Cerebral vasoconstriction precedes orthostatic intolerance after parabolic flight

The effects of brief but repeated bouts of micro- and hypergravity on cerebrovascular responses to head-up tilt (HUT) were examined in 13 individuals after (compared to before) parabolic flight. Middle cerebral artery mean flow velocity (MCA MFV; transcranial Doppler ultrasound), eye level blood pressure (BP) and end tidal CO(2) (P(ET)CO(2)) were measured while supine and during 80 degrees HUT for 30 min or until presyncope. In the postflight tests subjects were classified as being orthostatically tolerant (OT) (n = 7) or intolerant (OI) (n = 6). BP was diminished with HUT in the OT group in both tests (p < 0.05) whereas postflight BP was not different from supine in the OI group. Postflight compared to preflight, the reduction in P(ET)CO(2) with HUT (p < 0.05) increased in both groups, although significantly so only in the OI group (p < 0.05). The OI group also had a significant decrease in supine MCA MFV postflight (p < 0.05) that was unaccompanied by a change in supine P(ET)CO(2). The decrease in MCA MFV that occurred during HUT in both groups preflight (p < 0.05) was accentuated only in the OI group postflight, particularly during the final 30 s of HUT (p < 0.05). However, this accentuated decrease in MCA MFV was not correlated to the greater decrease in P(ET)CO(2) during the same period (R = 0.20, p = 0.42). Although cerebral vascular resistance (CVR) also increased in the OI group during the last 30 s of HUT postflight (p < 0.05), the dynamic autoregulatory gain was not simultaneously changed. Therefore, we conclude that in the OI individuals, parabolic flight was associated with cerebral hypoperfusion following a paradoxical augmentation of CVR by a mechanism that was not related to changes in autoregulation nor strictly to changes in P(ET)CO(2).

Parabolic Flight↗

Parabolic flight reveals independent binocular control of otolith-induced eye torsion

To examine otolith-governed ocular torsion in hyper- and hypogravity, eight subjects, including two astronauts, underwent parabolic flight while seated upright with head fixed. A mask fitted with two video cameras provided synchronized images of both eyes at a rate of 25/sec during 15 parabolas, the individual parabolas separated by a few minutes of level 1 G flight. Three main findings emerged: 1) After the first parabola, most subjects showed differential torsional offset of the two eyes in the 1 G portions between parabolas, compared to the conjugate baseline position of the eyes prior to the first parabola. 2) Changes in binocular torsion in the 0 G and 1.8 G portions of parabolic flight revealed in most subjects systematic reversal of direction. The reversal was consistent within, but not across subjects. 3) Disconjugacy defined as the moment-to-moment difference in the movements of the two eyes, and evaluated without the contribution of the differential offset, found two subjects with relatively high disconjugacy scores, and the remaining six with low scores. On the basis of prior studies (9, 20), we would predict the first two would be subject to SMS, the remainder not. The two astronauts, who did not have SMS on their space missions, fell into the low scoring group. We propose that the disconjugacies may be due to intrinsic asymmetries in the otolith receptors on the two sides of the head, which appear to be independently linked to the extraocular muscles of the two eyes, a phenomenon masked in normal 1 G states by adaptation. The apparently independent control of the two sides cannot be detected by the simpler and more common monocular studies.

Non-NASA Center↗

Similarity and generalized finite-difference solutions of parabolic partial differential equations.

Techniques are presented for obtaining generalized finite-difference solutions to partial differential equations of the parabolic type. It is shown that the advantages of similarity in the solution of similar problems are generally not lost if the solution to the original partial differential equations is effected in the physical plane by finite-difference methods. The analysis results in a considerable saving in computational effort in the solution of both similar and nonsimilar problems. Several examples, including both the heat-conduction equation and the boundary-layer equations, are given. The analysis also provides a practical means of estimating the accuracy of finite-difference solutions to parabolic equations.

Clausing, A. M.↗

Responses of blind fish to gravitational changes as achieved in parabolic flight

Blind fish, during parabolic flight, display a measurable and consistent behavior. The most spectacular new behavioral response is the forward looping of blind fish in or near weightlessness. This response shows no measurable adaptation during the entire period of weightlessness of about 30 sec. During the entrance and exit of weightless parabolas (pushover and pullout) respectively, the fish assumes a forward tilted diving position. Parabolic flight with negative g in the range between 0g and -1g causes similar diving responses of the fish with the only difference being that the dive is directed toward the top of the fish tank. When the response to a g value less than 1g is compared to the response to increased g load on the ground (escape of darting response) an essential difference is seen: higher horizontal acceleration or jerk on the ground causes fish to swim, or even dart, against the direction of inertial force; fish during weightless parabolas move into the direction of the inertial or gravitational force. Since the vestibular system of fish is homologous to that of man, the observed behavior of fish in weightless flight could help to better understand human performance and sensations in comparable situations.

Vonbaumgarten, R. J.↗

Parabolic cylinder antennas

Some of the features of single and dual parabolic-cylinder reflector antenna systems are discussed in terms of wave conversions, field divergence, and wavefronts in Fresnel and Fraunhofer regions. Beam-squinting, by mechanical displacement and electrical phase gradient methods, is introduced together with the combination of these methods. In the case of dual parabolic cylinders there is also a discussion of surface-truncation, parametric representation of surface intersections, main-aperture blockage by the subsystem, and beam squinting. A few diffraction patterns are presented to illustrate the type of data available via a formulation equivalent to the complex-vector Kirchhoff-Kottler formulation. Main and cross-polarization components of the solution are available as they are inherently part of the field solution in the Cartesian coordinate system. A means of displaying main and cross-polarization components for arbitrary beam-scanning in space is outlined. Extensions to monopulse tracking with variable-beamwidth (zooming) capability are introduced.

Schmidt, R. F.↗

The parabolic approximation for sound propagation in a stratified moving medium

Propagation of sound in a stratified moving medium is discussed through an extension of the parabolic approximation to the acoustic equations of motion for short wavelengths. The parabolic approximation is related to the theory of geometric acoustics, and it is shown that it yields an improvement in accuracy over geometric theory. Also, the approximation corrects cumulative failures of geometric theory which occur when sound propagates many wavelengths from its source. The theory is illustrated by application to simple examples of quasi-plane wave propagation.

Myers, M. K.↗

Evaluation of the three-dimensional parabolic flow computer program SHIP

The three-dimensional parabolic flow program SHIP designed for predicting supersonic combustor flow fields is evaluated to determine its capabilities. The mathematical foundation and numerical procedure are reviewed; simplifications are pointed out and commented upon. The program is then evaluated numerically by applying it to several subsonic and supersonic, turbulent, reacting and nonreacting flow problems. Computational results are compared with available experimental or other analytical data. Good agreements are obtained when the simplifications on which the program is based are justified. Limitations of the program and the needs for improvement and extension are pointed out. The present three dimensional parabolic flow program appears to be potentially useful for the development of supersonic combustors.

Pan, Y. S.↗

Plane waves at or near grazing incidence in the parabolic approximation

The parabolic approximation for the acoustic equations of motion is applied to the study of the sound field generated by a plane wave at or near grazing incidence to a finite impedance boundary. It is shown how this approximation accounts for effects neglected in the usual plane wave reflection analysis which, at grazing incidence, erroneously predicts complete cancellation of the incident field by the reflected field. Examples are presented which illustrate that the solution obtained by the parabolic approximation contains several of the physical phenomena known to occur in wave propagation near an absorbing boundary.

Mcaninch, G. L.↗

Cost/performance of solar reflective surfaces for parabolic dish concentrators

Materials for highly reflective surfaces for use in parabolic dish solar concentrators are discussed. Some important factors concerning performance of the mirrors are summarized, and typical costs are treated briefly. Capital investment cost/performance ratios for various materials are computed specifically for the double curvature parabolic concentrators using a mathematical model. The results are given in terms of initial investment cost for reflective surfaces per thermal kilowatt delivered to the receiver cavity for various operating temperatures from 400 to 1400 C. Although second surface glass mirrors are emphasized, first surface, chemically brightened and anodized aluminum surfaces as well as second surface, metallized polymeric films are treated. Conventional glass mirrors have the lowest cost/performance ratios, followed closely by aluminum reflectors. Ranges in the data due to uncertainties in cost and mirror reflectance factors are given.

Bouquet, F.↗

Thermal storage requirements for parabolic dish solar power plants

The cost effectiveness of a high temperature thermal storage system is investigated for a representative parabolic dish solar power plant. The plant supplies electrical power in accordance with a specific, seasonally varying demand profile. The solar power received by the plant is supplemented by power from fuel combustion. The cost of electricity generated by the solar power plant is calculated, using the cost of mass-producible subsystems (specifically, parabolic dishes, receivers, and power conversion units) now being designed for this type of solar plant. The trade-off between fuel and thermal storage is derived in terms of storage effectiveness, the cost of storage devices, and the cost of fuel. Thermal storage requirements, such as storage capacity, storage effectiveness, and storage cost are established based on the cost of fuel and the overall objective of minimizing the cost of the electricity produced by the system. As the cost of fuel increases at a rate faster than general inflation, thermal storage systems in the $40 to $70/kWthr range could become cost effective in the near future.

Wen, L.↗

Parabolic dish collectors - A solar option

A description is given of several parabolic-dish high temperature solar thermal systems currently undergoing performance trials. A single parabolic dish has the potential for generating 20 to 30 kW of electricity with fluid temperatures from 300 to 1650 C. Each dish is a complete power-producing unit, and may function either independently or as part of a group of linked modules. The two dish designs under consideration are of 11 and 12 meter diameters, yielding receiver operating temperatures of 925 and 815 C, respectively. The receiver designs described include (1) an organic working fluid (toluene) Rankine cycle engine; (2) a Brayton open cycle unit incorporating a hybrid combustion chamber and nozzle and a shaft-coupled permanent magnet alternator; and (3) a modified Stirling cycle device originally designed for automotive use. Also considered are thermal buffer energy storage and thermochemical transport and storage.

Truscello, V. C.↗

Parabolic dish systems at work - Applying the concepts

An overview is given of parabolic dish solar concentrator application experiments being conducted by the U.S. Department of Energy. The 'engineering experiments' comprise the testing of (1) a small-community powerplant system, in conjunction with a grid-connected utility; (2) stand-alone applications at remote sites such as military installations, radar stations and villages; and (3) dish modules that can deliver heat for direct use in industrial processes. Applicability projections are based on a dish and receiver that use a Brayton engine with an engine/generator efficiency of 25% and a production level of up to 25,000 units per year. Analyses indicate that parabolic-dish power systems can potentially replace small, oil-fired power plants in all regions of the U.S. between 1985 and 1991.

Marriott, A. T.↗

Irrigation market for solar thermal parabolic dish systems

The potential size of the onfarm-pumped irrigation market for solar thermal parabolic dish systems in seven high-insolation states is estimated. The study is restricted to the displacement of three specific fuels: gasoline, diesel and natural gas. The model was developed to estimate the optimal number of parabolic dish modules per farm based on the minimum cost mix of conventional and solar thermal energy required to meet irrigation needs. The study concludes that the potential market size for onfarm-pumped irrigation applications ranges from 101,000 modules when a 14 percent real discount rate is assumed to 220,000 modules when the real discount rate drops to 8 percent. Arizona, Kansas, Nebraska, New Mexico and Texas account for 98 percent of the total demand for this application, with the natural gas replacement market accounting for the largest segment (71 percent) of the total market.

Habib-Agahi, H.↗

Secondary concentrators for parabolic dish solar thermal power systems

A variety of different concepts are currently being studied with the objective to lower the cost of parabolic mirrors and to provide alternatives. One of the considered approaches involves the use of compound concentrators. A compound solar concentrator is a concentrator in which the sunlight is reflected or refracted more than once. It consists of a primary mirror or lens, whose aperture determines the amount of sunlight gathered, and a smaller secondary mirror or lens. Additional small optical elements may also be incorporated. The possibilities and problems regarding a use of compound concentrators in parabolic dish systems are discussed. Attention is given to concentrating secondary lenses, secondary imaging and concentrating mirrors, conical secondary mirrors, compound elliptic secondary concentrating mirrors, and hyperbolic trumpet secondary concentrating mirrors.

Jaffe, L. D.↗

Development, solar test, and evaluation of a high-temperature air receiver for point-focusing parabolic dish applications

A high temperature solar receiver was fabricated and tested in excess of 1370 C on an 11-meter-diameter test bed concentrator at the Jet Propulsion Laboratory Parabolic Dish Test Site, Edwards, California. The 60-kilowatt thermal receiver design utilizes state-of-the-art silicon carbide honeycomb matrix panels to receive and transfer the solar energy and mullite elements for thermal buffer storage. Solar tests were conducted with indicated air exit temperatures ranging from 885 C (1625 F) to 1427 C (2600 F), mass flow rates of 75 to 105 g/sec (0.16 to 0.23 lbm/sec), and pressures up to 265 kPa absolute (38.4 psia). Estimates of efficiency are 59.7% at 1120 C (2048 F) to 80.6% at 885 C (1625 F) when aperture spillage losses are considered separately. Results are presented which demonstrate the feasibility of this innovative receiver concept for point-focusing parabolic dish applications over a wide temperature range.

Hanseth, E. J.↗

Configuration selection study for isolated loads using parabolic dish modules

A configuration tradeoff study has been conducted to determine optimum solar thermal parabolic dish power systems for isolated load applications. The specific application of an essentially constant power demand as required for MX missile shelters is treated. Supplying a continuous level of power with high reliability is shown to require a power system comprising modular parabolic dish power units where the heat engines of the modular power units can be driven by fossil fuels as well as solar-derived heat. Since constraints on reliability result in the provision of a power generating capability that exceeds the constant demand level, efficient utilization of the power system requires battery storage. Tradeoffs regarding the optimum size of storage are investigated as a function of the number of power modules and the cost of the fossil fuel which is used to meet the demand when insolation is unavailable and storage is depleted.

Revere, W.↗

Configuration selection study for isolated loads using parabolic dish modules

A configuration tradeoff study was conducted to determine optimum solar thermal parabolic dish power systems for isolated load applications. The specific application of an essentially constant power demand as required for MX missile shelters is treated. Supplying a continuous level of power with high reliability is shown to require a power system comprising modular parabolic dish power units where the heat engines of the modular power units can be driven by fossil fuels as well as solar-derived heat. Since constraints on reliability result in the provision of a power generating capability that exceeds the constant demand level, efficient utilization of the power system requires battery storage. Tradeoffs regarding the optimum size of storage are investigated as a function of the number of power modules and the cost of the fossil fuel.

Revere, W.↗

Incompressible Navier-Stokes and parabolized Navier-Stokes solution procedures and computational techniques

Recent developments with finite-difference techniques are emphasized. The quotation marks reflect the fact that any finite discretization procedure can be included in this category. Many so-called finite element collocation and galerkin methods can be reproduced by appropriate forms of the differential equations and discretization formulas. Many of the difficulties encountered in early Navier-Stokes calculations were inherent not only in the choice of the different equations (accuracy), but also in the method of solution or choice of algorithm (convergence and stability, in the manner in which the dependent variables or discretized equations are related (coupling), in the manner that boundary conditions are applied, in the manner that the coordinate mesh is specified (grid generation), and finally, in recognizing that for many high Reynolds number flows not all contributions to the Navier-Stokes equations are necessarily of equal importance (parabolization, preferred direction, pressure interaction, asymptotic and mathematical character). It is these elements that are reviewed. Several Navier-Stokes and parabolized Navier-Stokes formulations are also presented.