Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

DEVELOPMENT OF A SOFTWARE DESIGN TOOL FOR HYBRID SOLAR-GEOTHERMAL HEAT PUMP SYSTEMS IN HEATING- AND COOLING-DOMINATED BUILDINGS

This project provides an easy-to-use, menu-driven, software tool for designing hybrid solar-geothermal heat pump systems (GHP) for both heating- and cooling-dominated buildings. No such design tool currently exists. In heating-dominated buildings, the design approach takes advantage of glazed solar collectors to effectively balance the annual thermal loads on the ground with renewable solar energy. In cooling-dominated climates, the design approach takes advantage of relatively low-cost, unglazed solar collectors as the heat rejecting component. The primary benefit of hybrid GHPs is the reduced initial cost of the ground heat exchanger (GHX). Furthermore, solar thermal collectors can be used to balance the ground loads over the annual cycle, thus making the GHX fully sustainable; in heating-dominated buildings, the hybrid energy source (i.e., solar) is renewable, in contrast to a typical fossil fuel boiler or electric resistance as the hybrid component; in cooling-dominated buildings, use of unglazed solar collectors as a heat rejecter allows for passive heat rejection, in contrast to a cooling tower that consumes a significant amount of energy to operate, and hybrid GHPs can expand the market by allowing reduced GHX footprint in both heating- and cooling-dominated climates. The design tool allows for the straight-forward design of innovative GHP systems that currently pose a significant design challenge. The project lays the foundations for proper and reliable design of hybrid GHP systems, overcoming a series of difficult and cumbersome steps without the use of a system simulation approach, and without an automated optimization scheme. As new technologies and design concepts emerge, sophisticated design tools and methodologies must accompany them and be made usable for practitioners. Lack of reliable design tools results in reluctance of practitioners to implement more complex systems. A menu-driven software tool for the design of hybrid solar GHP systems is provided that is based on mathematically robust, validated models. An automated optimization tool is used to balance ground loads and incorporated into the simulation engine. With knowledge of the building loads, thermal properties of the ground, the borehole heat exchanger configuration, the heat pump peak hourly and seasonal COP for heating and cooling, the critical heat pump design entering fluid temperature, and the thermal performance of a solar collector, the total GHX length can be calculated along with the area of a supplemental solar collector array and the corresponding reduced GHX length. An economic analysis module allows for the calculation of the lowest capital cost combination of solar collector area and GHX length. ACKNOWLEDGMENTS This project was funded by the United States Department of Energy DOE-DE-FOA-0000116, Recovery Act Geothermal Technologies Program: Ground Source Heat Pumps. The lead contractor, The University of Hartford, was supported by The University of Dayton, and the Oak Ridge National Laboratories. All funding and support for this project as well as contributions of graduate and undergraduate students from the contributing institutions are gratefully acknowledged.

14 SOLAR ENERGY↗

Performance of Microreactor Test Article with Embedded Sensors During Testing in The Single Primary Heat Extraction and Removal Emulator

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes that use passive heat flow, increasing the surface area for heat transfer without requiring active coolant flow through the reactor core. Additional experimental testing is required to understand the heat rejection limitations of heat pipes and thermal stresses in the monolithic core block due to significant temperature gradients. This report describes the initial characterization and testing of a stainless-steel test article that was fabricated with embedded sensors to measure heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing to simulate nuclear heating. The electrically heated testing was performed in the Single Primary Heat Extraction and Removal Emulator facility located at Idaho National Laboratory. The ultimate goals of this work are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify the heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. Initial tests focused on the feasibility of using advanced fiber-optic sensors and other sensor technologies to improve the understanding of temperature and strain distributions within the electrically heated experiments. However, these sensing capabilities could benefit the broader microreactor community if the sensors could be used to monitor component and system health during nuclear operations to inform a limited number of microreactor operators, ultimately reducing operation and maintenance costs and moving toward semiautonomous operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A passive thermosyphon heat exchanger for residential solar installations

The paper details the development of a thermosyphon water-to-air heat exchanger for residential solar applications. Modeling techniques used in the analysis of thermosyphon performance are included, as well as test results from laboratory-scale experiments. In addition, a description of the initial full-scale prototype is presented, along with experimental test results. Present areas of development are discussed, with an economic comparison of thermosyphon and forced convection heating systems also being included.

Franklin, J. L.↗

Hybrid Solar GHP Simulator

This project provides an easy-to-use, menu-driven, software tool for designing hybrid solar-geothermal heat pump systems (GHP) for both heating- and cooling-dominated buildings. No such design tool currently exists. In heating-dominated buildings, the design approach takes advantage of glazed solar collectors to effectively balance the annual thermal loads on the ground with renewable solar energy. In cooling-dominated climates, the design approach takes advantage of relatively low-cost, unglazed solar collectors as the heat rejecting component. The primary benefit of hybrid GHPs is the reduced initial cost of the ground heat exchanger (GHX). Furthermore, solar thermal collectors can be used to balance the ground loads over the annual cycle, thus making the GHX fully sustainable; in heating-dominated buildings, the hybrid energy source (i.e., solar) is renewable, in contrast to a typical fossil fuel boiler or electric resistance as the hybrid component; in cooling-dominated buildings, use of unglazed solar collectors as a heat rejecter allows for passive heat rejection, in contrast to a cooling tower that consumes a significant amount of energy to operate, and hybrid GHPs can expand the market by allowing reduced GHX footprint in both heating- and cooling-dominated climates. The design tool allows for the straight-forward design of innovative GHP systems that currently pose a significant design challenge. The project lays the foundations for proper and reliable design of hybrid GHP systems, overcoming a series of difficult and cumbersome steps without the use of a system simulation approach, and without an automated optimization scheme. As new technologies and design concepts emerge, sophisticated design tools and methodologies must accompany them and be made usable for practitioners. Lack of reliable design tools results in reluctance of practitioners to implement more complex systems. A menu-driven software tool for the design of hybrid solar GHP systems is provided that is based on mathematically robust, validated models. An automated optimization tool is used to balance ground loads and incorporated into the simulation engine. With knowledge of the building loads, thermal properties of the ground, the borehole heat exchanger configuration, the heat pump peak hourly and seasonal COP for heating and cooling, the critical heat pump design entering fluid temperature, and the thermal performance of a solar collector, the total GHX length can be calculated along with the area of a supplemental solar collector array and the corresponding reduced GHX length. An economic analysis module allows for the calculation of the lowest capital cost combination of solar collector area and GHX length.

Yavuzturk, Cy↗

Warming up human body by nanoporous metallized polyethylene textile

Space heating accounts for the largest energy end-use of buildings that imposes significant burden on the society. The energy wasted for heating the empty space of the entire building can be saved by passively heating the immediate environment around the human body. Here, we demonstrate a nanophotonic structure textile with tailored infrared (IR) property for passive personal heating using nanoporous metallized polyethylene. By constructing an IR-reflective layer on an IR-transparent layer with embedded nanopores, the nanoporous metallized polyethylene textile achieves a minimal IR emissivity (10.1%) on the outer surface that effectively suppresses heat radiation loss without sacrificing wearing comfort. This enables 7.1 °C decrease of the set-point compared to normal textile, greatly outperforming other radiative heating textiles by more than 3 °C. This large set-point expansion can save more than 35% of building heating energy in a cost-effective way, and ultimately contribute to the relief of global energy and climate issues.

36 MATERIALS SCIENCE↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capillary heat transport and fluid management device

A passive heat transporting and fluid management apparatus including a housing in the form of an extruded body member having flat upper and lower surfaces is disclosed. A main liquid channel and at least two vapor channels extend longitudinally through the housing from a heat input end to a heat output end. The vapor channels have sintered powdered metal fused about the peripheries to form a porous capillary wick structure. A substantial number of liquid arteries extend transversely through the wicks adjacent the respective upper and lower surfaces of the housing, the arteries extending through the wall of the housing between the vapor channels and the main liquid channel and open into the main liquid channel. Liquid from the main channel enters the artery at the heat input end, wets the wick and is vaporized. When the vapor is cooled at the heat output end, the condensed vapor refills the wick and the liquid reenters the main liquid channel.

James W Owen↗

A Combined Water and CO2 Direct Air Capture System (CRADA 521)

The primary objective of this project is to demonstrate the outstanding technical and economic performance of a transformational Hybrid DAC (HDAC) technology that simultaneously captures CO2 and water from the air. Air is passed over a CO2 selective sorbent to remove ≥85% of the CO2 from the air stream. The atmospheric water extraction (AWE) section of the unit utilizes a novel isothermal pressure swing regeneration cycle with desiccant beds thermally coupled by heat pipes that provide a passive heat transfer mechanism to “cancel” the heat of water vapor adsorption. By proving system performance through this demonstration project, our initial technoeconomic analysis (TEA) will be validated, showing that HDAC technology: 1) is deployable in many more locations with limited water resources, 2) improves the financial returns, and 3) reduces risks from volatility in the price of CO2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum Operation of Consolidated Heat Pipe (CHP) for Fission Surface Power

Consolidated Heat Pipe (CHP) is a new technology that enables direct thermal power delivery to the hot-end of a Stirling engine using a heat pipe--a two phase passive heat transfer device. CHP was developed after the efforts of the Kilopower Using Stirling TechnologY (KRUSTY) test where a heat pipe was used to deliver thermal power from a fission-basedreactor to a Stirling engine to produce 1 kWe of useable electrical power in 2018. Large thermal losses were noted during the KRUSTY test where a temperature drop of 145 °C was measured between the heat pipe’s condenser and the engine’s hot-end. The Consolidated Heat Pipe was designed to address and mitigate this temperature loss. CHP was designed, built and tested at the Glenn Research Center (GRC). The initial test was performed in ambient air conditions, and the results were presented in “Consolidation of a Sodium Heat Pipe and Stirling Engine for Fission Surface Power” at the Thermal Fluids Analysis Workshop in 2023. Researchers at GRC have tested this technology again in a vacuum environment in 2024. Results show that the heat pipe and the hot-end of the Stirling engine are isothermal with a minimal temperature differential of approximately 2.5 °C in varying operational states. The Consolidated Heat Pipe technology has proven to be an efficient way of delivering thermal power directly to Stirling engines.

Greeta J Thaikattil↗

The Fast Modular Reactor (FMR) - Development Plan of a New 50 MWe Gas-cooled Fast Reactor

General Atomics Electromagnetic Systems (GA-EMS) will be developing a new 50-megawatt electric (MWe) fast modular reactor (FMR), under the Department of Energy’s (DOE’s) Advanced Reactor Demonstration Program (ARDP), Advanced Reactor Concepts 2020 (ARC-20) development pathway, that provides safe, carbon free electricity, capable of incremental capacity additions. A modular design allows it to be factory-built and assembled on-site to keep the cost of capital low, while the dry-cooling facilitates siting to complement renewables in nearly any location. GA-EMS is committed to commercialization of the proposed reactor, with a demonstration by 2030, and deployment by the mid-2030s. The ultimate goal of the design is to develop flexible and dispatchable carbon-free power source for the 2035 US electricity market. The GAEMS- led team will verify that simplified characteristics (e.g., inert helium gas coolant, pellet-loaded fuel rod, installation-free of heat sink requirements, small and passive heat removal systems) of the FMR will result in a safe, maintainable, cost-effective, distributed, nuclear energygenerating station. Three key specific project objectives for the next three years include: Development of the conceptual design of the 50- MWe FMR plant, Achievement of Technology Readiness Level (TRL) 4 for key system and component technologies through in-pile tests, out-of-pile tests, and numerical experiments; and Development of robust techno-economic analysis (TEA) and pre-application licensing approach necessary for timely demonstration and eventual commercialization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Assessment of MELCOR 2.1: Containment Thermal-Hydraulic Tests in the Heissdampfreaktor (HDR) Facility

MELCOR is being developed at Sandia National Laboratories for the U.S. Nuclear Regulatory Commission. MELCOR is a fully integrated code (encompassing the reactor coolant system and the containment building) that models the progression of postulated accidents in light water reactor power plants. It provides a capability for independently auditing analyses submitted by reactor manufacturers and utilities. In order to assess the adequacy of containment thermal - hydraulic modeling incorporated in the MELCOR code, a key containment test facility was analyzed. This report documents MELCOR code calculations for simulating steam - water blowdown tests performed in the Heissdampfreaktor ( HDR) de-commissioned containment facility located near Frankfurt , Germany . These tests are a series of blowdown experiments in a large scaled test facility ; including some tests with the addition of hydrogen release which are intended to simulate a variety of postulated break s inside large containment buildings. The key objectives of this MELCOR assessment are to study: (1) the expansion and transport of high energy steam - water releases, (2) heat and mass transfer to structural passive heat sinks, and (3) containment gas mixing and stratification. Moreover, MELCOR results are compared to the CONTAIN code for the same tests.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of the MELCOR code to design basis PWR large dry containment analysis.

The MELCOR computer code has been developed by Sandia National Laboratories under USNRC sponsorship to provide capability for independently auditing analyses submitted by reactor manufactures and utilities. MELCOR is a fully integrated code (encompassing the reactor coolant system and the containment building) that models the progression of postulated accidents in light water reactor power plants. To assess the adequacy of containment thermal-hydraulic modeling incorporated in the MELCOR code for application to PWR large dry containments, several selected demonstration designs were analyzed. This report documents MELCOR code demonstration calculations performed for postulated design basis accident (DBA) analysis (LOCA and MSLB) inside containment, which are compared to other code results. The key processes when analyzing the containment loads inside PWR large dry containments are (1) expansion and transport of high mass/energy releases, (2) heat and mass transfer to structural passive heat sinks, and (3) containment pressure reduction due to engineered safety features. A code-to-code benchmarking for DBA events showed that MELCOR predictions of maximum containment loads were equivalent to similar predictions using a qualified containment code known as CONTAIN. This equivalency was found to apply for both single- and multi-cell containment models.

97 MATHEMATICS AND COMPUTING↗

Storage systems for solar thermal power

The development status is reviewed of some thermal energy storage technologies specifically oriented towards providing diurnal heat storage for solar central power systems and solar total energy systems. These technologies include sensible heat storage in caverns and latent heat storage using both active and passive heat exchange processes. In addition, selected thermal storage concepts which appear promising to a variety of advanced solar thermal system applications are discussed.

Calogeras, J. E.↗

Storage systems for solar thermal power

A major constraint to the evolution of solar thermal power systems is the need to provide continuous operation during periods of solar outage. A number of high temperature thermal energy storage technologies which have the potential to meet this need are currently under development. The development status is reviewed of some thermal energy storage technologies specifically oriented towards providing diurnal heat storage for solar central power systems and solar total energy systems. These technologies include sensible heat storage in caverns and latent heat storage using both active and passive heat exchange processes. In addition, selected thermal storage concepts which appear promising to a variety of advanced solar thermal system applications are discussed.

Calogeras, J. E.↗

Solar Schematic

The home shown at right is specially designed to accommodate solar heating units; it has roof planes in four directions, allowing placement of solar collectors for best exposure to the sun. Plans (bottom) and complete working blueprints for the solar-heated house are being marketed by Home Building Plan Service, Portland, Oregon. The company also offers an inexpensive schematic (center) showing how a homeowner only moderately skilled in the use of tools can build his own solar energy system, applicable to new or existing structures. The schematic is based upon the design of a low-cost solar home heating system built and tested by NASA's Langley Research Center; used to supplement a warm-air heating system, it can save the homeowner about 40 percent of his annual heating bill for a modest investment in materials and components. Home Building Plan Service saved considerable research time by obtaining a NASA technical report which details the Langley work. The resulting schematic includes construction plans and simplified explanations of solar heat collection, collectors and other components, passive heat factors, domestic hot water supply and how to work with local heating engineers.

Source record↗

Development of Scaling Criteria for Modeling Condensation in Horizontal Tubes Using Reduced Pressure System and Simulant Fluid

Most of the currently operating nuclear power plants (NPPs), generation-II and III, are equipped with active safety systems, which raises concerns regarding those safety systems' operational reliability and the suitability of the accidents prevention measures. Following the severe accidents at nuclear power plants at Three Mile Island, Chernobyl, and recently in Fukushima some advance Pressurized Water Reactors (PWRs) have adopted passively cooled steam generator natural circulation system to remove the decay heat passively through the steam generator (SG). This is done by condensing steam from the steam generator inside a heat exchanger submerged in a tank of water or an air cooled system. The APR+ (Advanced Power Reactor Plus), which is currently being developed in South Korea, has adopted a Passive Auxiliary Feedwater System (PAFS), which removes the decay heat through the steam generator replacing the conventional active auxiliary feedwater system. The main part of the PAFS, in where the steam condenses, is the Passive Condensation Heat Exchanger (PCHX). The steam condenses under high pressure (7.4 MPa, 290 deg. C) in 8.4 m long horizontal tube, with 3 degrees inclination, with inner diameter of 44.8 mm and wall thickness of 3 mm. The PCHX consists of 4 bundles, each bundle has 60 condensation tubes. The performance of the PCHX performance should be evaluated. Condensation has been extensively studied; however, most previous experimental work was directed to low pressure (i.e., near atmospheric pressure) and small condensation tubes. Moreover, studies on the horizontal type heat exchanger are limited, since previous safety systems and experimentation work were directed to the vertical type heat exchangers. Due to the high construction cost of a full size high pressure condensation experiment, a reduced-size reduced-pressure condensation experiment is suggested to evaluate the heat removal performance of a condensation tube of the PAFS heat exchanger. A scaling methodology to be established to design a reduced-size reduced-pressure condensation experiment. This study attempts to develop a scaling criteria for the PAFS condensation system, and to apply it for modeling a high pressure water system by a low pressure Freon system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermochromic Halide Perovskite Windows with Ideal Transition Temperatures

Abstract Urban centers across the globe are responsible for a significant fraction of energy consumption and CO 2 emission. As urban centers continue to grow, the popularity of glass as cladding material in urban buildings is an alarming trend. Dynamic windows reduce heating and cooling loads in buildings by passive heating in cold seasons and mitigating solar heat gain in hot seasons. Here, reduced energy consumption in highly glazed buildings in a mesoscopic building energy model is demonstrated when thermochromic windows are employed. Savings are realized across eight disparate climate zones of the United States. The model is used to determine ideal critical transition temperatures of 20–27.5 °C for thermochromic windows based on metal halide perovskite materials. Ideal transition temperatures are realized experimentally in composite metal halide perovskite films composed of perovskite crystals and an adjacent reservoir phase. The transition temperature is controlled by cointercalating methanol, instead of water, with methylammonium iodide and tailoring the hydrogen‐bonding chemistry of the reservoir phase. Thermochromic windows based on metal halide perovskites represent a clear opportunity to mitigate the effects of energy‐hungry buildings.

14 SOLAR ENERGY↗

A CHANDRA STUDY OF THE RADIO GALAXY NGC 326: WINGS, OUTBURST HISTORY, AND ACTIVE GALACTIC NUCLEUS FEEDBACK

NGC 326 is one of the most prominent 'X'- or 'Z'-shaped radio galaxies (XRGs/ZRGs) and has been the subject of several studies attempting to explain its morphology through either fluid motions or reorientation of the jet axis. We examine a 100 ks Chandra X-Ray Observatory exposure and find several features associated with the radio galaxy: a high-temperature front that may indicate a shock, high-temperature knots around the rim of the radio emission, and a cavity associated with the eastern wing of the radio galaxy. A reasonable interpretation of these features in light of the radio data allows us to reconstruct the history of the active galactic nucleus (AGN) outbursts. The active outburst was likely once a powerful radio source which has since decayed, and circumstantial evidence favors reorientation as the means to produce the wings. Because of the obvious interaction between the radio galaxy and the intracluster medium and the wide separation between the active lobes and wings, we conclude that XRGs are excellent sources in which to study AGN feedback in galaxy groups by measuring the heating rates associated with both active and passive heating mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗