Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance based design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Model-based Design Optimization to Achieve the Performance Goals (16.0 SEER/9.5 HSPF), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Usage of low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Our research in previous milestone report has shown that using heat exchangers with 5 mm diameter tubes instead of 9 mm diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants. In addition, the 5mm tube heat exchangers can lead to lower system refrigerant charge and as a result, reduce environmental impact further. However, shifting to small tube diameters requires in-depth heat exchanger design optimization to adapt to the transition to low-GWP refrigerants. In the 2nd quarter of FY21, we conducted multi-objective optimizations using Particle Swarm Optimization algorithm on a residential 5-ton air source heat pump to investigate the potential system performance improvements and material savings. 4 low-GWP refrigerants, ARM20A, ARM20B, R454A and R454C are investigated in this study. The objectives of the optimization are to minimize the heat pump material cost and to maximize the system performance simultaneously. As a result, the HXs material cost is reduced by up to 77% according to the copper and aluminum material price in current market. Under heating mode operation, the smart 4-way valve guarantees that the optimal low-GWP systems maintain or outperform the heating performance of the R410A baseline system. The model-based design optimization yields 18.3-18.9 SEER and 10.6-11.9 HSPF for optimal systems using different low-GWP refrigerants. The initial performance goals (16.0 SEER/9.5 HSPF) are achieved. Furthermore, up to 50% system refrigerant charge reduction is possible in the optimized low-GWP heat pump system using ARM20B. And 91%-95% predicted life-time direct CO 2 emission reduction is achieved by using the optimal 5mm tube low-GWP heat pumps. The significant material saving, charge reduction and direct CO 2 emission reduction help in reducing the environmental impacts of heat pump systems. The optimal heat exchangers resulting from this research can fit into the original baseline indoor and outdoor fan-coil unit. This can reduce the retrofitting effort by minimizing the change in manufacturing and installation of the heat pumps and guarantee the compatibility with end-users’ house structure. Finally, the new products can be easily accepted by manufacturers and end-users.

42 ENGINEERING↗

Graphene-Based Interconnect Exploration for Large SRAM Caches for Ultrascaled Technology Nodes

Graphene-based interconnects are considered promising replacements for traditional copper (Cu) interconnect due to their great electric properties. In this article, an interconnect-memory co- design framework is developed to efficiently optimize various graphene-based interconnect technologies. Four interconnect materials and heterogeneous design schemes are benchmarked against their traditional Cu counterparts to optimize large cache-level SRAM performance in terms of delay and energy per access, energy-delay product (EDP), and energy-delay-area product (EDAP). Here, a large design space exploration is performed based on realistic subarray design and device technology. Various interconnect- and array-level design parameters are studied to quantify the true potential of graphene-based wires for optimal memory performance.

42 ENGINEERING↗

Reliability Assessment of a Robust Design Under Uncertainty for a 3-D Flexible Wing

The paper presents reliability assessment results for the robust designs under uncertainty of a 3-D flexible wing previously reported by the authors. Reliability assessments (additional optimization problems) of the active constraints at the various probabilistic robust design points are obtained and compared with the constraint values or target constraint probabilities specified in the robust design. In addition, reliability-based sensitivity derivatives with respect to design variable mean values are also obtained and shown to agree with finite difference values. These derivatives allow one to perform reliability based design without having to obtain second-order sensitivity derivatives. However, an inner-loop optimization problem must be solved for each active constraint to find the most probable point on that constraint failure surface.

Gumbert, Clyde R.↗

Data Collection and Analysis Challenges and Mitigation Strategies for Quantitative Human Factors Research Studies in Nuclear Power Plant Modernization

The United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program Plant Modernization Pathway is conducting targeted research and development (R&D) to address aging and reliability concerns with the legacy instrumentation and control and related information systems of the U.S. LWR fleet. In this effort, the application of human factors engineering (HFE) provides an important role in ensuring new digital plant technologies enable broad innovation and business improvement with continued operational safety. Evaluation is a key activity in HFE, which often occurs iteratively through the system design lifecycle. While qualitative methods are important in collecting information of how users perform tasks through observations, quantitative methods are equally important in assessing system design based on performance. In collecting and analyzing this quantitative data, there are notable challenges in the nuclear HFE domain that may threaten the validity and reliability of the inferences made in these studies. Notable challenges include small sample size and limited resources, large error variance and small effect size, an “adding test features to losing degrees of freedom” dilemma, non-normal distribution, and heterogeneity of variance. The results in control room usability studies are often statistically non-significant, which makes it hard to interpret. This work discusses these challenges across different scientific viewpoints and provides real-world examples of these challenges in practice. Collectively, the objective of this work is to position these challenges to the larger data science community as a means of identifying future opportunities to address these issues.

99 GENERAL AND MISCELLANEOUS↗

Integrated flight/propulsion control design for a STOVL aircraft using H-infinity control design techniques

Results are presented from an application of H(infinity) control design methodology to a centralized integrated flight/propulsion control (IFPC) system design for a supersonic short take-off and vertical landing (STOVL) fighter aircraft in transition flight. The emphasis is on formulating the H(infinity) control design problem such that the resulting controller provides robustness to modeling uncertainties and model parameter variations with flight condition. Experience gained from a preliminary H(infinity)=based IFPC design study performed earlier is used as the base to formulate the robust H(infinity) control design problem and improve the previous design. Detailed evaluation results are presented for a reduced-order controller obtained from the improved H(infinity) control design showing that the control design meets the specified nominal performance objectives as well as provides stability robustness for variations in plant system dynamics with chnages in aircraft trim speed within the transition flight envelope.

Garg, Sanjay↗

Validating Performance Models for Hybrid Power Plant Control Assessment

The need for simple, but accurate performance models of wind turbine generators (WTGs), photovoltaic (PV) plants, and battery energy storage systems (BESS) for various hybrid power plant (HPP) studies motivates the present work. Particularly, the development and verification stage of HPP controls requires reduced-order models to minimize the complexity and computation effort of simulation platforms. In this paper, such models are proposed, and the most essential parts of the models are validated through field measurements. The models target power system integration studies involving active and reactive power, as well as frequency and voltage regulation where detailed models, as proposed in the standards, can be cumbersome. Field measurements of two Vestas WTGs, one 1-MW PV plant, and one 1-MW/1-MWh BESS are used for model validation. The results show that the WTG and PV performance models correctly estimate the power generation variability according to fluctuations in wind speed and solar irradiance. The BESS performance model provides satisfactory results related to grid-forming control performance and estimation of state-of-charge. The presented validation work enables using the proposed performance models for power system studies and HPP control design in all model-based design stages, that is, preliminary analysis, design, verification, and validation with a high level of confidence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Input filter design for switching regulators

A small signal average model is derived to study analytically the complex interaction among input filter, output filter and control loop, which frequently causes degradation of switch regulator performance. Analytically based design guidelines are formulated, and key design parameters are identified. It is shown that minimization of the forward transfer characteristics and the output impedance of the input filter at filter resonance are key to designing an input filter for a switching regulator with given output filter parameters and specified line and load conditions.

Lee, F. C.↗

Metallic Thermal Protection System Technology Development: Concepts, Requirements and Assessment Overview

A technology development program was conducted to evolve an earlier metallic thermal protection system (TPS) panel design, with the goals of: improving operations features, increasing adaptability (ease of attaching to a variety of tank shapes and structural concepts), and reducing weight. The resulting Adaptable Robust Metallic Operable Reusable (ARMOR) TPS system incorporates a high degree of design flexibility (allowing weight and operability to be traded and balanced) and can also be easily integrated with a large variety of tank shapes, airframe structural arrangements and airframe structure/material concepts. An initial attempt has been made to establish a set of performance based TPS design requirements. A set of general (FARtype) requirements have been proposed, focusing on defining categories that must be included for a comprehensive design. Load cases required for TPS design must reflect the full flight envelope, including a comprehensive set of limit loads, However, including additional loads. such as ascent abort trajectories, as ultimate load cases, and on-orbit debris/micro-meteoroid hypervelocity impact, as one of the discrete -source -damage load cases, will have a significant impact on system design and resulting performance, reliability and operability. Although these load cases have not been established, they are of paramount importance for reusable vehicles, and until properly included, all sizing results and assessments of reliability and operability must be considered optimistic at a minimum.

Dorsey, John T.↗

Force feedback systems in undersea manipulator applications

The manual control behavior of the operator with various levels of manipulator system complexity was studied in order to determine the relationships among control system dynamics, certain base engineering variables, controller designs and system performance. Based on the data obtained, a set of general transfer functions were prepared to provide a mathematical model of the various levels of potential force feedback fidelity as a function of force backlash present in alternate engineering designs.

Pesch, A. J.↗

Design and performance comparison of fuzzy logic based tracking controllers

Several camera tracking controllers based on fuzzy logic principles have been designed and tested in software simulation in the software technology branch at the Johnson Space Center. The fuzzy logic based controllers utilize range measurement and pixel positions from the image as input parameters and provide pan and tilt gimble rate commands as output. Two designs of the rulebase and tuning process applied to the membership functions are discussed in light of optimizing performance. Seven test cases have been designed to test the performance of the controllers for proximity operations where approaches like v-bar, fly-around and station keeping are performed. The controllers are compared in terms of responsiveness, and ability to maintain the object in the field-of-view of the camera. Advantages of the fuzzy logic approach with respect to the conventional approach have been discussed in terms of simplicity and robustness.

Lea, Robert N.↗

Design and performance of SiPM-based readout of PbF 2 crystals for high-rate, precision timing applications

Here, we have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. As a result, the performance is documented in a series of bench and beam tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orbit design and optimization based on global telecommunication performance metrics

The orbit selection of telecommunications orbiters is one of the critical design processes and should be guided by global telecom performance metrics and mission-specific constraints. In order to aid the orbit selection, we have coupled the Telecom Orbit Analysis and Simulation Tool (TOAST) with genetic optimization algorithms. As a demonstration, we have applied the developed tool to select an optimal orbit for general Mars telecommunications orbiters with the constraint of being a frozen orbit. While a typical optimization goal is to minimize tele-communications down time, several relevant performance metrics are examined: 1) area-weighted average gap time, 2) global maximum of local maximum gap time, 3) global maximum of local minimum gap time. Optimal solutions are found with each of the metrics. Common and different features among the optimal solutions as well as the advantage and disadvantage of each metric are presented. The optimal solutions are compared with several candidate orbits that were considered during the development of Mars Telecommunications Orbiter.

genetic algorithms↗

Space Launch System Base Heating Test: Sub-Scale Rocket Engine/Motor Design, Development and Performance Analysis

The Space Launch System (SLS) base heating test is broken down into two test programs: (1) Pathfinder and (2) Main Test. The Pathfinder Test Program focuses on the design, development, hot-fire test and performance analyses of the 2% sub-scale SLS core-stage and booster element propulsion systems. The core-stage propulsion system is composed of four gaseous oxygen/hydrogen RS-25D model engines and the booster element is composed of two aluminum-based model solid rocket motors (SRMs). The first section of the paper discusses the motivation and test facility specifications for the test program. The second section briefly investigates the internal flow path of the design. The third section briefly shows the performance of the model RS-25D engines and SRMs for the conducted short duration hot-fire tests. Good agreement is observed based on design prediction analysis and test data. This program is a challenging research and development effort that has not been attempted in 40+ years for a NASA vehicle.

Mehta, Manish↗

Engineering evaluation of the EQSIM simulated ground-motion database: The San Francisco Bay Area region

Ground-motion simulations for infrequent earthquake scenarios are gaining increasing interest in the engineering community for their potential to inform performance-based structural design and assessment, particularly in regions where major earthquakes are expected, but recordings from consistent historical events are not available. However, the absence of empirical data makes the evaluation of such scenarios and the interpretation of the simulation results very challenging. In this context, this paper presents the evaluation of the first EQSIM (v.1.1.0) ground-motion simulations generated for the San Francisco Bay Area (SFBA) region. The current database, which is at the first stages of development, includes eight realizations of a Hayward Fault M w 7 event. The evaluation of the simulated motions is first conducted on the average ground-motion amplitudes through comparison against the NGA-W2 GMPEs and a selected population of real records. A methodology for selecting a population of real records consistent with the simulated event is proposed. The objective of the proposed evaluation is twofold: (1) build confidence in the realistic character of the simulated motions for their use in engineering applications and (2) offer a critical physics-based interpretation of the simulation results that can help improve key features of the simulation models. To further investigate the implications of using the simulated ground motions for site-specific structural assessments, the ASCE7-16 approach is employed for the analysis of two hazard-consistent near-field sites in the SFBA. Results are discussed. Furthermore, this study offers a critical review of the EQSIM (v.1.1.0) SFBA ground-motion simulations and suggestions for improving the earthquake rupture models.

58 GEOSCIENCES↗

Towards Risk-Informed Performance-Based Emergency Planning: Review of Regulation, Guidance, and Methods

At a fundamental level, nuclear facility safety is built upon the concept of defense-in-depth (DID), which entails multiple, independent layers of protection for public health and safety. Within the DID structure, emergency preparedness (EP) is the last layer of defense and provides reasonable assurance that adequate protective measures can and will be taken in the event of a radiological emergency. Over several decades, the EP regulatory framework has evolved in response to lessons learned from actual events, experience with maintaining and testing EP capabilities, and advances in a wide range of technologies. Furthering this evolution, recent developments in risk-informed performance-based (RIPB) design and licensing approaches provide an opportunity to leverage insights regarding the attributes of the specific facility and site to inform EP.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The design of components for an advanced Rankine cycle test facility.

The design of a facility for testing components of an advanced Rankine cycle power system is summarized. The facility is a three-loop system in which lithium, potassium and NaK-78 are the working fluids of the primary, secondary and heat-rejection loops, respectively. Design bases and performance predictions for the major loop components, including the lithium heater and the potassium boiler, condenser and preheater, are outlined.

Bond, J. A.↗

Cryogenic Fluid Management Experiment (CFME) trunnion verification testing

The Cryogenic Fluid Management Experiment (CFME) was designed to characterize subcritical liquid hydrogen storage and expulsion in the low-g space environment. The CFME has now become the storage and supply tank for the Cryogenic Fluid Management Facility, which includes transfer line and receiver tanks, as well. The liquid hydrogen storage and supply vessel is supported within a vacuum jacket to two fiberglass/epoxy composite trunnions which were analyzed and designed. Analysis using the limited available data indicated the trunnion was the most fatigue critical component in the storage vessel. Before committing the complete storage tank assembly to environmental testing, an experimental assessment was performed to verify the capability of the trunnion design to withstand expected vibration and loading conditions. Three tasks were conducted to evaluate trunnion integrity. The first determined the fatigue properties of the trunnion composite laminate materials. Tests at both ambient and liquid hydrogen temperatures showed composite material fatigue properties far in excess of those expected. Next, an assessment of the adequacy of the trunnion designs was performed (based on the tested material properties).

Bailey, W. J.↗

Impact of Charge Degradation on the Life Cycle Climate Performance of a Residential Air-Conditioning System

Vapor compression systems continuously leak a small fraction of their refrigerant charge to the environment, whether during operation or servicing. As a result of the slow leak rate occurring during operation, the refrigerant charge decreases until the system is serviced and recharged. This charge degradation, after a certain limit, begins to have a detrimental effect on system capacity, energy consumption, and coefficient of performance (COP). This paper presents a literature review and a summary of previous experimental work on the effect of undercharging or charge degradation of different vapor compression systems, especially those without a receiver. These systems include residential air conditioning and heat pump systems utilizing different components and refrigerants, and water chiller systems. Most of these studies show similar trends for the effect of charge degradation on system performance. However, it is found that although much experimental work exists on the effect of charge degradation on system performance, no correlation or comparison between charge degradation and system performance yet exists. Thus, based on the literature review, three different correlations that characterize the effect of charge on system capacity and energy consumption are developed for different systems as follows: one for air-conditioning systems, one for vapor compression water-to-water chiller systems, and one for heat pumps. These correlations can be implemented in vapor compression cycle simulation tools to obtain a better prediction of the system performance throughout its lifetime. In this paper, these correlations are implemented in an open source tool for life cycle climate performance (LCCP) based design of vapor compression systems. The LCCP of a residential air-source heat pump is evaluated using the tool and the effect of charge degradation on the results is studied. The heat pump is simulated using a validated component-based vapor compression system model and the LCCP results obtained using the three charge degradation correlations are compared.

Air Conditioning↗