Search NASA⌕ Search

SEARCH · Search NASA

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Methodology for Mechanical Property Testing of Fuel Cladding Using a Expanded Plug Wedge Test

An expanded plug method was developed earlier for determining the tensile properties of irradiated fuel cladding. This method tests fuel rod cladding ductility by utilizing an expandable plug to radially stretch a small ring of irradiated cladding material. The circumferential or hoop strain is determined from the measured diametrical expansion of the ring. A developed procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves, from which material properties of the cladding can be extracted. However, several deficiencies existed in this expanded-plug test that can impact the accuracy of test results, such as that the large axial compressive stress resulted from the expansion plug test can potentially induce the shear failure mode of the tested specimen. Moreover, highly nonuniform stress and strain distribution in the deformed clad gage section and significant compressive stresses, induced by bending deformation due to clad bulging effect, will further result in highly nonconservative estimates of the mechanical properties for both strength and ductility of the tested clad. To overcome the aforementioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. By optimizing the specific geometry designs, selecting the appropriate material for the expansion plug, and adding new components into the testing system, a modified expansion plug testing protocol has been developed. A general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor, -factor, was used to convert the ring load Fring into hoop stress , and is written as _ = F_ring/tl , where t is the clad thickness and l is the clad length. The generated stress-strain curve agrees well with the associated tensile test data in both elastic and plastic deformation regions.

expansion plug test↗

Dip leg plug formation evaluation and abatement testing in support of the H-Canyon accelerated basin de-inventory

As requested in the Technical Task Request (TTR), the Savannah River National Laboratory (SRNL) performed testing on the current typical bubbler dip leg design used in the H-Area Canyon (HCA). The TTR has a functional classification of General Services. Testing was initiated to ascertain if the plugging described in the TTR could be reproduced and, if so, to obtain general metrics on the resulting plugging dynamics, and evaluate possible mitigating methods, including design changes and cleaning/purging protocols. The bubblers were to be suspended in a simulant typical of H-Canyon solutions containing aluminum nitrate and silica at a temperature of 25°C using a nominal bubbler air flowrate of 7.5 SCFH. Emphasis was placed on minimizing equipment changes necessary to accomplish the mitigations, as equipment changes in the existing facility would be costly. Testing evolved into four (4) phases, concluding that plugging could indeed be reproduced (believed to be attributed to localized evaporation and bridging of crystals in the dip legs). During testing, plug formation information was obtained, including time, pressure, and temperature traces leading to plugging were defined; solution compositions leading to plugging were determined, and various physical characteristics (visual and mechanical) of the crystallized plug were obtained.

42 ENGINEERING↗

Understanding the importance of the viscosity contrast between the sample solvent plug and the mobile phase and its potential consequences in two-dimensional high-performance liquid chromatography

The effect of solvent viscosity mismatch on elution performance in reversed-phase HPLC was studied using moment analysis. Two conditions were tested: (1) the mobile phase viscosity was less than the injection plug viscosity, and (2) the mobile phase viscosity was greater than the injection plug viscosity. Under the first condition, retention time and elution performance decreased as the viscosity contrast between the mobile phase and injection plug increased. The effect on performance was more marked as the injection volume increased. A decrease in performance of 12% for compounds with retention factors up to 2.8 was apparent even when the viscosity contrast was only 0.165 cP. In the second set of conditions, elution performance was actually observed to increase, by as much as 25% for a 40 {micro}L injection, as the viscosity contrast between the mobile phase and the solute plug increased. No change in the retention factor was observed. This behaviour was attributed to the shape of an injection plug as it enters into the column, whereby a low viscosity plug permeates away from the wall when the column contains a higher viscosity mobile phase, and vice a versa for a high viscosity plug entering a low viscosity mobile phase. At no stage was either a band splitting or shoulders observed with viscosity contrasts up to 1.283 cP, as could have been expected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ceramic Plugs for Deep Borehole Seals - 17316

In the deep borehole nuclear waste disposal concept, waste packages are emplaced deep in crystalline rock formations under conditions of high pressures, high mineral content water, and elevated temperatures. Well seals and plugs must perform for thousands of years. A novel ceramic plug system under development capitalizes on the thermal energy of thermite mixtures and engineered additives to react and form ceramic-like plugs in place with favorable structural, flow, and geochemical properties. Depending on the ingredients, the reaction can produce aluminosilicates, plagioclase feldspars, or other combinations in crystalline or amorphous forms. Normative mineralogy techniques were applied to predict product mineralogy and evaluate compatibility with host rocks, and showed they are comparable to igneous rock analogs. The results support a tentative geochemical compatibility between these formulations and granitic host rock. Because the reaction produces a significant amount of thermal energy, the thermal/structural/fluid response of the plug and surrounding media was evaluated with the FEHM code. Temperatures near the plug/rock interface are estimated to peak at less than 600 deg. C and cool to near ambient temperature within a day. Rock stresses resulting from the thermal pulse are predicted to be similar to the unconfined compressive strength of granites, and generally lower than triaxial test results. Entrained fluid expansion due to heating was shown to be lower than failure stresses. Little or no failure in the surrounding media would be expected due to the plug formation process. The present efforts are focused on refining the material formulations, evaluating the geochemical and mechanical interactions between the plug and host rock, and testing the plug formation process in scaled granite and basalt masses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plug and Play PV Systems for American Homes

The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work during this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.

14 SOLAR ENERGY↗

Efficient and Zero Net Energy-Ready Plug Loads

Plug loads are the devices plugged into common electrical outlets. Modern buildings contain hundreds of these devices which, together, are responsible for at least 25 percent of the energy use in California buildings. Energy consumed by plug loads is increasing because the “Internet of Things” is, to a great extent, the “Internet of Plug Loads.” This project developed technologies that will reduce the energy use of plug loads. Two crosscutting strategies were investigated in detail: (1) technologies to reduce standby power use to near zero, and (2) methods to increase the use of direct current (DC) as a power source. Two new approaches to reduce standby to near zero were developed and have potential applicability to a wide range of devices. Prototype DC appliances were developed to demonstrate energy savings by bypassing power supplies and avoiding other losses. Networks of DC-powered devices can save even more energy and provide other benefits, such as resiliency during power outages. A unique category of energy-using devices was identified that provide life safety, health, and security to building occupants. Their installation or use is dictated by building codes, health providers, insurance companies, and other entities—none of whom would ordinarily prioritize energy efficiency. In the case of ground fault circuit interrupts (GFCIs), savings of 80 percent appear possible, simply by adopting the most efficient designs. Home medical equipment, particularly oxygen concentrators, are a rising category of energy use where significant savings are possible. This report also reviews the codes, standards, and other policies that affect energy use of plug loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plug Load Management System Field Study

In 2018, NREL performed a demonstration of the IBIS InteliNetwork(TM) plug load management system, which includes: intelligent socket devices, which plug into existing electrical outlets and collect energy usage information; a gateway, which manages communication between the intelligent sockets and the PLM cloud service; and a PLM network, which is a cloud-based measurement and control network for the entire system. Two retail stores served as the field study sites. The PLM system was found to be effective at reducing plug load energy use, with a projected annual plug load reduction of 11% and 18% at the test locations. Retail staff reported that the hardware was easy to use, but no one used the online data management system, intended to analyze and control the hardware. This PLM solution shows promise as an effective means to monitor, control, and reduce plug load energy use, but the economics of the system need to be improved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ureteric Embolization for Lower Urinary Tract Fistulae: Use of Two Amplatzer Vascular Plugs and N-Butyl Cyanoacrylate Employing the 'Sandwich' Technique

PurposeThis study describes and evaluated the effectiveness of occluding distal ureters in the clinical setting of urinary vaginal (vesicovaginal or enterovesicovaginal) fistulae utilizing a new technique which combines Amplatzer vascular plugs and N-butyl cyanoacrylate.MaterialsThis is a retrospective study (January 2007-December 2010) of patients with urinary-vaginal fistulae undergoing distal ureter embolization utilizing an Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique. An 8-12-mm type-I or type-II Amplatzer vascular plug was delivered using the sheath and deployed in the ureter distal to the pelvic brim. Instillation of 0.8-1.5 cc of N-butyl cyanoacrylate into ureter proximal to the Amplatzer plug was performed. This was followed by another set of 8-12-mm type-I or type-II Amplatzer vascular plugs in a technique referred to as the 'sandwich technique.'ResultsFive ureters in three patients were occluded utilizing the above-described technique during the 4-year study period. Mean maximum size Amplatzer used per ureter was 10.8 mm (range, 8-12). One ureter required three Amplatzer plugs and the rest required two. Two patients (3 ureters) were clinically successful with complete resolution of symptoms in 36-48 h. The third patient (2 ureters) was partly successful and required a second Amplatzer- N-butyl cyanoacrylate sandwich technique embolization. The mean clinical follow-up was 11.3 months (range, 1.7-29.2).ConclusionsThe Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique for occluding the distal ureter is safe and effective with a quick (probably due to the N-butyl cyanoacrylate) and durable (probably due to the Amplatzer plugs) clinical response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Liquid microjunction surface sampling probe fluid dynamics: Characterization and application of an analyte plug formation operational mode

The recently discovered sample plug formation and injection operational mode of a continuous flow, coaxial tube geometry, liquid microjunction surface sampling probe (LMJ-SSP) (J. Am. Soc. Mass Spectrom, 2011) was further characterized and applied for concentration and mixing of analyte extracted from multiple areas on a surface and for nanoliter-scale chemical reactions of sampled material. A transparent LMJ-SSP was constructed and colored analytes were used so that the surface sampling process, plug formation, and the chemical reactions could be visually monitored at the sampling end of the probe before being analyzed by mass spectrometry of the injected sample plug. Injection plug peak widths were consistent for plug hold times as long as the 8 minute maximum attempted (RSD below 1.5%). Furthermore, integrated injection peak signals were not significantly different for the range of hold times investigated. The ability to extract and completely mix individual samples within a fixed volume at the sampling end of the probe was demonstrated and a linear mass spectral response to the number of equivalent analyte spots sampled was observed. Lastly, using the color and mass changing chemical reduction of the redox dye 2,6-dichlorophenol-indophenol with ascorbic acid, the ability to sample, concentrate, and efficiently run reactions within the same plug volume within the probe was demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Phenomenological Model for the Transport and Plugging of Aerosol through Stress Corrosion Cracks

Recent experimental evidence from Sandia (2018) demonstrated partial microchannel plugging due to particulate deposition. A direct consequence is that the accuracy of consequence assessments can be improved by accounting for the leak path deposition of aerosol in the source term. The filtration effect of microchannels, such as cracks, is relevant to the source term assessments. An important side effect of aerosol deposition in leak paths could be the plugging of the leak path. This report summarizes current progress (as of end of FY19) on the development of a phenomenological model of aerosol transport, deposition, and plugging through microchannels. The purpose is to introduce a generic, reliable numerical model for prediction of aerosol transport, deposition, and plugging in leak paths that are similar to stress corrosion cracks while accounting for potential plugging formation. This effort includes (i) development of a numerical model to analyze the various deposition processes in leak paths and provide quantitative estimates of penetration factors, as well as an understanding of the variables that affect them, (ii) confirmation of model validity with theoretical and experimental data, and (iii) parametric analysis for different scenarios including various particle sizes, pressures, and crack dimensions. Such a model could be used to improve the accuracy of consequence assessments and reduce the uncertainty of radiological consequence predictive analyses by taking the filtering effect of leak path aerosol deposition and plugging into account in the source term. This report includes: (i) an overview of main stress corrosion cracking characteristics, (ii) an overview of the developed numerical model to analyze the various deposition processes in leak paths, to provide quantitative estimates of penetration factors, and to gain an understanding of the variables that affect them, (iii) a summary of validation results and verification of the model’s validity with recent experimental results from Sandia and others, and (iv) a model application example.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental investigations on sodium plugging in narrow flow channels.

A series of experiments was performed to investigate the potential for plugging of narrow flow channels of sodium by impurities (e.g., oxides). In the first phase of the experiments, clean sodium was circulated through the test sections simulating flow channels in a compact diffusion-bonded heat exchanger such as a printed circuit heat exchanger. The primary objective was to see if small channels whose cross sections are semicircles of 2, 4, and 6 mm in diameter are usable in liquid sodium applications where sodium purity is carefully controlled. It was concluded that the 2-mm channels, the smallest of the three, could be used in clean sodium systems at temperatures even as low as 100 to 110 C without plugging. In the second phase, sodium oxide was added to the loop, and the oxygen concentration in the liquid sodium was controlled by means of varying the cold-trap temperature. Intentional plugging was induced by creating a cold spot in the test sections, and the subsequent plugging behavior was observed. It was found that plugging in the 2-mm test section was initiated by lowering the cold spot temperature below the cold-trap temperature by 10 to 30 C. Unplugging of the plugged channels was accomplished by heating the affected test section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on the Field Performance of A123Systems’s HymotionTM Plug-in Conversion Module for the Toyota Prius

A123Systems’s HymotionTM L5 Plug-in Conversion Module (PCM) is a supplemental battery system that converts the Toyota Prius hybrid electric vehicle (HEV) into a plug-in hybrid electric vehicle (PHEV). The Hymotion system uses a lithium ion battery pack with 4.5 kWh of useable energy capacity. It recharges by plugging into a standard 110/120V outlet. The system is designed to more than double the Prius fuel efficiency for 30-40 miles of charge depleting range. If the Hymotion pack is fully depleted, the Prius operates as a normal HEV in charge sustaining mode. The Hymotion L5 PCM is the first commercially available aftermarket product complying with CARB emissions and NHTSA impact standards. Since 2006, over 50 initial production Hymotion Plug-in Conversion Modules have been installed in private fleet vehicles across the United States and Canada. With the help of the Idaho National Laboratory, which conducts the U.S. Department of Energy’s (DOE) Advanced Vehicle Testing Activity (AVTA), A123Systems collects real-time vehicle data from each fleet vehicle using on-board data loggers. These data are analyzed to determine vehicle performance. This paper presents the results of this field evaluation. Data to be presented includes the L5 Prius charge depleting range, gasoline fuel efficiency, and electrical energy efficiency. Effects of driving conditions, driving style, and charging patterns on fuel efficiency are also presented. Data show the Toyota Prius equipped with the Hymotion Plug-in Conversion Module is capable of achieving over 100 mpg in certain driving conditions when operating in charge depleting mode.

33 ADVANCED PROPULSION SYSTEMS↗

An Expanding Plug Test Method for Determining Hoop Stress-Strain Curves of Irradiated Nuclear Fuel Cladding

A method, referred to as the expanding plug test method, for determining the roomtemperature hoop stress-strain curves of irradiated nuclear fuel cladding has been developed and applied to evaluate tensile strength and ductility in the hoop direction of clad material irradiated to high neutron fluences. The test utilizes an incompressible plug fitted within a tubular cladding specimen. A cylindrical punch is used to compress the plug axially, which generates a radial displacement that acts upon the inner diameter of the specimen. Position sensors track the radial displacement of the specimen outer diameter as the compression proceeds. An auxiliary compression test of the plug alone is also performed. Using these two sets of data, a procedure was developed to determine the hoop stress in the clad specimen. The development of this simple, cost-effective, highly reproducible test method to determine stressstrain curves in the hoop direction of irradiated clad specimens represents a significant advancement in the mechanical characterization of irradiated cladding. This paper will present an overview of the expanding plug testing technique and will discuss tests performed on irradiated clad specimens to date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Splenic Artery Syndrome After Orthotopic Liver Transplantation: Treatment With the Amplatzer Vascular Plug

Purpose: To evaluate the safety and efficacy of the Amplatzer vascular plug (AVP) for embolization of the splenic artery in patients with hepatic hypoperfusion after orthotopic liver transplantation (OLT). Materials and Methods: Thirteen patients (9 men and 4 women) with a mean age of 56 years (range 22-70) who developed splenic artery syndrome after OLT with decreased liver perfusion and clinically relevant impairment of liver function (increased transaminase or serum bilirubin levels, thrombocytopenia, and/or therapy-refractory ascites) were treated by embolization of the proximal third of the splenic artery using the AVP. The plugs ranged in diameter from 6 to 16 mm, and they were introduced through femoral (n = 9), axillary (n = 3), or brachial (n = 1) access using a 5F or 8F guiding catheter. Results: The plugs were successfully placed, and complete occlusion of the splenic artery was achieved in all patients. Placement of two plugs was necessary for complete occlusion in 3 of the 13 patients. Occlusion took on average 10 min (range 4-35). There was no nontarget embolization or plug migration into more distal segments of the splenic artery. All patients showed improved arterial perfusion, including the liver periphery, on postinterventional angiogram. After embolization, liver function parameters (transaminase and bilirubin levels) improved with normalization of concomitant thrombocytopenia and a decrease in ascites volume. Conclusion: Our initial experience in a small patient population with SAS suggests that the AVP enables precise embolization of the proximal splenic artery, thus providing safe and effective treatment for poor liver perfusion after OLT due to SAS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Small Intestinal Submucosa Plug for Closure of Dilated Nephrostomy Tracts: A Pilot Study in Swine

The aim of this study was to evaluate efficacy of a plug made of small intestinal submucosa (SIS) for closure of dilated nephrostomy tract in the kidney after nephroscopy. Ten kidneys in 5 swine had nephrostomy tracts dilated up to 8 mm. The SIS plug was placed into the dilated renal cortex under nephroscopic control. Follow-up arteriograms, retrograde pyelograms, and macroscopic and histologic studies at 24 h (n = 4), 6 weeks (n = 2), and 3 months (n = 4) were performed to evaluate the efficacy of the plug. The SIS plug effectively closed the dilated nephrostomy tract. Follow-up studies showed minimal changes of the kidneys, except for 1 small infarction, regarding inflammatory and foreign-body reactions and progressive scarring of the SIS. SIS plug is effective for occlusion of dilated nephrostomy tract after nephroscopy. Its efficacy should be compared with other therapeutic options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Legacy OpenStudio® SketchUp Plug-in [SWR-07-40]

The Legacy OpenStudio® SketchUp Plug-in makes it easy to create and edit the building geometry in EnergyPlus® input files. This free plug-in also allows you to launch EnergyPlus simulations and view the results without leaving the SketchUp 3D drawing program. Note that active OpenStudio development has moved from the Legacy OpenStudio Plug-in to the more comprehensive OpenStudio suite of tools and libraries found here: https://github.com/NREL/OpenStudio. More information can be found at http://openstudio.net. The OpenStudio Legacy Plug-in has been relaunched as Euclid by Big Ladder Software, the project's new homepage is http://bigladdersoftware.com/projects/euclid/. The Legacy OpenStudio Plug-in was created by the National Renewable Energy Laboratory for the U.S. Department of Energy as an interface to the EnergyPlus simulation engine. Refer to the EnergyPlus webpage at energyplus.gov for an overview of the concept and features. User support is available via the community moderated question and answer resource unmethours.com.

Macumber, Dan↗