Search NASA⌕ Search

SEARCH · Search NASA

Results for “overcharging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

44 records · Page 3

Advanced LiFSI-LiPF6 Electrolyte for Wide-Temperature and Thermally Stable Lithium-Ion Batteries

A new optimized LiFSI–LiPF6 dual-salt controlled-solvation electrolyte (E-DS) is demonstrated to enable practical graphite||LiNi0.8Mn0.1Co0.1O2 cells (˜4.0 mAh cm?²) to achieve exceptional performance and safety under extreme conditions. By optimizing anion coordination with the smaller, more dissociating FSI? anion, the E-DS forms ultrathin, dense, and inorganic-rich electrode/electrolyte interphases that dramatically suppress solvent decomposition, transition-metal dissolution, and surface reconstruction compared to the conventional LiPF6/carbonate electrolyte. Consequently, E-DS cells deliver >78% capacity retention after 300 cycles at 60 °C, retain fast discharging capacity at 30 °C, and operate effectively at -20 °C. Most strikingly, fully charged full cells with E-DS, even under overcharging to 4.8 V, show a lower heat evolution in stable formulations — transforming a traditionally unstable high-voltage/high-temperature configuration into an intrinsically safe state. This work establishes a new benchmark for carbonate-containing electrolytes, simultaneously achieving high energy density, fast-discharging capability, wide-temperature operation (-20 to 60 °C), and outstanding thermal safety in nickel-rich lithium-ion batteries.

electrode/electrolyte interphase↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics

With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics.

Nazaralizadeh, Solmaz (ORCID:0009000737004039)↗

Investigation of Fe-Ni Battery/Module for Grid Service Duty Cycles

Iron–nickel (Fe-Ni) batteries are renowned for their durability and resilience against overcharging and operating temperatures. However, they encounter challenges in achieving widespread adoption for energy storage applications due to their low efficiency and the need for regular maintenance and electrolyte replacement, which adds to maintenance costs. This study evaluates and demonstrates the capabilities of Fe-Ni batteries for participating in grid energy storage applications. Stable performance was observed frequency regulation (FR) testing at 100% and 50% state of charge (SOC)s, while at 50% SOC, there was a 14% increase in efficiency compared to 100% SOC. Although 25% SOC achieved higher efficiency, limited cyclability was observed due to reaching the discharge cutoff voltage. Optimal SOC selection, battery monitoring, maintenance, and appropriate charging strategies of Fe-Ni batteries seem to be crucial for their FR applications. Fe-Ni batteries exhibit stable peak shaving (PS) results, indicating their suitability and reliability under various load conditions for PS testing. Extended cycling tests confirm their potential for long-term grid-scale energy storage, enhancing their appeal for PS and FR applications.

25 ENERGY STORAGE↗

Interphase Engineering Enabled by Using a Separator with Electrochemically Active Carbazole Polymers for Lithium-Ion Batteries

Separators are generally considered inert components in lithium-ion batteries. In the past, some electroactive polymers have been successfully applied in separator modifications for overcharge protection or as acid scavengers. This study highlights the first use of two “electroactive” carbazole polymers (copolymer 9-phenyl-9H-carbazole-phenyl [PCP] and poly(9-vinylcarbazole) [PVC]), which were each applied separately as coatings on the cathode-facing side of commercial Celgard 2325 separators, respectively, to enhance the cycling performance of 0.3Li 2 MnO 3 ·0.7LiMn 0.5 Ni 0.5 O 2 //graphite (LMR-NM//Gr) full cells through interphase engineering. The team observed an irreversible polymer oxidation process of the carbazole-functionalized polymers—occurring only during the first charge—for the modified separator cells, and the results were confirmed by dQ/dV analysis, cyclic voltammetry measurements, and nuclear magnetic resonance characterizations. During this oxidation, carbazole polymers participate in the process of interphase formation, contributing to the improved cycling performance of LMR-NM//Gr batteries. Particularly, oxidation takes place at voltages of ~4.0 and ~3.5 V when PCP and PVC are used as separator coatings, which is highly irreversible. Further postmortem examinations suggest that the improvements using these modified separators arise from the formation of higher-quality and more inorganic SEI, as well as the beneficial CEI enriched in LixPOyFz. These interphases effectively inhibit the crosstalk effect by reducing TM dissolution.

carbazole↗

Anions Enhance Rare Earth Adsorption at Negatively Charged Surfaces

Anions are expected to be repelled from negatively charged surfaces. At aqueous interfaces, however, ion-specific effects can dominate over direct electrostatic interactions. Using multiple in situ surface sensitive experimental techniques, we show in this study that surface affinities of SCN – anions are so strong that they can adsorb at a negatively charged floating monolayer at the air–aqueous interface. This extreme example of ion-specific effects may be very important for understanding complex processes at aqueous interfaces, such as chemical separations of rare earth metals. Adsorbed SCN – ions at the floating monolayer increase the overall negative charge density, leading to enhanced trivalent rare earth adsorption. Surface sensitive X-ray fluorescence measurements show that the surface coverage of Lu 3+ ions can be triple the apparent surface charge of the floating monolayer in the presence of SCN – . Comparison to NO 3 – samples shows that the effects are strongly dependent on the character of the anion, providing further evidence of ion-specific effects dominating over electrostatics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗