Status of the Space Station power system

The major requirements and guidelines that affect the manned Space Station configuration and the power systems are explained. The evolution of the Space Station power system from the NASA program development feasibility phase through the current preliminary design phase is described. Several early station concepts are described and linked to the present concept. The recently completed phase B tradeoff study selections of photovoltaic system technologies are described. The present solar dynamic and power management and distribution systems are also summarized for completeness.

Baraona, Cosmo R.↗

Structural cost optimization of photovoltaic central power station modules and support structure

The results of a comprehensive study of photovoltaic module structural support concepts for photovoltaic central power stations and their associated costs are presented. The objective of the study has been the identification of structural cost drivers. Parametric structural design and cost analyses of complete array systems consisting of modules, primary support structures, and foundations were performed. Area related module cost was found to be constant with design, size, and loading. A curved glass module concept was evaluated and found to have the potential to significantly reduce panel structural costs. Conclusions of the study are: array costs do not vary greatly among the designs evaluated; panel and array costs are strongly dependent on design loading; and the best support configuration is load dependent

Sutton, P. D.↗

Use of satellites to determine optimum locations for solar power stations

Ground measurements of solar radiation are too sparse to determine important mesoscale differences that can be of major significance in solar power station locations. Cloud images in the visual spectrum from the SMS/GOES geostationary satellites are used to determine the hourly distribution of sunshine on a mesoscale in the continental United States excluding Alaska. Cloud coverage and density as a function of time of day and season are considered through the use of digital data processing techniques. Low density cirrus clouds are less detrimental to solar energy collection than other types; and clouds in the morning and evening are less detrimental than those during midday hours of maximum insolation. The seasonal geographic distributions of sunshine are converted to Langleys of solar radiation received at the earth's surface through the use of transform equations developed from long-term measurements of these two parameters at 18 widely distributed stations. The high correlation between measurements of sunshine and radiation makes this possible. The output product will be maps showing the geographic distribution of total solar radiation on the mesoscale which is received at the earth's surface during each season.

Hiser, H. W.↗

Technologies for protection of the Space Station power system surfaces in atomic oxygen environment

Technologies for protecting Space Station surfaces from degradation caused by atomic oxygen are discussed, stressing protection of the power system surfaces. The Space Station power system is described and research concerning the solar array surfaces and radiator surfaces is examined. The possibility of coating the solar array sufaces with a sputter deposited thin film of silicon oxide containing small concentrations of polytetrafluoroethylene is presented. Hexamethyldisiloxane coating for these surfaces is also considered. For the radiator surfaces, possible coatings include silver teflon thermal coating and zinc orthotitanate.

Nahra, Henry K.↗

Effects of design on cost of flat-plate solar photovoltaic arrays for terrestrial central station power applications

The paper examines the impact of module and array designs on the balance-of-plant costs for flat-plate terrestrial central station power applications. Consideration is given to the following types of arrays: horizontal, tandem, augmented, tilt adjusted, and E-W tracking. The life-cycle cost of a 20-year plant life serves as the costing criteria for making design and cost tradeoffs. A tailored code of accounts is developed for determining consistent photovoltaic power plant costs and providing credible photovoltaic system cost baselines for flat-plate module and array designs by costing several varying array design approaches.

Tsou, P.↗

Polk Power Station NGCC Carbon Capture FEED Study

Final Technical Report for Tampa Electric Company's Front-End Engineering Design Study for the implementation of an amine-based Carbon Capture System by ION Clean Energy at the Polk Power Station, Unit 2.

20 FOSSIL-FUELED POWER PLANTS↗

System studies of coal fired-closed cycle MHD for central station power plants

This paper presents a discussion of the closed-cycle MHD results obtained in a recent study of various advanced energy-conversion power systems. The direct coal-fired MHD topping-steam bottoming cycle was established as the current choice for central station power generation. Emphasis is placed on the background assumptions and the conclusions that can be drawn from the closed-cycle MHD analysis. It is concluded that closed-cycle MHD has efficiencies comparable to that of open-cycle MHD. Its cost will possibly be slightly higher than that of the open-cycle MHD system. Also, with reasonable fuel escalation assumptions, both systems can produce lower-cost electricity than conventional steam power plants. Suggestions for further work in closed-cycle MHD components and systems are made.

Zauderer, B.↗

Control/structure interaction methods for space station power systems

The Structural Dynamics Research Corporation and the NASA Lewis Research Center have been working together to develop tools and methods for the analysis of control/structure interaction problems related to the space station power systems. Flexible modes of the solar arrays below 0.1 Hz, suggest that even for relatively slow control systems, the potential for control/structure interaction exists. The emphasis of the effort has been to develop tools which couple NASTRAN's powerful capabilities in structural dynamics with EASY5's powerful capabilities in control systems analysis. One product is an interface software package called CO-ST-IN for COntrol-STructure-INteraction. CO-ST-IN acts to translate data between NASTRAN and EASY5, facilitating the analysis of complex coupled problems. Interfaces to SDRC I-DEAS and MATRIXx are also offered. Beside transferring standard modal information, CO-ST-IN implements a number of advanced methods. These include a modal ordering algorithm that helps eliminate uncontrollable or unobservable modes from the analysis, an implementation of the more accurate mode acceleration algorithm for recovery of element forces and stresses directly in EASY5 and an implementation of fixed interface modes in NASTRAN, which reduces the error in the closed-loop model due to the use of truncated mode sets.

Blelloch, Paul↗

Modeling of Space Station power system components and their interactions

The authors demonstrate that the functional modeling approach is feasible in modeling large-scale spacecraft power systems such as the Space Station electric power system (EPS). The functional models for the solar array sequential shunt unit and the battery charging/discharging unit are presented. The functional modeling approach has also been applied to simulate other major EPS components. The usefulness of this approach in system-level studies has been demonstrated by incorporating these models into a power system model and simulating the system behavior under various conditions. The simulation results are consistent with those obtained experimentally. With larger time step size and reduced model complexity, the computation time required by the functional modeling approach is short. Functional models are effective in simulation studies of system-level issues, especially for large-scale power systems including many power electronic components.

Tam, Kwa-Sur↗

Field Telemetry of Blade-rotor Coupled Torsional Vibration at Matuura Power Station Number 1 Unit

The quasi-modal reduction technique and finite element model (FEM) were used to construct an analytical model for the blade-rotor coupled torsional vibration of a steam turbine generator of the Matuura Power Station. A single rotor test was executed in order to evaluate umbrella vibration characteristics. Based on the single rotor test results and the quasi-modal procedure, the total rotor system was analyzed to predict coupled torsional frequencies. Finally, field measurement of the vibration of the last stage buckets was made, which confirmed that the double synchronous resonance was 124.2 Hz, meaning that the machine can be safely operated. The measured eigen values are very close to the predicted value. The single rotor test and this analytical procedure thus proved to be a valid technique to estimate coupled torsional vibration.

Isii, Kuniyoshi↗

Data and code from: Multivariate bayesian regression model for predicting disposed ash composition at U.S. coal fired power stations

This dataset contains the code and data files needed for implementation of a Multivariate Bayesian Regression model, described in Jin et al. (2025), for the historical prediction of the chemical composition of disposed coal ash at U.S. coal fired power plants as a function of annualized coal purchase data. The integrated coal supply data file (CoalSupplyDataset.csv) represents a compilation of monthly fuel purchase records for the period 1973-2022 at major U.S. power stations. These records were obtained from the U.S. Energy Information Administration. The CSV file also contains, for each coal purchase record, the coal region of the mine as defined by the U.S. Geological Survey. Data entry errors and data gaps in the EIA records were corrected as described in Jin et al. This CSV file represents the integrated coal supply data after corrections were made. The model structure and fitting parameters are encoded in pickle file format (Bayesian.pkl). The model was developed with the coal supply data and coal ash composition data, apportioned according to the Stratified Shuffle Split for training and testing subsets. The model was built using Python and the PyMC library. Reference Publication: Jin, Z.; Huang, J.; Hower, J.C.; Hsu-Kim, H.(2025). Predictive Assessment of the Chemical Composition of Coal Ash in Reserve at U.S. Disposal Sites. Environmental Science & Technology.

Coal ash composition↗

Analysis of measurements from an array of radioxenon samplers near to Hartlepool Nuclear Power Station

As part of a scientific research and development project, the radionuclide fingerprint of an operating advanced gas-cooled reactor 25 (AGR) has been studied across several facets (Goodwin et al., 2024). One part of this project was to deploy an array of 26 radioxenon samplers to the region for a period of around 1 year, to measure any radioxenon emissions from the reactors of the 27 Hartlepool nuclear power station at a range of tens of kilometres away. The array of 3 sensors was operational for around 12 28 months from March 2022 and detected many occurrences of isotopes of radioxenon. Here we provide a detailed analysis and 29 interpretation of the data and where possible, attribution of detections to a source or region. Whilst a key part of this work is to 30 measure any emissions of radioxenon from Hartlepool, this work presents one of the most comprehensive efforts to determine the 31 source of a great number of (mostly) 133Xe detections. A combination of different types of atmospheric dispersion modelling 32 techniques, including the use of stack monitoring data from nearby civil radioxenon-emitting nuclear facilities has enabled the 33 majority of detections to be attributed to one or more possible sources. Whilst emissions from Hartlepool have been detected on 34 the systems, the majority of detections are associated with a medical isotope production facility in Fleurus, Belgium (IRE).

Advanced gas-cooled reactor↗

System studies of coal fired-closed cycle MHD for central station power plants

This paper presents a discussion of the closed cycle MHD results obtained in a recent study of various advanced energy conversion (ECAS) power systems. The study was part of the first phase of this ECAS study. Since this was the first opportunity to evaluate the coal fired closed cycle MHD system, a number of iterations were required to partially optimize the system. The present paper deals with the latter part of the study in which the direct coal fired, MHD topping-steam bottoming cycle was established as the current choice for central station power generation. The emphasis of the paper is on the background assumptions and the conclusions that can be drawn from the closed cycle MHD analysis. The author concludes that closed cycle MHD has efficiencies comparable to that of open cycle MHD and that both systems are considerably more efficient than the other system studies in Phase 1 of the GE ECAS. Its cost will possibly be slightly higher than that of the open cycle MHD system. Also, with reasonable fuel escalation assumptions, both systems can produce lower cost electricity than conventional steam power plants. Suggestions for further work in closed cycle MHD components and systems is made.

Zauderer, B.↗

Space station power system

It is pointed out that space station planning at NASA began when NASA was created in 1958. However, the initiation of the program for a lunar landing delayed the implementation of plans for a space station. The utility of a space station was finally demonstrated with Skylab, which was launched in 1972. In May 1982, the Space Station Task Force was established to provide focus and direction for space station planning activities. The present paper provides a description of the planning activities, giving particular attention to the power system. The initial space station will be required to supply 75 kW of continuous electrical power, 60 kW for the customer and 15 kW for space station needs. Possible alternative energy sources for the space station include solar planar or concentrator arrays of either silicon or gallium arsenide.

Forestieri, A. F.↗

Artificial neural network application for space station power system fault diagnosis

This study presents a methodology for fault diagnosis using a Two-Stage Artificial Neural Network Clustering Algorithm. Previously, SPICE models of a 5-bus DC power distribution system with assumed constant output power during contingencies from the DDCU were used to evaluate the ANN's fault diagnosis capabilities. This on-going study uses EMTP models of the components (distribution lines, SPDU, TPDU, loads) and power sources (DDCU) of Space Station Alpha's electrical Power Distribution System as a basis for the ANN fault diagnostic tool. The results from the two studies are contrasted. In the event of a major fault, ground controllers need the ability to identify the type of fault, isolate the fault to the orbital replaceable unit level and provide the necessary information for the power management expert system to optimally determine a degraded-mode load schedule. To accomplish these goals, the electrical power distribution system's architecture can be subdivided into three major classes: DC-DC converter to loads, DC Switching Unit (DCSU) to Main bus Switching Unit (MBSU), and Power Sources to DCSU. Each class which has its own electrical characteristics and operations, requires a unique fault analysis philosophy. This study identifies these philosophies as Riddles 1, 2 and 3 respectively. The results of the on-going study addresses Riddle-1. It is concluded in this study that the combination of the EMTP models of the DDCU, distribution cables and electrical loads yields a more accurate model of the behavior and in addition yielded more accurate fault diagnosis using ANN versus the results obtained with the SPICE models.

Momoh, James A.↗

The space station power system

The requirements for electrical power by the proposed Space Station Freedom are discussed. The options currently under consideration are examined. The three power options are photovoltaic, solar dynamic, and a hybrid system. Advantages and disadvantages of each system are tabulated. Drawings and artist concepts of the Space Station configuration are provided.

Source record↗

Space station power system requirements

Presented is an overview of the requirements on which the Space Station Electric Power System is based as well as a summary of the design itself. The current design, which is based on silicon photovoltaic arrays, NiH2 batteries, and 20 kHz distribution technology, meets all of the requirements.

Dunning, John W., Jr.↗

Space Station power system requirements

Presented is an overview of the requirements on which the Space Station Electric Power System is based as well as a summary of the design itself. The current design, which is based on silicon photovoltaic arrays, NiH2 batteries, and 20 kHz distribution technology, meets all of the requirements.

Dunning, John W., Jr.↗