Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Coherent Transition Radiation from Transversely Modulated Electron Beams

A transverse laser-shaping optical setup using microlens arrays (MLAs), previously developed and employed at Argonne Wakefield Accelerator (AWA), allows the formation of both highly uniform and modulated (patterned) beams. In the latter case, transverse modulation is imposed in the sub-millimeter scale. In the present study, we report the simulations of backward coherent transition radiation (CTR) emitted from a transversely modulated beam. We compare the case of a uniform round beam against different transverse modulation wavelengths by generating CTR on a steel target and measuring the autocorrelation function of the resulting radiation with an interferometer. We particularly focus on the differences between round and patterned beam distributions and discuss possible future applications of this setup in THz radiation generation.

43 PARTICLE ACCELERATORS↗

Ion trapping study in eRHIC

The ion trapping effect is an important beam dynamics issue in energy recovery linac (ERL). The ionized residue gas molecules can accumulate at the vicinity of the electron beam path and deteriorate the quality of the electron beam. In this paper, we present calculation results to address this issue in eRHIC and find best beam pattern to eliminate this effect. eRHIC is the future electron ion collider(EIC), which collides 5GeV to 30GeV electron beam from a new electron accelerator with the ion beam from existing RHIC ring. The electron accelerator adopts a multi-pass ERL, which contains 6 passes with 2 linacs per pass. The electron impacted ionization effect needs attention to ensure the quality of the electron beam. The high energy electrons ionize the residue gas in beam pipe. These ions may accumulate and are 'trapped' near the axis of the pipe where the electron beam passes, due to the interaction with the electron beam. The concentration of the ion may produce noticeable space charge field that affects the electron beam and neutralize the electron beam in the linacs. In the paper, we start with cross section of the ionization process and calculate the accumulation time, which are followed by the modeling to determine the criteria of the ion trapping. The ion trapping effect is determined by the longitudinal configuration of the electron bunches. The effect can be reduced or mitigate by some proper electron beam patterns. We will present these patterns with a linearized model. We present the linearized calculation on the ion motion in the cavity of multi-pass ERL and determine the stability of the ion motion from the results. We conclude that the ionized molecules won't accumulated in eRHIC linacs except both 40m ends. Electro-static clearing electrodes should be installed in those regions to remove the ions from accumulation.

43 PARTICLE ACCELERATORS↗

Planar patterned media fabricated by ion irradiation into CrPt{sub 3} ordered alloy films

Planar patterned media using CrPt{sub 3} ordered alloy films were fabricated by Ar{sup +} or Kr{sup +} ion irradiation through nanoimprinted or electron beam lithography made masks. CrPt{sub 3} ordered alloy film on fused quartz substrate exhibits a large perpendicular anisotropy of 5x10{sup 6} erg/cc and a large coercivity of 12 kOe, and we found that its magnetic order (magnetization) was completely suppressed by a quite low Ar{sup +} or Kr{sup +} ion dose of about 1-2x10{sup 14} ions/cm{sup 2}. Magnetic force microscope image of the ion-beam patterned CrPt{sub 3} with a bit size of 90x90 nm showed clear magnetic contrast in nonirradiated regions, while no magnetic contrast in irradiated regions. The read-back waveform taken from an ion-beam patterned CrPt{sub 3} disk with 600 nm patterning pitch showed sharp signal transition between irradiated and nonirradiated regions, which indicates the possibility of high-density planar patterned media using CrPt{sub 3} ordered alloy.

36 MATERIALS SCIENCE↗

Simons Observatory: characterizing the Large Aperture Telescope Receiver with radio holography

Here, we present near-field radio holography measurements of the Simons Observatory Large Aperture Telescope Receiver optics. These measurements demonstrate that radio holography of complex millimeter-wave optical systems comprising cryogenic lenses, filters, and feed horns can provide detailed characterization of wave propagation before deployment. We used the measured amplitude and phase, at 4 K, of the receiver near-field beam pattern to predict two key performance parameters: 1) the amount of scattered light that will spill past the telescope to 300 K and 2) the beam pattern expected from the receiver when fielded on the telescope. These cryogenic measurements informed the removal of a filter, which led to improved optical efficiency and reduced sidelobes at the exit of the receiver. Holography measurements of this system suggest that the spilled power past the telescope mirrors will be less than 1%, and the main beam with its near sidelobes are consistent with the nominal telescope design. This is the first time such parameters have been confirmed in the lab prior to deployment of a new receiver. This approach is broadly applicable to millimeter and submillimeter instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: A novel leaf sequencing optimization algorithm which considers previous underdose and overdose events for MLC tracking radiotherapy

Purpose: Multileaf collimator (MLC) tracking radiotherapy is complex as the beam pattern needs to be modified due to the planned intensity modulation as well as the real-time target motion. The target motion cannot be planned; therefore, the modified beam pattern differs from the original plan and the MLC sequence needs to be recomputed online. Current MLC tracking algorithms use a greedy heuristic in that they optimize for a given time, but ignore past errors. To overcome this problem, the authors have developed and improved an algorithm that minimizes large underdose and overdose regions. Additionally, previous underdose and overdose events are taken into account to avoid regions with high quantity of dose events. Methods: The authors improved the existing MLC motion control algorithm by introducing a cumulative underdose/overdose map. This map represents the actual projection of the planned tumor shape and logs occurring dose events at each specific regions. These events have an impact on the dose cost calculation and reduce recurrence of dose events at each region. The authors studied the improvement of the new temporal optimization algorithm in terms of the L1-norm minimization of the sum of overdose and underdose compared to not accounting for previous dose events. For evaluation, the authors simulated the delivery of 5 conformal and 14 intensity-modulated radiotherapy (IMRT)-plans with 7 3D patient measured tumor motion traces. Results: Simulations with conformal shapes showed an improvement of L1-norm up to 8.5% after 100 MLC modification steps. Experiments showed comparable improvements with the same type of treatment plans. Conclusions: A novel leaf sequencing optimization algorithm which considers previous dose events for MLC tracking radiotherapy has been developed and investigated. Reductions in underdose/overdose are observed for conformal and IMRT delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Relativistic Shear Flow between Electron–Ion and Electron–Positron Plasmas and Astrophysical Applications

We present particle-in-cell simulation results of relativistic shear boundary layers between electron–ion and electron–positron plasmas and discuss their potential applications to astrophysics. Specifically, we find that in the case of a fast electron–positron spine surrounded by a slow-moving or stationary electron–ion sheath, lepton acceleration proceeds in a highly anisotropic manner due to electromagnetic fields created at the shear interface. While the highest-energy leptons still produce a beaming pattern (as seen in the quasi-stationary frame of the sheath) of order 1/Γ, where Γ is the bulk Lorentz factor of the spine, for lower-energy particles, the beaming is much less pronounced. This is in stark contrast to the case of pure electron–ion shear layers, in which anisotropic particle acceleration leads to significantly narrower beaming patterns than 1/Γ for the highest-energy particles. In either case, shear-layer acceleration is expected to produce strongly angle-dependent lepton (hence, emanating radiation) spectra, with a significantly harder spectrum in the forward direction than viewed from larger off-axis angles, much beyond the regular Doppler boosting effect from a co-moving isotropic lepton distribution. This may solve the problem of the need for high (and apparently arbitrarily chosen) minimum Lorentz factors of radiating electrons, often plaguing current blazar and GRB jet modeling efforts.

79 ASTRONOMY AND ASTROPHYSICS↗

High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout

We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High performance terahertz metasurface quantum-cascade VECSEL with an intra-cryostat cavity

A terahertz quantum-cascade (QC) vertical-external-cavity surface-emitting-laser (VECSEL) is demonstrated with over 5 mW power in continuous-wave and single-mode operation above 77 K, in combination with a near-Gaussian beam pattern with full-width half-max divergence as narrow as ~5° × 5°, with no evidence of thermal lensing. This is realized by creating an intra-cryostat VECSEL cavity to reduce the cavity loss and designing an active focusing metasurface reflector with low power dissipation for efficient heat removal. Compared with a conventional quantumcascade laser based on a metal-metal waveguide, the intra-cryostat QC-VECSEL exhibits significant improvements in both output power level and beam pattern. Also, the intra-cryostat configuration newly allows evaluation of QC-VECSEL operation vs. temperature, showing a maximum pulsed mode operating temperature of 129 K. While the threshold current density in the QC-VECSEL is worse in comparison to a conventional edge-emitting metal-metal waveguide QClaser, the beam quality, slope efficiency, maximum power, and thermal resistance are all significantly improved.

47 OTHER INSTRUMENTATION↗

Terahertz metasurface quantum-cascade VECSELs: theory and performance

A longstanding challenge for terahertz quantum-cascade (QC) lasers is achieving both a high power and high-quality beam pattern, this is due in part due to their use of sub-wavelength metallic waveguides. Recently, the vertical-external-cavity surface-emitting laser (VECSEL) concept was demonstrated for the first time in the terahertz range and for a QC-laser. This is enabled by the development of an amplifying metasurface reflector capable of coupling incident free-space THz radiation to the QC-laser material such that it is amplified and re-radiated. The THz metasurface QC-VECSEL initiates a new approach for making QC-lasers with high power and excellent beam pattern. Furthermore, the ability to engineer the electromagnetic phase, amplitude, and polarization response of the metasurface enables lasers with new functionality. Our article provides an overview of the fundamental theory, design considerations, and recent results for high-performance THz QC-VECSELs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of irradiation configuration in laser fusion utilizing self-organizing electrodynamic system

A simple numerical method to determine an optimum beam configuration for highly uniform irradiation is proposed for direct-drive laser fusion systems and is applied to an arbitrary number of laser beams, N{sub B}. Driven by the Coulomb repulsion force, N{sub B} randomly distributed like charges move on a spherical surface to settle with a stable configuration having the minimum Coulomb energy for the system. Such resultant charge configurations practically do not depend on the initial conditions, and thus the solutions are very robust and unique. The irradiation uniformity is numerically assessed by overlapping N{sub B} beam patterns and calculating the laser absorption based on various spatial absorption patterns for the individual beams. The present method provides some improved illumination configurations for laser fusion compared with previously proposed designs. In particular, new coordinates for N{sub B}=48 and 72 are found to give an extraordinarily higher uniformity than for other numbers of N{sub B}. The influence of system imperfection on the irradiation uniformity is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress in developing a superconducting accelerator for efficient eBeam and X-ray production

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

43 PARTICLE ACCELERATORS↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

BEAM-FORMING ERRORS IN MURCHISON WIDEFIELD ARRAY PHASED ARRAY ANTENNAS AND THEIR EFFECTS ON EPOCH OF REIONIZATION SCIENCE

Accurate antenna beam models are critical for radio observations aiming to isolate the redshifted 21 cm spectral line emission from the Dark Ages and the Epoch of Reionization (EOR) and unlock the scientific potential of 21 cm cosmology. Past work has focused on characterizing mean antenna beam models using either satellite signals or astronomical sources as calibrators, but antenna-to-antenna variation due to imperfect instrumentation has remained unexplored. We characterize this variation for the Murchison Widefield Array (MWA) through laboratory measurements and simulations, finding typical deviations of the order of ±10%–20% near the edges of the main lobe and in the sidelobes. We consider the ramifications of these results for image- and power spectrum-based science. In particular, we simulate visibilities measured by a 100 m baseline and find that using an otherwise perfect foreground model, unmodeled beam-forming errors severely limit foreground subtraction accuracy within the region of Fourier space contaminated by foreground emission (the “wedge”). This region likely contains much of the cosmological signal, and accessing it will require measurement of per-antenna beam patterns. However, unmodeled beam-forming errors do not contaminate the Fourier space region expected to be free of foreground contamination (the “EOR window”), showing that foreground avoidance remains a viable strategy.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of first mirror heating for the collective Thomson scattering diagnostic in ITER

Collective Thomson scattering (CTS) has the capabilities to measure phase space densities of fast ion populations in ITER resolved in configuration space, in velocity space, and in time. In the CTS system proposed for ITER, probing radiation at 60 GHz generated by two 1 MW gyrotrons is scattered in the plasma and collected by arrays of receivers. The transmission lines from the gyrotrons to the plasma and from the plasma to the receivers contain several quasioptical mirrors among other components. These are designed to produce astigmatic beam patterns in the plasma where the beam shapes will have a direct impact on the signal strength of the diagnostic, the spatial resolution, and the robustness of probe and receiver beam overlap against density excursions. The first mirror has a line of sight to the plasma and is thus exposed to severe neutron streaming. The present neutronics and thermomechanical modeling of a first mirror on the high field side indicates that the mirror curvature may warp due to heating. This may alter the beam quality, and therefore, thermal effects have to be accounted for during the design of the mirror. The modeling further demonstrates that thin mirrors are superior to thick mirrors from a thermomechanical point of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIVE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE OBSERVATIONS: BEAM MAPS AND WINDOW FUNCTIONS

Cosmology and other scientific results from the Wilkinson Microwave Anisotropy Probe (WMAP) mission require an accurate knowledge of the beam patterns in flight. While the degree of beam knowledge for the WMAP one-year and three-year results was unprecedented for a CMB experiment, we have significantly improved the beam determination as part of the five-year data release. Physical optics fits are done on both the A and the B sides for the first time. The cutoff scale of the fitted distortions on the primary mirror is reduced by a factor of {approx}2 from previous analyses. These changes enable an improvement in the hybridization of Jupiter data with beam models, which is optimized with respect to error in the main beam solid angle. An increase in main-beam solid angle of {approx}1% is found for the V2 and W1-W4 differencing assemblies. Although the five-year results are statistically consistent with previous ones, the errors in the five-year beam transfer functions are reduced by a factor of {approx}2 as compared to the three-year analysis. We present radiometry of the planet Jupiter as a test of the beam consistency and as a calibration standard; for an individual differencing assembly, errors in the measured disk temperature are {approx}0.5%.

79 ASTRONOMY AND ASTROPHYSICS↗

Systems, devices, and methods for authenticating millimeter wave devices

Systems, devices, and methods are described for millimeter wave device authentication. A system may include one or more access points. Each access point of the one or more access points is configured to extract, from one or more beam patterns generated via a client device, a beam feature associated with the client device. Each access point may also be configured to transmit the beam feature. The system may also include a server communicatively coupled to the one or more access points and including a database for storing known beam features. The server may be configured to receive the beam feature associated with the client device from at least one access point of the one or more access points. Also, the server may be configured to authenticate the client device in response to the received beam feature matching a known beam feature stored in the at least one database.

Bhuyan, Arupjyoti↗

Piezoelectric transducer design for a miniaturized injectable acoustic transmitter

Acoustic telemetry has been an important tool in the last 20 years for studying fish survival and migration behaviors during and after dam passage. This technology uses implantable acoustic transmitters as tags to three-dimensionally track the movement of fish. However, the relatively large weights and sizes of commercially available transmitters limit the populations of fish that could be studied. The surgical implantation procedures required may also injure fish and also incur a significant amount of labor. Therefore, a smaller, lighter, and injectable tag was needed, and similar or better acoustic performance and service life over that provided by existing commercial tags was desired. To develop such a small transmitter, a number of technical challenges, including design optimization of the piezoelectric transducer, needed to be overcome. The goal of our efforts to optimize the transducer focused on improving the average source level in the 180° range in which the transmitter was facing the receiving hydrophone, so as to increase the transmitter’s detection probability. This paper reports the techniques that were explored and developed to achieve this goal. We found that a novel off-center tube transducer improved the average source level of the front half of the transducer by 1.5 dB. An acoustic reflector attached to the back of the transducer also improved the source level by 3 dB when the transducer was pointed toward the receiving hydrophone, although the source level on the sides of the transducer was reduced. We found that too small a gap between the transducer and the component placed behind it resulted in distortion of the beam pattern. To overcome that issue, we connected a tuning inductor in series with the transducer to help optimize the source level. Furthermore, the findings and techniques developed in this work contributed to the successful development and implementation of a new injectable transmitter.

42 ENGINEERING↗