Search NASA⌕ Search

SEARCH · Search NASA

Results for “particulate number”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dust particle velocity measurement

A laser Doppler velocimeter was used to measure the velocity distributions for particles entering a vacuum chamber from the atmosphere through calibrated leaks. The relative number of particles per velocity interval was obtained for particulates of three size distributions and two densities passing through six different leak geometries. The velocity range 15 to 320 meters per second was investigated. Peak particle velocities were found to occur in the 15 to 150 meters per second range depending upon type of particle and leak geometry. A small fraction of the particles were found to have velocities in the 150 to 320 meters per second range.

Thielman, L. O.↗

Alignment of Optical Backscatter Measurements from the EXPORTS Northeast Pacific Field Deployment

Backscattering of light is commonly measured by ocean observing systems, including ships and autonomous platforms, and is used as a proxy for the concentration of water column constituents such as phytoplankton and particulate carbon. Multiple on-going projects involve large numbers of independent measurements of backscatter, as well as other biologically relevant parameters, to understand how biology is changing in time and space throughout the global ocean. Rarely are there sufficient measurements to test how well these instruments are inter-calibrated in real-world deployment conditions. This paper develops a procedure to align multiple independently calibrated backscatter instruments to each other using nearby profiling casts and applies this method to nine instruments deployed during a recent field campaign in the North Pacific during August–September of 2018. This process revealed several incorrect calibrations; post-alignment, all nine instruments aligned extremely well with each other. We also tested an alignment to a deep-water reference and found that this method is generally sufficient but has significant limitations; this procedure lacks the ability to correct instruments measuring only shallow profiles and can only account for additive offsets, not multiplicative changes. These findings highlight the utility of process studies involving several independent measurements of similar parameters in the same area.

North Pacific↗

Remote measurement of pollution

A summary of the major conclusions and recommendations developed by the panels on gaseous air pollution, water pollution, and particulate air pollution is presented. It becomes evident that many of the trace gases are amenable to remote sensing; that certain water pollutants can be measured by remote techniques, but their number is limited; and that a similar approach to the remote measurement of specific particulate pollutants will follow only after understanding of their physical, chemical, and radiative properties is improved. It is also clear that remote sensing can provide essential information in all three categories that can not be obtained by any other means.

Source record↗

Reynolds number influences in aeronautics

Reynolds number, a measure of the ratio of inertia to viscous forces, is a fundamental similarity parameter for fluid flows and therefore, would be expected to have a major influence in aerodynamics and aeronautics. Reynolds number influences are generally large, but monatomic, for attached laminar (continuum) flow; however, laminar flows are easily separated, inducing even stronger, non-monatomic, Reynolds number sensitivities. Probably the strongest Reynolds number influences occur in connection with transitional flow behavior. Transition can take place over a tremendous Reynolds number range, from the order of 20 x 10(exp 3) for 2-D free shear layers up to the order of 100 x 10(exp 6) for hypersonic boundary layers. This variability in transition behavior is especially important for complex configurations where various vehicle and flow field elements can undergo transition at various Reynolds numbers, causing often surprising changes in aerodynamics characteristics over wide ranges in Reynolds number. This is further compounded by the vast parameterization associated with transition, in that any parameter which influences mean viscous flow development (e.g., pressure gradient, flow curvature, wall temperature, Mach number, sweep, roughness, flow chemistry, shock interactions, etc.), and incident disturbance fields (acoustics, vorticity, particulates, temperature spottiness, even electro static discharges) can alter transition locations to first order. The usual method of dealing with the transition problem is to trip the flow in the generally lower Reynolds number wind tunnel to simulate the flight turbulent behavior. However, this is not wholly satisfactory as it results in incorrectly scaled viscous region thicknesses and cannot be utilized at all for applications such as turbine blades and helicopter rotors, nacelles, leading edge and nose regions, and High Altitude Long Endurance and hypersonic airbreathers where the transitional flow is an innately critical portion of the problem.

Bushnell, Dennis M.↗

Photoballistics of volcanic jet activity at Stromboli, Italy

Two night eruptions of the volcano Stromboli were studied through 70-mm photography. Single-camera techniques were used. Particle sphericity, constant velocity in the frame, and radial symmetry were assumed. Properties of the particulate phase found through analysis include: particle size, velocity, total number of particles ejected, angular dispersion and distribution in the jet, time variation of particle size and apparent velocity distribution, averaged volume flux, and kinetic energy carried by the condensed phase. The frequency distributions of particle size and apparent velocities are found to be approximately log normal. The properties of the gas phase were inferred from the fact that it was the transporting medium for the condensed phase. Gas velocity and time variation, volume flux of gas, dynamic pressure, mass erupted, and density were estimated. A CO2-H2O mixture is possible for the observed eruptions. The flow was subsonic. Velocity variations may be explained by an organ pipe resonance. Particle collimation may be produced by a Magnus effect.

Chouet, B.↗

Soot Aerosol Properties in Laminar Soot-Emitting Microgravity Nonpremixed Flames

The spatial distributions and morphological properties of the soot aerosol are examined experimentally in a series of 0-g laminar gas-jet nonpremixed flames. The methodology deploys round jet diffusion flames of nitrogen-diluted acetylene fuel burning in quiescent air at atmospheric pressure. Full-field laser-light extinction is utilized to determine transient soot spatial distributions within the flames. Thermophoretic sampling is employed in conjunction with transmission electron microscopy to define soot microstructure within the soot-emitting 0-g flames. The microgravity tests indicate that the 0-g flames attain a quasi-steady state roughly 0.7 s after ignition, and sustain their annular structure even beyond their luminous flame tip. The measured peak soot volume fractions show a complex dependence on burner exit conditions, and decrease in a nonlinear fashion with decreasing characteristic flow residence times. Fuel preheat by approximately 140 K appears to accelerate the formation of soot near the flame axis via enhanced fuel pyrolysis rates. The increased soot presence caused by the elevated fuel injection temperatures triggers higher flame radiative losses, which may account for the premature suppression of soot growth observed along the annular region of preheated-fuel flames. Electron micrographs of soot aggregates collected in 0-g reveal the presence of soot precursor particles near the symmetry axis at midflame height, The observations also verify that soot primary particle sizes are nearly uniform among aggregates present at the same flame location, but vary considerably with radius at a fixed distance from the burner. The maximum primary size in 0-g is found to be by 40% larger than in 1-g, under the same burner exit conditions. Estimates of the number concentration of primary particles and surface area of soot particulate phase per unit volume of the combustion gases are also made for selected in-flame locations.

Konsur, Bogdan↗

Stratifying Tropical Fires by Land Cover: Insights into Amazonian Fires, Aerosol Loading, and Regional Deforestation

This study analyzes changes in the number of fires detected on forest, grass, and transition lands during the 2002-2009 biomass burning seasons using fire detection data and co-located land cover classifications from the Moderate Resolution Imaging Spectroradiometer (MODIS). We find that the total number of detected fires correlates well with MODIS mean aerosol optical depth (AOD) from year to year, in accord with other studies. However, we also show that the ratio of forest to savanna fires varies substantially from year to year. Forest fires have trended downward, on average, since the beginning of 2006 despite a modest increase in 2007. Our study suggests that high particulate matter loading detected in 2007 was likely due to a large number of savanna/agricultural fires that year. Finally, we illustrate that the correlation between annual Brazilian deforestation estimates and MODIS fires is considerably higher when fires are stratified by MODIS-derived land cover classifications.

TenHoeve, J. E.↗

An automated atmospheric sampling system operating on 747 airliners

An air sampling system that automatically measures the temporal and spatial distribution of selected particulate and gaseous constituents of the atmosphere has been installed on a number of commercial airliners and is collecting data on commercial air routes covering the world. Measurements of constituents related to aircraft engine emissions and other pollutants are made in the upper troposphere and lower stratosphere (6 to 12 km) in support of the Global Air Sampling Program (GASP). Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This system includes specialized instrumentation for measuring carbon monoxide, ozone, water vapor, and particulates, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituents and related flight data are tape recorded in flight for later computer processing on the ground.

Perkins, P.↗

Physical and Optical Characteristics of the October 2010 Haze Event Over Singapore: A Photometric and Lidar Analysis

Trans-boundary biomass burning smoke episodes have increased dramatically during the past 20-30 years and have become an annual phenomenon in the South‐East‐Asia region. On 15th October 2010, elevated levels of fire activity were detected by remote sensing satellites (e.g. MODIS). On the same date, measurements of fine particulate matter (PM2.5) at Singapore and Malaysia found high levels of fine mode particles in the local environment. All these observations were indicative of the initial onset of a smoke episode that lasted for several days. In this work, we investigate the temporal evolution of this smoke episode by analyzing the physical and optical properties of smoke particles with the aid of an AERONET Sun photometer, an MPLNet micropulse lidar, and surface PM2.5 measurements. Elevated levels of fire activity coupled with high aerosol optical depth and PM2.5 were observed over a period of nine days. Increased variability of parameters such as aerosol optical depth, Angstrom exponent number and its fine mode equivalents all indicated high levels of fine particulate presence in the atmosphere. Smoke particle growth due to aging, coagulation and condensation mechanisms was detected during the afternoons and over several days. Retrieved lidar ratios were compatible with the presence of fine particulate within the boundary/aerosol layer. Moreover, retrieved particle size distribution as well as single scattering albedo indicated the prevalence of the fine mode particulate regime as well as particles showing enhanced levels of absorption respectively.

Air quality↗

Results of examination of the nasal mucosa

The olfactory epithelium, but not the nasal respiratory epithelium, of the four pocket mice (Perognathus longimembris) that survived their flight on Apollo XVII showed both diffuse alterations and numerous disseminated focal lesions. The olfactory mucosa of the mouse that died during flight was also affected, but to a minor degree insofar as could be determined. All this was in contrast to the normal appearance of the olfactory mucosa of the numerous control animals. A number of possible causes were considered: systemic or regional infection; inhaled particulate material (seed dust); by-products from the KO2 bed in aerosol or particulate form; gas contaminants originating in the flight package; volatile substances from the dead mouse; weightlessness; and cosmic ray particle radiation. Where feasible, studies were conducted in an effort to rule in or rule out some of these potentially causative factors. No definitive conclusions were reached as to the cause of the lesions in the flight mice.

Kraft, L. M.↗

Hypervelocity impact shield

A hypervelocity impact shield and method for protecting a wall structure, such as a spacecraft wall, from impact with particles of debris having densities of about 2.7 g/cu cm and impact velocities up to 16 km/s are disclosed. The shield comprises a stack of ultra thin sheets of impactor disrupting material supported and arranged by support means in spaced relationship to one another and mounted to cover the wall in a position for intercepting the particles. The sheets are of a number and spacing such that the impacting particle and the resulting particulates of the impacting particle and sheet material are successively impact-shocked to a thermal state of total melt and/or vaporization to a degree as precludes perforation of the wall. The ratio of individual sheet thickness to the theoretical diameter of particles of debris which may be of spherical form is in the range of 0.03 to 0.05. The spacing between adjacent sheets is such that the debris cloud plume of liquid and vapor resulting from an impacting particle penetrating a sheet does not puncture the next adjacent sheet prior to the arrival thereat of fragment particulates of sheet material and the debris particle produced by a previous impact.

Cour-Palais, Burton G.↗

Monitoring Direct Effects of Delta, Atlas, and Titan Launches from Cape Canaveral Air Station

Launches of Delta, Atlas, and Titan rockets from Cape Canaveral Air Station (CCAS) have potential environmental effects that could arise from direct impacts of the launch exhaust (e.g., blast, heat), deposition of exhaust products of the solid rocket motors (hydrogen chloride, aluminum oxide), or other effects such as noise. Here we: 1) review previous reports, environmental assessments, and environmental impact statements for Delta, Atlas, and Titan vehicles and pad areas to clarity the magnitude of potential impacts; 2) summarize observed effects of 15 Delta, 22 Atlas, and 8 Titan launches; and 3) develop a spatial database of the distribution of effects from individual launches and cumulative effects of launches. The review of previous studies indicated that impacts from these launches can occur from the launch exhaust heat, deposition of exhaust products from the solid rocket motors, and noise. The principal effluents from solid rocket motors are hydrogen chloride (HCl), aluminum oxide (Al2O3), water (H2O), hydrogen (H2), carbon monoxide (CO), and carbon dioxide (CO2). The exhaust plume interacts with the launch complex structure and water deluge system to generate a launch cloud. Fall out or rain out of material from this cloud can produce localized effects from acid or particulate deposition. Delta, Atlas, and Titan launch vehicles differ in the number and size of solid rocket boosters and in the amount of deluge water used. All are smaller and use less water than the Space Shuttle. Acid deposition can cause damage to plants and animals exposed to it, acidify surface water and soil, and cause long-term changes to community composition and structure from repeated exposure. The magnitude of these effects depends on the intensity and frequency of acid deposition.

Schmalzer, Paul A.↗

Application of laser anemometry to cryogenic wind tunnels

The installation and tests conducted with the laser Doppler and transit anemometer in the 0.3-Meter Transonic Cryogenic Tunnel are described. Using residual particulates in the flow field, a series of free stream velocity measurements were conducted which agreed to within 1-percent of predicted values for a range of Mach numbers, 0.2 to 0.85, and temperatures, 100 to 250 K. Measurements about a shock wave provided an estimate of scattering particulate size of 4 microns or less. The particle concentration is approximately 3 x 10 to the 5th to 1.6 x 10 to the 6th/cu m. Necessary isolation of the plenum wall windows from ambient air with slightly positive pressure of dry nitrogen gas to prevent condensation on the window surface was achieved. This was accomplished through the use of large enclosures fixed to the tunnel wall. A second method used an additional sheet of thin plate glass to create the dry gas pocket next to the plenum window. The installation of a laser anemometer in the National Transonic Facility is examined. The laser transit anemometer has been tentatively selected for the initial entry because of its compact laser-optics package.

Hunter, W. W., Jr.↗

TPSAS-NF1676L-28148-DND

Currently, ocean carbon biomass is estimated from ocean color measurements primarily through particulate backscatter coefficients (bbp). Small non-algal particles contribute significantly to bbp due to the fact that small particles scatter more isotropically while bigger particles scatter mostly in the forward direction. CALIPSO’s ocean subsurface cross polarization measurements (Figure 1) are not sensitive to small particles far less than 2 microns in size since these particles rarely cause depolarization. Thus, cross polarization backscatter is contributed mostly by larger, depolarizing phytoplankton particles. This is why CALIPSO’s cross polarization has much larger contrasts comparing with MODIS reflectance (CALIPSO cross polarization is very weak in Gyres and much stronger in high latitudes, See Figure 1). CALIPSO cross-polarization measurements in the Southern Oceans also suggest that water cloud droplet number concentration covaries with phytoplankton carbon biomass (Figure 2), but it has less correlation with particulate organic carbon (POC) (Figure 2) and chlorophyll concentration. The study also agrees with water cloud droplet size retrieved from Parasol’s polarization measurements.

Yongxiang Hu↗

Life Support Filtration System Trade Study for Deep Space Missions

The National Aeronautics and Space Administrations (NASA) technical developments for highly reliable life support systems aim to maximize the viability of long duration deep space missions. Among the life support system functions, airborne particulate matter filtration is a significant driver of launch mass because of the large geometry required to provide adequate filtration performance and because of the number of replacement filters needed to a sustain a mission. A trade analysis incorporating various launch, operational and maintenance parameters was conducted to investigate the trade-offs between the various particulate matter filtration configurations. In addition to typical launch parameters such as mass, volume and power, the amount of crew time dedicated to system maintenance becomes an increasingly crucial factor for long duration missions. The trade analysis evaluated these parameters for conventional particulate matter filtration technologies and a new multi-stage particulate matter filtration system under development by NASAs Glenn Research Center. The multi-stage filtration system features modular components that allow for physical configuration flexibility. Specifically, the filtration system components can be configured in distributed, centralized, and hybrid physical layouts that can result in considerable mass savings compared to conventional particulate matter filtration technologies. The trade analysis results are presented and implications for future transit and surface missions are discussed.

particulate matter filtration↗

Camera/photometer results

Camera/photometer systems have been constructed for analyzing particulate contamination on STS-2. The systems contained two 16-mm photographic cameras to make stereoscopic observation of contaminant particles and the background. During the STS-2 mission, 102 photographic exposures were obtained under conditions suitable for recording particulate contamination. Attention is given to a breakdown of STS-2 camera/photometer data with the number of particles observed per frame, a correlation of observed contamination with mission elapsed time broken into 5-hr segments, and a correlation of observed contamination with onboard spacecraft events.

Clifton, K. S.↗

The Efficiency of the Smoke Meter at Characterizing Engine Emissions

The effectiveness of a smoke meter's ability to characterize the particulate emissions of a jet fuel combustor was evaluated using the University of Missouri-Rolla Mobile Aerosol Sampling System (UMR-MASS). A burner simulating an advanced jet engine combustor design was used to generate typical combustion particulates, which were then analyzed by the smoke meter. The same particulates were then size discriminated to ascertain the effective impact of aerosol diameter on smoke number readings.

Paladino, Jonathan D.↗

Characterizing Fit Factor of a One Size Fits-Most Emergency Mask using Subjects with Smaller Neck Circumferences

The Emergency Mask (EM) is an integral part of fire response on ISS, Orion and Gateway. The EM is a hood type protection respirator sealing around the subject’s neck, with an additional nose cup covering the subject’s oral nasal region. When integrated with a pair of Fire Cartridges (FCs), this system can be used to provide safe breathing air in a post-fire environment. The initial EM was certified as a ‘one size fits most’, however a recent requirements scrub discovered that the neck circumferences of the smallest possible crew population were not included in the initial requirement set. The test described in this paper uses the same slightly modified industry standard respirator test called a ‘Fit Factor’ used to certify the existing EM for larger subjects. Tests were performed on eight test subjects with neck circumference smaller than the initial EM requirement to determine if the current EM provided adequate protection during post-fire scenarios. The test included subjects donning an EM and then performing a number of head movements in a tent filled with approximately 50,000 particles/cm3 of smoke particulate. During these motions, particulate measurements were obtained from within the EM and compared with particulate measurements in the surrounding environment to determine the protection the EM provided in a simulated post-fire environment. This paper provides descriptions of the test hardware, methodology and results, which have provided rationale to design and build an EM to accommodate subjects with smaller necks.

Respirator↗