Performance and transport in the ARC tokamak

The ARC TM tokamak, a high-field (𝐵 𝑇 = 11.4 T) fusion power plant, under development by Commonwealth Fusion Systems, is studied using a suite of integrated modelling tools to predict its fusion power generation (𝑃𝑓⁡𝑢⁢𝑠), transport and confinement properties. Analysis is based off an ARC operational point scoped first with zero-dimensional (0-D) plasma operational contour (POPCON) modelling to produce 1.13 GW of fusion power. A suite of integrated modelling tools (TRANSP, ASTRA and TORAX) were applied to predict the performance and kinetic profiles of the ARC design point, yielding a range of predicted performance spanning from ∼900 to 1300 MW in rough quantitative agreement with POPCON predictions. The sensitivity of these results to uncertain modelling inputs was probed using scans of pedestal boundary conditions around EPED-predicted values (total pressure and temperature ratios), tungsten concentration and seperatrix density around their nominal assumptions. Pedestal pressure and pedestal top (𝑇 𝑖 /𝑇 𝑒 ) play a large role in 1.5-dimensional performance predictions, able to modify the predicted 𝑃 𝑓⁡𝑢⁢𝑠 by a factor of 2 within reasonable assumptions. High-fidelity core nonlinear gyrokinetic profile predictions, performed using CGYRO (Candy et al. 2016 J. Comput. Phys., vol. 324, pp. 73–93) coupled with the PORTALS (Rodriguez-Fernandez et al. 2024 Nucl. Fusion, vol. 64, 076034; Phys. Plasmas, vol. 31, 2024, 062501) framework, yield substantially lower performance (𝑃 𝑓⁡𝑢⁢𝑠 =677 MW) compared with 0-D and medium-fidelity modelling for nominal assumptions, showing that there is non-negligible uncertainty between models and that future work on SPARC may help resolve discrepancies. Lower overall performance results from significantly reduced volume-averaged densities and temperatures, along with reduced levels of density and temperature peaking. Turbulence and transport are largely dominated by ion temperature gradient across the profile, confirmed by both linear stability and the response of the nonlinear fluxes to changes in gradients, with some impact of kinetic ballooning modes in the deep core. This work represents one of the most complete scoping of potential fusion power plant conditions performed to date. The extensive integrated modelling provides confidence in ARC performance approaching 1 GW, while nonlinear gyrokinetic modelling results in open questions into the physics of density and temperature peaking in fusion-power-plant-relevant operational space. A discussion of results and the role that the SPARC tokamak (Creely et al. 2020 J. Plasma Phys., vol. 86, 865860502) will play in informing ARC design, performance and operation is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma–surface interaction in the stellarator W7-X: conclusions drawn from operation with graphite plasma-facing components

W7-X completed its plasma operation in hydrogen with island divertor and inertially cooled test divertor unit (TDU) made of graphite. A substantial set of plasma-facing components (PFCs), including in particular marker target elements, were extracted from the W7-X vessel and analysed post-mortem. The analysis provided key information about underlying plasma–surface interactions (PSI) processes, namely erosion, transport, and deposition as well as fuel retention in the graphite components. The net carbon (C) erosion and deposition distribution on the horizontal target (HT) and vertical target (VT) plates were quantified and related to the plasma time in standard divertor configuration with edge transform ι = 5/5, the dominant magnetic configuration of the two operational phases (OP) with TDU. The operation resulted in integrated high net C erosion rate of 2.8 mg s -1 in OP1.2B over 4809 plasma seconds. Boronisations reduced the net erosion on the HT by about a factor 5.4 with respect to OP1.2A owing to the suppression of oxygen (O). In the case of the VT, high peak net C erosion of 11μm at the strike line was measured during OP1.2B which converts to 2.5 nm s -1 or 1.4 mg s -1 when related to the exposed area of the target plate and the operational time in standard divertor configuration. PSI modelling with ERO2.0 and WallDYN-3D is applied in an interpretative manner and reproduces the net C erosion and deposition pattern at the target plates determined by different post-mortem analysis techniques. This includes also the 13 C tracer deposition from the last experiment of OP1.2B with local 13 CH 4 injection through a magnetic island in one half module. The experimental findings are used to predict the C erosion, transport, and deposition in the next campaigns aiming in long-pulse operation up to 1800 s and utilising the actively cooled carbon-fibre composite (CFC) divertor currently being installed. The CFC divertor has the same geometrical design as the TDU and extrapolation depends mainly on the applied plasma boundary. Extrapolation from campaign averaged information obtained in OP1.2B reveals a net erosion of 7.6 g per 1800 s for a typical W7-X attached divertor plasma in hydrogen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ICRH operations and experiments during the JET-ILW tritium and DTE2 campaigns

2021 has culminated with the completion of the JET-ILW DTE2 experimental campaign. This contribution summarizes Ion Cyclotron Resonance Heating (ICRH) operations from system and physics point of view. Improvements to the (ICRH) system, to operation procedures and to real time RF power control were implemented to address specific constraints from tritium and deuterium-tritium operations and increase the system reliability and power availability during D-T pulses. ICRH was operated without the ITER-Like Antenna (ILA) because water leaked from an in-vessel capacitor into the vessel on day-2 of the D-T campaign. Three weeks were required to identify and isolate the leak and resume plasma operations. Dedicated RF-Plasma Wall Interaction (PWI) experiments were conducted; tritium plasmas exhibit a higher level of Be sputtering on the outer wall and impurity content when compared to deuterium or hydrogen plasmas. The JET-DTE2 campaigns provided the opportunity to characterize ICRH schemes foreseen for the ITER operation, in the ITER like wall environment in ELMy H-mode scenarios aiming at maximizing fusion performance. The second harmonic tritium resonance heating and to a lesser extent minority 3He heating (ITER D-T ICRH reference schemes) lead to improved ion temperature and fusion performance when compared to hydrogen minority ICRH. However, these discharges suffered from a lack of stationarity and gradual impurity accumulation potentially because of a deficit of ICRH power when using JET antennas at lower frequencies. Fundamental deuterium ICRH was used in tritium-rich plasmas and with deuterium Neutral Beam Heating; this ICRH scheme proved to be very efficient boosting ion temperature and fusion performance in these plasmas.

Klepper, C. Christopher↗

PISCES-RF: a liquid-cooled high-power steady-state helicon plasma device

Radio-frequency (RF) driven helicon plasma sources can produce relatively high-density plasmas (n > 1019 m -3 ) at relatively moderate powers (<2 kW) in argon. However, to produce similar high-density plasmas for fusion relevant gases such as hydrogen (H), deuterium (D) and helium (He), much higher RF powers are needed. For very high RF powers, thermal issues of the RF-transparent dielectric window, used in the RF source design, limit the plasma operation timescales. To mitigate this constraint, we have designed, built and tested a novel helicon plasma source assembly with a fully liquid-cooled RF-transparent window which allows steady state operations at high power (up to 20 kW) and successfully produces high-density plasma with both argon and H. Deionized (DI) water, flowing between two concentric dielectric RF windows, is used as the coolant. We show that a full azimuthal blanket of DI water does not prevent high-density plasma production. From calorimetry on the DI water, we measure the net heat removed by the coolant at steady state conditions. Using infra-red imaging, we calculate the constant plasma heat deposition and measure the final steady state temperature distribution patterns on the inner surface of the ceramic layer. The heat deposition pattern follows the helical shape of the antenna. We also show the consistency between the heat absorbed by the DI water, as measured by calorimetry, and the total heat due to the combined effect of the plasma heating and the absorbed RF. These results are being used to answer critical engineering questions for the 200 kW RF device materials plasma exposure experiment being designed at the Oak Ridge National Laboratory as a next generation plasma material interaction device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vertical instability forecasting and controllability assessment of multi-device tokamak plasmas in DECAF with data-driven optimization

Abstract Reliable vertical position control will be an essential element of any future tokamak-based fusion power plant in order to reduce disruptions and maximize performance. We investigate methods to improve vertical controllability boundary determination in plasma operational space and demonstrate a data-driven approach based on direct pseudoinversion of operational space data that is rigorously quantitative, applicable in real-time plasma control systems, and physically intuitive to interpret. Applied to historical shot data from entire run campaigns on the MAST-U, KSTAR, and NSTX tokamaks, this approach, implemented in DECAF, improves vertical displacement event identification accuracy to 98.9%–100%. Further, we explore the application of a physics-based vertical stability metric as an early warning forecaster for vertical displacement events. The development of a linear surrogate model for the plasma current density profile, with a coefficient of determination of 0.992 on the training dataset, enables potential employment of this forecaster in real-time. The application of this approach on historical data from the MAST-U MU02 campaign yields a forecaster with 62.6% accuracy, indicating promise for this method when further refined and potentially coupled with other stability metrics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Large radiation back-flux from Monte Carlo simulations of fusion neutron–material interactions

Abstract Fusion power reactors will generate intense neutron fluxes into plasma-facing and structural materials (SMs). Radiation back-fluxes, generated from neutron–material interactions under these fluxes, can dramatically impact the plasma dynamics, e.g. by seeding runaway electrons during disruptions via Compton scattering of background electrons by wall-emitted gamma radiation. Here, we quantify these back-fluxes, including neutrons, gamma rays, and electrons, using Monte Carlo calculations for a range of SM candidates and first wall (FW) thicknesses. The radiation back-flux magnitudes are remarkably large, with neutron and gamma radiation back-fluxes on the same order of magnitude as the incident fusion neutron flux. Electron back-fluxes are two orders of magnitudes lower, but are emitted at sufficiently high energies to impact the sheath and boundary plasma dynamics. Material configuration plays a key role in determining back-flux magnitudes. The SM chiefly determines the neutron back-flux magnitude, while the FW thickness principally attenuates the gamma ray and electron back-fluxes. In addition to prompt back-fluxes, which are emitted immediately after fusion neutrons impact the surface, significant delayed gamma ray and electron back-fluxes arise from nuclear decay processes in the activated materials. These delayed back-flux magnitudes range from 2% to 7% of the prompt back-fluxes, and remain present during transients when fusion no longer occurs. During disruptions, build-up of delayed gamma radiation back-flux represents potential runaway electron seeding mechanisms, posing additional challenges for disruption mitigation in a power reactor compared with non-nuclear plasma operations. This work highlights the impact of these radiation back-fluxes plasma performance and demonstrates the importance of considering back-flux generation in materials selection for fusion power reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an Integrated Multidiagnostic to Assess the High-Z Impurity Fluxes in the Metallic Environment of WEST Using IMAS

WEST is an actively cooled, long-pulse tokamak with nearly all plasma-facing components (PFC) made of tungsten. One of the aims of WEST is to study plasma operations with tungsten PFCs in preparation for long-pulse operations on high-Z divertor devices, such as ITER. For long-pulse operation, the high-Z impurity content and transport to the core plasma are critical concerns that require further measurement and interpretation to improve plasma performance and PFC durability. This work details the impurity influxes in WEST during a series of discharges in which the lower hybrid (LH) injected power was incrementally increased. An analysis has been performed of measurements collected from an array of edge diagnostics. Visible spectroscopy was utilized to measure the spectral radiances generated by fuel particles (D) and impurities (W, O, and C) at the divertor and at the antennas with a newly developed spectral peak-fitting tool used to analyze the data in WEST. The scrape-off layer (SOL) plasma conditions (n e and T e ) measured at the divertor target with flush Langmuir probes and near the outer mid-plane (OMP) using reciprocating Langmuir probes (RCPs) are used to evaluate the number of ionizations per photons (S/XB) coefficients required to estimate the impurity fluxes obtained with the collisional-radiative model ColRadPy. Here, the array of edge diagnostics discussed in this work, coupled with SOL plasma modeling tools, represents a multidiagnostic interpretative modeling workflow that will continue to be applied to upcoming experimental campaigns on the WEST experiment to assess high-Z impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the KSTAR experiments and future plan

The Korea Superconducting Tokamak Advanced Research (KSTAR) device has recently entered a new phase of operation following the installation of a tungsten mono-block divertor, providing a unique platform to investigate high-performance, long-pulse plasma scenarios for future reactors. The 2023–2024 experimental campaigns demonstrated significant progress in commissioning the tungsten divertor, developing plasma operation scenarios, and achieving real-time control. Comparative studies revealed increased core radiation losses and associated performance degradation relative to the carbon divertor environment. Alleviation strategies, such as optimized neutral beam injection timing, boron powder seeding, and impurity control through gas puffing, were shown to reduce tungsten accumulation and extend high-performance phases, including record H-mode operation exceeding 100 s. International collaboration enabled the first demonstration of high poloidal beta scenarios with an internal transport barrier on KSTAR. Advances in control included upgraded real-time resonant magnetic perturbation schemes and disruption forecasting. Furthermore, divertor detachment control using a new surrogate-model-based approach with real-time radiation imaging demonstrated active impurity and heat flux management. Supported by enhanced heating, current drive, and diagnostic systems, these achievements offer valuable insights into tungsten impurity behavior, transport physics, and control strategies for future reactors including ITER. Planned upgrades toward a full-tungsten wall and ITER-aligned real-time plasma control will further establish KSTAR as a leading experimental platform for developing operational scenarios required to achieve steady-state, burning plasma conditions.

KSTAR↗

Plasma performance and operational space without ELMs in DIII-D

A database of DIII-D plasmas without ELMs compares the operating space and plasma performance of stationary no-ELM regimes: RMP-ELM suppression, QH-mode, I-mode, EDA H-mode, L-mode, and negative triangularity L-mode (Neg-D). Here, operational space is documented in terms of engineering and physics parameters, revealing divergent constraints. Some operational space discriminants (like pedestal collisionality) are well known, while others, such as low torque & safety factor, or high power & density, are less commonly emphasized. Normalized performance (H-factor and betan) also discriminate the no-ELM regimes and favor regimes tolerant to power in DIII-D: RMP, QH, and Neg-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of Wendelstein 7-X high-performance operation

The Wendelstein 7-X (W7-X) stellarator has completed two consecutive experimental campaigns OP 2.2 (Sep.-Dec. 2024) and OP 2.3 (Feb.-May 2025) under a new operational strategy enabling more than one year of uninterrupted device availability. This approach, supported by exceptionally high subsystem reliability, allowed sustained high-efficiency plasma operations with up to 80–100 discharges per day across a broad range of magnetic configurations. Several key technical upgrades-most notably the first operation of a 1.5 MW class steady-state gyrotron, a new steady-state pellet injector, and advanced real-time feedback control systems significantly enhanced heating, fueling, and plasma control capabilities. Together, these improvements enabled major advances in long-pulse performance, high-β operation, and confinement optimization. Long-pulse discharges achieved 1.8 GJ of injected energy under fully detached divertor conditions, while reduced-field scenarios facilitated record volume-averaged β values approaching 3%. High-performance plasmas with centrally peaked density profiles, created via neutral beam injection (NBI) or sustained pellet fueling, demonstrated strongly reduced turbulent transport and stellarator-record fusion triple products. Complementary studies of power exhaust and divertor heat loads revealed the role of scrape-off-layer drift physics in shaping strike-line patterns under attached conditions. Together, the results from OP 2.2 and OP 2.3 significantly expand the operational space of W7-X and strengthen its role as a leading platform for steady-state stellarator research and reactor-relevant plasma scenarios.

Wendelstein 7-X↗

Development of high-performance long-pulse discharge in KSTAR

High-performance long-pulse plasma operation is essential for producing economically viable fusion energy in tokamak devices. To achieve such discharges in KSTAR, firstly, the rapid increase in the temperature of plasma-facing components was mitigated. The temperature increase of the poloidal limiter, especially, was associated with beam-driven fast ion orbit loss and the discrepancy of the equilibrium reconstructed with heated magnetic probes of signal drift. The fast ions lost to the poloidal limiter were reduced by optimizing the plasma shape and the composition of neutral beam injection (NBI). This nonlinear signal drift was successfully reduced by a new thermal shielding protector on the magnetic probes. Secondly, a lower loop voltage approach was implemented to reduce a poloidal flux consumption rate. A plasma current of 400 kA and a line-averaged electron density of ~2.0 × 10 19 m –3 were chosen by considering the L–H power threshold, fast ion orbit loss, and beam shine-through power loss for low loop voltage in KSTAR. In addition, the application of electron cyclotron heating also helped maintain the plasma with low loop voltage (~25 mV) by enhancing the NBI-driven current and achieving a high poloidal beta (β P ) state. KSTAR has achieved a long pulse (~90 s) operation with the high performance of β P $\leqslant$ 2.7, thermal energy confinement enhancement factor (H 98y2 ) ~ 1.1, and fraction of non-inductive current (f NI ) $\leqslant$ 0.96. Still, gradual degradation of the plasma performance has been observed over time in the discharges. In one of the long-pulse discharges, β P reduced by ~18% over the time of ~8τ R (current relaxation time, τ R ~5 s) and ~1067τ E,th (thermal energy confinement time, τ E,th ~45 ms). The degradation may be closely associated with weak, yet growing, and persistent toroidal Alfvén eigenmodes and their effect on fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral gas analysis for JET DT operation

Neutral gas analysis, the measurement and evaluation of total and partial pressures, is a key technique to study the impact of neutral gas dynamics on retention, recycling and release processes of fuel or impurity species in fusion devices. At JET, the experiment closest to ITER in terms of operating parameters and size, various detectors and techniques for partial pressure and total pressure measurements are deployed together to characterise neutral gas dynamics during and after plasma operation on various toroidal and poloidal locations. An extensive modification of JET's sub-divertor neutral gas diagnostic system aims at retaining and extending established measurement capabilities in the forthcoming Deuterium-Tritium (DT) experiments (DTE2). To achieve DT compatibility, a separation of radiation-sensitive electronics from the sensor and adequate radiation shielding is required, as well as utilisation of a DT compatible differential pumping system with adjustable throughput to account for the strong pressure variation in the sub-divertor region. Finally, the sub-divertor neutral gas diagnostic will be equipped with multiple Residual Gas Analysers (RGAs), utilising quadrupole mass spectrometry and electrostatic ion-trap-principles, all operating with remote electronics located behind the biological radiation shield. These RGAs will record data in a fast selected discrete mass mode during plasma pulses (cycle ~2 s) and will automatically switch back to continuous data recording (cycle ~100 s) afterwards. They will be complemented by a newly improved Penning gauge spectroscopy configuration in particular supporting the He and D 2 separation relevant for DT operation. The distance between these devices and their associated control unit is typically 15m . A newly developed RGA with a cable length of 80 m, compatible with the ITER environment, will also be employed for the first time. Finally, this set-up and its operation in DTE2 will provide vital input to the development of the ITER divertor RGA in the most relevant environment currently available.

47 OTHER INSTRUMENTATION↗

High-performance ECRH at W7-X: experience and perspectives

The second operation phase of W7-X (OP1.2) showed the potential of exclusively electron cyclotron resonance heating (ECRH)-sustained plasma operations in stellarators. Employing multi-pass ECRH scenario in the second harmonic O-mode (O2-ECRH), stationary densities of up to 1.4 × 10 20 m -3 could be achieved. This scenario also made stationary divertor detachment possible, which is a reactor-relevant scenario for power and particle exhaust. At high densities and with sufficiently high density gradients for an improved ion confinement, the coupling between the electrons and ions was strong enough to bring the ion temperature to values above 3 keV and to the neoclassical limit for some magnetic configurations, thus enabling to test the W7-X neoclassical optimization. The planned enhancement of the ECRH performance will enable to advance towards reactor-relevant beta values and to investigate their stability and confinement of fast particles, which is a priority goal of W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma performance and operational space with an RMP-ELM suppressed edge

Abstract The operational space and global performance of plasmas with edge-localized modes (ELMs) suppressed by resonant magnetic perturbations (RMPs) are surveyed by comparing AUG, DIII-D, EAST, and KSTAR stationary operating points. RMP-ELM suppression is achieved over a range of plasma currents, toroidal fields, and RMP toroidal mode numbers. Consistent operational windows in edge safety factor are found across devices, while windows in plasma shaping parameters are distinct. Accessed pedestal parameters reveal a quantitatively similar pedestal-top density limit for RMP-ELM suppression in all devices of just over 3 × 10 19 m −3 . This is surprising given the wide variance of many engineering parameters and edge collisionalities, and poses a challenge to extrapolation of the regime. Wide ranges in input power, confinement time, and stored energy are observed, with the achieved triple product found to scale like the product of current, field, and radius. Observed energy confinement scaling with engineering parameters for RMP-ELM suppressed plasmas are presented and compared with expectations from established H and L-mode scalings, including treatment of uncertainty analysis. Different scaling exponents for individual engineering parameters are found as compared to the established scalings. However, extrapolation to next-step tokamaks ITER and SPARC find overall consistency within uncertainties with the established scalings, finding no obvious performance penalty when extrapolating from the assembled multi-device RMP-ELM suppressed database. Overall this work identifies common physics for RMP-ELM suppression and highlights the need to pursue this no-ELM regime at higher magnetic field and different plasma physical size.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited)

A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ~100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ~1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the T e profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. As a result, this allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.

47 OTHER INSTRUMENTATION↗

Evaluation of ITER divertor shunts as a synthetic diagnostic for detachment control

Reliable diagnostics that measure the detached state of the ITER divertor plasma will be necessary to control heat flux to the divertor targets during steady state, burning plasma operation. This paper conducts an initial exploration into the feasibility of the divertor shunt diagnostic as a lightweight, robust, and real-time detachment sensor. This diagnostic is a set of shunt lead pairs that measure the voltage drop along the divertor cassette body, from which the plasma scrape-off layer (SOL) current is calculated. Using SOLPS-ITER simulations for control-relevant ITER plasma scenarios, the thermoelectric current magnitude along the SOL is shown to decrease significantly with the onset of partial detachment at the outer divertor target. Electromagnetic modelling of a simplified divertor cassette is used to develop a control-oriented inductance-resistance circuit model, from which SOL currents can be calculated from shunt pair voltage measurements. The sensitivity and frequency-response of the resulting system indicates that the diagnostic will accurately measure SOL thermoelectric currents during ITER operation. These currents will be a good measure of the detached state of the divertor plasma, making the divertor shunt diagnostic a potentially extremely valuable and physically robust sensor for real-time detachment control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.