Monolayer-Based Single-Photon Source in a Liquid-Helium-Free Open Cavity Featuring 65% Brightness and Quantum Coherence
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Optimum demodulator for poisson processes is determined for signal processing of photon radiation
This talk covers possible applications for the monoenergetic photon beam currently under development at Lawrence Berkeley National Laboratory's BELLA Center.
Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.
Deterministic coupling between photonic nodes in a quantum network is an essential step toward implementing various quantum technologies. The omnidirectionality of free-standing emitters, however, makes this coupling highly inefficient, in particular if the distant nodes are coupled via low numerical aperture (NA) channels such as optical fibers. This limitation requires placing quantum emitters in nanoantennas that can direct the photons into the channels with very high efficiency. Moreover, to be able to scale such technologies to a large number of channels, the placing of the emitters should be deterministic. In this work, we present a method for directly locating single free-standing quantum emitters with high spatial accuracy at the center of highly directional bullseye metal–dielectric nanoantennas. We further employ non-blinking, high quantum yield colloidal quantum dots for on-demand single-photon emission that is uncompromised by instabilities or non-radiative exciton recombination processes. Taken together, this approach results in a record-high collection efficiency of 85% of the single photons into a low NA of 0.5, setting the stage for efficient coupling between on-chip, room temperature nanoantenna-emitter devices and a fiber or a remote free-space node without the need for additional optics.
Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for E photon = 0.5-30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at I laser ≈ 2 x 10 18 W/cm 2 with CPCs is observed, with doses of >10 rad in air at 1 m for E photon > 0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. Hence these results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.
This document outlines measurements made by Idaho National Laboratory (INL) staff at the Berkeley Lab Laser Accelerator (BELLA) Center. Measurements of a mono-energetic Thomson photon beam were made with various INL instruments. The photon beam was generated by a laser-plasma accelerator system. This project is referred to by the name Laser Wake. Key Lawrence Berkeley National Laboratory (LBNL) personnel involved include Liona Fan-Chiang, Cameron Geddes, Anthony Gonsalves, Robert Jacob, Tobias Ostermayr, and Hai-En Tsai.
Quantum emitters in semiconductor transition metal dichalcogenide (TMD) monolayers hold great promise for many quantum optics applications due to the intriguing properties afforded by the host materials. The creation of localized excitonic states in two-dimensional semiconductors is also fundamentally interesting. Local strain engineering of TMD monolayers has been attested to be a viable approach for creating quantum emitters. However, despite the ubiquitous existence of local topography variations in the structures used to create strain gradients in the TMD monolayers, an understanding of their influence on the strain fields and exciton trapping is notably lacking, especially on the nanoscale. In this study, we investigate WSe 2 monolayers deposited on the edges of asfabricated trenches, which are deemed to induce 1D delocalized strain profiles in the monolayers, and observe optical signatures of weakly confined excitonic states supporting biexciton emission. Here, our numerical simulations of the strain distributions suggest that the quantum emitters originate from quasi-1D like localized strain profiles induced by local topography variations at the trench edges. These findings have strong implications toward the controlled creation of quantum emitters in TMD monolayers and their efficient coupling to photonic structures.
Not Available
Not provided.
Not Available
Not Available
Not Available
Not Available
The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.
This issue of our bi-annual highlights roundup includes a bit of time shifting. The book features a second batch of articles looking back on the calendar year 2019 work of our incomparable users and staff, but included also are some science highlights and other content driven by the COVID-19 pandemic.