Search NASA⌕ Search

SEARCH · Search NASA

Results for “outdoor deployment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

BETO 2021 Peer Review: Algae Biotechnology Partnership - Technology Area Session: Advanced Algae Systems

Development of advanced genetic and genomic tools for targeted algal metabolic engineering pursuits will be integral to achieving target biomass productivity and, ultimately, the BETO goal of cost-competitive biofuels derived from algal biomass by 2022. However, at present, broad-host-range tool development is currently hindered by strain-specific negative regulatory mechanisms. Indeed, the biological processes controlling algal transcription and translation are subject to complex host regulation, which often presents hurdles for targeted genetic engineering strategies. Advanced genetic approaches offer a means to rewire these regulatory systems and/or introduce novel functionality into algal biocatalysts. Synthetic systems biology approaches also present a means to construct novel genetic regulatory networks and rewire natural biological systems to establish an “orthogonal central dogma,” wherein non-native control elements are introduced into or evolved in host microbes for bypass of host control. To this end, the Algae Biotechnology Partnership aims to develop advanced genetic editing tools and synthetic and orthogonal genetic regulatory systems to enable universal metabolic engineering strategies in top-candidate deployment algal strains. Successful development will ultimately open the door for targeted strain-engineering strategies, aimed at maximizing algal outdoor biomass production, composition, and strain robustness.

biocatalysis↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PV Reference Cells for Outdoor Use: Comparison of First-Year Field Measurements

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as low-cost alternatives to thermopile pyranometers. But reference cell characteristics, such as directional and spectral response, fundamentally differ from pyranometers, and measurements made by the former cannot be substituted for or directly compared with the latter. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of multiple products from different manufacturers that are mounted at a fixed tilt, on a single-axis tracker, and on a dual-axis tracker. This report provides an analysis of the data collected during the first year of operation at the NREL location. An overall assessment is made by comparing the total energy measured by each instrument to the other instruments having the same orientation. These totals are calculated for three different scenarios: (1) using the factory calibration factors, (2) using the previously determined NREL Cell Lab calibration factors, and (3) using the newly determined field calibration factors derived from the recorded measurements. Because the true or correct measurement values are unknown, pair-wise comparisons are made. The results show that the difference between the highest and lowest measured energy can exceed 3% when using the factory calibration factors. Consistency among instruments improves when Cell Lab calibrations are used, and it further improves when using field calibration factors.

14 SOLAR ENERGY↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗

Emergent Degradation Phenomena Demonstrated on Resilient, Flexible, and Scalable Integrated Photoelectrochemical Cells

Photoelectrochemical (PEC) water splitting provides a pathway to generate sustainable clean fuels using the two most abundant resources on Earth: sunlight and water. Currently, most of the successful models of PEC cells are still fabricated on small scales near 1 cm 2 , which largely limits the mass deployment of solar-fuel production. Here, the scale-up to 8 cm 2 of an integrated PEC (IPEC) device is demonstrated and its performance compared to a 1 cm 2 IPEC cell, using state-of-the-art iridium and platinum catalysts with III–V photoabsorbers. The initial photocurrents at 1 sun are 8 and 7 mA cm -2 with degradation rates of 0.60 and 0.47 mA cm -2 day -1 , during unbiased operation for the 1 and 8 cm 2 devices, respectively. Additionally, evaluating under outdoor and indoor conditions at two U.S. National Laboratories reveals similar results, evidencing the reproducibility of this design's performance. Furthermore, the emerging degradation mechanisms during scale-up are investigated and the knowledge gained from this work will provide feedback to the broader community, since PEC device durability is a limiting factor in its potential future deployment.

25 ENERGY STORAGE↗

Water Splitting: Emergent Degradation Phenomena Demonstrated on Resilient, Flexible, and Scalable Integrated Photoelectrochemical Cells (Adv. Energy Mater. 48/2020)

We report Photoelectrochemical (PEC) water splitting provides a pathway to generate sustainable clean fuels using the two most abundant resources on Earth: sunlight and water. Currently, most of the successful models of PEC cells are still fabricated on small scales near 1 cm 2 , which largely limits the mass deployment of solar-fuel production. Here, the scale-up to 8 cm 2 of an integrated PEC (IPEC) device is demonstrated and its performance compared to a 1 cm 2 IPEC cell, using state-of-the-art iridium and platinum catalysts with III-V photoabsorbers. The initial photocurrents at 1 sun were 8 and 7 mA cm -2 with degradation rates of 0.60 and 0.47 mA cm -2 day -1 , during unbiased operation for the 1 and 8 cm 2 devices, respectively. Evaluating under outdoor and indoor conditions at two US National Laboratories revealed similar results, evidencing the reproducibility of this design’s performance. Furthermore, the emerging degradation mechanisms during scale-up are investigated and the knowledge gained from this work will provide feedback to the broader community, since PEC device durability is a limiting factor in its potential future deployment.

25 ENERGY STORAGE↗

Review of Potential–Induced Degradation in Bifacial Photovoltaic Modules

Bifacial modules are increasingly deployed in the field and are expected to represent half of the market share within 10 years. Their rear structure differs from monofacial modules to allow additional light absorption. However, it brings new reliability challenges to address. In particular, the risk of potential-induced degradation (PID) is increased as both module sides are impacted. Different PID processes have been identified in the literature: shunting type (PID-s), polarization type (PID-p), Na penetration type, and corrosion type (PID-c). Their occurrence depends on the photovoltaic system configuration as well as the module's materials. Apart from PID-s, PID processes are not well understood and extensive research is needed to elucidate the PID scenario and underlying mechanisms. Herein, current knowledge about PID processes and their impact on the main bifacial modules in the market are gathered with the aim to guide future research. Bifacial module technologies and leakage current paths leading to PID are described. Indoor and outdoor PID testing methods are detailed. For each bifacial module technology, the PID processes are investigated with their indicators, mechanism and recovery process. Furthermore, PID-impacting factors and limitation solutions are finally reported and a state of the art on PID modeling is presented.

14 SOLAR ENERGY↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Motivation, benefits, and challenges for new photovoltaic material & module developments

Abstract In the last decade and longer, photovoltaic module manufacturers have experienced a rapidly growing market along with a dramatic decrease in module prices. Such cost pressures have resulted in a drive to develop and implement new module designs, which either increase performance and/or lifetime of the modules or decrease the cost to produce them. In this paper, the main motivations and benefits but also challenges for material innovations will be discussed. Many of these innovations include the use of new and novel materials in place of more conventional materials or designs. As a result, modules are being produced and sold without a long-term understanding about the performance and reliability of these new materials. This has led to unexpected new failure mechanisms occurring few years after deployment, such as potential induced degradation or backsheet cracking. None of these failure modes have been detected after the back then common single stress tests. New accelerated test approaches are based on a combination or sequence of multiple stressors that better reflect outdoor conditions. That allows for identification of new degradation modes linked to new module materials or module designs.

Oreski, G. (ORCID:0000000342239047)↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Characterizing photovoltaic backsheet adhesion degradation using the wedge and single cantilever beam tests, Part I: Field Modules

Photovoltaic backsheets are exposed to harsh outdoor weathering conditions throughout their service lives that can compromise their protective function, through adhesive debonding between their constituent layers and between the backsheet and the module. We report a large-scale study on adhesive degradation was conducted on 37 field-exposed modules, that spanned 19 different module manufacturers, that were deployed among six Köppen–Geiger climatic zones, and that were fielded between 0 and 28 years. Six outer layer polymer classes were identified among the backsheets: polyamide (PA), polyethylene terephthalate (PET), polyvinyl fluoride (PVF), polyvinylidene fluoride (PVDF), fluoroethylene vinyl ether copolymer (FEVE), and tetrafluoroethylene hexafluoropropylene vinylidene fluoride copolymer (THV). Two adhesion tests were used to measure the adhesive strength: the wedge test and the width-tapered single-cantilever beam (SCB) test. Adhesion energies were compared across exposure time and Köppen–Geiger climatic zone. Many of the PET-, PVF-, and PVDF-based backsheets experienced degradation of the adhesive layer between the backsheet outer and core layers. A consistent trend of decreasing adhesion energy with exposure time was observed in five out of the six backsheet types. Trends among adhesion energy and climatic zone, while expected, were not observed, possibly due to broad ranges in temperature, humidity, and precipitation defining Köppen–Geiger climatic zones. The cantilever beam measurements produced an upper cutoff of approximately 100 J/m 2 , above which no modules exhibited field delamination. The results are part of a two-part study quantifying adhesion in both field-weathered and indoor-exposed PV backsheets.

14 SOLAR ENERGY↗

Nondestructive Characterization of Antireflective Coatings on PV Modules

Antireflective coatings (ARCs) are used on the vast majority of solar photovoltaic (PV) modules to increase power production. However, ARC longevity can vary from less than 1 to over 15 years depending on coating quality and deployment conditions. A technique that can quantify ARC degradation nondestructively on commercial modules would be useful both for in-field diagnostics and accelerated aging tests. In this article, we demonstrate that accurate measurements of ARC spectral reflectance can be performed using a modified commercially available integrating-sphere probe. The measurement is fast, accurate, nondestructive, and can be performed outdoors in full-sun conditions. We develop an interferometric model that estimates coating porosity, thickness, and fractional area coverage from the measured reflectance spectrum for a uniform single-layer coating. We demonstrate the measurement outdoors on an active PV installation, identify the presence of an ARC, and estimate the properties of the coating.

14 SOLAR ENERGY↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 3: Optical properties of black and brown carbon emissions

Residential biomass combustion is a source of carbonaceous aerosol. Inefficient combustion, particularly of solid fuels produces large quantities of black and brown carbon (BC and BrC). These particle types are important as they have noted effects on climate forcing and human health. One method of measuring these quantities is by measurement of aerosol light-absorption and scattering, which can be performed using an aethalometer and nephelometer, respectively. These instruments are widely deployed in the study of ambient air and are frequently used in air quality modeling and source apportionment studies. In this study, we will describe (1) a method for measuring primary BC and BrC emissions from two residential log-fired wood hydronic heaters and (2) the BC and BrC emission from these devices over a wide range of operating conditions, such as cold-starts, warm-starts, four different levels of output ranging from 15% to 100% maximum rated output, and periods of repeated cycling. The range in flue-gas BC concentrations, measured using an aethalometer at the 880 nanometer (nm) wavelength, were between 5.09 × 10 2 and 2.24 × 10 4 micrograms per cubic meter (µg/m 3 ) while the scattering coefficient of the flue-gas, measured by a nephelometer at 880 nm, ranged between 2.20 × 10 3 and 8.56 × 10 5 inverse megameters (Mm –1 ). The BrC concentrations, measured using the 370 nm wavelength of an aethalometer, were between 9.10 × 10 1 and 3.56 × 10 4 µg/m 3 . The calculated Angstrom Absorption Exponent (AAE) of the flue-gas aerosol ranged between 1.54 and 3.63. Performing a comparison between the measured BC concentration and an external particulate matter (PM) concentration showed that overall BC makes up roughly a quarter of the PM emitted by either of the two appliances. Further for both appliances, the cold-start and the test phase immediately following it had the highest BC and BrC concentrations, the highest measured scattering coefficient, as well as a low AAE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Office of Nuclear Verification FY 2023 Quarterly Report TSVT Q1

This project encompasses the continued development and training of a U.S. operational team, the Test Site Verification Team (TSVT), supporting verification of nuclear testing activities. TSVT builds on decades of U.S. nuclear testing history and nuclear explosion monitoring experience. The Team maintains readiness to deploy internationally on short notice to provide field-based support of verification of declared or undeclared nuclear testing and associated activities, as well as follow-on activities including monitoring and capability disablement and dismantlement, as established by negotiated agreement or treaty. The roles and structure of the TSVT are integrated with other NA-243 deployable verification teams and the interagency. FY23 TSVT activities focus on continued capability buildup within the team, including Team trainings and exercises with a focus on missions in confined spaces (e.g., tunnels, mines, other underground facilities), increased familiarity with foreign nuclear weapons testing programs, demonstration of Team capacity to deploy, train, and practice sustained OPSEC in non-western locations, establishment of sustainable storage and maintenance of equipment, specification and procurement of additional equipment to support field observations, further evolution of concepts of operation documents (CONOPs), and mission coordination with Headquarters and associated Stakeholders. Activities will culminate with a full-scale domestic team exercise at the end of FY23 focusing on underground activities signatures/observations and safety including advanced outdoor safety and familiarity in working around explosive test environments. In addition, we will be further articulating approaches and capacity relevant to the identification of nuclear tests, as well as monitoring of nuclear testing activities and/or dismantlement of nuclear test sites and anticipate developing additional equipment requests in support of this evolution. The TSVT Team Leads will also coordinate with its Senior Advisor, the TSVT Logistics and Readiness (L&R) Training Lead, and NNSA Headquarters to draft a five-year TSVT training and exercise plan, that strategically and incrementally builds capacity and expertise in key areas of significance for the continuum of nuclear and nuclear-related testing activities that fall within the team’s mission space.

42 ENGINEERING↗

GRUMDN: A Multi-Task Model for Predicting Human Patterns-of-Life from Stay Transition Data

Understanding human patterns-of-life (PoL) is essential towards ensuring safe and secure indoor facility environment as well as outdoor urban environment. Prediction of human movement in between places of interest is vital in understanding human PoL. Movement between spaces maybe represented and detected in one of the two forms: 1) trajectories: locations measured at regular time intervals by mobile sensors, bluetooth or GPS sensors; or 2) stay transitions: semantic PoI (points of interest) and stay duration data measurable by eventbased sensors that collect data when a check-in or check-out event is detected. Stay transition data provides a more compressed data format compared to trajectories data, especially in situations with longer stay durations, while preserving the information necessary for PoL analysis. Now as introduced briefly in the paper, our deployed end application (Digital Twin of a facility with non-player characters, besides the interactive user in virtual reality) needed a well-performing and validated AI/ML model for simulating high quality stay transitions behavior. In this study we thus primarily present our findings with developing and validating that model, which is a multi-task neural network for stay transition prediction. The neural network consists of two heads, for corresponding two tasks of stay category prediction and stay duration prediction. We evaluated gated recurrent units and multi-layer perceptrons of varying network sizes for stay category prediction; while mixture density networks, noisy generator-only networks, and generative adversarial networks of varying network sizes for stay duration prediction. We have then evaluated four multi-task models, constructed by combining these specialized models, on their ability to predict stay transition data. We tested our models on datasets from two different cases: 1) a simulation-generated dataset of indoor movement within the HFIR (high flux isotope reactor) nuclear reactor facility at Oak Ridge National Laboratory (ORNL); and 2) the GeoLife human mobility dataset of outdoor urban movement available in literature. Our results indicate that GRUMDN, which combines gated recurrent units (GRU) for stay category prediction task, and mixture density networks (MDN) for stay duration prediction task, did overall outperform other multitask models and the current state-of-the-art.

Gunaratne, Chathika [ORNL] (ORCID:0000000225088745↗

Long-lasting strong electrostatic attraction and adhesion forces of dust particles on photovoltaic modules

Photovoltaic (PV) energy-yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. The electrostatic attraction and adhesion force (F es ) of dust particles by the high voltages from solar panels have been reported to be 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, which has been corroborated by observing the increase in system voltage-induced soiling rate by setting up an outdoor test. Here, we report another characteristic of F es on soiling - long-lasting or slow decay after turning off the high voltage applied to solar panels. The F es decay time varies across a wide time range of 1 to 10 h, depending on two factors: 1) whether the cell, the particle, or both were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off - either connected through the power-supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting F es for hours can affect the solar panel soiling after sunset, and it can have an even greater effect when combined with water condensation at night.

14 SOLAR ENERGY↗

Effects of Media Nutrient Variation on Microalgae Productivity and Economics During Semi-Continuous Cultivation

The development of large-scale microalgae growth for biofuel production is currently limited by the cost of biomass production. However, new approaches to infrastructure and cultivation practices are bringing the field closer to realization. Macronutrients in the cultivation media contribute significant costs, especially since their concentrations have not been optimized for specific strains and conditions. Environmental photobioreactors (ePBRs) were used to simulate cultivation under outdoor conditions, during which the nitrogen and phosphorus levels in the media were varied. The growth of two potential biofuel production strains, Picochlorum celeri and Tetraselmis striata, with varying nutrient inputs during summer and winter scripts, respectively, was studied. This study demonstrated that nitrogen and phosphorus in f/2 media could be reduced by more than 60% from the standard formulation, while maintaining growth rates in a semi-continuous harvesting approach. Experiments comparing the standard and reduced nutrient input concentrations were also conducted for both species in 820 L outdoor raceway ponds, in Mesa, AZ. P. celeri grown in these ponds in October had a growth rate of 10.6 ± 0.7 g/m 2 /day and 10.6 ± 0.3 g/m 2 /day for the standard and low-nutrient P. celeri ponds, respectively. T. striata grown in April–May had a growth rate of 16.6 ± 1.4 g/m 2 /day for the standard nutrient input ponds and 17.4 ± 1.1 g/m 2 /day for the low-nutrient input ponds, and in October 14.5 ± 0.6 g/m 2 /day for standard nutrient ponds and 14.4 ± 0.6 g/m 2 /day for low-nutrient ponds. These outdoor data therefore confirmed the indoor ePBR data. Techno-economic analysis shows that, if high growth rates can be attained at lower nutrient concentrations, a reduction of at least 60% in nutrient costs can be achieved. Such results highlight the importance of managing macronutrient media inputs, as these have a considerable contribution to biomass production costs in large-scale facilities. The analysis also points to the importance of maintaining high spent medium recycling rates in an industrial deployment, so as to minimize the losses of nitrogen and phosphorus compounds.

09 BIOMASS FUELS↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗