Search NASA⌕ Search

SEARCH · Search NASA

Results for “plenum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effects of bleed-hole geometry and plenum pressure on three-dimensional shock-wave/boundary-layer/bleed interactions

A numerical study was performed to investigate 3D shock-wave/boundary-layer interactions on a flat plate with bleed through one or more circular holes that vent into a plenum. This study was focused on how bleed-hole geometry and pressure ratio across bleed holes affect the bleed rate and the physics of the flow in the vicinity of the holes. The aspects of the bleed-hole geometry investigated include angle of bleed hole and the number of bleed holes. The plenum/freestream pressure ratios investigated range from 0.3 to 1.7. This study is based on the ensemble-averaged, 'full compressible' Navier-Stokes (N-S) equations closed by the Baldwin-Lomax algebraic turbulence model. Solutions to the ensemble-averaged N-S equations were obtained by an implicit finite-volume method using the partially-split, two-factored algorithm of Steger on an overlapping Chimera grid.

Chyu, Wei J.↗

Emission Spectral Measurements in the Plenum of an Arc Jet Wind Tunnel

Arc jet wind tunnel facilities are used to evaluate thermal protection system materials for re-entry vehicles. The high speed, high temperature flowfield generated by the arc jet can simulate the extreme aerodynamic heating environment experienced during re-entry so that the survivability of heat shield materials and performance of various designs options can be tested. Although the re-entry heating environment can be approximated in the arc jet facility, the flowfield only partially simulates the actual re-entry flight conditions. Reynolds numbers are not matched so that surface shear stress distributions and mass transfer rates due to ablation or other mechanisms are not modeled correctly. Unlike flight conditions the arc freestream air is in non-equilibrium because of the rapid expansion that occurs in the supersonic nozzle. To properly study the actual re-entry flow environment, computational fluid dynamics, computational chemistry and radiation models must be used. Arc jet tunnel tests serve to validate these models. To perform accurate simulations inlet and boundary-conditions are needed, which come from measurements of the flowfield. The present study is concerned with measurements in the plenum region of an arc heater. In the past, conditions in the arc heater flowfield have been predicted using simulations since conventional measurement techniques could not be used in the harsh extremely high temperature environment. The present study is part of a recent push to utilize optical techniques to help better characterize the arc jet flowfields. Emission measurements have been made in the shock layer and the constrictor section of the arc heater to determine temperatures and species number densities. LIF measurements have been made in the free stream to determine temperature and velocity.

Donohue, Jim↗

It’s Hip To Be Square - Refurbishment of the NASA Langley National Transonic Facility Test Section Plenum Door

The “nearside” plenum door (NPD) at the 39-year-old NASA Langley Research Center (LARC) National Transonic Facility (NTF) has become increasingly recalcitrant during the opening /closing sequence. The NPD is the primary means of entry into the test section for personnel and for model installation. The sliding NPD hardware guide bearings have failed three (3) times within a one-year period and “quick fixes” were able to be made to guide rails, wheels and bearings to put the NPD back into operation. The NPD no longer can utilize a “quick fix” as the rolling hardware is at its limit for further modifications. This presentation will describe the NPD situation, the findings as to the cause of the periodic NPD failures, and the solution to remove, refurbish, and reinstall the NPD.

Test Facilities↗

OSU High Temperature Test Facility Test Acceptance Report, PG-28 Low Power (<350kW) Lower Plenum Mixing Test

Test Acceptance Report for Test PG-28 at the Oregon State University High Temperature Test Facility. The purpose of this test is to investigate the impact on Lower Plenum thermal profiles and mixing due to changes in the system mass flow rate in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

OSU High Temperature Test Facility Test Acceptance Report, PG-30 Low Power (<350kW) Lower Plenum Mixing, Constant Temperature Test

Test Acceptance Report for Test PG-30 at the Oregon State University High Temperature Test Facility. The purpose of this test is to investigate the impact on Lower Plenum thermal profiles and mixing due to changes in the system mass flow rate in an integral test facility scaled to General Atomics’ Modular High Temperature Gas Reactor (MHTGR) design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An intelligent scanning algorithm for lost fuel rod recovery in the MYRRHA lower plenum

This paper presents a system for visualizing the interior structure of a vessel filled with a liquid metal. Due to the opaque and conductive nature of the medium, regular visualization systems based on cameras, electromagnetic or laser based techniques can't be used. The operation, strengths and weaknesses of an existing set-up are investigated by creating a scenario to find and extract a rectangular object inside the vessel in the shortest possible time. The main focus of this paper is not on designing a new system but to investigate the bottlenecks that are faced and need to be kept in mind in future designs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of additively manufactured surface roughness on small diameter plenums with multiple side discharges for high temperature gas turbine blade cooling applications

Combined heat and power (CHP) applications have significant environmental and economic benefits that are consistent with the goals of the U.S. Department of Energy (DOE). One area that is currently being studied includes the potential benefits of CHP turbine operation at higher turbine inlet temperatures. Internal cooling concepts enabled by additive manufacturing (AM) are of primary interest. Here, the effectiveness of internal cooling is hindered by many factors such as velocity distribution of the cooling air to the hot surface considering impingement cooling. To simulate cooling air exiting from a series of orifices for internal cooling in an airfoil, a straight smooth wall tubing with multiple side discharging orifices is used and compared to additively manufactured tubing (Ti6Al4V Grade 23) with orifice size and spacing as well as inner and outer diameters identical to the smooth wall tubing. Similar to flow discharging form perforated pipes, the flow discharged from individual orifices along the tubes in this study is found to be nonuniformly distributed, and the horizontal (axial direction) momentum can be observed from the experimental data. Discharge velocities have been measured with two-dimensional (2D) particle imaging velocimetry (PIV) and single element hot wire anemometry. Numerical analysis has also been conducted to predict the velocity distributions along the orifices in the smooth wall and additive manufacturing (AM) tubing, which are inherited with surface roughness. Numerical and measured results in this study are compared, presented, and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiple stack fuel cell system with shared plenum

A multi-stack fuel cell system is disclosed where multiple fuel cell stacks can be efficiently connected together. The fuel cell system includes a plurality of fuel cell modules include a sealed planar fuel cell stack that has internal manifold channels for transport of fuel and air to fuel cells within the stack and transport of tail gas and spent air away from fuel cells within the stack. Each of the fuel cell stacks is mounted on a base manifold, and the base manifold has side openings in fluid communication with the stack internal manifold channels. The side openings on the base manifold are configured so that the modules can be efficiently connected together.

Schneider, Jonathan↗