Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

LARGO hot water system thermal performance test report

The thermal performance tests and results on the LARGO Solar Hot Water System under natural environmental conditions is presented. Some objectives of these evaluations are to determine the amount of energy collected, the amount of energy delivered to the household as contributed by solar power supplied to operate the system and auxiliary power to maintain tank temperature at proper level, overall system efficiency and to determine temperature distribution within the tank. The Solar Hot Water system is termed a Dump-type because of the draining system for freeze protection. The solar collector is a single glazed flat plate. An 82-gallon domestic water heater is provided as the energy storage vessel. Water is circulated through the collector and water heater by a 5.3 GPM capacity pump, and control of the pump motor is achieved by a differential temperature controller.

Source record↗

Shuttle communication systems compatibility and performance tests

The compatibility and performance of the Shuttle communications system must be certified prior to operational missions. For this purpose, NASA has established the Electronics Systems Test Laboratory (ESTL) at the Johnson Space Center. This paper discusses the Shuttle communications system compatibility and performance testing being performed in the ESTL. The ESTL system verification test philosophy, including capabilities, procedures, and unique testing equipment are summarized. Summaries of the significant results of compatibility and performance tests of the Orbiter/Space-flight Tracking and Data Network, Orbiter/Air Force Remote Tracking Station, Orbiter/Tracking and Data Relay Satellite System and Orbiter/Shuttle Launch Support System interfaces are presented. The ESTL's unique ability to locate potential communication problems and participate in the resolution of these problems are discussed in detail.

Bromley, L. K.↗

System performance testing of the DSN radio science system, Mark 3-78

System performance tests are required to evaluate system performance following initial system implementation and subsequent modification, and to validate system performance prior to actual operational usage. Non-real-time end-to-end Radio Science system performance tests are described that are based on the comparison of open-loop radio science data to equivalent closed-loop radio metric data, as well as an abbreviated Radio Science real-time system performance test that validates critical Radio Science System elements at the Deep Space Station prior to actual operational usage.

Berman, A. L.↗

Performance Testing in the Secure Transport of Nuclear, Radiological, and other High-Risk Materials

A long established methodology for determining the effectiveness of an overall physical protection system (PPS) is through a healthy and robust performance testing program. Performance tests are vital because they provide essential information used in the determination of asset risk and the analysis of protection effectiveness. By establishing and verifying detection, assessment, response, interruption, and neutralization data, one can determine baseline protection effectiveness and consider upgrade scenarios and improving effectiveness. Performance testing also addresses the needs of multiple stakeholders, including the vulnerability assessment teams, site/facility personnel, and safety, and provides management with an independent, objective assessment of overall physical protection systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2

This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.

Platt, R.↗

Ambient Performance Testing of the CubeSat Infrared Atmospheric Sounder (CIRAS)

Hyperspectral infrared measurements of Earth’s atmosphere from space have proven their value for weather forecasting, climate science and atmospheric composition. The CubeSat Infrared Atmospheric Sounder (CIRAS) instrument will demonstrate a fully functional infrared temperature, water vapor and carbon monoxide sounder in a CubeSat sized volume for at least an order of magnitude lower cost than legacy systems. Design for a CubeSat significantly reduces cost of access to space and enables flight in a constellation to reduce revisit time and enable new measurements including 3D winds. A technology demonstration of CIRAS is currently under development at JPL. The effort has completed integration and ambient testing of a high fidelity brassboard, complete with the flight configured optics assembly developed by Ball Aerospace with a JPL Immersion Grating and Black Silicon Entrance Slit. The brassboard includes a flight-configured High Operating Temperature Barrier Infrared Detector (HOT-BIRD) mounted in an Integrated Dewar Cryocooler Assembly (IDCA), enabling testing in the ambient environment. Ambient testing included radiometric testing of the system to characterize the instrument operability and NEdT. Spatial testing was performed to characterize the system line spread function (LSF) in two axes and report FWHM of the LSF. Spectral testing involved an air path test to characterize the spectral/spatial transformation matrix, and an etalon was used to measure the Spectral Response Functions (SRFs). Results of the testing show the CIRAS performs exceptionally well and meets the key performance required of the system. The end result of testing is the CIRAS instrument now meets TRL 4 with confidence in a brassboard configuration ready for thermal vacuum (TVac) testing necessary to achieve TRL 5 for the system.

Wilson, Robert C.↗

X-38 De-orbit Propulsion Stage MLI Performance Test

This paper presents a performance test of the X-38 Deorbit Propulsion Stage (DPS) Multi-Layer Insulation (MLI) system. The purpose of this test is to determine if MLI performance meets or exceeds thermal analyses requirements and if there is performance degradation due to seams.

Kittredge, Ken↗

Performance Test and Validation Plan for the Neutron Slab Counter (Rev.1)

This Performance Testing and Validation Plan (PTVP) presents the technical basis for the use of the neutron slab counter (NSC) for quantitative nondestructive assay (NDA) measurements of compressor volutes from the K-25/K-27 Buildings. This PTVP prescribes a set of measurements required to calibrate and demonstrate sufficiency of the NSC for its intended purpose of quantitative NDA measurements of compressor volutes. The measurements taken according to this plan will be documented in a Performance Test and Validation Report (PTVR). Analysis of the collected data will be performed and documented in a Performance Test and Validation Evaluation. If the performance objectives are met, a commissioning report will be prepared establishing the uses and limitations of the NSC for its intended purpose.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Testing of Liquid Hydrogen Tanks

Testing the performance of liquid hydrogen in tanks brings many unique challenges. Often methods used even for liquid nitrogen need to be modified to be able to address the details required to fully understand the performance of the tank. During the development and characterization of many novel insulation systems both for in-space and ground applications, NASA has tested many liquid hydrogen tanks where performance was a key outcome. Over the course of analyzing the performance of multiple different hydrogen tests, including several with both hydrogen and nitrogen, differences in the details of test data interpretation become clear. One of these key details is the thermal stratification of the tank and what it can tell you about the heat load dispersion.

Liquid Hydrogen↗

Fabrication and test of a space power boiler feed electromagnetic pump. 3: Endurance and final performance tests

A three-phase helical induction electromagnetic pump designed for the boiler feed pump of a potassium Rankine cycle space power system was developed and built. It was mounted in a liquid metal test loop and successfully tested over a range of potassium temperatures from 900 to 1400 F, flow rates from 0.75 to 4.85 lb/sec, developed pressures up to 340 psi, net positive suction head from 1 to 22 psi, and NaK coolant temperatures from 800 to 950 F. Maximum efficiency at design point conditions of 3.25 lb/sec flow rate, 240 psi developed head, 1000 F potassium inlet temperature, and 800 F NaK coolant inlet temperature was 16.3 percent. After the performance tests the pump was operated without any difficulty at design point for 10,000 hours, and then a limited number of repeat performance tests were made. There was no appreciable change in pump performance after 10,000 hours of operation. A supplementary series of tests using the quasi-square wave power output of a dc to three-phase ac inverter showed that the pump would operate without difficulty at a frequency as low as 25 Hz, with little loss in efficiency.

Powell, A. H.↗

An attempt to validate the ultra-accelerated microbar and the concrete performance test with the degree of AAR-induced damage observed in concrete structures

There is little knowledge about the relation between AAR-induced damage observed in structures and the expansion potential obtained with accelerated tests. In this study, aggregates used in structures damaged by AAR were tested with the microbar test (MBT/AFNOR XP 18-594) and the concrete performance test (CPT/AFNOR P18-454). After the tests, the samples were examined using optical and scanning electron microscopy. Based on the results, the significance of the microbar test has to be examined very critically. The agreement of measured expansion, reacted rock types and the composition of the reaction products between the on-site concrete and the reproduced concrete subjected to the CPT clearly indicates that the reaction mechanisms in the structure and in the concrete performance test are comparable. As such, the concrete performance test seems to be an appropriate tool to test the potential reactivity of specific concrete mixtures.

36 MATERIALS SCIENCE↗

An extended life and performance test of a low-power arcjet

An automated, cyclic life test was performed to demonstrate the reliability and endurance of a low power dc cycle arcjet thruster. Over 1000 hr and 500 on-off cycles were accumulated which would represent the requirements for about 15 years of on-orbit lifetime. A hydrogen/nitrogen propellant mixture was used to simulate decomposed hydrazine propellant and the power level was nominally 1.2 kW after the burn-in period. The arcjet operated in a very repeatable fashion from cycle to cycle. The steady state voltage increased by approximately 6 V over the first 300 hr, and then by only 3 V through the remainder of the test. Thrust measurements taken before, during, and after the test verified that the thruster performed in a consistent fashion throughout the tests at a specific impulse of 450 to 460 sec. Post-test component evaluation revealed limited erosion on both the anode and cathode. Other thruster components, including graphite seals, appeared undamaged.

Curran, Francis M.↗

An extended life and performance test of a low-power arcjet

An automated, cyclic life test was performed to demonstrate the reliability and endurance of a low power dc cycle arcjet thruster. Over 1000 hr and 500 on-off cycles were accumulated which would represent the requirements for about 15 years of on-orbit lifetime. A hydrogen/nitrogen propellant mixture was used to simulate decomposed hydrazine propellant and the power level was nominally 1.2 kW after the burn-in period. The arcjet operated in a very repeatable fashion from cycle to cycle. The steady state voltage increased by aproximately 6 V over the first 300 hr, and then by only 3 V through the remainder of the test. Thrust measurements taken before, during, and after the test verified that the thruster performed in a consistent fashion throughout the tests at a specific impulse of 450 to 460 sec. Post-test component evaluation revealed limited erosion on both the anode and cathode. Other thruster components, including graphite seals, appeared undamaged.

Curran, Francis M.↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Reports: Final Comprehensive Performance Test Report, P/N: 1356006-1, S.N: 202/A2

This is the Performance Verification Report. the process specification establishes the requirements for the comprehensive performance test (CPT) and limited performance test (LPT) of the earth observing system advanced microwave sounding unit-A2 (EOS/AMSU-A2), referred to as the unit. The unit is defined on drawing 1356006.

Platt, R.↗

Acoustic and Aerothermal Performance Test of the Axisymmetric Coannular Ejector Nozzle: Acoustic Performance - Volume 2

Acoustic and propulsion performance testing of a model-scale Axisymmetric Coannular Ejector nozzle was conducted in the Boeing Low-speed Aeroacoustic Facility. This nozzle is a plug nozzle with an ejector design to provide aspiration of about 20% of the engine flow. A variety of mixing enhancers were designed to promote mixing of the engine and the aspirated flows. These included delta tabs, tone-injection rods, and wheeler ramps. This report addresses the acoustic aspects of the testing. The spectral characteristics of the various configurations of the nozzle are examined on a model-scale basis. This includes indentifying particular noise sources contributing to the spectra and the data are projected to full-scale flyover conditions to evaluate the effectiveness of the nozzle, and of the various mixing enhancers, on reducing the Effective Perceived Noise Levels.

Herkes, William↗

Solar-heating system performance tests

Report contains results of performance tests on complete system for solar space and hot-water heating system that uses commercially available components. Results were used to determine system suitability for field installation and to generate performance data base for comparison with future tests on field installed systems.

Source record↗

Thermal performance testing of the Explorer Platform

The Explorer Platform (EP) has been designed to accommodate on-orbit payload and bus module changeout via Space Transportation System (STS) servicing. Such a versatile spacecraft platform designed to experience widely different environmental exposures and operational conditions, coupled with program constraints on schedule and budget, presented a challenge to implementing a technically sound thermal vacuum/thermal balance test program. This paper discusses thermal performance tests implemented at the subsystem and system levels, and the risks accepted resulting from test sequence, configuration. and tests omitted from the program. No thermal cycling or thermal balance tests were performed on the integrated spacecraft level, although both the Payload (EUVE) and Platform (EP) received independent testing. The decision to take this approach is discussed with respect to the thermal design and the associated risks taken to maintain budget and schedule.

Wasson, David↗

Performance tests of signature extension algorithms

Comparative tests were performed on seven signature extension algorithms to evaluate their effectiveness in correcting for changes in atmospheric haze and sun angle in a Landsat scene. Four of the algorithms were cluster matching, and two were maximum likelihood algorithms. The seventh algorithm determined the haze level in both training and recognition segments and used a set of tables calculated from an atmospheric model to determine the affine transformation that corrects the training signatures for changes in sun angle and haze level. Three of the algorithms were tested on a simulated data set, and all of the algorithms were tested on consecutive-day data. The classification performance on the data sets using the algorithms is presented, along with results of statistical tests on the accuracy and proportion estimates. The three algorithms tested on the simulated data produced significant improvements over the results obtained using untransformed signatures. For the consecutive-day data, the tested algorithms produced improvements in most but not all cases. The tests indicated also that no statistically significant differences were noted among the algorithms.

Abotteen, R.↗