Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Current loss analysis in photoelectrochemical devices

Ongoing efforts to stabilize the operation of photoelectrochemical (PEC) devices remain critical for achieving economically viable solar fuel production, as devices with lifetimes on the order of 10 to 30 years are projected requirements for utility-scale, PEC device implementation. However, insight into the causes of device degradation and activity losses is generally provided by monitoring the device current, a quantity which masks the relative contributions of photovoltaic component degradation and electrocatalyst activity drops to overall performance losses. In this study, an approach for deconvoluting the various contributors to PEC device losses is described. In particular, the causes for observed fluctuations in device performance are determined through the collection of real-time, current–voltage data, paired with an analytical method that enables the decomposition of drops in device current into its constituent photovoltaic- and catalyst-driven performance losses. We test the validity of this approach by applying it to the data collected for a PEC hydrogen evolution test-bed.

14 SOLAR ENERGY↗

Demonstration of Electrochemically-Driven CO 2 Separation Using Hydroxide Exchange Membranes

Hydroxide exchange membrane fuel cells (HEMFCs) are a potentially lower-cost hydrogen fuel cell technology; however, ambient levels of CO 2 in air significantly reduce HEMFCs’ performance. In this work, we demonstrate an electrochemically-driven CO 2 separator (EDCS) which can be used to remove ambient levels of CO 2 from air upstream of the HEMFC stack in fuel cell vehicles, protecting it from CO 2 -related performance losses. The EDCS operating window was explored for current density, anode flow, and cathode flow with respect to its impact on CO 2 separation performance. Additionally, gas-phase mass transport was improved by selecting flow fields and gas diffusion layers conducive to the EDCS operating regime. The use of a carbon-ionomer interlayer at the cathode was explored and improved CO 2 removal performance from 77.7% to 98.2% at 20 mA cm −2 . An analytical, 1-D model is used to explain the experimental observations and design improvements. A single-cell, 25 cm 2 EDCS using the aforementioned improved design demonstrated greater than 98% CO 2 removal at a cathode flow rate of 1300 sccm for 100 h with 2.7% hydrogen stack consumption.

Matz, Stephanie↗

Nanoporous Iridium Nanosheets for Polymer Electrolyte Membrane Electrolysis

The growth of the hydrogen economy is predicated on advancements in electrochemical energy technologies, with water electrolysis as a key component to the technological portfolio. Much of the focus on anode catalyst development for polymer electrolyte membrane water electrolyzers (PEMWE) is centered on activity as controlled by compositional and morphological impacts on reactant/intermediate/product adsorption. However, the effectiveness of this strategy is found to be limited upon integration of these materials into PEMWE membrane electrode assemblies (MEA). Regardless of catalyst activity, the combination of electrode inhomogeneity, ionomer integration, and high density of oxide-oxide interfaces yields significant performance losses associated with poor catalytic electrode conductivity. Here many of these limitations are addressed through the development of a unique catalyst morphology composed of nanoporous Ir nanosheets (npIr(x)-NS) that exhibit high catalytic activity for the anodic oxygen evolution reaction and superior electrode electronic conductivity in comparison to a commercial IrO2 nanoparticle catalyst. The utility of the npIr(x)-NS is demonstrated through incorporation into PEMWE MEAs where their performance exceeds that of commercial catalyst coated membranes at loadings as low as 0.06 mg(Ir) cm(-2) while exhibiting a negligible loss in performance following 50 000 accelerated stress test cycles.

Polymer Electrolyte Membrane Electrolysis↗

The Impact of Membrane Inactive Area on the Durability of Pt-Co Catalyst

Platinum (Pt) is the most active catalyst for oxygen reduction reaction; however, its activity still requires a significant increase to meet the demands of practical applications. To enhance the catalytic activity, alloy catalysts like platinum-cobalt (Pt-Co), are being extensively investigated. However, Co leaching from the Pt-Co alloy remains a significant concern. Evaluating the durability of Pt-Co alloy catalyst is further complicated by variations in Co leaching, which affects both the observed performance and durability. This variability often arises from an overlooked factor: choice of the inactive area of the membrane electrode assembly (MEA) used during the evaluation. This study examines the critical role of membrane inactive area on the performance loss observed during durability testing of Pt-Co alloys. Our findings indicate that a large membrane inactive area reduces the impact of Co leaching on performance and durability, up to 200 mA cm −2 difference in performance is observed between large and small inactive area MEA at 0.7 V for dry conditions, and more Co is retained in the active area of MEA for smaller inactive areas which is responsible for larger performance losses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long Term Degradation of LSM Based SOFC Cathodes: Use of a Proven Accelerated Test Regimen

The overall goals of the program were: • To understand the microstructural basis of long-term performance loss in solid oxide fuel cells (SOFCs) with cathodes based on lanthanum strontium manganite (LSM, (La 1–x Sr x ) 1–yM nO 3±z ); • To develop strategies for optimizing LSM–based cathodes that achieve improved long-term performance, while exhibiting microstructural and chemical stability, for commercial fuel cell systems. The research project carried out accelerated testing of SOFCs with LSM-based cathodes of selected compositions. After intervals of accelerated testing (and control tests using non-accelerated conditions), the cells underwent extensive microstructural characterization to determine the physical and chemical changes in the cells. By analysis of a) the results of the testing, b) the observed microstructural changes, and c) the differences in these correlations between different cathode compositions and test durations, the research: • Identified a correlation between microstructural change and performance loss: specifically, between decrease of three-phase boundary (TPB) density and increase of area specific re-sistance (ASR) during operation; • Identified a cathode composition parameter — Mn excess, defined as 1/(1–y) in (La 1–x Sr x ) 1–y MnO 3±z ) — and how it affects TPB density, ASR and change of cell performance over time.

08 HYDROGEN↗

Comprehensive model for evaluating voltage losses and performance improvements in thin-film photovoltaic devices

Progress of state-of-the-art and next-generation thin-film photovoltaic devices is often stymied by open-circuit voltage (𝑉 oc ) that is significantly lower than theoretical and practical limits. Yet, effectively diagnosing the primary sources of voltage loss remains challenging. Herein, a sequence of device-level characterization techniques and simulations are employed to identify and rank loss mechanisms. For the research-based Cd⁡(Se,Te) device under study, most of the loss was at the front semiconductor heterointerface due to a clifflike conduction-band offset that lowered the recombination activation energy. Additional losses due to band tails were quantified by photoluminescence analysis. The latter provided the absorption coefficient and activation energy reduction associated with band tails as inputs to device models. Simulations showed that alleviating front-interface issues would improve 𝑉 oc , but it would then be limited by bulk recombination. Further improvement of the bulk would then lead to back-contact limitations. Reducing band tails is beneficial in any circumstance. In conclusion, this analysis provides guidance for reaching toward the radiative 𝑉 oc limit.

14 SOLAR ENERGY↗

Degradation Mechanisms in Advanced MEAs for PEM Water Electrolyzers Fabricated by Reactive Spray Deposition Technology

Proton exchange membrane water electrolyzers (PEMWEs) have demonstrated enormous potential as the next generation hydrogen production technology. The main challenges that the state-of-the-art PEMWEs are currently facing are excessive cost and poor durability. Understanding the failure modes in PEMWEs is a key factor for improving their durability, lowering the precious metal loading, and hence cost reduction. Here, reactive spray deposition technology (RSDT) has been used to fabricate a membrane electrode assembly (MEA) with one order of magnitude lower Pt and Ir catalyst loadings (0.2–0.3 mg PGM cm –2 ) in comparison to the precious metal loadings in the stat-of-the-art commercial MEAs (2–3 mg PGM cm –2 ). As fabricated MEA with an active area of 86 cm 2 , has been tested for over 5000 h at steady-state conditions that are typical for an industrial hydrogen production system. Herein, we present and discuss the results from a comprehensive post-test analysis of the MEA of interest. The main degradation mechanisms, governing the performance loss in the RSDT fabricated MEA with ultra-low precious metal loadings, have been identified and discussed in detail. All failure modes are critically compared and the main degradation mechanism with the highest impact on the MEA performance loss among the others is identified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional Surface Coating to Enhance the Stability of LiNi 0.6 Mn 0.2 Co 0.2 O 2

Parasitic reactions are responsible for continuous performance loss during the normal operation and storage of lithium-ion batteries, particularly for those using nickel-rich cathode materials. Among many contributors, residual Li 2 CO 3 on the surface of nickel-rich cathodes plays a detrimental role in promoting parasitic reactions, and hence accelerates the performance loss of those cathode materials. In this work, a wet impregnation process was utilized to convert the detrimental Li 2 CO 3 and LiOH impurities into a beneficial functional surface coating comprising phosphates. Specifically, hydro-phosphates were used as the functional surface modification agents to mitigate the detrimental effect of surface residuals. The best electrochemical performance was achieved by modifying LiNi 0.6 Mn 0.2 Co 0.2 O 2 with a diluted dihydro-phosphate solution (pKa = 7.2), while the metal cation had a negligible impact on the electrochemical performance. This work provides a cheap and simple method for enabling the high performance of nickel-rich cathodes.

25 ENERGY STORAGE↗

PV Fleet Performance Data Initiative 2026 Update

We provide an update on the PV Fleet Performance Data Initiative at the 2026 PV Reliability Workshop. Our latest runs incorporate additional data sources and an integrated analysis pipeline run on our Kestrel HPC cluster. Initial degradation findings suggest that single-axis tracked PV systems exhibit higher performance loss rates than fixed-tilt systems, an increase of 0.5 %/yr, almost double. We discuss multiple methods for identifying stuck tracker rows, which are suspected to be a contributor to the enhanced degradation. Through satellite image detection and data-driven approaches we address the topic of identifying when stuck trackers are occuring and to what extent the problem exists. Preliminary results suggest that the increased performance loss detected for the tracked systems would be consistent with stuck tracker rows affecting on the order of 5% - 10% of the system.

14 SOLAR ENERGY↗

Resiliency-based restoration optimization for dependent network systems against cascading failures

Due to the increasing importance of large-scale and complex network systems and the potential for massive cascading failures in these real-world systems, modeling of system resiliency and optimization of restoration strategies to mitigate system performance loss caused by diverse disruptions is of significant interest among researchers and practitioners. Although society has experienced many incidents that demonstrate the influence of cascading failures aggravated by dependencies inside network systems, existing resiliency-based restoration optimization research rarely if ever jointly considers the impact of system dependencies on cascading failures. In this paper, different restoration prioritization strategies are applied to network systems subject to cascading failures that take into account system dependencies. By conducting case studies on synthetic networks and the U.S. airport network system, the effects of restoration strategies are evaluated using a system resiliency metric and two system performance measurements. Furthermore, the influence of system dependency characteristics and the interplay between them and restoration strategies on system resiliency regarding cascading failures are also investigated. This work demonstrates the distinct effects of restoration prioritization actions against cascading failures to mitigate the performance loss in network systems with different properties. It also provides insights about restoration improvement by considering dependency impacts to effectively reduce the intensity and extent of cascading failures.

42 ENGINEERING↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

DEVELOPMENT OF TRANSIENT FISSION GAS RELEASE CAPABILITIES TO STUDY HIGH BURNUP COMMERCIAL FUEL PERFORMANCE UNDER LOSS OF COOLANT ACCIDENT CONDITIONS

The contribution of transient fission gas release to the burst behaviour of high burnup fuel during a loss of coolant accident (LOCA) for commercial light water reactors is a complex phenomenon that is not fully understood. During the temperature ramp associated with a LOCA, there is significant, additional transient fission gas release in excess of steady state fission gas release from normal operation. The timing of this release and the various conditions that impact this release warrant further study. To better characterize this phenomenon, a system was developed to capture and characterize fission gas released from irradiated fuel during simulated LOCAs. This system is an upgrade to the existing Oak Ridge National Laboratory Severe Accident Test Station LOCA test apparatus and detects fission gas by gamma counting cryogenically cooled cold traps and by using an online gas mass spectrometer. The examined fuel can be pressurized or open to the furnace atmosphere. The design and operation of this new capability are discussed. Results from the first tests on high burnup fuel are presented. In the initial test, the LOCA relevant transient fission gas release was 5.3% for an unpressurized segment. Post-test microscopy on the tested samples is presented to demonstrate the likely radial source of transient fission gas release.

Harp, Jason↗

Advanced Signal Decomposition Analysis and Anomaly Detection in Photovoltaic Systems

With the rapid expansion of large-scale photovoltaic (PV) plants, it is paramount for solar stakeholders to understand the reliability and efficiency of their plants to inform maintenance decisions, increase production, and understand the design factors that impact performance. Diagnosing underperformance in PV plants is challenging due to the relatively few monitoring points with respect to the large geographic footprint of the plant. This work introduces a cutting-edge method that transforms the analysis and management of key factors influencing PV plant performance, including performance loss rate (PLR), recoverable soiling, and major system changes. Identifying these factors is critical for deriving actionable insights. Leveraging advanced analytical techniques such as wavelet transformation, robust regression, and extreme point analysis, this approach provides a nuanced understanding of these factors. This method has been tested across two synthetic datasets and one real dataset, consistently surpassing existing benchmarks by achieving a lower median mean absolute error and reduced error variability across all comparable components.

14 SOLAR ENERGY↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative Program and Methodology

The US Department of Energy’s PV Fleet Performance Data Initiative has been launched in order to collect and evaluate production data across multiple PV fleet partners. Performance statistics are anonymized, aggregated and shared to represent a snapshot of the US commercial and utility-scale fleet. Production data have been collected from over 1500 systems representing more than 1.3 GWdc capacity. Preliminary analysis indicates median performance loss rates are in line with previous publications of system degradation, on the order of –0.6%/yr to –0.9%/yr (preliminary numbers subject to change). These values are higher than module-only degradation rates which are often used in pro-forma estimates of project performance and economics, potentially exposing owner/operators to increased risk if systems under-perform over time.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Improved CdTe PLR Estimates: Self-Shading and Spectral Mismatch

The RdTools year-on-year method of estimating performance loss rate (PLR) employs a simple normalization to remove the confounding effect of irradiance and temperature variation. However, the normalization's assumption that PV production scales linearly with in-plane broadband irradiance is a worse approximation for CdTe and other technologies with larger spectral sensitivities than it is for the more common c-Si technology. Additionally, CdTe systems using single-axis trackers (-20% of installed US utility-scale capacity) are subject to self-shading in the morning and afternoon, introducing another nonlinearity between PV output and broadband irradiance. Ignoring these effects may subject the estimated PLR to increased uncertainty, and perhaps bias, depending on the character of their short- and long-term variability. In this work we show that including self-shading and spectral mismatch models in the normalization for tracking CdTe systems can result not only in tighter PLR confidence intervals but different median PLRs as well. The shading and spectral models are kept simple to maintain consistency with the RdTools ethos of not requiring detailed system metadata or unusual measurements.

CdTe↗

Understanding and Overcoming Water-induced Interfacial Degradation in Si Modules (Final Technical Report)

Moisture ingress is an established issue for photovoltaic module durability. Durability studies probing moisture effects typically evaluate performance losses at the module level, attributing global power losses to the overall humidity condition of the test environment while leaving local module behavior unknown. This project successfully develops an in situ short-wave infrared probe of moisture content in PV modules with demonstrated detection limits better than 100 ppm in EVA-encapsulated Al-BSF and PERC architectures (66 µg/cm3) and applicability across the range of terrestrial conditions. Combining this optical moisture quantification method (water reflectometry detection, WaRD) with peel testing of interfaces, biased photoluminescence imaging of performance, and first principles computation, we correlate module moisture content and cell performance over the course of accelerated damp heat tests. By performing multi-level humidity and thermal accelerated testing over thousands of hours (0, 65 and 85% RH and 25, 65, and 85°C), we are able to attribute effects of individual environmental stresses and the dependence on module architecture. Using first-principles computational chemistry, we find that the decomposition of EVA to acetic acid (Norrish II) is thermodynamically preferred over a pathway to acetaldehyde (Norrish I), elucidating the underlying chemistry of encapsulant degradation. We also find it is likely that water segregates to the stable interfaces of the cell, especially the SiNx/EVA interface. We find that moisture is strongly correlated with reduction in adhesion at the interfaces of the cells, particularly at Ag fingers. We show uniquely that the peel strength required to delaminate the encapsulant from the front of the cell depends not only on the exposure to a high heat and humid environment, but also to the moisture content during the mechanical testing, indicating an important interaction between when mechanical stresses are faced in terms of the moisture content of the module and its durability. We find that the background sheet resistance (that is, the sheet resistance rise not attributable to finger interruptions or cracks) is substantially higher in the backsheet mini-modules vs glass-glass packages when humidity and temperature are faced. This increase in power loss due to the background resistance increase over time in damp heat in glass-backsheet modules resulted in ~3-4% larger decrease in relative PCE compared to glass-glass modules. In glass-backsheet modules, the effect of the moisture dose alone is comparable or greater than that of the combined temperature and water term, suggesting that glass-backsheet modules are overall more susceptible to moisture induced performance loss. Finally, we show that thin film PV modules are amenable to WaRD measurement, based on the ability to detect moisture in POE encapsulants or in the cell stack itself. The ease of WaRD measurement and its few requirements on the bill of materials should enable broad applicability of this technique for studying the effects of moisture in PV.

14 SOLAR ENERGY↗