Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Does one need to polish electrodes in an eight pattern? Automation provides the answer

Automation of electrochemical measurements can accelerate the discovery of new electroactive materials. One of the hurdles to automated electrochemical measurement is the pretreatment of electrodes because mechanical polishing is usually conducted manually. Here we investigate the automation of electrochemical measurements using a robotic arm. We demonstrate automated mechanical polishing using a station with a moving polishing pad and evaluate the effect of different polishing patterns. Our automatic method improved the corroded electrodes, and we found the effect of pattern was not significant, which diverges from the current common belief amongst practitioners that a figure eight pattern is best for pretreatment. This research is a step toward automating electrochemistry experiments without human intervention.

Yoshikawa, Naruki [University of Toronto, ON (Cana↗

Modelling and Experimental Validation of Improved Performance of Lithium-Ion Batteries Having Thick Electrodes with Laser-Ablated Micro-Structures

For widespread adoption of electric vehicles, lithium-ion batteries (LiBs) need to achieve energy densities of >275 Wh/kg, cost less than $100/Wh, and charge to more than 80% capacity within 15 minutes. Increasing the battery electrode thicknesses is one way to increase cell energy densities while also saving on cell manufacturing cost by increasing the ratio of electrode active material to inactive material within each cell. However, increased electrode loading is often accompanied by decreased Li+-ion diffusion across the full thick electrodes. This leads to significant cell polarization that prevents full capacity utilization and accelerates cell degradation, especially at fast charging/discharging rates. The introduction of secondary pore networks in thick battery electrodes alleviates some of the trade-offs between energy and power performance. These microstructures provide low tortuosity pathways for facile Li+-ion diffusion deep into the thick electrodes, diminishing detrimental concentration gradients within the cell. Ultrafast-pulsed laser ablation is a promising method to introduce micro pores or channels in thick battery electrodes as it allows for precise control of pattern geometries, results in minimal damage to the electrode and can be introduced into existing roll-to-roll electrode manufacturing lines. Herein, the limitations of thick planer electrodes and the advanced predictive models to identify optimal electrode patterns for improved cycling performance will be presented. The impact of electrode laser patterning to create secondary pore networks also will be discussed. Materials characterization techniques (SEM-EDS, XRD) were used to explore the affect ultrafast laser ablation had on the electrode materials’ morphology and structure. The improvements in the patterned electrodes’ electrochemical cycling performances and degrees of wetting will be compared to a pristine baseline case. Finally, the discrepancies between experimentally obtained data and model predictions will be explained.

DIRECT ENERGY CONVERSION,ENERGY STORAGE↗

Manufacturing Water‐Based Low‐Tortuosity Electrodes for Fast‐Charge through Pattern Integrated Stamping

Achieving high energy density and fast charging of lithium‐ion batteries can accelerate the promotion of electric vehicles. However, the increased mass loading causes poor charge transfer, impedes the electrochemical reaction kinetics, and limits the battery charging rate. Herein, this work demonstrated a novel pattern integrated stamping process for creating channels in the electrode, which benefits ion transport and increases the rate performance of the electrode. Meanwhile, the pressure applied during the stamping process improved the contact between electrode and current collector and also enhanced the mechanical stability of the electrode. Compared to the conventional bar‐coated electrode with the same thickness of 155 μm (delivered a discharge capacity of 16 mAh g −1 at the rate of 3 C), the stamped low‐tortuosity LiFePO 4 electrode delivered 101 mAh g −1 capacity. Additionally, water was employed as a solvent in this study. Owing to its eco‐friendliness, high scalability, and minimal waste generation, this novel stamping technique inspire a new method for the industrial‐level efficient roll to roll fabrication of fast‐charge electrodes.

25 ENERGY STORAGE↗

Enabling fast-charging of lithium-ion batteries through printed electrodes

It has been well recognized that introducing secondary porous networks (SPNs) into the electrodes can effectively improve the electrochemical performance of lithium-ion batteries (LIBs), especially under fast-charging operations. However, the process complexity and high cost limit the commercial success of advanced electrodes with SPNs. To address this issue, we developed a facile screen-printing process to produce structured graphite electrodes with SPNs. The experimental results demonstrated that, by tuning the diameter and center-to-center (C2C) distance of emulsion dots on the stencil screen, the pore diameters and C2C pore distances of SPNs in screenprinted electrodes can be precisely controlled in the range of 100 mu m to 1 mm and 100 mu m to 3 mm respectively. In addition, the SPNs with hexagonal and square-shape pore alignments have also been imprinted onto the electrode coatings through adjusting the patterns of screen stencils. Used as anodes, the printed graphite electrodes demonstrated significantly reduced overpotential and voltage fluctuation under fast-charging operations from 2C to 6C. Coupled with LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) cathodes, the full cells with printed graphite anodes exhibited an unprecedently stable performance with almost no capacity decay up to 170 cycles when charged to 80 % SOC at 2C. Observations from electron microscopy showed plated lithium undetectable at the surface of printed graphite electrodes after numerous cycles. The electrochemical analysis on the voltage evolution during the cell rest period indicated the significantly delayed onset of lithium plating in the presence of printed graphite electrodes. In conclusion, all these results suggest that the significantly improved cell performance is associated with the shortened Li-ion diffusion distance, reduced polarization and suppressed Li plating in the printed electrodes with patterned SPNs.

25 ENERGY STORAGE↗

Laser ablation of high-loading Li-ion battery electrodes improves accessible capacity and cycle life for Behind-the-Meter Storage

Adoption of Behind-the-Meter Storage (BTMS) requires design of batteries that enable high safety, long cycle life, and low cost at the system level. Pairing Li 4 Ti 5 O 12 (LTO) with LiMn 2 O 4 (LMO) achieves targets related to safety and cycle life, but these materials' low energy densities contribute to higher cost at the system scale. Increasing electrode loading is a simple approach to improve energy density, but comes with a trade-off in electrode utilization due to long, tortuous Li + diffusion pathways. Here, laser ablation is used to microstructure (pattern) high-loading electrodes to enhance electrode performance through improved Li + diffusion pathways. Four cell types, comprising combinations of standard or patterned anode and cathode, were prepared to evaluate the effects of laser ablation at each electrode. A rate test shows that patterning electrodes enhances active material utilization at ≳1C rates. Patterning the cathode yields the most benefit, as cells with a patterned cathode demonstrate a ~20% higher accessible capacity than those without at 1.4C. Additionally, 1C capacity retention of cells with patterned cathode (91% through 3000 cycles) is significantly improved over cells with only the anode patterned (64%) and non-patterned electrodes (50%). Characterization of post-mortem cells before and after refreshing their electrolyte suggests that 1C capacity retention is improved by mitigation of electrode "dry-out". We hypothesize that the microstructure acts as a reservoir of additional electrolyte, or a path for gas to escape, so that active material remains wetted throughout long-term cycling, and/or the microstructure may reduce localized, gas-forming overpotentials in the high-loading electrode.

25 ENERGY STORAGE↗

One–Step Fabrication of Nanocrystalline Nanonetwork SnO 2 Gas Sensors by Integrated Multilaser Processing

An integrated multilaser process is developed to fabricate nanocrystalline nanonetwork SnO 2 gas sensors in one integrated procedure, which combines electrodes fabrication, nanomaterials deposition, and postannealing. Interdigit electrodes are fabricated on an Au-coated fused silica substrate using a picosecond (ps) laser, which ablates the Au coating from the back of the substrate to pattern the electrodes. A novel transmitted Ps laser deposition (TPLD) process is designed to deposit SnO 2 nanonetwork on the interdigit electrodes with precise deposition area control under a close target-to-substrate distance. The obtained SnO 2 nanonetwork is in situ postannealed by a CO 2 laser to improve the crystallinity, while the nano morphology and grain size keep intact. To investigate the morphology and formation process of the nanonetwork, the microstructure of the laser-deposited SnO 2 layer is characterized. As a result, the crystallization control of CO 2 laser annealing is investigated through analyzing the Raman spectrum, X-ray diffraction (XRD) patterns, and lattice structures of the samples. By exposed to H 2 atmosphere, the fabricated gas sensor is demonstrated for H 2 monitoring.

08 HYDROGEN↗

Topology optimization for the design of porous electrodes

Porous electrodes are an integral part of many electrochemical devices since they have high porosity to maximize electrochemical transport and high surface area to maximize activity. Traditional porous electrode materials are typically homogeneous, stochastic collections of small-scale particles and offer few opportunities to engineer higher performance. Fortunately, recent breakthroughs in advanced and additive manufacturing are yielding new methods to structure and pattern porous electrodes across length scales. These architected electrodes are emerging as a promising new technology to continue to drive improvement; however, it is still unclear which structures to employ and few tools are available to guide their design. Here we address this gap by applying topology optimization to the design of porous electrodes. We demonstrate our framework on two applications: a porous electrode driving a steady Faradaic reaction and a transiently operated electrode in a supercapacitor. We present computationally designed electrodes that minimize energy losses in a half-cell. For low-conductivity materials, the optimization algorithm creates electrode designs with a hierarchy of length scales. Further, the designed electrodes are found to outperform undesigned, homogeneous electrodes. Finally, we present three-dimensional porous electrode designs. We thus establish a topology optimization framework for designing porous electrodes.

25 ENERGY STORAGE↗

Multiphysics Modeling of Electrode Dissolution under Hydrodynamic Conditions in Low Conductivity Water

Efficient plug-flow electrochemical reactors are characterized by their ability to effectively convert species with significant ionic strength and/or with the assistance of a well-behaved electrolyte. Because of the classic electroconductivity requirement, electrochemical reactors are not particularly attractive options for applications with low-conductivity conditions, especially for low-pressure feeds. However, these reactors can still find application in dedicated processes such as ultra-clean water conditioning and biological-coupled separation systems. Consequently, a multi-physics model was developed using COMSOL Multiphysics to characterize different reactor-design conditions based on the Tertiary Current Distribution which accounts for the effects of expected variations in electrolyte composition and ionic strength on the electrochemical process, as well as solution resistance and electrode kinetics. The modelling framework presented here employs single-phase laminar fluid flow, the Nernst-Planck equation, the water-based electroneutrality condition, and concentration-dependent overpotentials. This investigation particularly explores the electrolysis process of “anodic dissolution,” in which elemental species dissociate from the solid matrix of the electrode and enter the liquid phase of the electrolyte as soluble ions. The reactor configuration of interest has a rectangular parallel-electrode design and is operated galvanostatically. A series of parametric studies are carried out to inspect the response of the system when hydrodynamic, kinetic, and geometric conditions are changed. The parametric sweep resulted in variable effluent concentrations and system voltage, which reveal underlaying optimization patterns for electrode dissolution in low conductivity water.

Multiphysics↗

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strain-Based Chemiresistive Polymer-Coated Graphene Vapor Sensors

Suspended chemiresistive graphene sensors have been fabricated using well-established nanofabrication techniques to generate sensors that are highly sensitive to pyridine and with excellent discrimination between polar and nonpolar analytes. When coated with a polymer surface layer and suspended on 3-D patterned glass electrodes, a hybrid combination of polymer and graphene yields chemiresistive vapor sensors. Expansion and contraction of the polymer layer produces strain on the suspended graphene (Gr). Hence, when organic vapors permeate into the polymer layer, the high gauge factor of the graphene induces substantial electrical resistive changes as folds and creases are induced in the graphene. The hybrid suspended polymer/Gr sensor exhibits substantial responses to polar organic vapors, especially pyridine, while also exhibiting reversibility and increased discrimination between polar and nonpolar analytes compared to previous approaches. This sensor design also allows for potential tunability in the types of polymers used for the reactive surface layer, allowing for use in a variety of potential applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular beam epitaxy of the magnetic Kagome metal FeSn on LaAlO 3 (111)

Materials with Kagome layers are expected to give rise to rich physics arising from band structures with topological properties, spin liquid behavior, and the formation of Skyrmions. Until now, most work on Kagome materials has been performed on bulk samples due to difficulties in thin film synthesis. Here, by using molecular beam epitaxy, layered Kagome-structured FeSn films are synthesized on the (111) oriented LaAlO3 substrate. Both in situ and ex situ characterizations indicate that these films are highly crystalline and c-axis oriented, with atomically smooth surfaces. The films grow as disconnected islands, with lateral dimensions on the micron meter scale. By patterning Pt electrodes using a focused electron beam, the longitudinal and transverse resistance of single islands have been measured in magnetic fields. Our work opens a pathway for exploring mesoscale transport properties in thin films of Kagome materials and related devices.

36 MATERIALS SCIENCE↗

Glove-based sensors for multimodal monitoring of natural sweat

Sweat sensors targeting exercise or chemically induced sweat have shown promise for noninvasive health monitoring. Natural thermoregulatory sweat is an attractive alternative as it can be accessed during routine and sedentary activity without impeding user lifestyles and potentially preserves correlations between sweat and blood biomarkers. We present simple glove-based sensors to accumulate natural sweat with minimal evaporation, capitalizing on high sweat gland densities to collect hundreds of microliters in just 30 min without active sweat stimulation. Sensing electrodes are patterned on nitrile gloves and finger cots for in situ detection of diverse biomarkers, including electrolytes and xenobiotics, and multiple gloves or cots are worn in sequence to track overarching analyte dynamics. Direct integration of sensors into gloves represents a simple and low-overhead scheme for natural sweat analysis, enabling sweat-based physiological monitoring to become practical and routine without requiring highly complex or miniaturized components for analyte collection and signal transduction.

42 ENGINEERING↗

Temporal and spatial tuning of optical constants in praseodymium doped ceria by electrochemical means

Abstract Temporal and spatial tuning of the refractive index of optical thin films is desired for flat optics applications. The redistribution of mobile ions in mixed ionic-electronic conductors (MIEC) has been demonstrated to serve as a viable means for achieving optical tuning down to the nanoscale. Here we studied the dynamic range of the optical tuning achievable in the refractive index, in the MIEC oxide – Pr x Ce 1− x O 2− δ (PCO), for x = 0.1, 0.2 and 0.4, at 500 °C, by in-situ spectrophotometry. Significant increases in the modulation of both the imaginary and real optical constants in the visible and the adjacent spectra were obtained for increased doping levels. Device employing an electrochemical titration method was implemented to modulate the oxygen concentration, and thereby the optical transmission of PCO. Incorporation of a patterned top electrode allowed for the demonstration of spatial control of PCO thin film properties by in-situ video imaging of the optical switching process. The electrochemically induced optical state is shown to remain non-volatile upon quenching the device to room temperature under applied bias.

36 MATERIALS SCIENCE↗

Science Driven Discovery of Nanoparticle Photocatalysts

Photocatalytic water splitting using suspensions of nanoparticle photocatalysts is a promising route to economically sustainable production of green hydrogen. The principal challenge is to develop photocatalysts with overall solar-to-hydrogen conversion efficiency that exceeds 10 percent. In this project we have developed a new platform for investigating candidate materials for photocatalytic water splitting. Our platform consists of patterned Au electrodes and a Ag/AgCl reference electrode on an insulating substrate onto which we disperse nanoparticle photocatalysts. We then cover the substrate with a thin layer of ionogel containing a protic ionic liquid that dissolves water from the ambient. Using this platform we have demonstrated photoelectrochemical activity mapping for single and small clusters of BiVO 4 nanoparticle photocatalysts and correlated these results to their Raman and photoluminescence spectra. The preliminary results suggest a strong correlation for low efficiency nanoparticles, followed by saturation for those with higher activities, indicating that interface reaction or electrolyte transport become the limiting factor. We anticipate that further application of this platform to investigation of candidate photocatalyst materials will provide useful insights into the mechanisms that limit their performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Cathode Cooling in Three-Dimensional Simulations of an Atmospheric Pressure Glow Discharge

The Atmospheric Pressure Glow Discharge (APGD) is a relatively simple and versatile plasma source used in a wide range of applications. Active cooling of the cathode can effectively mitigate instabilities, leading to glow-to-arc transitions. This study investigates the effect of varying the degree of cathode cooling in APGD with a planar cathode in helium. The plasma flow model incorporates mass conservation, chemical species transport, momentum conservation, conservation of thermal energy of heavy species and of electrons, and electrostatics. The model is applied to time-dependent simulations through a three-dimensional computational domain describing the whole discharge, without geometric symmetry or steady-state assumptions. Simulations of an experimentally characterized APGD explore the effects of electric current and cathode cooling—ranging from thermally insulated to extreme convective cooling. Results show the formation of an annular region with high electric field over the cathode surface under conditions of high current and low cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An all-silicon single-wafer micro-g accelerometer with a combined surface and bulk micromachining process

This paper reports an all-silicon fully symmetrical z-axis micro-g accelerometer that is fabricated on a single-silicon wafer using a combined surface and bulk fabrication process. The microaccelerometer has high device sensitivity, low noise, and low/controllable damping that are the key factors for attaining micro g and sub-micro g resolution in capacitive accelerometers. The microfabrication process produces a large proof mass by using the whole wafer thickness and a large sense capacitance by utilizing a thin sacrificial layer. The sense/feedback electrodes are formed by a deposited 2-3 microns polysilicon film with embedded 25-35 microns-thick vertical stiffeners. These electrodes, while thin, are made very stiff by the thick embedded stiffeners so that force rebalancing of the proof mass becomes possible. The polysilicon electrodes are patterned to create damping holes. The microaccelerometers are batch-fabricated, packaged, and tested successfully. A device with a 2-mm x 1-mm proof mass and a full bridge support has a measured sensitivity of 2 pF/g. The measured sensitivity of a 4-mm x 1-mm accelerometer with a cantilever support is 19.4 pF/g. The calculated noise floor of these devices at atmosphere are 0.23 micro g/sqrt(Hz) and 0.16 micro g/sqrt(Hz), respectively.

Non-NASA Center↗

Electrical Capacitance Volume Tomography with High-Contrast Dielectrics

The Electrical Capacitance Volume Tomography (ECVT) system has been designed to complement the tools created to sense the presence of water in nonconductive spacecraft materials, by helping to not only find the approximate location of moisture but also its quantity and depth. The ECVT system has been created for use with a new image reconstruction algorithm capable of imaging high-contrast dielectric distributions. Rather than relying solely on mutual capacitance readings as is done in traditional electrical capacitance tomography applications, this method reconstructs high-resolution images using only the self-capacitance measurements. The image reconstruction method assumes that the material under inspection consists of a binary dielectric distribution, with either a high relative dielectric value representing the water or a low dielectric value for the background material. By constraining the unknown dielectric material to one of two values, the inverse math problem that must be solved to generate the image is no longer ill-determined. The image resolution becomes limited only by the accuracy and resolution of the measurement circuitry. Images were reconstructed using this method with both synthetic and real data acquired using an aluminum structure inserted at different positions within the sensing region. The cuboid geometry of the system has two parallel planes of 16 conductors arranged in a 4 4 pattern. The electrode geometry consists of parallel planes of copper conductors, connected through custom-built switch electronics, to a commercially available capacitance to digital converter. The figure shows two 4 4 arrays of electrodes milled from square sections of copper-clad circuit-board material and mounted on two pieces of glass-filled plastic backing, which were cut to approximately square shapes, 10 cm on a side. Each electrode is placed on 2.0-cm centers. The parallel arrays were mounted with the electrode arrays approximately 3 cm apart. The open ends were surrounded by a metal guard to reduce the sensitivity of the electrodes to outside interference and to help maintain the spacing between the arrays. Other uses for this innovation potentially include quantifying the amount of commodity remaining in the fuel and oxidizer tanks while on-orbit without having to fire spacecraft engines. Another orbit application is moisture sensing in plant-growth experiments because microgravity causes moisture in soil to distribute itself in unusual ways. At the moment, the hardware and image reconstruction technique may only be of interest to people involved in nondestructive evaluation. The reconstructed image takes almost a full week to reproduce with existing computer power. However, because computer power and speeds follows Moore s Law, execution times are likely to become acceptable within the next five to eight years. The code was written in Mathematica for dedicated use with the ECVT system. In its present form, it is not suitable to be used directly as a consumer product. However, the code could be likely improved by rewriting it in a compiled language such as C or Fortran.

Nurge, Mark↗