Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flow solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Towards Efficient Alternating Current Optimal Power Flow Analysis on Graphical Processing Units

We present a solution of sparse ACOPF analysis on GPU. In particular, we discuss the performance bottlenecks and detail our efforts to accelerate the linear solver, a core component of ACOPF that dominates the computational time. ACOPF solutions of two large-scale systems, synthetic Northeast (25,000 buses) and Eastern (70,000 buses) \cite{birchfield2017tamu-cases} on GPU show promising speed-up compared to CPU based solution using a state-of-the-art solver. To our knowledge, this is the first result demonstrating acceleration of sparse ACOPF on GPUs.

Power grid analysis, GPU↗

Stochastic AC optimal power flow: A data-driven approach

There is an emerging need for efficient solutions to stochastic AC Optimal Power Flow (AC-OPF) to ensure optimal and reliable grid operations in the presence of increasing demand and generation uncertainty. Herein this paper presents a highly scalable data-driven algorithm for stochastic AC-OPF that has extremely low sample requirement. The novelty behind the algorithm’s performance involves an iterative scenario design approach that merges information regarding constraint violations in the system with data-driven sparse regression. Compared to conventional methods with random scenario sampling, our approach is able to provide feasible operating points for realistic systems with much lower sample requirements. Furthermore, multiple sub-tasks in our approach can be easily paralleled and based on historical data to enhance its performance and application. We demonstrate the computational improvements of our approach through simulations on different test cases in the IEEE PES PGLib-OPF benchmark library.

42 ENGINEERING↗

Similar solutions for viscous hypersonic flow over a slender three-fourths-power body of revolution

For hypersonic flow with a shock wave, there is a similar solution consistent throughout the viscous and inviscid layers along a very slender three-fourths-power body of revolution The strong pressure interaction problem can then be treated by the method of similarity. Numerical calculations are performed in the viscous region with the edge pressure distribution known from the inviscid similar solutions. The compressible laminar boundary-layer equations are transformed into a system of ordinary differential equations. The resulting two-point boundary value problem is then solved by the Runge-Kutta method with a modified Newton's method for the corresponding boundary conditions. The effects of wall temperature, mass bleeding, and body transverse curvature are investigated. The induced pressure, displacement thickness, skin friction, and heat transfer due to the previously mentioned parameters are estimated and analyzed.

Lin, Chin-Shun↗

Mitigating the Impacts of Uncertain Geomagnetic Disturbances on Electric Grids: A Distributionally Robust Optimization Approach

Severe geomagnetic disturbances (GMDs) increase the magnitude of the electric field on the Earth’s surface (E-field) and drive geomagnetically-induced currents (GICs) along the transmission lines in electric grids. These additional currents can pose severe risks, such as current distortions, transformer saturation and increased reactive power losses, each of which can lead to system unreliability. Today several mitigation actions (e.g., changing grid topology) exist that can reduce the harmful GIC effects on the grids. Making such decisions can be challenging, however, because the magnitude and direction of the E-field are uncertain and non-stationary. In this paper, we model uncertain E-fields using the distributionally robust optimization (DRO) approach that determines optimal transmission grid operations such that the worst-case expectation of the system cost is minimized. We also capture the effect of GICs on the nonlinear AC power flow equations. For solution approaches, we develop an accelerated column-and-constraint generation (CCG) algorithm by exploiting a special structure of the support set of uncertain parameters representing the E-field. Extensive numerical experiments based on “epri-21” and “uiuc-150” systems, designed for GMD studies, demonstrate (i) the computational performance of the accelerated CCG algorithm, (ii) the superior performance of distributionally robust grid operations that satisfy nonlinear, nonconvex AC power flow equations and GIC constraints, in comparison with standard stochastic programming-based methods during the out-of-sample testing.

42 ENGINEERING↗

Control Algorithms Charge Batteries Faster

On March 29, 2011, NASA s Mercury Surface, Space Environment, Geochemistry and Ranging (MESSENGER) spacecraft beamed a milestone image to Earth: the first photo of Mercury taken from orbit around the solar system s innermost planet. (MESSENGER is also the first spacecraft to orbit Mercury.) Like most of NASA s deep space probes, MESSENGER is enabled by a complex power system that allows its science instruments and communications to function continuously as it travels millions of miles from Earth. "Typically, there isn't one particular power source that can support the entire mission," says Linda Taylor, electrical engineer in Glenn Research Center s Power Systems Analysis Branch. "If you have solar arrays and you are in orbit, at some point you re going to be in eclipse." Because of this, Taylor explains, spacecraft like MESSENGER feature hybrid power systems. MESSENGER is powered by a two-panel solar array coupled with a nickel hydrogen battery. The solar arrays provide energy to the probe and charge the battery; when the spacecraft s orbit carries it behind Mercury and out of the Sun s light, the spacecraft switches to battery power to continue operations. Typically, hybrid systems with multiple power inputs and a battery acting alternately as storage and a power source require multiple converters to handle the power flow between the devices, Taylor says. (Power converters change the qualities of electrical energy, such as from alternating current to direct current, or between different levels of voltage or frequency.) This contributes to a pair of major concerns for spacecraft design. "Weight and size are big drivers for any space application," Taylor says, noting that every pound added to a space vehicle incurs significant costs. For an innovative solution to managing power flows in a lightweight, cost-effective manner, NASA turned to a private industry partner.

Source record↗

Fast simultaneous feasibility testing and applications for electrical power grids

Fast simultaneous feasibility testing (SFT) for management of an electrical power grid is achieved through various innovations. The computation problem relates to evaluation of candidate solutions for external power flows into a power grid, with respect to predetermined constraints and contingencies. Storage and computations are reduced by formulating the problem in terms of transactional nodes (e.g. third party connections for generators and loads) instead of the larger number of bus nodes. Further advantages are achieved by precomputing matrices that can be reused across multiple SFT invocations, organizing matrices and operations to reduce storage and computation, and eliminating branches that have no contingency violations. The fast SFT further enables new applications for integrating SFT with a Security-Constrained Unit Commitment (SCUC) optimizer for efficient single pass solutions; operating SFT as a service to multiple SCUC solvers; or integration with Security-Constrained Economic Dispatch (SCED) optimization.

97 MATHEMATICS AND COMPUTING↗

A Bilevel Approach for Identifying the Worst Contingencies for Nonconvex Alternating Current Power Systems

We address the bilevel optimization problem of identifying the most critical attacks to an alternating current (AC) power flow network. The upper-level binary maximization problem consists of choosing an attack that is treated as a parameter in the lower-level defender minimization problem. Instances of the lower-level global minimization problem by themselves are NP-hard due to the nonconvex AC power flow constraints, and bilevel solution approaches commonly apply a convex relaxation or approximation to allow for tractable bilevel reformulations at the cost of underestimating some power system vulnerabilities. Our main contribution is to provide an alternative branch-and-bound algorithm whose upper bounding mechanism (in a maximization context) is based on a reformulation that avoids relaxation of the AC power flow constraints in the lower-level defender problem. Lower bounding is provided with semidefinite programming (SDP) relaxed solutions to the lower-level problem. We establish finite termination with guarantees of either a globally optimal solution to the original bilevel problem, or a globally optimal solution to the SDP-relaxed bilevel problem which is included in a vetted list of upper-level attack solutions, at least one of which is a globally optimal solution to the bilevel problem. We demonstrate through computational experiments applied to IEEE case instances both the relevance of our contribution, and the effectiveness of our contributed algorithm for identifying power system vulnerabilities without resorting to convex relaxations of the lower-level problem. We conclude with a discussion of future extensions and improvements.

97 MATHEMATICS AND COMPUTING↗

Practical Implementation of GPU-based Computing at the Grid Edge for Resilience Scenarios

This paper presents a practical implementation of GPU-accelerated computing at the grid edge to enhance power system resilience through next-generation smart meters. Advanced Metering Infrastructure (AMI) systems rely predominantly on centralized processing architectures, which limit real-time response capabilities during grid disturbances. This work proposes the integration of GPU-enabled computational platforms directly within smart meter to enable local execution support for power system analytics, fault detection algorithms, and optimization routines. The proposed framework uses the Julia programming language to leverage highperformance parallel computing capabilities while maintaining code portability and development efficiency. We use two experimental scenarios to benchmark the computational feasibility of this approach: sparse linear system solutions representative of power flow analyses, and multi-stage production cost simulations incorporating unit commitment and economic dispatch operations. Results demonstrate that computationally intensive power system algorithms, such as those supporting resilience scenario calculations, can be effectively executed at the distribution edge using commercially available embedded GPU hardware. Keywords—GPU acceleration, edge computing, smart meters, grid resilience, AMI, resilience.

De Souza, Reubun [School of Electrical Engineering↗

CFD Code Calibration and Inlet-Fairing Effects On a 3D Hypersonic Powered-Simulation Model

A three-dimensional (3D) computational study has been performed addressing issues related to the wind tunnel testing of a hypersonic powered-simulation model. The study consisted of three objectives. The first objective was to calibrate a state-of-the-art computational fluid dynamics (CFD) code in its ability to predict hypersonic powered-simulation flows by comparing CFD solutions with experimental surface pressure data. Aftbody lower surface pressures were well predicted, but lower surface wing pressures were less accurately predicted. The second objective was to determine the 3D effects on the aftbody created by fairing over the inlet; this was accomplished by comparing the CFD solutions of two closed-inlet powered configurations with a flowing- inlet powered configuration. Although results at four freestream Mach numbers indicate that the exhaust plume tends to isolate the aftbody surface from most forebody flow- field differences, a smooth inlet fairing provides the least aftbody force and moment variation compared to a flowing inlet. The final objective was to predict and understand the 3D characteristics of exhaust plume development at selected points on a representative flight path. Results showed a dramatic effect of plume expansion onto the wings as the freestream Mach number and corresponding nozzle pressure ratio are increased.

Huebner, Lawrence D.↗

Brewster angle-cavity ringdown spectroscopy for low temperature plasma measurements in multiphases

Here we report on the development of a Brewster angle-cavity ringdown spectroscopy (BA-CRDS) system for low temperature plasma diagnostics. The system can measure gas species in solutions, with a detection limit (minimum detectable absorbance) of 9.1 × 10 -5 , which is equivalent to a detection limit of 0.04 parts per billion for measuring OH radicals in water at 308 nm. With higher reflectivity ringdown mirrors and improved design of a Brewster angle cell, the detection limit can potentially be up to 10 -6 or lower. In this exploratory study, the absorption cross sections of HgBr 2 and H 2 O 2 in the aqueous phase at 256 nm are measured to be (1.8 ± 0.1) × 10 -18 cm 2 and (5.2 ± 0.5) × 10 -20 cm 2 , respectively. Furthermore, temporal profiles of absorbance from distilled water, HgBr 2 , and H 2 O 2 solutions when interacting with a helium atmospheric plasma jet are individually characterized at different plasma powers, gas flow rates, and/or solute concentrations. The observed linear temporal profiles of absorbance from the plasma-interacted water suggest formation of H 2 O 2 from plasma-generated OH radicals, while the nonlinear temporal profiles from the plasma-treated HgBr 2 solutions reveal possible removal of HgBr 2 by OH radicals. Our results demonstrate that the new BA-CRDS system is a powerful tool for quantification of reactive plasma species in multiphases or other complex settings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CFD code calibration and inlet-fairing effects on a 3D hypersonic powered-simulation model

A three-dimensional (3D) computational study has been performed addressing issues related to the wind tunnel testing of a hypersonic powered-simulation model. The study consisted of three objectives. The first objective was to calibrate a state-of-the-art computational fluid dynamics (CFD) code in its ability to predict hypersonic powered-simulation flows by comparing CFD solutions with experimental surface pressure dam. Aftbody lower surface pressures were well predicted, but lower surface wing pressures were less accurately predicted. The second objective was to determine the 3D effects on the aftbody created by fairing over the inlet; this was accomplished by comparing the CFD solutions of two closed-inlet powered configurations with a flowing-inlet powered configuration. Although results at four freestream Mach numbers indicate that the exhaust plume tends to isolate the aftbody surface from most forebody flowfield differences, a smooth inlet fairing provides the least aftbody force and moment variation compared to a flowing inlet. The final objective was to predict and understand the 3D characteristics of exhaust plume development at selected points on a representative flight path. Results showed a dramatic effect of plume expansion onto the wings as the freestream Mach number and corresponding nozzle pressure ratio are increased.

Huebner, Lawrence D.↗

Optimal Power Flow in DC Networks with Robust Feasibility and Stability Guarantees

With high penetrations of renewable generation and variable loads, there is significant uncertainty associated with power flows in DC networks such that stability and operational constraint satisfaction are of concern. Most existing DC network optimal power flow (DN-OPF) formulations assume exact knowledge of loading conditions and do not provide stability guarantees. Here, in contrast, this paper studies a DN-OPF formulation which considers both stability and operational constraint satisfaction under uncertainty. The need to account for a range of uncertainty realizations in this paper's robust optimization formulation results in a challenging semi-infinite program (SIP). The proposed solution algorithm reformulates this SIP into a computationally tractable problem by constructing a tight convex inner approximation of the stability set using sufficient conditions for the existence of a feasible and stable power flow solution. Optimal generator set-points are obtained by optimizing over the proposed convex stability set. The validity and effectiveness of the propose algorithm is demonstrated through various DC networks adapted from IEEE test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Surrogate-Based Asynchronous Decomposition Technique for Realistic Security-Constrained Optimal Power Flow Problems

Here we present a decomposition approach for obtaining good feasible solutions for the security-constrained, alternating-current, optimal power flow (SC-AC-OPF) problem at an industrial scale and under real-world time and computational limits. The approach was designed while preparing and participating in ARPA-E’s Grid Optimization Competition (GOC) Challenge 1. The challenge focused on a near-real-time version of the SC-AC-OPF problem, where a base operating point is optimized, taking into account possible single-element contingencies, after which the system adapts its operating point following the response of automatic frequency droop controllers and voltage regulators. Our solution approach for this problem relies on state-of-the-art nonlinear programming algorithms, and it employs nonconvex relaxations for complementarity constraints, a specialized two-stage decomposition technique with sparse approximations of recourse terms and contingency ranking and prescreening. The paper describes and justifies our approach and outlines the features of its implementation, including functions and derivatives evaluation, warm-starting strategies, and asynchronous parallelism. We discuss the results of the independent benchmark of our approach by ARPA-E’s GOC team in Challenge 1, where it was found to consistently produce high-quality solutions across a wide range of network sizes and difficulty, and conclude by outlining future extensions of the approach.

97 MATHEMATICS AND COMPUTING↗

Numerical Analysis of Intra-Cavity and Power-Stream Flow Interaction in Multiple Gas-Turbine Disk-Cavities

A numerical analysis methodology and solutions of the interaction between the power stream and multiply-connected multi-cavity sealed secondary flow fields are presented. Flow solutions for a multi-cavity experimental rig were computed and compared with experimental data of Daniels and Johnson. The flow solutions illustrate the complex coupling between the main-path and the cavity flows as well as outline the flow thread that exists throughout the subplatform multiple cavities and seals. The analysis also shows that the de-coupled solutions on single cavities is inadequate. The present results show trends similar to the T-700 engine data that suggests the changes in the CDP seal altered the flow fields throughout the engine and affected the engine performance.

Athavale, M. M.↗

Optimal Power Dispatch of DGs in Radial and Mesh AC Grids: A Hybrid Solution Methodology between the Salps Swarm Algorithm and Successive Approximation Power Flow Method

In this paper, we address the problem of the optimal power dispatch of Distributed Generators (DGs) in Alternating Current (AC) networks, better known as the Optimal Power Flow (OPF) problem. We used, as the objective function, the minimization of power losses (P loss ) associated with energy transport, which are subject to the set of constraints that compose AC networks in an environment of distributed generation. To validate the effectiveness of the proposed methodology in solving the OPF problem in any network topology, we employed one 10-node mesh test system and three radial text systems: 10, 33, and 69 nodes. In each test system, DGs were allowed to inject 20%, 40%, and 60% of the power supplied by the slack generator in the base case. To solve the OPF problem, we used a master–slave methodology that integrates the optimization method Salps Swarm Algorithm (SSA) and the load flow technique based on the Successive Approximation (SA) method. Moreover, for comparison purposes, we employed some of the algorithms reported in the specialized literature to solve the OPF problem (the continuous genetic algorithm, the particle swarm optimization algorithm, the black hole algorithm, the antlion optimization algorithm, and the Multi-Verse Optimizer algorithm), which were selected because of their excellent results in solving such problems. The results obtained by the proposed solution methodology demonstrate its superiority and convergence capacity in terms of minimization of P loss in both radial and mesh systems. It provided the best reduction in minimum P loss in short processing times and showed excellent repeatability in each test system and scenario under analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.

Giraldo, Jairo↗