Search NASA⌕ Search

SEARCH · Search NASA

Results for “persistent image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Monitoring radiation use in cardiac fluoroscopy imaging procedures

Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance associated with relocation of the equipment to a new department. When tested under simulated conditions, the EWMA chart was capable of detecting a sustained 15% increase in average radiation output within 60 cases (<1 month of operation), while a 33% increase would be signaled within 20 cases. Conclusions: This technique offers a valuable enhancement to existing quality assurance programs in radiology that rely upon the testing of equipment radiation output at discrete time frames to ensure performance security.

60 APPLIED LIFE SCIENCES↗

Local optical control of ferromagnetism and chemical potential in a topological insulator

Many proposed experiments involving topological insulators (TIs) require spatial control over time-reversal symmetry and chemical potential. We demonstrate reconfigurable micron-scale optical control of both magnetization (which breaks time-reversal symmetry) and chemical potential in ferromagnetic thin films of Cr-(Bi,Sb) 2 Te 3 grown on SrTiO 3 . By optically modulating the coercivity of the films, we write and erase arbitrary patterns in their remanent magnetization, which we then image with Kerr microscopy. Additionally, by optically manipulating a space charge layer in the underlying SrTiO 3 substrates, we control the local chemical potential of the films. This optical gating effect allows us to write and erase p-n junctions in the films, which we study with photocurrent microscopy. Both effects are persistent and may be patterned and imaged independently on a few-micron scale. As a result, dynamic optical control over both magnetization and chemical potential of a TI may be useful in efforts to understand and control the edge states predicted at magnetic domain walls in quantum anomalous Hall insulators.

36 MATERIALS SCIENCE↗

An Extraordinary Outburst in the Massive Protostellar System NGC 6334I-MM1: Quadrupling of the Millimeter Continuum

Based on sub-arcsecond Atacama Large Millimeter/submillimeter Array (ALMA) and Submillimeter Array (SMA) 1.3 mm continuum images of the massive protocluster NGC 6334I obtained in 2015 and 2008, we find that the dust emission from MM1 has increased by a factor of 4.0 ± 0.3 during the intervening years, and undergone a significant change in morphology. The continuum emission from the other cluster members (MM2, MM4, and the UCH ii region MM3 = NGC 6334F) has remained constant. Long-term single-dish maser monitoring at HartRAO finds that multiple maser species toward NGC 6334I flared beginning in early 2015, a few months before our ALMA observation, and some persist in that state. New ALMA images obtained in 2016 July–August at 1.1 and 0.87 mm confirm the changes with respect to SMA 0.87 mm images from 2008, and indicate that the (sub)millimeter flaring has continued for at least a year. The excess continuum emission, centered on the hypercompact H ii region MM1B, is extended and elongated (1.″6 × 1.″0 ≈ 2100 × 1300 au) with multiple peaks, suggestive of general heating of the surrounding subcomponents of MM1, some of which may trace clumps in a fragmented disk rather than separate protostars. In either case, these remarkable increases in maser and dust emission provide direct observational evidence of a sudden accretion event in the growth of a massive protostar yielding a sustained luminosity surge by a factor of 70 ± 20, analogous to the largest events in simulations by Meyer et al. This target provides an excellent opportunity to assess the impact of such a rare event on a protocluster over many years.

79 ASTRONOMY AND ASTROPHYSICS↗

Functional Imaging of Microbial Interactions With Tree Roots Using a Microfluidics Setup

Coupling microfluidics with microscopy has emerged as a powerful approach to study at cellular resolution the dynamics in plant physiology and root-microbe interactions (RMIs). Most devices have been designed to study the model plant Arabidopsis thaliana at higher throughput than conventional methods. However, there is a need for microfluidic devices which enable in vivo studies of root development and RMIs in woody plants. Here, we developed the RMI-chip, a simple microfluidic setup in which Populus tremuloides (aspen tree) seedlings can grow for over a month, allowing continuous microscopic observation of interactions between live roots and rhizobacteria. We find that the colonization of growing aspen roots by Pseudomonas fluorescens in the RMI-chip involves dynamic biofilm formation and dispersal, in keeping with previous observations in a different experimental set-up. Also, we find that whole-cell biosensors based on the rhizobacterium Bacillus subtilis can be used to monitor compositional changes in the rhizosphere but that the application of these biosensors is limited by their efficiency at colonizing aspen roots and persisting. These results indicate that functional imaging of dynamic root-bacteria interactions in the RMI-chip requires careful matching between the host plant and the bacterial root colonizer.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced High-Speed Framing Camera Development for Fast, Visible Imaging Experiments

The advances in high-voltage switching developed in this project allow a camera user to rapidly vary the number of output frames from 1 to 25. A high-voltage, variable-amplitude pulse train shifts the deflection location to the new frame location during the interlude between frames, making multiple frame counts and locations possible. The final deflection circuit deflects to five different frame positions per axis, including the center position, making for a total of 25 frames. To create the preset voltages, electronically adjustable {+-}500 V power supplies were chosen. Digital-to-analog converters provide digital control of the supplies. The power supplies are clamped to {+-}400 V so as not to exceed the voltage ratings of the transistors. A field-programmable gated array (FPGA) receives the trigger signal and calculates the combination of plate voltages for each frame. The interframe time and number of frames are specified by the user, but are limited by the camera electronics. The variable-frame circuit shifts the plate voltages of the first frame to those of the second frame during the user-specified interframe time. Designed around an electrostatic image tube, a framing camera images the light present during each frame (at the photocathode) onto the tube’s phosphor. The phosphor persistence allows the camera to display multiple frames on the phosphor at one time. During this persistence, a CCD camera is triggered and the analog image is collected digitally. The tube functions by converting photons to electrons at the negatively charged photocathode. The electrons move quickly toward the more positive charge of the phosphor. Two sets of deflection plates skew the electron’s path in horizontal and vertical (x axis and y axis, respectively) directions. Hence, each frame’s electrons bombard the phosphor surface at a controlled location defined by the voltages on the deflection plates. To prevent the phosphor from being exposed between frames, the image tube is gated off between exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiparameter spatio-thermochemical probing of flame–wall interactions advanced with coherent Raman imaging

Ultrabroadband coherent anti-Stokes Ra man spectroscopy (CARS) has been developed for one -dimensional imaging of temperature and major species distributions simultaneously in the near-wall region of a methane/air flame supported on a side-wall-quenching (SWQ) burner. Automatic temporal and spatial overlap of the ~7 femtosecond pump and Stokes pulses is achieved utilizing a two-beam CARS phase-matching scheme, and the crossed ~75 picosecond probe beam provide s excellent spatial sectioning of the probed location. Concurrent detection of N 2 , O 2 , H 2 , CO, CO 2 , and CH 4 is demonstrated while high-fidelity flame thermometry is assessed from the N 2 pure rotational S-branch in a one-dimensional -CARS imaging configuration. A methane/air premixed flame at lean, stoichiometric, and rich conditions ( Φ = 0.83, 1.0 , and 1.2) and Reynolds number = 5,000 is probed as it quenches against a cooled steel side- wall parallel to the flow providing a persistent flame-wall interaction. Here, an imaging resolution of better than 40 μm is achieved across the field -of-view, thus allowing thermochemical states (temperature and major species) of the thermal boundary layer to be resolved to within ~30 μm of the interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RADIO ASTROMETRY OF THE TRIPLE SYSTEMS ALGOL AND UX ARIETIS

We have used multi-epoch long-baseline radio interferometry to determine the proper motion and orbital elements of Algol and UX Arietis, two radio-bright, close binary stellar systems with distant tertiary components. For Algol, we refine the proper motion and outer orbit solutions, confirming the recent result of Zavala et al. that the inner orbit is retrograde. The radio centroid closely tracks the motion of the KIV secondary. In addition, the radio morphology varies from double-lobed at low flux level to crescent-shaped during active periods. These results are most easily interpreted as synchrotron emission from a large, co-rotating meridional loop centered on the K star. If this is correct, it provides a radio-optical frame tie candidate with an uncertainty {+-}0.5 mas. For UX Arietis, we find an outer orbit solution that accounts for previous very long baseline interferometry observations of an acceleration term in the proper motion fit. The outer orbit solution is also consistent with previously published radial velocity curves and speckle observations of a third body. The derived tertiary mass, 0.75 solar masses, is consistent with the K1 main-sequence star detected spectroscopically. The inner orbit solution favors radio emission from the active K0IV primary only. The radio morphology, consisting of a single, partially resolved emission region, may be associated with the persistent polar spot observed using Doppler imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

How Excitation Conditions Alter the Afterglow Characteristics of CsI:Tl,Sm Microcolumnar Films

Combining high light output with the microcolumnar structure, the CsI:Tl films significantly reduce the need for painful tradeoff between thickness (hence, stopping power) and spatial resolution. But both films and monocrystals share two important deficiencies that hinder their use in many high-speed imaging and computed tomography applications: a persistent afterglow and hysteresis. These properties receive the primary attention of this investigation. In our earlier work, we reported that codoping with Sm 2+ brings about a significant reduction in the afterglow of CsI:Tl. Here, focusing on the microcolumnar films, we examine this afterglow-suppressive effect over a wide range of exposure times, from milliseconds to seconds, and at temperatures between 0 °C and 60 °C. Our measurements reveal well-defined dependences on both parameters. At room temperature (20 °C), defined as the normal operating condition, a 10-ms X-ray pulse leaves an afterglow from the standard (Sm-free) CsI:Tl of about 1% at 2 ms after the end of the pulse, changing little as a function of pulselength. Doping with Sm 2+ , however, reduces that afterglow by at least an order of magnitude, although somewhat less so after longer (100 and 1000 ms) pulses. When we change the temperature, however, we find markedly different behavior. Here, we find that a temperature increase of only 60°, without changing the pulselength, cuts the afterglow of standard CsI:Tl films by a factor of 20. However, films of codoped CsI:Tl,Sm, whose afterglow has already been suppressed by the presence of Sm 2+ , show much less change as a function of either temperature or pulse duration. It is the presence of Sm 2+ that makes the biggest difference. As for hysteresis, we again see an improvement, with the performance of the codoped CsI:Tl,Sm films bettering that of the standard (Sm-free) films. After an exposure of 300 mR, the change in light output falls to within 1% of the original after 1 min, whereas standard CsI:Tl films require 30 min to reach the same level.

42 ENGINEERING↗

Three-dimensional texture analysis of contrast enhanced CT images for treatment response assessment in Hodgkin lymphoma: Comparison with F-18-FDG PET

Purpose: To determine the diagnostic performance of three-dimensional (3D) texture analysis (TA) of contrast-enhanced computed tomography (CE-CT) images for treatment response assessment in patients with Hodgkin lymphoma (HL), compared with F-18-fludeoxyglucose (FDG) positron emission tomography/CT. Methods: 3D TA of 48 lymph nodes in 29 patients was performed on venous-phase CE-CT images before and after chemotherapy. All lymph nodes showed pathologically elevated FDG uptake at baseline. A stepwise logistic regression with forward selection was performed to identify classic CT parameters and texture features (TF) that enable the separation of complete response (CR) and persistent disease. Results: The TF fraction of image in runs, calculated for the 45° direction, was able to correctly identify CR with an accuracy of 75%, a sensitivity of 79.3%, and a specificity of 68.4%. Classical CT features achieved an accuracy of 75%, a sensitivity of 86.2%, and a specificity of 57.9%, whereas the combination of TF and CT imaging achieved an accuracy of 83.3%, a sensitivity of 86.2%, and a specificity of 78.9%. Conclusions: 3D TA of CE-CT images is potentially useful to identify nodal residual disease in HL, with a performance comparable to that of classical CT parameters. Best results are achieved when TA and classical CT features are combined.

60 APPLIED LIFE SCIENCES↗

The Essentials of Parathyroid Hormone Venous Sampling

Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage. Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Individual Barium Atoms in Solid Xenon for Barium Tagging in nEXO

The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or “tagging”, of the 136Ba daughter atom from double beta decay of 136Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for ~30 s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of =0.16%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.

Chambers, C↗

Hubble space telescope imaging of decoupled dust clouds in the ram pressure stripped Virgo spirals NGC 4402 and NGC 4522

We present the highest-resolution study to date of the interstellar medium (ISM) in galaxies undergoing ram pressure stripping, using Hubble Space Telescope BVI imaging of NGC 4522 and NGC 4402, Virgo Cluster spirals that are well known to be experiencing intracluster medium (ICM) ram pressure. We find that throughout most of both galaxies, the main dust lane has a fairly well-defined edge, with a population of giant molecular cloud (GMC) sized (tens- to hundreds-of-pc scale), isolated, highly extincting dust clouds located up to ∼1.5 kpc radially beyond it. Outside of these dense clouds, the area has little or no diffuse dust extinction, indicating that the clouds have decoupled from the lower-density ISM material that has already been stripped. Several of the dust clouds have elongated morphologies that indicate active ram pressure, including two large (kpc scale) filaments in NGC 4402 that are elongated in the projected ICM wind direction. We calculate a lower limit on the H I + H{sub 2} masses of these clouds based on their dust extinctions and find that a correction factor of ∼10 gives cloud masses consistent with those measured in CO for clouds of similar diameters, probably due to the complicating factors of foreground light, cloud substructure, and resolution limitations. Assuming that the clouds' actual masses are consistent with those of GMCs of similar diameters (∼10{sup 4}-10{sup 5} M {sub ☉}), we estimate that only a small fraction (∼1%-10%) of the original H I + H{sub 2} remains in the parts of the disks with decoupled clouds. Based on Hα images, a similar fraction of star formation persists in these regions, 2%-3% of the estimated pre-stripping star formation rate. We find that the decoupled cloud lifetimes may be up to 150-200 Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

Expansion dynamics of ultrafast laser produced plasmas in the presence of ambient argon

In this paper, we report the emission features of fs laser ablated brass plasma plumes at various Ar background pressure levels ranging from vacuum to atmospheric conditions. Spectrally integrated 2D-imaging of plasma self-emission showed several interesting features at various pressure levels which consists of plume morphological changes, increase in persistence, confinement, and internal structures. Spatially resolved wavelength dispersed images of the plume were recorded for characterizing the spectral features at various pressure levels and also used for obtaining spatial distribution of Cu I and Zn I species in the plume, signal to noise ratios and fundamental parameters of the plasma; viz. temperature and density. The spatial evolution of excitation temperature and density showed significant changes at various ambient pressure levels and these results were correlated to morphological changes seen in the plume images. Optimum signal to background ratios for emission lines were observed in the moderate pressure range (~ 1-10 Torr). Optical time-of-flight profiles were used to study time evolution of various species in the plume and noticed oscillations at intermediate pressure levels. Possible mechanisms for observed changes in plume shape, optical emission intensity, and dual peak structures in time-of-flight profiles were discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging Axl expression in pancreatic and prostate cancer xenografts

Highlights: •Axl is overexpressed in a variety of cancers. •Axl overexpression confers invasive phenotype. •Axl imaging would be useful for therapeutic guidance and monitoring. •Axl expression imaging is demonstrated in pancreatic and prostate cancer xenografts. •Graded levels of Axl expression imaging is feasible. -- Abstract: The receptor tyrosine kinase Axl is overexpressed in and leads to patient morbidity and mortality in a variety of cancers. Axl–Gas6 interactions are critical for tumor growth, angiogenesis and metastasis. The goal of this study was to investigate the feasibility of imaging graded levels of Axl expression in tumors using a radiolabeled antibody. We radiolabeled anti-human Axl (Axl mAb) and control IgG1 antibodies with {sup 125}I with high specific radioactivity and radiochemical purity, resulting in an immunoreactive fraction suitable for in vivo studies. Radiolabeled antibodies were investigated in severe combined immunodeficient mice harboring subcutaneous CFPAC (Axl{sup high}) and Panc1 (Axl{sup low}) pancreatic cancer xenografts by ex vivo biodistribution and imaging. Based on these results, the specificity of [{sup 125}I]Axl mAb was also validated in mice harboring orthotopic Panc1 or CFPAC tumors and in mice harboring subcutaneous 22Rv1 (Axl{sup low}) or DU145 (Axl{sup high}) prostate tumors by ex vivo biodistribution and imaging studies at 72 h post-injection of the antibody. Both imaging and biodistribution studies demonstrated specific and persistent accumulation of [{sup 125}I]Axl mAb in Axl{sup high} (CFPAC and DU145) expression tumors compared to the Axl{sup low} (Panc1 and 22Rv1) expression tumors. Axl expression in these tumors was further confirmed by immunohistochemical studies. No difference in the uptake of radioactivity was observed between the control [{sup 125}I]IgG1 antibody in the Axl{sup high} and Axl{sup low} expression tumors. These data demonstrate the feasibility of imaging Axl expression in pancreatic and prostate tumor xenografts.

60 APPLIED LIFE SCIENCES↗

Correlations of Cu(In, Ga)Se2 Imaging with Device Performance, Defects, and Microstructural Properties

Camera imaging techniques have been used for the characterization of Cu(In,Ga)Se{sub 2} (CIGS) solar cells. Photoluminescence (PL) imaging shows brightness variations after the deposition of the CIGS layer that persist through CdS deposition and subsequent processing steps to finish the devices. PL and electroluminescence imaging on finished cells show a correlation to the devices corresponding efficiency and open-circuit voltage (V{sub OC}), and dark defect-related spots correspond to bright spots on images from illuminated lock-in thermography (LIT) and forward-bias dark LIT. These image-detected defect areas are weak diodes and shunts. Imaging provides locations of defects detrimental to solar cell performance. Some of these defects are analyzed in more detail by scanning electron microscopy using cross-sectional views.

14 SOLAR ENERGY↗

THEORY AND SIMULATIONS OF REFRACTIVE SUBSTRUCTURE IN RESOLVED SCATTER-BROADENED IMAGES

At radio wavelengths, scattering in the interstellar medium distorts the appearance of astronomical sources. Averaged over a scattering ensemble, the result is a blurred image of the source. However, Narayan and Goodman and Goodman and Narayan showed that for an incomplete average, scattering introduces refractive substructure in the image of a point source that is both persistent and wideband. We show that this substructure is quenched but not smoothed by an extended source. As a result, when the scatter-broadening is comparable to or exceeds the unscattered source size, the scattering can introduce spurious compact features into images. In addition, we derive efficient strategies to numerically compute realistic scattered images, and we present characteristic examples from simulations. Our results show that refractive substructure is an important consideration for ongoing missions at the highest angular resolutions, and we discuss specific implications for RadioAstron and the Event Horizon Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

The Host Galaxy and Redshift of the Repeating Fast Radio Burst FRB 121102

The precise localization of the repeating fast radio burst (FRB 121102) has provided the first unambiguous association (chance coincidence probability p ≲ 3 × 10{sup −4}) of an FRB with an optical and persistent radio counterpart. We report on optical imaging and spectroscopy of the counterpart and find that it is an extended (0.″6–0.″8) object displaying prominent Balmer and [O iii] emission lines. Based on the spectrum and emission line ratios, we classify the counterpart as a low-metallicity, star-forming, m{sub r′} = 25.1 AB mag dwarf galaxy at a redshift of z = 0.19273(8), corresponding to a luminosity distance of 972 Mpc. From the angular size, the redshift, and luminosity, we estimate the host galaxy to have a diameter ≲4 kpc and a stellar mass of M {sub *} ∼ (4–7) × 10{sup 7} M {sub ⊙}, assuming a mass-to-light ratio between 2 to 3 M {sub ⊙} L {sub ⊙} {sup −1}. Based on the H α flux, we estimate the star formation rate of the host to be 0.4 M {sub ⊙} yr{sup −1} and a substantial host dispersion measure (DM) depth ≲324 pc cm{sup −3}. The net DM contribution of the host galaxy to FRB 121102 is likely to be lower than this value depending on geometrical factors. We show that the persistent radio source at FRB 121102’s location reported by Marcote et al. is offset from the galaxy’s center of light by ∼200 mas and the host galaxy does not show optical signatures for AGN activity. If FRB 121102 is typical of the wider FRB population and if future interferometric localizations preferentially find them in dwarf galaxies with low metallicities and prominent emission lines, they would share such a preference with long gamma-ray bursts and superluminous supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗