Search NASA⌕ Search

SEARCH · Search NASA

Results for “phased change material (PCM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Thermal Conductivity of a Novel Salt-Hydrogel Complex as a Phase Change Material for Building Thermal Management

Use of electricity for space heating, ventilation and air conditioning in buildings may be better managed through temporary energy storage. Compared with electrochemical storage, the levelized cost of thermal energy storage systems can be lower depending on geographical location and thermophysical properties [1]. In any phase change material (PCM), the rate of absorption and release of thermal energy increases with higher thermal conductivity [2]. However, leading PCMs like paraffin waxes have thermal conductivities on the order of 0.1 W/mK. Glauber’s salt, a salt hydrate, possesses a relatively high thermal conductivity but suffers from supercooling and phase segregation. Research has shown that polymer-based composites with salt hydrates can prevent phase segregation and limit supercooling over hundreds of cycles [3] though the thermal conductivity of the composite may be reduced leading to low energy storage rates. Here, we report thermal conductivity measurements on polymer hydrogels which are stable in solutions of Glauber’s salt. To measure thermal conductivity of soft gels, we use a 3-omega method [4] where heat flows bidirectionally through a substrate below and through a gel placed on top. This suits measurements of both gels and liquids unlike transient plane heat source or transient hot wire methods. We report measurements of thermal conductivity of salt-hydrogel complexes as a function of temperature, cross-linking and salt concentration. In addition, we present modeling of thermal conductivity of sodium sulfate solutions with available theories. We finally employ polarized optical microscopy to observe inside the transparent hydrogel networks, showing that precipitating crystals may influence thermal conductivity measurements for high salt concentrations. Our thermal conductivity results combined with enthalpy of phase change, mass density and specific heat are essential to accurately design thermal storage systems for energy-efficient buildings.

composite, thermal conductivity↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Community Resilience through Low-Temperature Geothermal Reservoir Thermal Energy Storage

Submitted data include simulations related to underground thermal battery (UTB) simulations described in Modeling and efficiency study of large scale underground thermal battery deployment, presented at GRC, October 2021. The UTB is comprised of a tank of water, a helical heat exchanger in the center of tank and connected to a water source heat pump, and a phase change material (PCM). Compared to a conventional VBGHE, the UTB is designed to be installed at a much shallower depth, therefore, with a cheaper cost. In addition, the GSHP efficiency is improved due to natural convection of water and additional load capacity provided by PCM. The goal of this study is to explore factors that may affect the efficiency of large-scale UTB deployment. The simulations found in this submission relate to the report on UTB deployment.

15 GEOTHERMAL ENERGY↗

Enhanced thermal reliability and performance of calcium chloride hexahydrate phase change material using cellulose nanofibril and graphene nanoplatelet

In recent years, thermal energy storage (TES) has gained attention for its role in enhancing renewable energy solutions and sustainable energy consumption. The usage of strontium chloride hexahydrate (SCH), graphene nanoplatelet (GNP), and cellulose nanofibril (CNF) additives were investigated to enhance the performance of calcium chloride hexahydrate (CCH) based on the melting/solidification behavior for TES applications. In this work, we develop a promising phase-change-material (PCM) formulation by introducing these additives that reduce supercooling, improve the thermal conductivity and stabilizing the energy storage capacity of CCH. Rheological characterizations demonstrated that the addition of 1 wt% of CNF into CCH produced the required improvement in viscosity and boosted solid-like rheological behavior. Structural characterizations show a physical mixing of the materials within the PCM composites. Our observations show that the amphiphilicity of CNF enables the surface attachment to GNP via hydrophobic interactions providing effective dispersion of GNP throughout the PCM composite. The addition of a nucleating agent, SCH decreased the degree of supercooling of ~20 g of CCH from >20 °C to 3 °C at a cooling rate of 5 °C/min. Thermal characterization showed the resulting PCM composite has a latent heat of melting of 186 Jg -1 , phase change temperature of 32 °C, and stable thermal properties after being subjected to 70 melt-freeze cycles. Adding CNF and GNP to pure CCH increased its thermal conductivity by 76 %. The high thermal conductivity of GNP and its effective dispersion by CNF is responsible for this enhancement. The study highlights the use of biodegradable nanocellulose for the preparation of sustainable PCM composites with improved performance. In conclusion, these PCM composites are scalable, they have potential to increase energy efficiency and revolutionalize the heating/cooling applications in buildings and other TES systems.

25 ENERGY STORAGE↗

Energy Demand Management in Buildings Using PCM-Integrated Wall

The buildings in the United States annually consume nearly 40% of total U.S. energy consumption and approximately 75% of U.S. electricity consumption. Almost half of the total U.S. energy consumption in buildings is attributed to the space conditioning through Heating, Ventilation, and Air Conditioning (HVAC) systems. Utilizing thermal energy storage in buildings, particularly integrating phase change material (PCM) in the walls, has been reported to be an effective method of managing the space heating and cooling loads. This presentation covers an in-depth discussion on the integration of a PCM to building walls, the key conditions required for effective utilization of the PCM, and effect of the PCM transition temperature and the PCM location on energy-saving potential of the PCM-integrated wall.

building↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Evaluation of Effective Thermal Conductivity of PCM with Metal Foam Incorporating Buoyancy Effects for Thermal Energy Storage

The thermal energy storage (TES) system has the capability to efficiently preserve thermal energy directly derived from the energy source, minimizing any conversion losses. Especially latent heat storage offers distinct advantages, including a substantial increase in energy storage density and minimization of temperature fluctuations within the plants. However, the phase change material (PCM) employed in latent heat storage has low thermal conductivity. Consequently, various studies are being conducted to enhance heat transfer. One approach to enhance heat transfer involves utilizing metal foam to maximize the heat transfer area. However, modeling metal foam with its intricate structure is a challenging task in numerical analysis. For this reason, ongoing research focuses on simplifying the modeling of metal foam. Nevertheless, fully encompassing all the characteristics of actual metal foam proves to be a challenging task for the simplified analytical model. The objective of this paper is to interpret the simple lattice metal foam analysis model from the perspective of behavior induced by buoyancy. When comparing the analysis results of solid PCM and liquid PCM with the same thermal conductivity under changes in porosity and gravity direction, we conducted an analysis to discern the trends in effective thermal conductivity that are overestimated due to convection. In the analysis, a constant heat flux of 10 kW and a constant surface boundary condition of 350 K were applied, and a sensitivity study regarding the mesh was conducted. The results indicate that, from the perspective of gravity in the simple lattice model, the solid analysis yields an effective thermal conductivity 29-47% higher compared to the liquid analysis. Additionally, as porosity increases, there is an observed increase of 24-33% in effective thermal conductivity.

25 ENERGY STORAGE↗

MODELING AND OPTIMIZATION OF A PCM-BASED OCEAN THERMAL ENERGY HARVESTER FOR POWERING UNMANNED UNDERWATER VEHICLES

As oceans cover over 70% of the planet’s surface, they represent a large reservoir of resources that remained vastly untapped. Uncrewed Underwater Vehicles (UUVs) are becoming key technology for ocean exploration. Ocean thermal gradient is a permanent and reliable energy source that can be used to power UUVs using phase change material (PCM)-based thermal engines. However, the main drawback of this technology is its low conversion efficiency. When using PCM-based thermal engines to power UUVs, there are different energy conversion stages, thermal-hydraulic, hydraulic-kinetic, kinetic-electrical, dependent of a wide variety of parameters. Thus, optimization of the overall energy conversion is still a challenge for powering the increasing energy demanding UUVs for long missions. The goal of this study is to propose a PCM-based ocean thermal energy harvesting system for powering the Solo II float. Using the ocean thermal energy reduces the cost for battery replacement and expands the float’s mission time. For this purpose, we developed a multiphysics model for a system consisting of thermal material, hydraulic, and electrical systems. This system is designed to provide the electrical power needed for the instruments aboard the underwater vehicle. The models of the hydraulic and the electric systems are implemented in MATLAB-Simulink/Simscape environment. The final model developed can provide 13.66 kJ of electrical energy, which is more than 1.5 times the energy requirement per cycle for the SOLO II float.

Ouro-Koura, Habilou↗

Extracting energy from ocean thermal and salinity gradients to power unmanned underwater vehicles: State of the art, current limitations, and future outlook

Thermal gradient energy-generation technologies for powering unmanned underwater vehicles (UUVs) or autonomous sensing systems in the ocean are mainly in the research development phase or commercially available at a limited scale, and salinity-gradient energy-generation technologies have not been adequately researched yet. The demand for self-powered UUVs suitable for long-term deployments has been growing, and further research related to small-scale ocean gradient energy systems is needed. In this study, we conducted a comprehensive review about harvesting energy from ocean thermal or salinity gradients for powering UUVs, focusing on gliders and profiling floats. Thermal gradient energy systems for UUVs based on phase change materials (PCM) cannot provide the energy required for powering autonomous sensing systems because of the systems' low energy conversion efficiency. Besides reducing energy consumption by developing more efficient electrical-mechanical systems, enhancing the thermal conductivity of the PCMs may help address this challenge by increasing the power generation rate of the UUVs. Several other emerging technologies, such as thermoelectric generators, shape memory alloys, and small-scale thermodynamic cycle systems, have shown potential for powering UUVs, but they are still only at the laboratory testing or conceptual design phase. The most advanced power generation technologies based on salinity gradients, reverse electrodialysis and pressure-retarded osmosis, are still not economically viable for large-scale deployment, mainly because of the high cost of the components required to operate in harsh saline environments. Our feasibility evaluation showed that existing salinity gradient power generation technologies are not directly feasible for powering UUVs in the open ocean.

16 TIDAL AND WAVE POWER↗

Experimental Evaluation of Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery

A geothermal heat pump (GHP) system is an energy-efficient building heating and cooling technology with great potential for reducing energy consumption and decarbonization. However, applications of GHP are still limited due to the high cost, of which 30% is related to the cost of installing the conventional vertical bore ground heat exchangers, which are usually installed in boreholes 60 meters deep. A dual-purpose underground thermal battery (DPUTB) has been developed to offer a low-cost ground heat exchanger with a built-in thermal storage capacity. The DPUTB innovatively integrates a shallow-bore ground heat exchanger (the outer tank), which can be installed in a borehole less than 6 m deep, with thermal energy storage (TES) (the inner tank). DPUTB has the potential to reduce the cost of a ground source heat pump system while allowing shifting the electric demand of the building served by the GHP system from peak to off-peak hours of the electric grid by charging and discharging the thermal storage. A lab-scale (1:125 in volume) DPUTB prototype was built. Phase change material (PCM) was added to increase the thermal storage capacity and maintain the supply water temperature from the TES within the desired range for direct cooling operation during the discharge period. As PCMs are critical to the TES performance of the DPUTB, this study compared the influence of different PCMs (including salt hydrate and organic PCMs) on the discharge performance of the DPUTB. The thermal State of Charge (SoC) of the DPUTB was used to compare the performance resulting from using different PCMs. Test results indicate that the organic PCM (Methyl Laurate) outperforms salt-hydrate PCMs due to a lower melting temperature and a narrower melting temperature range during the phase change process. The results of this study provide a guide for PCM selection and the optimal design of DPUTB.

Wang, Lingshi↗

Phase change material integrated core–shell catalyst for in situ thermal control in methanol synthesis from syngas

A model-guided core–shell catalyst design is presented for methanol synthesis, featuring a phase change material (PCM) core encapsulated by a Cu–Zn–Al 2 O 3 (CZA) catalytic shell. The PCM enables in situ thermal management by absorbing reaction heat at its melting point, mitigates the kinetic decline at high temperatures and therefore avoids low conversion, prevents hot spots, and stabilizes the reaction temperature. A two-dimensional axisymmetric, non-isothermal packed-bed reactor model (COMSOL 6.3) was developed for a 10 g system. Simulations evaluate three PCM candidates, that is, LiNO 3 , 9 wt% LiCl + 91 wt% LiNO 3 , and commercial H250, with melting points near 244–250°C. Results indicate that CO conversion can increase from 34.4% to 52.4%, and methanol production can improve by 69% compared to a conventional packed-bed reactor. Beyond methanol synthesis, the PCM-integrated core–shell concept provides a scalable approach for thermal control in exothermic reactions, improving reactor efficiency and safety.

core–shell catalyst↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Cost-Effective Thermally Activated Building Systems to Support a Power Grid System With High Penetrations Of As-Available Renewable Energy Resources

With a goal to reduce the energy cost for building operation as well as to support renewable energy sources (RES) for the power grid reliability, quality, resilience, and dispatchability, this project developed and demonstrated a novel thermally activated building envelope system that integrates Phase Change Material (PCM)-based Thermal Energy Storage (TES) and the hydronic activation into the building envelope. The main objectives of this study are: 1) to design and laboraorty-test a novel thermally activated building envelope system that integrate PCM-based TES and the hydronic activation into building envelope, and 2) to exploit this new system to significantly reduce the energy cost of operating buildings and manage and support renewable energy sources (RES), e.g., solar and wind for the power grid reliability, quality, resilience, and dispatchability. To achieve the project objectives, a new low-cost, fire-retardant PCM packaging technology (CenoPCM) was developed specifically for high-volume building applications.

25 ENERGY STORAGE↗

Building energy efficiency and load flexibility optimization using phase change materials under futuristic grid scenario

This work investigates the energy savings and load flexibility capacity of phase change material (PCM) integrated into building envelope under a future energy generation scenario, where 80% of the energy load comes from renewable sources. Using community-scale modeling, we first determine the net thermal storage required to fully manage the demand variability at a utility grid, and then using whole-building simulations we optimize operating parameters - such as PCM thickness, latent heat, interior setpoint profile, PCM distribution, and heat transfer coefficient - to determine the optimal conditions required for maximum energy reduction and load flexibility without compromising occupants' thermal comfort. The optimal PCM-integrated envelope proposed in this study can provide annual load flexibility up to 33.6% and annual energy savings up to 10.8% in a lightweight residential building located in Baltimore, MD. This study is relevant given the increasing contributions of renewable energy in the total energy generation mix, leading to a significant time-imbalance between peak energy demand and peak energy production. While thermal energy storage using PCM is a recognized technique, there is no known prior study dedicated to examining the thermal performance of PCM-integrated envelope under future energy generation scenarios. This study bridges the research gap by investigating a practical way to implement PCMs in the buildings and maximize the energy efficiency as well as load flexibility related benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗