its role in initiating and sustaining plasma discharge within the Magnetron Body of the LINAC system. The analysis centered on how switching components, circuit topology, and feedback loop architecture influence critical factors such as energy efficiency, discharge stability, and long-term plasma containment. Particular attention was given to variations in pulse termination behavior, as observed through oscilloscope traces, which revealed inconsistencies affecting the duty factor and cathode temperature. These fluctuations have downstream effects on the cesium-coated cathode surface, thereby impacting H⁻ ion production and beam reliability. Simulation-based testing in LTspice was used to evaluate noise suppression techniques and arc current regulation schemes, revealing how optimized snubber networks, improved pulse shaping, and feedback stability can mitigate modulator-induced noise. The results identified hardware level parameters that significantly enhance discharge repeatability and improve overall plasma performance under operational conditions.

Campos, Nathan [Unlisted, US; Fermilab]↗

Features of explosion of thin aluminum foils on an 8 kA, 350 ns pulse generator

This paper presents the results of a study of the explosion of Al foils with a thickness of 4 μm on an 8 kA, 350 ns pulsed-power generator. The features of the energy deposition process in the explosion of foils in comparison with wires of similar mass and cross section, as well as with thin wires, are studied. In the experiments presented here, the dependence of the energy deposition in the foil on its initial structure was found. In conclusion, two types of exploded foil structure were recorded using point-projection radiography

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

Proton beam position measurement in air using a BPM

A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.

43 PARTICLE ACCELERATORS↗

Illumination-induced modulation of conductivity and Gunn oscillation properties in epitaxial GaAs

In this work, we illuminate a gallium arsenide (GaAs) Gunn device and study the light-induced changes of Gunn oscillation properties. We observe that illumination leads to the modulation of the Gunn threshold voltage, the Gunn oscillation magnitude, and the coherency of Gunn oscillation, with the nature of the modulation being closely related to the position of illumination on the device. These effects are attributed to the generation of optically excited carriers, which results in the modulation of conductivity and the electric field profile along the device. The finite element method is used to simulate the change of the field profile of the Gunn device caused by illumination. We also report an unexpected phenomenon of Gunn oscillation property manipulation with an optical chopper. In addition, wavelength-dependent, power-dependent, and pulsed illumination measurements are performed to help with further understanding the observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study of space charge induced non-linearity in the Single Line Of Sight camera

We report a new generation of gated x-ray detectors at the National Ignition Facility has brought faster, enhanced imaging capabilities. Their performance is currently limited by the amount of signal they can be operated with before space charge effects in their electron tube start to compromise their temporal and spatial response. We present a technique to characterize this phenomenon and apply it to a prototype of such systems, the Single Line Of Sight camera. Results of this characterization are used to benchmark Particle In Cell simulations of the electrons drifting inside the detector, which are found to well reproduce experimental data. These simulations are then employed to predict the optimum photon flux to the camera, with the goal to increase the quality of the images obtained on an experimental campaign while preventing the appearance of deleterious effects. They also offer some insight into some of the improvements that can be brought to the new pulse-dilation systems being built at Lawrence Livermore National Laboratory

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

Thermally Grown Oxide Stress in PS-PVD and EB-PVD Thermal Barrier Coatings Observed at Various Lifetimes Via Synchrotron X-ray Diffraction

The current standard application method for thermal barrier coatings (TBCs) on turbine blades for jet engines is electron-beam physical vapor deposition (EB-PVD) due to its high strain tolerance and low thermal conductivity. An emerging deposition method, plasma-spray physical vapor deposition (PS-PVD), presents an opportunity for a tailorable microstructure, and non-line-of-sight deposition that is faster and less expensive. To compare the lifetime behavior of both PS-PVD and EB-PVD coatings, samples subjected to 300 and 600 thermal cycles were measured during a 1 h thermal cycle to determine the strains, which were converted to stress, in the thermally grown oxide (TGO) layer of the TBCs using synchrotron X-ray diffraction (XRD). Room temperature XRD measurements indicated among samples that PS-PVD coatings experienced greater variation in in-plane room temperature strain in the TGO after cycling than the EB-PVD coatings. In-situ XRD measurements indicated similar high-temperature strain and no spallation after 600 thermal cycles for both coatings. Further, microscopy imaging after cycling showed greater rumpling in PS-PVD coatings that led to different failure modes between the two coatings’ TGO layers. The tailorability of PS-PVD coatings allows for adjustments in the processing parameters to improve their overall performance after aging and bridge the differences between the two deposition methods.

36 MATERIALS SCIENCE↗