Search NASASearch

SEARCH · Search NASA

Results for “performance envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Life-Cycle Analysis of Residential Windows Retrofits: Net GHG Emission Reduction and Payback Periods

Windows are a critical envelope component that plays an important role in the overall performance and environmental impact of a building life cycle. These implications can be embedded in the window lifecycle related to its design, manufacturing, raw materials and transportation, performance during the building’s use (operational), replacements, maintenance and end-of-life. Windows may impact 25% of the heating and cooling energy use, 10% of total building energy use and 45% of the envelope heat transfer (Harris 2022). The impacts of windows on the energy consumption of buildings have been extensively discussed, however, its embodied life-cycle impacts, such as greenhouse gas (GHG) emissions, and the trade-offs between the embodied and its operational emissions are less explored. Understanding the life cycle impacts of windows may subsidize decision making process and inform the development of emerging windows technologies. BTO’s Windows Program has played an important role to increase the adoption of emerging technologies as high-performance windows in the U.S. (Harris 2022) and to consider the GHG emission impacts of the those windows is an important aspect that can support the strategic objectives and the performance targets from the national blueprint for decarbonizing the buildings sector and to reduce the on-site emissions and embodied life cycle emissions from building materials and construction (US DOE 2024).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

AmpSuite

Seismic amplitudes offer vital information about explosion source characteristics, including discrimination and yield estimation. To take advantage of this, we developed an interactive Python package to measure, control data quality, generate broad area propagation models and perform discrimination and estimate yield. Propagation models are essential in support of transportable yield and broad area discrimination. The key benefit of this package will be its ability to continuously integrate data and new techniques. The AmpSuite framework will provide standardized, repeatable, and accurate model generation and characterization routines. The capability is crucial for monitoring agencies tasked with rapid and high-quality seismic event characterization. The AmpSuite software includes a series of independent modules to perform: • Direct Phase Amplitude Measurement and Storage • Coda Envelope Measurement and Storage • Data Quality Control • New Propagation Model Developments • Seismic Discrimination and Analysis • Yield Estimation and supporting utility software. The AmpSuite software provides comprehensive solutions for monitoring agencies seeking to optimize model generation and event analysis within a contemporary Python framework. Stakeholders (AFTAC) have begun to move towards the Python language for scientific analysis as a new workforce emerges.

Alfaro, Richard

Optics Reconstruction in the SCL Section of the FNAL Linac

The Side-CoupledLinac (SCL) section oftheFNAL linac acceleratesthe beamfrom 117 MeV to 401.5 MeV, operatingat 22-24mA beam current. Transverse focusing is performedby32 quadrupoles, and the beam orbit is guidedby19dipolecorrectors andmeasuredby29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings o fan upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code Trace Win. A comparison between Trace Win simulations and the beam envelope measured bythe12wirescanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance of the transition section will be reported

Carneiro, Jean-Paul [Fermilab]

Importance of Window Installation in Residential Building Envelopes Having Continuous External Insulation in Order to Realize Energy Efficiency

Residential buildings are one of the prime candidates in the United States for reducing energy consumption. Continuous exterior insulation (CEI) is being used increasingly often in residential buildings to improve energy efficiency. Windows constitute 15–40% of a building envelope and are the weakest component in energy performance. The installation of windows in walls with CEI has not been well evaluated. We identified four cases of installing windows in walls with CEI of 25–76 mm (1–3 in.) thickness and analyzed the energy loss between the window and wall interface (flanking loss), structural issues, air leakage, and moisture penetration. Thermal analysis showed that the insulation value (RSI) of the 305 mm (12 in.) perimeter wall surrounding a window decreased by 7.6–34.5% in the four cases when compared with the RSI of the wall without the window. A window installation method is proposed to address the issues likely to occur with installation methods currently being used in the field. An out-of-the-box installation system was also designed to achieve a better thermal performance, cost effectiveness, and structural performance in high-performance residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Multimetallic Layered Composites (MMLCs) for Rapid, Economical Advanced Reactor Deployment (Final Report)

This project focused on the development of multi-metallic layered composites (MMLCs) for advanced fission reactor technologies. There are many instances where one alloy or material simply cannot meet all the demands thrown at it by a reactor system, or cannot allow it to perform as strongly as one would like. Instead of focusing all our effort on developing one perfect alloy, we seek to leverage the design principle of “separation of functionality,” used in many other arenas in design, to boost performance beyond single alloys alone. One illustrative example shows the power of this approach for molten salt-cooled reactors: A three meter tall, three meter diameter reactor vessel made of Incoloy 800 was quoted at $\$$500k in 2018. A Hastelloy N vessel was quoted at $\$$5M. An MMLC vessel, in which a layer of Hastelloy N would be weld-overlaid onto Incoloy 800, was quoted at $\$$700k, and it would achieve the same performance. The potential economic gains of leveraging this approach are therefore substantial. At a minimum, each MMLC would contain one core structural layer and one coolant-facing corrosion-resistant layer. Sometimes, MMLCs required buffer layers, as the structural and corrosion-resistant layers were metallurgically incompatible. In other words, they didn’t always play nice, thus separating layers compatible with both functioned as intermediaries to keep the composite together. However, in doing so we inevitably produce new interfaces, where new issues can arise. Therefore, this project focused on what happens at these interfaces from a combination of high temperatures, irradiation, corrosion, and time. After all, a reactor makes money when it is operating, and outages of any kind erode its economic viability. First, we set out to experimentally prove that MMLCs for at least two advanced reactor systems can be made, today, in US domestic facilities. In this respect we were successful – one MMLC (a Ni-201/Incoloy 800H composite) was successfully made and drawn into two-inch coolant piping. Others were attempted, though new issues relating to cracking in vanadium layers for one and radiation damage performance of the corrosion-resistant layer in another prevented us from moving further in those specific arenas – these are engineering problems which deserve continued focus after this project. Additional experimental work focused on long-term corrosion testing of the outermost layers of the salt-cooled and liquid lead-cooled MMLC concepts, which would then be fed into predictions of how long the MMLCs could last. Next, computational (thermodynamics and atomistic) simulation studies studied how much we expect the interfaces to “blend,” due to the mixing action of neutron irradiation. This eats into both the margin for the structural layer of each MMLC, as dilution from the corrosion-resistant layer into the structural layer would decrease the total load-bearing capacity of an MMLC of finite size. On the other hand, dilution of the corrosion-resistant layer into the structural layer further reduced the margin of corrodible material, reducing the lifetime of the MMLC or necessitating extra thickness to be imparted to the MMLC to meet its functional requirements. Work here focused on irradiation-induced segregation to predict new phases which may embrittle the MMLCs, as well as quantifying irradiation-induced mixing at each interface. The results showed that mixing is expected, but it is both steady and therefore predictable, and not lifetime-limiting for most MMLC concepts – it simply has to be accounted for in calculations of reactor performance when utilizing an MMLC. Then, full-core simulations using the experimentally-derived corrosion data, the computationally discovered irradiation-induced mixing data (partially validated by experiment), and existing, benchmarked core designs for large and small sized reactor concepts (one salt-cooled, one lead-cooled) were conducted to quantify any expansion of reactor operating envelopes achieved by utilizing these MMLCs. This new framework, called REX (Reactor Envelope Expansion), incorporates a combination of core neutronics, thermal hydraulics, and the material performance data derived from this project to see how using an MMLC expands advanced fission reactor operating envelopes. It was discovered that in some cases, MMLC utilization does indeed increase the maximum operating temperatures and cycle lengths of reactor concepts, while in other cases it does not. Finally, our tech-to-market (T2M) strategy was not necessarily to create specific embodiments of MMLCs for immediate sale (because getting into the nuclear market is incredibly slow and laden with regulation, this is a long-term goal), but rather immediate stimulation of US industry using the design approach of MMLCs derived from this project. In this respect we were successful, as one of the PhD students funded on this project co-founded Allium Engineering, Inc., which created a stainless steel / low-alloy steel MMLC to function as chloride corrosion-resistant rebar for embedding into concrete structures. Allium Engineering continues to be successful, having recently opened their first factory as of this writing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Report on RIA Relevant Modified Burst Testing of ATF Cladding Materials

The mechanical performance of accident-tolerant fuel (ATF) cladding candidates in light-water reactors (LWRs) must be similar to or better than that of current conventional nuclear fuel claddings to reduce dose to the public and ensure a that the core coolable geometry is maintained during a postulated reactivity-initiated accident (RIA) in light-water reactors (LWRs). During an RIA event, the rapid thermal expansion of nuclear fuel can deform the cladding once the fuel–cladding gap closes. In some cases, the pellet–cladding mechanical interaction (PCMI) can induce mechanical failure in ATF candidates. Thus, the mechanical response of ATF cladding must be investigated by mimicking the conditions of RIA and potentially performing Transient Reactor Test (TREAT) experiments to establish or verify the safety envelope. The work presented in this report investigated the failure behavior of as-received, hydrided, and chromium-coated (Cr-coated) Zircaloy-4 (Zry-4) cladding tube under strain-driven mechanical conditions, mimicking postulated RIA loading conditions. Mechanical testing was performed at 300°C via modified burst test (MBT) equipment with pulse width control previously developed under the Department of Energy’s (DOE’s) Advanced Fuel Campaign (AFC). The mechanical strains were determined using 2D digital image correlation (DIC) techniques. The base Zry-4 acquired by Cameco Inc. was in stress-relieved annealed (SRA) condition. Because of the observed large deformation of the cladding tubes, the failure strain definition was updated for the MBT, which can also be applied to other tube tests where significant bulging (out-of-plane deformation) is present. The failure strain was determined to be affected by the speed of the test or the RIA event. As the RIA-like event duration decreased from 75 to 15 ms, the failure strain decreased 5, 7 and 1% for as-received, hydrided, and Cr-coated specimens, respectively. Fractography on the Cr-coated specimens indicated the presence of two failure mechanisms: (i) crenulation at the outer surface of the coating due to the tensile tractional forces along with coatings grain microstructure and (ii) formation of critical defect at the coating/cladding interface that initiated coating rupture after severe plastic deformation of the Zry- 4 substrate. Based on the MBT results and fractography observations, performing mechanical property testing at high strain rates—in particular on Cr-coated tubes—and semi-integral TREAT experiments are required future efforts to ensure ATF cladding performance during transients. The testing recommended would also inform the development of long-term generalized cladding technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]

Optics reconstruction in the SCL section of the FNAL Linac

The Side-Coupled Linac (SCL) section of the FNAL linac accelerates the beam from 116 MeV to 401.5 MeV, operating at 22-24 mA beam current. Transverse focusing is performed by 32 quadrupoles, and the beam orbit is guided by 19 dipole correctors and measured by 29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings of an upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code TraceWin. A comparison between TraceWin simulations and the beam envelope measured by the 12 wire scanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance and exit of the SCL section will be reported.

Carneiro, Jean-Paul [Fermilab]

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A product data network to enable faster, easier, and better planning of building envelopes

The building envelopes contributes significantly to the energy-efficiency of the building. Building performance simulation has made it possible to compare façade technologies regarding energy demand, daylighting, thermal and visual comfort in detail. Planners, such as architects and engineers, need experience to find product data with the right quality and level of detail, and to process the data to fit the calculation and the application. In the available time, planners can compare only a limited number of products, which means that better solutions could go unnoticed. This paper presents a new concept for making product data easily accessible for building façade planning. The concept consists of a network of databases for the efficient exchange and use of optical and calorimetric data of glazing units, shading devices, and combinations of both. The paper presents the research questions, an analysis of the current challenges, six design goals for the product data network and its implementation together with a discussion. Many product data sources can be connected to many planning software applications via the specified application programming interface. When planning software connects to the product data network, the planning of building envelopes can be much faster because planners do not need to spend so much time to search and process product data manually. The planning of building envelopes can also become much easier, especially for planners with limited experience. They do not need to understand all the details about which data fits which calculation if the software company implements this. The planning of building envelopes can become much more reliable when software companies validate their use of the product data network, because the current manual process is prone to errors. The planning of building envelopes can also improve because more products can be compared in the available time, allowing better solutions to be found.

Maurer, Christoph

Minimized aging of isocyanurate-based rigid cellular foams for buildings through tailored barrier facers and optimized formulation

The thermal resistivity (h·ft 2 ·°F/Btu/in.) of closed-cell rigid foam insulation materials significantly decreases over time. Diffusion-tight facers are designed to significantly enhance initial thermal resistivity and long-term thermal performance by preventing gas diffusion into the foam cells and inhibiting the escape of low thermal conductivity blowing agents. In addition to the gas diffusion property of the facer film, adhesion between the foam and the facer is crucial for achieving diffusion-tight bonding. Here, this study addresses the challenge of thermal aging by investigating how facer film properties and foam formulation influence the durability of thermal performance. A systematic evaluation was conducted to understand the effects of polymeric barrier films, surface treatments, facer coverage, and foam matrix rigidity on thermal resistivity over time. Key findings reveal that diffusion-tight facers, particularly those with metallized layers and compatible heat seal layers, significantly reduce gas exchange and improve foam-facer adhesion. The optimized system, incorporating barrier facers and a tailored polyisocyanurate foam formulation, achieved initial and aged thermal resistivity values after 200 days of approximately 8.3 and 7.4 h ft 2 ·°F/Btu/in., respectively representing only a 10 % reduction compared to a 17 % reduction observed in control samples without facers. Notably, polyurethane spray foams with facers exhibited only a 4 % reduction in thermal resistivity, compared to a 23 % decrease in control samples, demonstrating nearly six times better retention of thermal performance. This innovative facer technology presents a promising solution for reducing energy costs and represents a significant advancement in optimizing energy management for building envelopes in future technologies. This technology can also be adapted for other applications that necessitate the preservation of long-term thermal performance.

Wanasinghe, Shiwanka Vidarshi [Oak Ridge National

Realizing the Residential Electrification Opportunity: One Heat Pump at a Time

Space and water heating in residential buildings is a major contributor of greenhouse gas (GHG) emissions in the United States. Advanced electric heat pumps (HP) and heat pump water heaters (HPWH) are poised to provide a low carbon alternative to traditional fossil-based space and water heating. Widespread deployment of heat pumps could help address the significant portion of building emissions and primary energy used in American households, however much work needs to be done to close the knowledge gap between like-for-like fossil equipment replacement and switching to HPs for the average contractor. The Pacific Northwest National Laboratory (PNNL) has been working on closing this knowledge gap through the development of decision tools and resources targeted towards contractors and installers. Developed in coordination with stakeholders and experienced contractors from a variety of geographic regions, these tools help streamline the process of sizing and selecting residential HPs and HPWHs for key use cases. Along with the complementary Retrofit Decision Tool developed by PNNL, the decision tools will help contractors understand the importance of whole building considerations when choosing HPs including envelope upgrades, duct assessments, and electrical assessments to ensure optimal selection and performance of the HP or HPWH. They also provide direct links to resources and best practices developed by PNNL as well as external entities to further help contractor education and training. This paper describes the development of these tools, and their role in moving the existing space and water heating market towards HPs to help realize the country’s decarbonization goals.

heat pump, heat pump water heater, Residential bui

Quantifying Message Aggregation Optimisations for Energy Savings in PGAS Models

Upon breaking past the exascale barrier, HPC systems are facing their greatest challenge yet - a power wall that must be addressed through new methods in both hardware and software. While energy costs are becoming a major issue at all levels, of particular concern is that of the network, as the relative cost of moving data is increasing faster than ever. The partitioned global address space (PGAS) model is critical within certain HPC domains, but is known to suffer from the small message problem, where irregular many-to-many access patterns result in congesting the network with excessive numbers of small messages. To address this, the conveyor aggregation library was developed to defer individual messages and group them for subsequent bulk processing. In this paper, we investigate its impact on energy use related to the network, with a focus on the Slingshot 11 interconnect. We will demonstrate that this strategy is not only highly performant, but also crucial to reducing energy footprints to remain within target power envelopes.

Welch, Aaron [ORNL]

Making Small-Volume Heat Pump Water Heaters Larger: A Design Framework for Integrated Phase Change Material Heat Exchangers

Those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. One major barrier to wider HPWH adoption is the added equipment required, which prevents current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). PCMs have been studied extensively in building envelope and HVAC systems, but remain a nascent technology in residential water heating. While water itself has a uniquely high energy storage capacity, PCMs have an even higher energy storage density, thus providing the potential to elevate the performance of 40-gallon HPWHs to that of 50-gallon or larger tanks. This research is part of a larger project that seeks to utilize thermal energy storage to enable decarbonized water heating in low-income communities. In this study, we outline the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. In order to ensure optimal PCM utilization and tank storage capacity, we focus here on co-maximizing surface area and PCM volume in the heat exchangers; therefore, this research targets triply periodic minimal surface (TPMS) lattices. TPMS lattices boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries and offer highly tailorable designs; thus, they pair well with the growing field of additive manufacturing, or 3D printing. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives.

25 ENERGY STORAGE

A review of prefabricated overclad panels for building energy retrofits

Over 50% of existing buildings in the US were constructed before 1980 and lack modern, energy-efficient technologies. Despite the large number of old buildings, less than 2% of buildings are retrofitted each year with many of those retrofits consisting of small incremental improvements that often ignore the building envelope. The opaque building envelope affects 25% of building energy use equating to 10% of total US primary energy use. To meet decarbonization goals by 2035, the US must increase the rate of retrofit of existing building envelopes. The process of prefabrication is one potential opportunity to increase the rate of envelope retrofits and reduce costs. Prefabrication is the process of manufacturing construction components in a controlled environment before shipping them on-site to perform assembly of the construction. The process of prefabrication has been demonstrated to increase production efficiency, quality control, and rate of production. Prefabricated overclad panels, consisting of a cladding material and insulation designed to be installed over the existing envelope, have been successfully used to retrofit existing buildings in countries other than the US; however, the technology still has some barriers to major market adoption within the US. This paper will present a review of current implementations and demonstrations of prefabricated overclad panels. The review will include identification of panel types, materials, and applications and aims to identify barriers to retrofit market entry and widespread adoption.

Hayes, Nolan [ORNL] (ORCID:0000000332245718)