Search NASA⌕ Search

SEARCH · Search NASA

Results for “power electronic converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper develops the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for power system integration studies. The Type-5 wind turbine interfaces with the electric grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into the IEEE 14-bus test bed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration

Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.

17 - WIND ENERGY↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators have attracted substantial attention in power system research. However, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper developed the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for the power system integration studies. The Type-5 wind turbine interface to the grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into IEEE 14-bus testbed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Insulation Requirements

Medium voltage SiC devices facilitate direct (without 50/60 Hz transformer) connection of the power electronics converter to the medium voltage grid using simple topology. Compared to the insulation design of medium voltage inductors that have been widely used in the power system, the insulation design of directly connected medium voltage converter filter inductors has more challenges. Although some works has been done discussing that, the grid insulation requirements on converter filter inductors are rarely discussed. This paper introduces the insulation design of a grid-side filter inductor for a 13.8 kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, as well as the local electrical field have been taken into consideration. Experimental tests are provided to validate the design.

Li, Haiguo↗

A Medium Voltage Testbed for the Performance and Function Tests of a 13.8 kV Power Conditioning System Converter

Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.

Li, Haiguo↗

Enhancing EV Charging Station Resilience with Multifunctional Converter Leg Integration

In this paper, a multifunctional converter leg is integrated into an EV charger’s power circuit to enhance EV charging station resilience under power electronics converter device faults and grid outages. In the event of a device fault, it substitutes the failed converter leg, maintaining operation. During a grid outage, it assists the system as a fourth leg to the front-end converter, enabling grid-forming capability to supply power to the charging station critical loads while allowing limited power vehicle charging. The proposed approach’s effectiveness under both front-end power converter device faults and grid outage scenarios are validated through simulation and controller hardware-in-the-loop results.

Pereira Pinto, Joao [ORNL]↗

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched AC-DC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

High temperature steam electrolysis↗

Framework for Supporting Adaptive Droop Based Power Electronic Systems

The electric grid is evolving into an electrical network composed of power electronic converters interconnected with renewable and energy storage technologies. This requires the adoption of more advanced control such as volt/var regulation, fast frequency control, and active power frequency response. This work presents a communication and control framework to support dynamically changing droop control segments that can be used for different optimization schemes. Results are presented to work in a controller hardware in the loop testbed.

Starke, Michael↗

A Cryogenically-Cooled MW Inverter for Electric Aircraft Propulsion

Power electronic converter will be a key enabler for future electrified aircraft propulsion system. In aircraft applications, superconducting technologies such as superconducting motors and generators along with supporting power systems will grow in importance. Utilizing cryogenic cooling for power converter potentially can significantly improve the inverter system efficiency and specific power. This paper presents the cooling, hardware,and testing of a cryogenically-cooled MW inverter developed for electrified aircraft propulsion system. The 1 MVA full load testing with cryogenic cooling is demonstrated. The developed inverter system achieves 18 kVA/kg specific power and 99% efficiency, which provides a promising solution to achieve high power density and efficiency for future electrified aircraft propulsion system.

cryogenically-cooled inverter↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule-14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched ACDC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

08 - HYDROGEN↗

A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗