Search NASA⌕ Search

SEARCH · Search NASA

Results for “peak load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Synthetic residential load models for smart city energy management simulations

The ability to control tens of thousands of residential electricity customers in a coordinated manner has the potential to enact system-wide electric load changes, such as reduce congestion and peak demand, among other benefits. To quantify the potential benefits of demand-side management and other power system simulation studies (e.g. home energy management, large-scale residential demand response), synthetic load datasets that accurately characterize the system load are required. This study designs a combined top-down and bottom-up approach for modelling individual residential customers and their individual electric assets, each possessing their own characteristics, using time-varying queueing models. The aggregation of all customer loads created by the queueing models represents a known city-sized load curve to be used in simulation studies. The three presented residential queueing load models use only publicly available data. An open-source Python tool to allow researchers to generate residential load data for their studies is also provided. The simulation results presented consider the ComEd region (utility company from Chicago, IL) and demonstrate the characteristics of the three proposed residential queueing load models, the impact of the choice of model parameters, and scalability performance of the Python tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermally anisotropic composites for thermal management in building environments

An improved system for thermal management is provided. The system includes thermally anisotropic composites coupled with a thermal loop to re-direct, reduce, and shape heat flows through a building envelope, having the potential to (1) significantly reduce envelope-generated heating and cooling loads and (2) provide grid services such as decreasing peak loads and shaping energy use. In one embodiment, the thermal management system includes an anisotropic composite that consists of alternating layers of thermal insulation and thermally conductive materials that are immediately adjacent to each other, including polyisocyanurate foam boards and aluminum sheets. The thermal management system also includes a thermal loop along the long edge or the entire the perimeter of the anisotropic composite, the thermal loop having dynamically controlled or floating temperature that is maintained at lower than an outdoor ambient temperature (for cooling). An interior wall structure is inwardly adjacent to the anisotropic composite.

Shrestha, Som S.↗

Design Considerations of a Coordinative Demand Charge Mitigation Strategy

This paper presents a coordinative demand charge mitigation (DCM) strategy for reducing electricity consumption during system peak periods. Available DCM resources include batteries, diesel generators, controllable loads, and conservation voltage reduction. All resources are directly controlled by load serving entities. A mixed integer linear programming based energy management algorithm is developed to optimally coordinate of DCM resources considering the load payback effect. To better capture system peak periods, two different kinds of load forecast are used: the day-ahead load forecast and the peak-hour probability forecast. Five DCM strategies are compared for reconciling the discrepancy between the two forecasting results. The DCM strategies are tested using actual utility data. Simulation results show that the proposed algorithm can effectively mitigate the demand charge while preventing the system peak from being shifted to the payback hours. We also identify the diminishing return effect, which can help load serving entities optimize the size of their DCM resources.

Hu, Rongxing↗

Determining and Unlocking Untapped Demand-Side Management Potential in South Africa: Demand Response at the Grid Edge

The National Renewable Energy Laboratory (NREL), funded through the Climate Technology and Change Network (CTCN), has provided technical assistance to key energy sector entities in South Africa to examine untapped demand-side management potential. NREL partnered with the Council for Scientific and Industrial Research (CSIR) and included key South Africa stakeholders: Eskom, the South African National Energy Development Institute (SANEDI), and the Department of Mineral and Resources and Energy (DMRE), including the CTCN National Designated Entity (NDE), the Department of Science and Innovation (DSI). South Africa is currently experiencing an energy crisis with extensive load shedding. While the load shedding crisis in South Africa is a supply side problem, demand-side management provides opportunities to achieve energy efficiency and to reduce peak demand. DSM also has huge potential to help alleviate load shedding, which is a last resort form of DSM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

DERMS-RT (Distributed Energy Resource Management Solution using Real-Time Optimization) [SWR-20-46]

DERMS-RT provides a distributed energy resource management solution using real-time optimization to control different types of distributed energy resources (DERs) — such as rooftop PVs, battery energy storage systems, HVAC loads, electric water heater loads, and EV charging loads, and use these DERs to provide distribution voltage regulation and peak demand management services. The control approach implemented by DERM-RT is developed based on the real-time optimal power flow and distributed control previously developed by NREL researchers. The software codes are designed to provide modular DER management solution that can be easily applied to control heterogeneous DERs in distribution grids in coordination with centralized utility management systems. Also, DERMS-RT provides application programming interface (API) to extract useful grid model information from an open-source power system simulation software, use the information to solve the optimization problem, and apply the optimal set-points to the controlled DERs. In this way, DERMS-RT provides a plug-and-play function for implementing the real-time DER control on different utility system models, and it can be used as a simulation testbed to demonstrate the impact of real-time DER optimization on improving grid operations.

Ding, Fei↗

Communications Reliability for Vehicle Grid Integration

Electric Vehicles (EVs) adoption rate has been steadily increasing in the US leading to a growing number of charging stations including faster DC (Direct Current) chargers and slower Level 1 and Level 2 AC (Alternating Current) chargers. This increase in demand for electricity is further exacerbated by recent developments in Artificial Intelligence (AI) technology, advanced manufacturing, and digitization. These factors will require electric utilities to upgrade their infrastructure to keep up with the increasing electrical demand (especially during peak hours). An easy way to counteract the need for these upgrades is to shift a major chunk of active charge sessions (durations where there is energy transfer from charger to EV's propulsion battery) to off-peak hours thereby flattening the load curve and making the infrastructure more resilient. This concept is known as Smart Charge Management (SCM). EV owners also benefit from SCM since it lowers their charging costs and consequently their transportation costs by prioritizing charging during off-peak hours. SCM takes advantage of EV's capability to act as a controllable load or DER (Distributed Energy Resource). This report summarizes the reliability analysis performed on the communication required for two of these SCM use-cases. This analysis only focuses on SCM strategies for unidirectional charging (energy transfer from EVSE to EV or V1G) and not bidirectional charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nepal Himalaya offers considerable potential for pumped storage hydropower

There is a pressing need for a transition from fossil fuel to renewable energy to meet the increasing energy demands and reduce greenhouse gas emissions. The Himalayan region, with its unique topography and abundant water resources, offers substantial renewable energy potential, particularly through hydropower generation. However, the current exploitation rate is low owing to the predominance of run-of-river hydropower systems to support the power system. The utility-scale storage facility is crucial in the load scenario of an integrated power system to manage diurnal variation, peak demand, and penetration of intermittent energy sources. In this study, we assess the potential of pumped storage hydropower across Nepal, a central Himalayan country, under multiple configurations by pairing lakes, rivers, and available flat terrains. We then identify technically feasible pairs from those of potential locations. Infrastructural, environmental, operational, and other technical constraints govern the choice of feasible locations. Here, we show that 42% of the theoretical potential of 3000 GWh is technically feasible. We find the flat land-to-river configuration more promising than other configurations. Our findings provide insight into the potential of pumped storage hydropower and are of practical importance in planning sustainable power systems in the Himalayas and beyond.

13 HYDRO ENERGY↗

EVs@Scale Next-Gen Profiles - Fleet Utilization 2024

As part of the U.S. Department of Energy’s EVs@Scale initiative, the Next-Gen Profiles (NGP) project provides a comprehensive, data-driven analysis of electric vehicle (EV) and electric vehicle supply equipment (EVSE) operations across real-world fleet deployments. This paper presents findings from the NGP’s Fleet Utilization study, which investigates operational behavior and asset usage across seventeen EV fleets and two EVSE fleets, encompassing a wide range of vehicle types and use cases. Data collected from diverse sources—varying in format and temporal resolution—are first reformatted into a unified structure. From this harmonized dataset, a suite of rigorously defined performance metrics is calculated at an hourly cadence, enabling consistent cross-comparison of charging, routing, and other key operational behaviors. Amid rapidly increasing EV adoption and growing demands for energy-efficient fleet operations, the analysis reveals clear utilization trends—including diurnal and weekly activity cycles, differences in short versus long charging session dependencies, and route-specific energy usage patterns. These findings highlight the need for tailored infrastructure strategies and the deployment of advanced energy management systems, such as Distributed Energy Resource Management Systems (DERMS) and Site Energy Management Systems (SEMS), which can optimize charging schedules and mitigate peak loads. By leveraging anonymized, harmonized datasets and standardized metrics, this study offers critical insights into fleet behavior and performance, providing a foundation to improve operational efficiency, reduce costs, and enable the scalable deployment of electrified transportation.

Wells, Landon↗

Bridging Cloud and Edge Computing at NREL Using CONNECT: Cloud Optimized Networking for Next-Gen Edge Computing Technologies [Slides]

CONNECT is an innovative on-premise hardware and software solution that integrates edge and cloud computing infrastructure at NREL. Built on the AWS Greengrass middleware and leveraging the MQTT protocol, CONNECT enables real-time data streaming from IoT devices and gateways to both cloud and local services, empowering researchers to rapidly capture, analyze, and act upon edge-generated data while leveraging cloud capabilities. The platform addresses research infrastructure challenges by providing a pre-approved platform which is already configured with the correct networking and cybersecurity baselines thus eliminating procurement delays and enabling on-demand availability. CONNECT's hybrid architecture efficiently manages burstable workloads, allowing research teams to dynamically scale computational capacity, handle peak data loads, and reduce operational bottlenecks. Advanced capabilities include built-in GPU support for executing machine learning models which enables low-latency inference at the edge from models trained in the cloud. This architecture supports real-time analytics and filtering, providing a mechanism to allow only transmitting and processing high-value data. Cloud-based configuration management permits engineers to manage on-premise systems remotely, optimizing operational efficiency. By bridging edge and cloud computing, CONNECT provides NREL researchers with a flexible, scalable platform that accelerates scientific discovery while maintaining robust security and performance standards.

97 MATHEMATICS AND COMPUTING↗

A Framework to Evaluate the Grid Impacts of EV Fleet Charging Solutions

Growing Electric vehicle (EV) adoption in residential and commercial applications is driving the need for the charging infrastructures required to fulfill the charging needs. The resulting increase in demand for electric power will add a significant load to the electric grid, which could negatively impact the grid operation. EVs are power electronic loads and draw harmonic currents which can lead to a host of power quality issues. Therefore, it is crucial to assess the grid impacts and management of EV charging loads to ensure the reliable operation of the electric grid. In this paper, we develop a framework to help determine power-quality impacts given an EV charging schedule on the system. We compare the performance of unmanaged and managed charging solutions on factors like voltage drop, flicker, harmonic distortion and the peak site load - based on the EV depot in Hazelwood school district. The results allow insights into operation and site design of EV depots.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Performance and Implementation Requirements for Residential EV Smart Charge Management Strategies

As the electrification of transportation expands, electric vehicle (EV) charging as residential loads will continue to grow. Residential EV charging has the potential to increase feeder peak loads and decrease voltage quality. As a result of this growing energy demand driven by EV, utilities may employ the use of smart charge management (SCM) controls to modify charging load profiles and mitigate these grid impacts. It is important that utilities understand both the potential benefits-as well as possible implementation challenges-before considering this technology as a solution to managing growing EV loads. In order for an SCM strategy to be an effective solution, the potential benefits must outweigh the implementation challenges. This study establishes and tests a novel framework to assess the implementation requirements of different SCM controls. It identifies a range of requirements specific to various SCM controls and implementation approaches to compare the relative challenges associated with the deployment of each. When paired with analysis on the effectiveness of the ability of each control to mitigate grid impacts from EV charging, this assessment is critical in comparing the value potential of different SCM controls.

ADVANCED PROPULSION SYSTEMS↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Charge Management for an Inductively Charged On-Demand Battery-Electric Shuttle Service with High Penetration of Renewable Energy

This paper presents a charge management control strategy for an on-demand battery-electric shuttle van operating at the National Renewable Energy Laboratory (NREL) campus and supported by day-time inductive charging at the vehicle's waiting spot. A new control algorithm has been proposed for reducing the demand charge costs incurred from wireless charging of the on-demand shuttle. A custom controller has been developed to monitor the shuttle, wireless charger, renewable energy generation, and various loads at NREL's campus, and regulate charging behavior for demand response. The intermittent renewable generation and sporadic operation of the on-demand shuttle service contribute to a high level of uncertainty in expected campus load profile, which must be carefully managed. The control algorithm predicts energy profile to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller has been designed and optimized using a Simulink model for the entire system. Next, it has been implemented and tested in real-time on the NREL campus. Two primary vehicle-use cases, charge sustaining and charge depletion operation, are tested under different load profiles and drive cycles to assess the controller's effectiveness at reducing peak demand and therefore demand charges. The proposed controller showed robust performance under different driving scenarios with high correlation between simulated and experimental data. The results showed that proper demand response can be achieved with an average of 94% reduction of charging loads during peak demand events.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Advanced Materials and Additive Manufacturing for Phase Change Thermal Energy Storage and Management: A Review

Abstract Phase change materials (PCMs) can enhance the performance of energy systems by time shifting or reducing peak thermal loads. The effectiveness of a PCM is defined by its energy and power density—the total available storage capacity (kWh m −3 ) and how fast it can be accessed (kW m −3 ). These are influenced by both material properties as well as geometry of the energy systems; however, prior efforts have primarily focused on improving material properties, namely, maximizing latent heat of fusion and increasing thermal conductivity. The latter is often at the expense of the former. Advanced manufacturing techniques hold tremendous potential to enable co‐optimization of material properties and device geometry, while potentially reducing material waste and manufacturing time. There is an emerging body of research focused on additive manufacturing of PCM composites and devices for thermal energy storage (TES) and thermal management. In this article, the fundamentals and applications of PCMs are reviewed and recent additive manufacturing advances in latent heat TES for both the PCM composite and associated heat exchanger are discussed. A forward‐looking perspective on the future and potential of PCM additive manufacturing for TES and thermal management is provided.

25 ENERGY STORAGE↗