Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygen activation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Interpreting Assemblages with Titanite (Sphene): It Does not have to be Greek to You.

Assemblages with titanite, pyroxene(s), olivine, ilmenite, magnetite, and quartz can be used to constrain the intensive and compositional variables that operate during crystallization. Such assemblages are relatively rare in metamorphic rocks, but they are more common in igneous rocks and more frequently reported in plutonic than volcanic rocks. We used the program QUILF, enhanced with thermodynamic data for titanite, to compute stable reactions among titanite (CaTiOSiO4), Fe-Mg-Ti ilmenite and magnetite (hereafter ilmenite and magnetite), Ca-Mg-Fe pyroxenes and olivine, and quartz, and to evaluate some of the factors that control titanite stability. Calculations at 1, 3, and 6 Kbar and 650, 850, 1100 0 C, in the system CaO - MgO - FeO Fe2O3 - TiO2 - SiO2, suggest that the reactions: Augitc + Ilmenite = Titanite + Magnetite + Quartz and Augite + Ilmenite + Quartz = Titanite + Orthopyroxene, impose well defined fugacity of O2, alpha(sub SiO2), , and compositional restrictions to the assemblages: (1) Titanite + Magnetite + Quartz, (2) Titanite + Orthopyroxene, (3) Augite + Ilmenite, and consequently titanite stability. From our calculations in this system we can draw the following general conclusions: (1) The assemblage Titanite + Magnetite + Quartz is always a good indicator of relatively high fugacity of O2, and it is likely more common in relatively iron-rich bulk compositions and for decreasing temperature and pressure conditions. (2) At high temperatures (>= 650 C) titanite is not stable in quartz-saturated rocks that contain the assemblage Orthopyroxene + Augite + Ilmenite + Magnetite. (3) In quartz-saturated rocks the coexistence of titanite and magnetite with either orthopyroxene or olivine requires a confluence of conditions relating bulk composition, fugacity of O2, and slow cooling. Thus, such assemblages must be rare. (4) Regardless of T and fugacity of O2 conditions, and bulk-composition, titanite is not stable in quartz-absent rocks that contain Olivine + Orthopyroxene + Augite + Ilmenite + Magnetite. Decreasing temperature and pressure conditions appear to favor titanite crystallization, thus, it is not unsurprising that titanite is frequently observed in slowly cooled rocks, albeit, in association with amphibole. We argue that the titanite + amphibole association is likely favored by high water activity, regardless of oxygen fugacity. Because water activity increases during crystallization of a pluton, the association titanite + amphibole, and consequently titanite, is likely to be more common in plutonic rocks than in volcanic rocks.

Xirouchakis, Dimitrios M.↗

Abundance ratios of oxygen, neon, and magnesium in solar active regions and flares: The FIP effect

Relative abundances of oxygen, neon, and magnesium have been derived for a sample of nine solar active regions, flares, and an erupting prominance by combining plots of the ion differential emission measures. The observations were photographed in the 300-600 A range by the Naval Research Laboratory (NRL) spectroheliograph on Skylab. Methods for deriving the Mg/Ne abundance ratio-which measures the separation between the low- first ionization potential (FIP) and high-FIP abundnace plateaus-have been described in previous papers. In this paper we describe the spectroscopic methods for deriving the O/Ne abundance ratio, which gives the ratio between two high-FIP elements. The plot of the O/Ne ratio versus the Mg/Ne ratio in the sample of nine Skylab events is shown. The variation in the Mg/Ne ratio by a factor of 6 is associated with a much smaller range in the O/Ne ratio. This is broadly consistent with the presence of the standard FIP pattern of abundances in the outer atmosphere of the Sun. However, a real change in the relative abundances of oxygen and neon by a factor of 1.5 cannot be excluded.

Widing, K. G.↗

Design of Refractory Metal Heat Pipe Life Test Environment Chamber, Cooling System, and Radio Frequency Heating System

A series of 16 Mo-44.5%Re alloy/sodium heat pipes will be experimentally tested to examine heat pipe aging. To support this evaluation, an environmental test chamber and a number of auxiliary subsystems are required. These subsystems include radio frequency (RF) power supplies/inductive coils, recirculation water coolant loops, and chamber gas conditioning. The heat pipes will be grouped, based on like power and gas mixture requirements, into three clusters of five units each, configured in a pentagonal arrangement. The highest powered heat pipe will be tested separately. Test chamber atmospheric purity is targeted at <0.3 ppb oxygen at an approximate operating pressure of 76 torr (.1.5 psia), maintained by active purification (oxygen level is comparable to a 10(exp -6) torr environment). Treated water will be used in two independent cooling circuits to remove .85 kW. One circuit will service the RF hardware while the other will maintain the heat pipe calorimetry. Initial procedures for the startup and operation of support systems have been identified. Each of these subsystems is outfitted with a variety of instrumentation, integrated with distributed real-time controllers and computers. A local area network provides communication between all devices. This data and control network continuously monitors the health of the test hardware, providing warning indicators followed by automatic shutdown should potentially damaging conditions develop. During hardware construction, a number of checkout tests.many making use of stainless steel prototype heat pipes that are already fabricated.will be required to verify operation.

Martin, J. J.↗

Removal of Biologically Active Organic Contaminants using Atomic Oxygen

Biomedical devices that are to come into contact with living tissue, such as prosthetic and other implants for the human body and the containers used to store and transport them, are together cleaned of non-living, but biologically active organic materials, including endotoxins such as lipopolysaccharides, and assembled into a hermetically sealed package without recontamination. This is achieved by cleaning both the device and package components together in an apparatus, which includes a hermetically sealed chamber, in which they are contacted with atomic oxygen which biocleans them, by oxidizing the biologically active organic materials. The apparatus also includes means for manipulating the device and container and hermetically sealing the cleaned device into the cleaned container to form the package. A calibrated witness coupon visually indicates whether or not the device and container have received enough exposure to the atomic oxygen to have removed the organic materials from their surfaces. Gamma radiation is then used to sterilize the device in the sealed container.

Bruce A Banks↗

Non-noble electrocatalysts for alkaline fuel cells

The doping of solid phase precursors followed by pyrolysis or the copyrolysis of gas phase precursors has allowed us to produce catalysts with good activity toward oxygen reduction. Efforts are currently underway to better understand the reasons for the catalytic activity of the bulk doped catalysts with a view toward further improving their activity.

Sarangapani, S.↗

A Survey of Large-Scale Variations in Thermospheric Oxygen Column Density with Magnetic Activity as Inferred from Observations of the FUV Dayglow

Brightness of the terrestrial far-ultraviolet (FUV) dayglow is dominated by the 130.4-nm emission of neutral atomic oxygen, OI, and variations in the brightness observed from altitudes high above the emitting region reflect variations in thermospheric oxygen density. This paper summarizes the results of an initial survey of the Dynamics Explorer 1 observations of the FUV dayglow through a presentation of 13 representative events selected to demonstrate the spatial extent and short-term temporal stability of the brightness perturbations. The emphasis here is on the morning sector of local time and the polar cap for observations obtained in the time interval from September 23, 1981, through January 19, 1982. An analytic expression is derived for the average response of the FUV photometer to the dayglow during periods of high-latitude magnetic quiescence. The remaining observations in this time interval are then analyzed for their deviations from the established quiet time values. Deviations of -40% to +30% are found following intervals of increased magnetic activity. The most significant decreases (-30% to -40%) are observed equatorward of the instantaneous aurora] oval only after sustained periods (approx. 6 hours) of intense magnetic activity (average AE greater than approx. 700 nT). Decreases extend equatorward from the aurora to geographic latitudes as low as approx. 30 deg N. Decreases of lesser magnitude that do not extend as far equatorward are associated with sustained periods of more moderate activity in which the average value of AE is smaller (approx. 300-400 nT). Also, the spatial extent and magnitude of the decreases in the morning sector appear greater when the IMF B(sub y) component is positive. In both cases, decreases are readily observed within the polar cap. Localized enhancements of +20% to +30% occur much less frequently and are detected at the middle latitudes, well equator-ward of the auroral oval.

Nicholas, A. C.↗

Oxidation of indole-3-acetic acid to oxindole-3-acetic acid by an enzyme preparation from Zea mays

Indole-3-acetic acid is oxidized to oxindole-3-acetic acid by Zea mays tissue extracts. Shoot, root, and endosperm tissues have enzyme activities of 1 to 10 picomoles per hour per milligram protein. The enzyme is heat labile, is soluble, and requires oxygen for activity. Cofactors of mixed function oxygenase, peroxidase, and intermolecular dioxygenase are not stimulatory to enzymic activity. A heat-stable, detergent-extractable component from corn enhances enzyme activity 6- to 10-fold. This is the first demonstration of the in vitro enzymic oxidation of indole-3-acetic acid to oxindole-3-acetic acid in higher plants.

NASA Discipline Number 40-10↗

Hydrogen Reduction of Ilmenite from Lunar Regolith

Each ascent vehicle returning from the lunar surface with a crew vehicle will require several tons of fuel. Most architecture studies of lunar exploration vehicles use liquid oxygen for fuel, either for LOX/LH2 or LOX/methane. Utilization of oxygen generated on the lunar surface saves mass launched from Earth, with a multiplication factor on the order of 4-5, e.g. production and utilization of 4 tons of lunar oxygen for the ascent vehicle saves 16-20 tons of initial mass in low Earth orbit (IMLEO). The paper discusses ongoing MSFC activity on oxygen production by hydrogen reduction of Ilmenite. Specifically the important project milestone is to develop the Technology Readiness Level for the generation of lunar oxygen for propellant production from 3 to 5. The paper will provide an overview of the processes for Oxygen Generation, Complete Systems Architecture for a pilot lunar plant, experimental apparatus development and initial experimental results, and future directions.

Ramachandran, N.↗

High temperature sorbents for oxygen

A sorbent capable of removing trace amounts of oxygen (ppt) from a gas stream at a high temperature above 200 C comprising a porous alumina silicate support, such as zeolite, containing from 1 to 10 percent by weight of ion exchanged transition metal, such as copper or cobalt ions, and 0.05 to 1.0 percent by weight of an activator selected from a platinum group metal such as platinum is described. The activation temperature, oxygen sorption, and reducibility are all improved by the presence of the platinum activator.

Sharma, Pramod K.↗

High Temperature Sorbents for Oxygen

A sorbent capable of removing trace amounts of oxygen (ppt) from a gas stream at a high temperature above 200 C is introduced. The sorbent comprises a porous alumina silicate support such as zeolite containing from 1 to 10 percent by weight of ion exchanged transition metal such as copper or cobalt ions and 0.05 to 1.0 percent by weight of an activator selected from a platinum group metal such as platinum. The activation temperature, oxygen sorption and reducibility are all improved by the presence of the platinum activator.

Sharma, Pramod K.↗

Microdistribution of oxygen in silicon

The microdistribution of oxygen in Czochralskii-grown, p-type silicon crystals was determined by using the SEM in the EBIC mode in conjunction with spreading resistance measurements. When the conductivity remained p-type, bands of contrast were observed in the EBIC image which corresponded to maxima in resistivity. When at the oxygen concentration maxima the oxygen donor concentration exceeded the p-type dopant concentration, an inversion of the conductivity occurred. It resulted in the formation of p-n junctions in a striated configuration and the local inversion of the EBIC image contrast. By heat-treating silicon at 1000 C prior to the activation of oxygen donors, some silicon-oxygen micro-precipitates were observed in the EBIC image within the striated oxygen concentration maxima.

Murgai, A.↗

Combustion Stability Analyses of Coaxial Element Injectors with Liquid Oxygen/Liquid Methane Propellants

Liquid rocket engines using oxygen and methane propellants are being considered by the National Aeronautics and Space Administration (NASA) for in-space vehicles. This propellant combination has not been previously used in a flight-qualified engine system, so limited test data and analysis results are available at this stage of early development. NASA has funded several hardware-oriented activities with oxygen and methane propellants over the past several years with the Propulsion and Cryogenic Advanced Development (PCAD) project, under the Exploration Technology Development Program. As part of this effort, the NASA Marshall Space Flight Center has conducted combustion stability analyses of several of the configurations. This paper presents test data and analyses of combustion stability from the recent PCAD-funded test programs at the NASA MSFC. These test programs used swirl coaxial element injectors with liquid oxygen and liquid methane propellants. Oxygen was injected conventionally in the center of the coaxial element, and swirl was provided by tangential entry slots. Injectors with 28-element and 40-element patterns were tested with several configurations of combustion chambers, including ablative and calorimeter spool sections, and several configurations of fuel injection design. Low frequency combustion instability (chug) occurred with both injectors, and high-frequency combustion instability occurred at the first tangential (1T) transverse mode with the 40-element injector. In most tests, a transition between high-amplitude chug with gaseous methane flow and low-amplitude chug with liquid methane flow was readily observed. Chug analyses of both conditions were conducted using techniques from Wenzel and Szuch and from the Rocket Combustor Interactive Design and Analysis (ROCCID) code. The 1T mode instability occurred in several tests and was apparent by high-frequency pressure measurements as well as dramatic increases in calorimeter-measured heat flux throughout the chamber. Analyses of the transverse mode were conducted with ROCCID and empirical methods such as Hewitt d/V. This paper describes the test hardware configurations, test data, analysis methods, and presents results of the various analyses.

Hulka, J. R.↗

Combustion and Performance Analyses of Coaxial Element Injectors with Liquid Oxygen/Liquid Methane Propellants

Liquid rocket engines using oxygen and methane propellants are being considered by the National Aeronautics and Space Administration (NASA) for in-space vehicles. This propellant combination has not been previously used in a flight-qualified engine system, so limited test data and analysis results are available at this stage of early development. NASA has funded several hardware-oriented activities with oxygen and methane propellants over the past several years with the Propulsion and Cryogenic Advanced Development (PCAD) project, under the Exploration Technology Development Program. As part of this effort, the NASA Marshall Space Flight Center has conducted combustion, performance, and combustion stability analyses of several of the configurations. This paper summarizes the analyses of combustion and performance as a follow-up to a paper published in the 2008 JANNAF/LPS meeting. Combustion stability analyses are presented in a separate paper. The current paper includes test and analysis results of coaxial element injectors using liquid oxygen and liquid methane or gaseous methane propellants. Several thrust chamber configurations have been modeled, including thrust chambers with multi-element swirl coax element injectors tested at the NASA MSFC, and a uni-element chamber with shear and swirl coax injectors tested at The Pennsylvania State University. Configurations were modeled with two one-dimensional liquid rocket combustion analysis codes, the Rocket Combustor Interaction Design and Analysis (ROCCID), and the Coaxial Injector Combustion Model (CICM). Significant effort was applied to show how these codes can be used to model combustion and performance with oxygen/methane propellants a priori, and what anchoring or calibrating features need to be applied or developed in the future. This paper describes the test hardware configurations, presents the results of all the analyses, and compares the results from the two analytical methods

Hulka, J. R.↗

Space Radiation Induces Long Term Impact on the Cardiovascular System by the Activation of FYN Through Reactive Oxygen Species

Space radiation can damage the cardiovascular system and thus is an important health risk factor for astronauts during long-term space missions. We utilized publicly available transcriptomic data through NASA's GeneLab platform (genelab.nasa.gov) to determine cardiovascular system response to space radiation. GeneLab is an open repository that houses all NASA related omics experiments including on the International Space Station (ISS) and related radiation ground studies. We analyzed 3 datasets from GeneLab: GLDS-117 and GLDS-109, which are ground studies of cardiomyocytes followed-up for 28 days after exposure to 90cGy of proton at 1GeV and 15cGy of 56Fe at 1GeV; and GLDS-52, human endothelial cells (HUVECs) that were cultured for 10 days on the ISS. The ground studies were designed to characterize the long-term impact following space irradiation on cardiomyocytes for 5 different time points up to 28 days after irradiation. Our analysis was guided by the hypothesis that there are common persistent molecules affecting the cardiovascular system due to radiation effects during spaceflight. Endothelial cells are known to directly regulate the development and activity of cardiomyocytes, and thus their response to spaceflight should be highly correlated with cardiomyocytes. To investigate our hypothesis, we identified the molecular pathways that were modified for all time points compared across both radiation on the ground and the pathways found in HUVECs flown in the ISS. We found the following key results related to the cardiovascular systems: 1) space radiation downregulate ROS functions; and 2) the key/driving genes: FYN, LCK, AKT1 are upregulated and LYN and FOS are downregulated with FYN being the central driver/hub for the cardiovascular response to space radiation. It is worth noting the activation of FYN is a key event which prevents cardiac cell death and ROS production. From our study we thus hypothesize that a feedback loop occurs from the oxidative stress caused by space radiation that upregulates FYN which in turn reduces ROS levels and thus ROS pathways, preventing cardiomyocyte and endothelial cell death and thus protecting the cardiovascular systems. We believe that this is a novel mechanism for space radiation induced cardiovascular risk directly linking radiation ground studies to spaceflight

Beheshti, Afshin↗