Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon and dimensional efficiencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Nonclassical light from finite-range interactions in a two-dimensional quantum mirror

Excitons in a semiconductor monolayer form a collective resonance that can reflect resonant light with extraordinarily high efficiency. We investigate the nonlinear optical properties of such atomistically thin mirrors and show that finite-range interactions between excitons can lead to the generation of highly nonclassical light. We describe two scenarios, in which optical nonlinearities arise either from direct photon coupling to excitons in excited Rydberg states or from resonant two-photon excitation of Rydberg excitons with finite-range interactions. The latter case yields conditions of electromagnetically induced transparency and thereby provides an efficient mechanism for single-photon switching between high transmission and reflectance of the monolayer, with a tunable dynamical timescale of the emerging photon-photon interactions. Remarkably, it turns out that the resulting high degree of photon correlations remains virtually unaffected by Rydberg-state decoherence, in excess of nonradiative decoherence observed for ground-state excitons in two-dimensional semiconductors. This robustness to imperfections suggests a promising approach to quantum photonics at the level of individual photons.

36 MATERIALS SCIENCE↗

Two-Photon Fluorescence Microscopy Developed for Microgravity Fluid Physics

Recent research efforts within the Microgravity Fluid Physics Branch of the NASA Glenn Research Center have necessitated the development of a microscope capable of high-resolution, three-dimensional imaging of intracellular structure and tissue morphology. Standard optical microscopy works well for thin samples, but it does not allow the imaging of thick samples because of severe degradation caused by out-of-focus object structure. Confocal microscopy, which is a laser-based scanning microscopy, provides improved three-dimensional imaging and true optical sectioning by excluding the out-of-focus light. However, in confocal microscopy, out-of-focus object structure is still illuminated by the incoming beam, which can lead to substantial photo-bleaching. In addition, confocal microscopy is plagued by limited penetration depth, signal loss due to the presence of a confocal pinhole, and the possibility of live-cell damage. Two-photon microscopy is a novel form of laser-based scanning microscopy that allows three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon microscopy, it utilizes the nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption because of the nonlinear (i.e., quadratic) electric field dependence, so an ultrafast pulsed laser source must typically be employed. On the other hand, this stringent energy density requirement effectively localizes fluorophore excitation to the focal volume. Consequently, two-photon microscopy provides optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction in photo-damage because of the longer excitation wavelength, a reduction in background fluorescence, and a 4 increase in penetration depth over confocal methods because of the reduction in Rayleigh scattering.

Fischer, David G.↗

3D-Printed Repeating Re-Entrant Topography to Achieve On-Demand Wettability and Separation

While it is difficult and expensive to fabricate a complicated surface structure via conventional techniques, three-dimensional (3D) printing serves as a time-efficient and cost-efficient alternative. In the current study, a novel repeating re-entrant topography is fabricated by two-photon polymerization 3D printing. The experimental results show that the repeating re-entrant surface enhances the desired on-demand surface wettability. Furthermore, the 3D-printed membranes with the repeating re-entrant structures enable the efficient on-demand separation of liquid mixtures with high flux, which is critical for the wastewater treatment in the chemical industry.

36 MATERIALS SCIENCE↗

Spatio-spectral quantum state estimation of photon pairs from optical fiber using stimulated emission

Developing a quantum light source that carries more than one bit per photon is pivotal for expanding quantum information applications. Characterizing a high-dimensional multiple-degree-of-freedom source at the single-photon level is challenging due to the large parameter space as well as limited emission rates and detection efficiencies. Here, we characterize photon pairs generated in optical fiber in the transverse-mode and frequency degrees of freedom by applying stimulated emission in both degrees of freedom while detecting in one of them at a time. This method may be useful in the quantum state estimation and optimization of various photon-pair source platforms in which complicated correlations across multiple degrees of freedom may be present.

Kim, Dong Beom (ORCID:0000000346887375)↗

Strain-engineered high-responsivity MoTe 2 photodetector for silicon photonic integrated circuits

In integrated photonics, specific wavelengths are preferred such as 1550 nm due to low-loss transmission and the availability of optical gain in this spectral region. For chip-based photodetectors, layered two-dimensional (2D) materials bear scientific and technologically relevant properties such as electrostatic tunability and strong light-matter interactions. However, no efficient photodetector in the telecommunication C-band has been realized with 2D transition metal dichalcogenide materials due to their large optical bandgap. Furthermore, we demonstrate a MoTe 2 -based photodetector featuring strong photoresponse (responsivity = 0.5 A/W -1 ) operating at 1550 nm in silicon photonics enabled by strain engineering the 2D material. Non-planarized waveguide structures show a locally-induced bandgap change of 0.2 eV inside MoTe 2 , resulting in large photo-response, in an otherwise photo-inactive medium when unstrained. Unlike Graphene-based photodetectors relying on a gapless band structure, this photodetector shows a ~100X improved dark current, enabling an efficient noise equivalent power of 90 pW/Hz -0.5 . Such strain-engineered integrated photodetector provides new opportunities for integrated optoelectronic systems.

47 OTHER INSTRUMENTATION↗

Femtosecond photoemission electron microscopy of surface plasmon polariton beam steering via nanohole arrays

Directional control over surface plasmon polariton (SPP) waves is a prerequisite for the development of miniaturized optical circuitry. Here, the efficacy of single and dual component SPP steering elements is explored through photoemission electron microscopy. Our imaging scheme relies on two-color photoemission and counter-propagating SPP generation, which collectively allow SPPs to be visualized in real space. Wave-vector difference mixing between two-dimensional arrays of nanoholes and photon momenta enables SPP steering with directionality governed by the array lattice constant. The magnitude of grating momentum required to achieve counter-propagation guarantees efficient steering over the full range of the negative half-space. In our dual component configuration, separate SPP generation and Bragg diffraction based steering optics are employed. We find that array Bragg planes principally influence the SPP angles through the array band structure, which allows us to visualize both positive and negative refractory waves.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High resolution, two-dimensional imaging, microchannel plate detector for use on a sounding rocket experiment

We discuss a high resolution microchannel plate (MCP) imaging detector to be used in measurements of Doppler-shifted hydrogen Lyman-alpha line emission from Jupiter and the interplanetary medium. The detector is housed in a vacuum-tight stainless steel cylinder (to provide shielding from magnetic fields) with a MgF2 window. Operating at nominal voltage, the four plate configuration provides a gain of 1.2 x 10 exp 7 electrons per incident photon. The wedge-and-strip anode has two-dimensional imaging capabilities, with a resolution of 40 microns FWHM over a one centimeter diameter area. The detector has a high quantum efficiency while retaining a low background rate. A KBr photocathode is used to enhance the quantum efficiency of the bare MCPs to a value of 35 percent at Lyman-alpha.

Bush, Brett C.↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Towards the Quantum Internet: Entanglement Rate Analysis of High-Efficiency Electro-Optic Transducer

Coherent microwave-optical photon conversion is a key enabling technology for the Quantum Internet, since it allows entanglement distribution among superconducting-based network nodes. A high-efficiency electro-optic transducer based on three-dimensional superconducting radio-frequency (SRF) technology has recently been proposed at Fermilab. In this paper, we evaluate the impact of Fermilab's transduction hardware on the entanglement generation probability and the entanglement rate, which are two critical metrics from a communication engineering perspective. Furthermore, we provide some guidelines to increase the direct entanglement rate, i.e., the rate before any entanglement purification process. Our analysis shows that, through high-efficiency transduction, it is possible to reduce the network overhead. This preliminary work paves the way toward distantly interconnected superconducting quantum processors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Empowering a qudit-based quantum processor by traversing the dual bosonic ladder

Abstract High-dimensional quantum information processing has emerged as a promising avenue to transcend hardware limitations and advance the frontiers of quantum technologies. Harnessing the untapped potential of the so-called qudits necessitates the development of quantum protocols beyond the established qubit methodologies. Here, we present a robust, hardware-efficient, and scalable approach for operating multidimensional solid-state systems using Raman-assisted two-photon interactions. We then utilize them to construct extensible multi-qubit operations, realize highly entangled multidimensional states including atomic squeezed states and Schrödinger cat states, and implement programmable entanglement distribution along a qudit array. Our work illuminates the quantum electrodynamics of strongly driven multi-qudit systems and provides the experimental foundation for the future development of high-dimensional quantum applications such as quantum sensing and fault-tolerant quantum computing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid Quantum Vision Transformers for Event Classification in High Energy Physics

Models based on vision transformer architectures are considered state-of-the-art when it comes to image classification tasks. However, they require extensive computational resources both for training and deployment. The problem is exacerbated as the amount and complexity of the data increases. Quantum-based vision transformer models could potentially alleviate this issue by reducing the training and operating time while maintaining the same predictive power. Although current quantum computers are not yet able to perform high-dimensional tasks, they do offer one of the most efficient solutions for the future. In this work, we construct several variations of a quantum hybrid vision transformer for a classification problem in high-energy physics (distinguishing photons and electrons in the electromagnetic calorimeter). We test them against classical vision transformer architectures. Our findings indicate that the hybrid models can achieve comparable performance to their classical analogs with a similar number of parameters.

Unlu, Eyup B. (ORCID:0000000266836463)↗

Feasibility study of transit photon correlation anemometer for Ames Research Center unitary wind tunnel plan

A laser transit anemometer measured a two-dimensional vector velocity, using the transit time of scattering particles between two focused and parallel laser beams. The objectives were: (1) the determination of the concentration levels and light scattering efficiencies of naturally occurring, submicron particles in the NASA/Ames unitary wind tunnel and (2) the evaluation based on these measured data of a laser transit anemometer with digital correlation processing for nonintrusive velocity measurement in this facility. The evaluation criteria were the speeds at which point velocity measurements could be realized with this technique (as determined from computer simulations) for given accuracy requirements.

Mayo, W. T., Jr.↗

Sensor Distortion Effects in Photon Monte Carlo Simulations

We present a detailed method to simulating sensor distortions using a photon and electron Monte Carlo method. We use three-dimensional electrostatic simulations to parameterize the perturbed electric field profile for nonideal sensor details. We follow the conversion of simulated photons, and the subsequent response of the converted electrons to the electric field pattern. These nonideal sensor details can be implemented efficiently in a Monte Carlo approach. We demonstrate that the nonideal sensor distortions have a variety of observable consequence including the modification of the astrometric pattern; the distortion of the electron diffusion size and shape; and the distortion of flats. We show analytic validation of the diffusion physics, reproduce two kinds of edge distortion, and show qualitative validation of field-free regions, lithography errors, and fringing. We also demonstrate that there are two related effects of doping variation having different observable consequences. We show that field distortions from accumulated electrons lead to intensity-dependent point-spread functions and the sublinear variance in flats. The method is implemented in the Photon Simulator and the code is publicly available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-chip optical tweezers based on freeform optics

Since its advent in the 1970s, optical tweezers have been widely deployed as a preferred non-contact technique for manipulating microscale objects. On-chip integrated optical tweezers, which afford significant size, weight, and cost benefits, have been implemented, relying upon near-field evanescent waves. As a result, these tweezers are only capable of manipulation in near-surface regions and often demand high power since the evanescent interactions are relatively weak. We introduce on-chip optical tweezers based on freeform micro-optics, which comprise optical reflectors or refractive lenses integrated on waveguide end facets via two-photon polymerization. The freeform optical design offers unprecedented degrees of freedom to design optical fields with strong three-dimensional intensity gradients, useful for trapping and manipulating suspended particles in an integrated chip-scale platform. We demonstrate the design, fabrication, and measurement of both reflective and refractive micro-optical tweezers. The reflective tweezers feature a remarkably low trapping threshold power, and the refractive tweezers are particularly useful for multiparticle trapping and interparticle interaction analysis. Our integrated micro-optical tweezers uniquely combine a compact footprint, broadband operation, high trapping efficiency, and scalable integration with planar photonic circuits. This class of tweezers is promising for on-chip sensing, cell assembly, particle dynamics analysis, and ion trapping.

Yu, Shaoliang (ORCID:000000026072425X)↗

Video-rate Raman-based metabolic imaging by Airy light-sheet illumination and photon-sparse detection

Despite its massive potential, Raman imaging represents just a modest fraction of all research and clinical microscopy to date. This is due to the ultralow Raman scattering cross-sections of most biomolecules that impose low-light or photon-sparse conditions. Bioimaging under such conditions is suboptimal, as it either results in ultralow frame rates or requires increased levels of irradiance. Here, we overcome this tradeoff by introducing Raman imaging that operates at both video rates and 1,000-fold lower irradiance than state-of-the-art methods. To accomplish this, we deployed a judicially designed Airy light-sheet microscope to efficiently image large specimen regions. Further, we implemented subphoton per pixel image acquisition and reconstruction to confront issues arising from photon sparsity at just millisecond integrations. We demonstrate the versatility of our approach by imaging a variety of samples, including the three-dimensional (3D) metabolic activity of single microbial cells and the underlying cell-to-cell variability. To image such small-scale targets, we again harnessed photon sparsity to increase magnification without a field-of-view penalty, thus, overcoming another key limitation in modern light-sheet microscopy.

60 APPLIED LIFE SCIENCES↗

Catalytic resonance theory for the kinetic signatures of multiple wavelength photocatalysis

Multi-step surface chemistry promoted with one or two wavelengths of light exhibited distinct kinetic signatures indicative of the light-adsorbate interactions and the number of photon-sensitive elementary steps. In this work, kinetic Monte Carlo simulations identified the kinetic response of general surface mechanisms to variation in the per-site photon flux of one or two wavelengths of incident light. Photocatalytic rates were described via a non-dimensional photon flux, identifying multiple kinetic regimes with unique degrees of rate control. Under photon-controlled kinetic conditions, maximum quantum yield and turnover frequency were obtained under constant illumination, while pulsing of one or more light sources was shown to exhibit slower rates and less efficient photocatalytic promotion due to the inherent dynamic nature of light, which comprises a stream of photons. Simulations provided distinct kinetic signatures in catalytic rates and Arrhenius kinetics for specific light-surface-adsorbate interactions corresponding to photocatalytic promotion of specific steps in surface chemistry.

catalytic resonance↗

Doping-driven topological polaritons in graphene/$\alpha$-MoO 3 heterostructures

Control over charge carrier density provides an efficient way to trigger phase transitions and modulate the optoelectronic properties of materials. This approach can also be used to induce topological transitions in the optical response of photonic systems. Here we report a topological transition in the isofrequency dispersion contours of hybrid polaritons supported by a two-dimensional heterostructure consisting of graphene and α-phase molybdenum trioxide. By chemically changing the doping level of graphene, we observed that the topology of polariton isofrequency surfaces transforms from open to closed shapes as a result of doping-dependent polariton hybridization. Moreover, when the substrate was changed, the dispersion contour became dominated by flat profiles at the topological transition, thus supporting tunable diffractionless polariton propagation and providing local control over the optical contour topology. We achieved subwavelength focusing of polaritons down to 4.8% of the free-space light wavelength by using a 1.5-μm-wide silica substrate as an in-plane lens. Our findings could lead to on-chip applications in nanoimaging, optical sensing and manipulation of energy transfer at the nanoscale.

36 MATERIALS SCIENCE↗

Ultralow-Background Large-Format Bolometer Arrays

In the coming decade, work will commence in earnest on large cryogenic far-infrared telescopes and interferometers. All such observatories - for example, SAFIR, SPIRIT, and SPECS - require large format, two dimensional arrays of close-packed detectors capable of reaching the fundamental limits imposed by the very low photon backgrounds present in deep space. In the near term, bolometer array architectures which permit 1000 pixels - perhaps sufficient for the next generation of space-based instruments - can be arrayed efficiently. Demonstrating the necessary performance, with Noise Equivalent Powers (NEPs) of order 10-20 W/square root of Hz, will be a hurdle in the coming years. Superconducting bolometer arrays are a promising technology for providing both the performance and the array size necessary. We discuss the requirements for future detector arrays in the far-infrared and submillimeter, describe the parameters of superconducting bolometer arrays able to meet these requirements, and detail the present and near future technology of superconducting bolometer arrays. Of particular note is the coming development of large format planar arrays with absorber-coupled and antenna-coupled bolometers.

Benford, Dominic↗