Search NASA⌕ Search

SEARCH · Search NASA

Results for “parabolic trough power plant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

Wind-induced torsion of parabolic trough collectors in operation

Parabolic trough collector (PTC) systems, a type of concentrating solar power (CSP), use parabolic mirrors to reflect the sun's rays toward an absorber tube to heat the fluid inside. PTCs track the sun throughout the day and are sensitive to angular misalignment, which reduces optical performance. Torsion of the PTC, exacerbated by wind loading, contributes to angular misalignment, which has been quantified by previous studies using numerical simulations and experimental tests. However, angular misalignment due to torsion and wind loading has not yet been studied in an operational plant, which can experience more extreme and variable conditions. This study characterizes the angular misalignment due to torsion at three rows of the Nevada Solar One CSP plant and investigates the influence of wind loading. These findings reveal substantial torsion along the PTC support structure that depends on wind conditions and orientation. Strong winds perpendicular to the PTCs increase the median angular displacement of the outermost row by up to 18 mrad and increase the standard deviation by up to 8 mrad when compared to weak wind conditions. These findings can inform enhanced PTC design, controls and modeling that will improve the performance, reliability and bankability of future CSP plants.

14 SOLAR ENERGY↗

Development and testing of a solar flux heating freeze recovery system for molten salt parabolic troughs

A major obstacle preventing commercialization of molten salt parabolic trough plants is freeze protection and recovery of the solar field. One of the most common nitrate salt compositions under consideration allows for solar field outlet temperatures up to 565°C and begins solidifying above 240°C. Using molten salt directly in the solar field can significantly reduce thermal energy storage costs and the higher temperature compared to oil heat transfer fluids can power a more efficient power cycle, but the very high freezing point is cause for concern. This work builds on a previous modeling effort investigating different methods for melting Solar Salt frozen in the solar field, which suggested the viability of a novel solar heating method to lower costs of the freeze protection system. In this work higher fidelity models are developed to better investigate the melting process with a more detailed 3D geometry which includes the insulated bellows. The thermal-fluid model of the melting process is updated to include temperature dependent density and data for solid phase properties. In addition, a finite element model is developed to resolve thermal stresses at the point with highest thermal gradients. Results with the new model confirm the viability of using controllable solar flux heating to thaw salt frozen in the solar field without damaging the receiver; however, the presence of non-illuminated sections significantly slows down the melting process. Solar heating simulations with pauses off-sun of 120 and 60 s require 18.5 and 11.9 h to melt salt from a night-time temperature of 10°C with 1000 W m2 DNI, which results in maximum thermal stresses of 48.2 and 53.5 MPa, respectively. Adding 150 W m−1 to the solar heating simulation with a 60 s pause off-sun decreases both the melt time and thermal stresses due to the more uniform heating, suggesting a combined heating method may be the best option.

14 SOLAR ENERGY↗

Wind Conditions for Solar Energy Facility Design Based on Field Measurements at Nevada Solar One

This study characterises near-surface wind conditions at the Nevada Solar One (NSO) concentrated solar power plant using two years of measurements from a 15-m mast located 30 m west of the solar arrays. The surrounding terrain is fairly flat within 3 km, but nearby solar photovoltaic (PV) and concentrated solar power (CSP) installations introduce strong directional wind inhomogeneity, which motivates a sector-based analysis that distinguishes undisturbed inflow from waked flow. The analysis uses data from three sonic anemometers to assess whether turbulence in the surface layer can be represented as Gaussian and whether standard surface-layer scaling remains valid below 10 m height. The roughness length and displacement height are estimated for twelve directional sectors under near-neutral wind conditions, and all three velocity components show departures from Gaussian behaviour. Spectral analysis indicates that the turbulence contains low-frequency fluctuations with amplitudes higher than those predicted by standard models such as the Kaimal model or the Simiu and Scanlan model. The study introduces a new turbulence spectral model based on the eddy-surface-layer framework to better represent near-surface wind turbulence. The analysis further quantifies the influence of the surrounding power plants on mean wind profiles, one-point spectra, and vertical coherence for all velocity components. The solar collector arrays located 30 m east of the mast significantly modify the turbulence structure, whereas PV installations situated a few hundred metres away have only a limited influence on the turbulence measured at the mast. These findings highlight the limitations of conventional turbulence models for near-surface wind over solar infrastructure and provide improved parameterisations to support the structural design. The implications for the structural response of parabolic troughs and PV modules to such turbulence remain uncertain and require further investigation.

14 SOLAR ENERGY↗

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Thermodynamically Stable, Plasmonic Transition Metal Oxide Nanoparticle Solar Selective Absorbers towards 95% Optical-to-Thermal Conversion Efficiency at 750 °C

Generation 3 (Gen) concentrating solar power (CSP) systems requires a high operation temperature ≥750°C to increase the power-cycle efficiency towards ≥50%. However, such a high operation temperature poses a notable challenge to high temperature materials. On the receiver side, a critical challenge is the lack of solar selective absorbers that demonstrate both high optical-to-thermal energy conversion efficiency η therm approaching 95% and long-term thermal stability at >750°C in air. Existing solar absorbers either have limited η therm ≤89% or deteriorate significantly within 500 h at 750°C; some of these also require costly vacuum deposition for stringent thickness control. Therefore, it is highly desirable to simultaneously achieve η therm ~95% AND high thermal stability at 750°C for future generations of CSP receivers. This project has investigated and developed low-cost, highly scalable spray-coated transition metal oxide nanoparticle (NP) pigmented solar selective coatings on various types of Inconel alloy tube sections that are thermodynamically stable at 750-800°C in air, maintaining η therm >94.3%(93.2%) under a solar concentration ratio of C=1000 after 60 simulated day-night cycles at 750ºC (800ºC) (1 cycle=12 h at 750 or 800°C and 12h ramping down to 25°C). We have also coated up to 48 inches long receiver tubes for preliminary solar testing under Norwich Technology’s parabolic trough systems, demonstrating notably improved performance in solar heating compared to benchmark Pyromark 2500 coatings. Two key innovations have been developed in this project: (1) We achieved an unprecedented high thermal efficiency >94% by optimizing the d-band optical absorption spectra of transition metal ions, engineering their valences and stoichiometry; (2) We were able to maintain or even slightly increase the efficiency when operating at 750°C in air by engineering the interdiffusion of transition metal ions between the coating and the Inconel substrate to our advantage. Featuring high-temperature solar spectral selectivity and thermodynamic stability in air, as well as low-cost, highly scalable solution-chemical synthesis and spray coating techniques, this innovation in solar selective absorber technology alone accounts for nearly 40% of the targeted reduction in the levelized cost of electricity (LCOE) from the receiver, thermal energy storage, and operation & maintenance combined by 2030, as proposed by the U.S. Department of Energy. For a 110 MWe CSP power plant, this LCOE reduction from the solar selective coating alone transfers to ~$\$ $1.9 M increase in annual profit based on a sales price of 10¢/kWh (or an annual sale of $50 M/year). The high solar absorptance (~98%) NP pigment materials developed in this project are equally applicable to volumetric receivers either as a coating or as bigger ceramic microspheres after sintering, potentially benefiting Gen3 falling particle CSP technologies. All these contributions facilitate the larger scale deployment of CSP systems with energy storage capability to address the intermittency issue of solar energy towards dispatchable solar electricity, bridging the temporal gap between peak solar electricity production and peak electricity consumption. The collaboration with Norwich Technologies and Brayton Energy in this project will also facilitate the future commercialization of this new solar selective coating technology developed in this SIPS project.

14 SOLAR ENERGY↗

Minimizing grid energy consumption in wastewater treatment plants: Towards green energy solutions, water sustainability, and cleaner environment

Wastewater treatment plants (WWTPs) consume significant amount of energy to sustain their operation. From this point, the current study aims to enhance the capacity of these facilities to meet their energy needs by integrating renewable energy sources. The study focused on the investigation of two primary solar energy systems in As Samra WWTP in Jordan. The first system combines parabolic trough collectors (PTCs) with thermal energy storage (TES). This system primarily serves to fulfill the thermal energy demands of the plant by reducing the demands from boiler units, which allows more biogas for electricity generation. The second system is a photovoltaic (PV) system with Lithium-Ion batteries, which directly produces electricity that will be used to cover part of the electrical energy demands of plant. To assess the optimal configuration, two distinct scenarios have been formulated and compared to the current case scenario (SC#1). The first scenario focuses on maximizing the net present value (NPV) and minimizing the levelized cost of electricity (LCOE). The second scenario is centred on minimizing the levelized cost of heat (LCOH). The findings indicate that both scenarios succeeded in reducing the reliance on the grid to a value that reach 1 %. Moreover, they both reduced biogas percentage in energy production from 88 % to approximately 65 % through the integration of the PV system. In terms of thermal demand, SC#2 reduced the reliance on biogas boiler units from 100 % to 25 %, while SC#3 achieved an even more impressive reduction to just 8 %. The best LCOE value was attained in SC#2, at 0.0895 USD/kWh, with an NPV of 10.54 million USD. Conversely, SC# 3 yielded an LCOH value of 0.0432 USD/kWh th compared to 0.0534 USD/kWh th USD for SC#2. In conclusion, despite their relatively high capital and operating costs, SC#2 and SC#3 managed to substantially decrease the annual electricity expenditure from approximately 2 million USD to 86,000 USD and 0 USD, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗