Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system stability assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Improving the Reliability and Modal Stability of High Power 870 nm AlGaAs CSP Laser Diodes for Applications to Free Space Communication Systems

The operating characteristics (power-current, beam divergence, etc.) and reliability assessment of high-power CSP lasers is discussed. The emission wavelength of these lasers was optimized at 860 to 880 nm. The operational characteristics of a new laser, the inverse channel substrate planar (ICSP) laser, grown by metalorganic chemical vapor deposition (MOCVD), is discussed and the reliability assessment of this laser is reported. The highlights of this study include a reduction in the threshold current value for the laser to 15 mA and a degradation rate of less than 2 kW/hr for the lasers operating at 60 mW of peak output power.

Connolly, J. C.↗

Control Parameter Sensitivity Study for Inverter-Based-Resource Dominated Grids: A Small Signal Stability Approach and Framework

The growing adoption of renewable energy is driving the prevalence of inverter-based resources (IBRs) within power grids. Future power grids will integrate both grid-following IBRs (GFM-IBRs) and grid-forming IBRs (GFL-IBRs) alongside synchronous generators. Therefore, it is crucial to perform stability studies that account for all components and especially control interactions related to IBRs. Extensive research has performed to study the IBR-related stability, however, the sensitivity study of IBRs' control parameters on system stability has not been adequately studied yet, especially from a systematic way. Therefore, this paper conducts a small signal stability analysis for a generic grid with multiple types of resources and develops an analytical framework for assessing the sensitivity of control parameters affecting stability margins. To achieve that, the non-autonomous reduced-order non-linear dynamic model is developed for a generic power system with multiple synchronous generator-based resources (SGBRs), GFM-IBRs, and GFL-IBRs. Based on the analytic model, a systematic framework for parametric sensitivity on systems' asymptotic stability is developed. A parameter sensitivity analysis based on eigenvalue methods is proposed. The impact of the droop controllers of GFM-IBRs, PQ-dispatch and the PLL controller of GFL-IBR on the system asymptotic stability is discussed. This sensitivity study is aiming to provide deep insights on control parameters' impact on system stability, and gives direction for parameter tuning in case of instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Open Source High Fidelity Modeling Of A Type-5 Wind Turbine Drivetrain

The purpose of this code is to provide a high-fidelity model of Type-5 wind turbine drivetrain for grid integration and transient stability studies. The increasing integration of renewable energy resources in evolving bulk power system (BPS) is impacting the system’s inertia. Type-5 wind turbine generation has the potential to behave like a traditional synchronous generator and can help mitigate the aforementioned impact. A hydraulic torque converter (TC) and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine unit. A generic and high-fidelity model of a Type-5 wind turbine drivetrain is not openly and widely available for grid integration and transient stability studies. This hinders appropriate assessment of Type-5 wind power plant's contribution to the BPS resilience. This work develops and validates a TC model based on those generally used in automobile's transmission system.

Hussain, Tanveer↗

Operational resilience metrics for power systems with penetration of renewable resources

Abstract Modern power grid is evolving towards carbon neutrality by deploying increasing amount of renewable energy resources. However, the impact of renewable generation on power system planning and operation is not sufficiently investigated, especially the capability of renewable penetrated power systems to resist and recover from major disturbances, which is a critical concern for system operators. Novel metrics and evaluation methodologies are needed to depict systems’ ability in response to events caused by natural disasters, and quantitatively evaluate system performance in various time scales. In this paper, operational resilience metrics are proposed for power systems with penetration of renewable energy resources based on transient stability principles. A systematic methodology is proposed to quantitatively assess the evolution of system performance during various stages of the disaster process. Based on the proposed metrics, a resilience‐oriented disaster management strategy is designed and validated using the modified IEEE 39‐bus test system. The simulation results demonstrate the validity of the proposed metrics and strategy, and show that the system resilience is enhanced during the mitigation of fault conditions.

Gui, Jianzhong↗

Investigation of the Use of Dynamic Probabilistic Risk Assessment Methodologies for Identifying Digital I&C System Common Cause Failures

Digital Instrumentation and Control (I&C) systems have a key role in nuclear power plants in the upgrade of aging analog systems. Digital systems improve plant safety and reliability through features such as increased hardware reliability and stability and improved failure detection capability. There is no consensus on which of the current probabilistic risk assessment methods are most suitable for use in the reliability analysis of digital I&C systems. While the traditional event-tree/fault-tree (ET/FT) approach is still used for their reliability modeling, there are concerns regarding this approach in properly accounting for dynamic interactions among system components since potentially significant dependencies among failure events may not be identified and/or their likelihood may not be properly quantified. Dynamic methodologies are expected to provide a much more accurate representation of probabilistic evolution of the I&C systems in time due to their capability to more properly account for complex interactions than the static approach. The applicability of dynamic PRA methodologies for digital I&C system is investigated using the criteria presented in the NUREG/CR-6901, and the comparisons made in NUREG/CR-6901 are updated in light of the latest studies. The Dynamic Event Tree (DET) approach has been identified as one of the top dynamic methods when evaluated against the requirements for the reliability modeling of digital I&C systems. The DET method is a strong candidate for integration into existing PRA studies, as it bears many similarities to the traditional ET approach. In this study, the DET approach has been applied to the Plant Protection System of the APR1400 design, and the results are compared to results from its available traditional ET/FT analysis. Possible approaches to evaluate and quantify the effects of common cause failures on system safety using dynamic methods are also examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physiochemical Machine Learning Models Predict Operational Lifetimes of CH3NH3PbI3 Perovskite Solar Cells

Halide perovskites are promising photovoltaic (PV) materials with the potential to lower the cost of electricity and greatly expand the penetration of PV if they can demonstrate long-term stability under illumination in the presence of moisture and oxygen. The solar cell service lifetime as quantified by the T80 (the time required for the power conversion efficiency to drop to 80% of its starting value) is a useful metric to assess stability. The T80 for utility, commercial, or residential PV systems needs to be several decades in order to yield low-cost electricity, and thus it is not practical to directly measure the T80. It would be useful if T80 could be predicted from the initial dynamics of a solar cell’s performance, but until now no models have been developed to forecast T80. In this work, we report the development of machine learning models to predict T80 of ITO/NiOx/CH3NH3PbI3/C60/BCP/Ag solar cells operating at maximum power point under 1-sun equivalent photon flux in air at varying temperatures and relative humidities. Efficiency losses are driven by short-circuit current and fill factor, indicating that chemical decomposition of the perovskite is a major contributor to degradation. Spatial patterns evident from in situ dark field optical microscopy suggest that the electric field gradient at device edges plays a significant role in perovskite decomposition, along with photochemical reactions with O2 and H2O. Models are trained using a menu of features from three distinct categories: (i) features based on measurements of the initial rates of change of device parameters, (ii) features based on the ambient conditions during operation (temperature, & partial pressure of H2O), and (iii) features based on underlying physics and chemistry. We show that a theory-based physiochemical feature derived from a model of the chemical reaction kinetics of the rate of degradation of the CH3NH3PbI3 is particularly valuable for prediction. This physiochemical feature was selected as the first or second most dominant feature in the best performing models. With a dataset consisting of 45 accelerated degradation experiments with T80 that range over a factor of 30, the model predicts T80 with an accuracy of about 40% (|predicted T80 - observed T80| / observed T80) on samples not used in training. This hybrid ML approach should be effective when applied to other compositions, device architectures, and advanced packaging schemes.

14 SOLAR ENERGY↗

Physiochemical Machine Learning Models Predict Operational Lifetimes of CH3NH3PbI3 Perovskite Solar Cells

Halide perovskites are promising photovoltaic (PV) materials with the potential to lower the cost of electricity and greatly expand the penetration of PV if they can demonstrate long-term stability under illumination in the presence of moisture and oxygen. The solar cell service lifetime as quantified by the T80 (the time required for the power conversion efficiency to drop to 80% of its starting value) is a useful metric to assess stability. The T80 for utility, commercial, or residential PV systems needs to be several decades in order to yield low-cost electricity, and thus it is not practical to directly measure the T80. It would be useful if T80 could be predicted from the initial dynamics of a solar cell’s performance, but until now no models have been developed to forecast T80. In this work, we report the development of machine learning models to predict T80 of ITO/NiOx/CH3NH3PbI3/C60/BCP/Ag solar cells operating at maximum power point under 1-sun equivalent photon flux in air at varying temperatures and relative humidities. Efficiency losses are driven by short-circuit current and fill factor, indicating that chemical decomposition of the perovskite is a major contributor to degradation. Spatial patterns evident from in situ dark field optical microscopy suggest that the electric field gradient at device edges plays a significant role in perovskite decomposition, along with photochemical reactions with O2 and H2O. Models are trained using a menu of features from three distinct categories: (i) features based on measurements of the initial rates of change of device parameters, (ii) features based on the ambient conditions during operation (temperature, & partial pressure of H2O), and (iii) features based on underlying physics and chemistry. We show that a theory-based physiochemical feature derived from a model of the chemical reaction kinetics of the rate of degradation of the CH3NH3PbI3 is particularly valuable for prediction. This physiochemical feature was selected as the first or second most dominant feature in the best performing models. With a dataset consisting of 45 accelerated degradation experiments with T80 that range over a factor of 30, the model predicts T80 with an accuracy of about 40% (|predicted T80 - observed T80| / observed T80) on samples not used in training. This hybrid ML approach should be effective when applied to other compositions, device architectures, and advanced packaging schemes.

14 SOLAR ENERGY↗

High power phase locked laser oscillators

The feasibility of mechanizing an adaptive array of independent laser oscillators for generation of a high power coherent output was experimentally investigated. Tests were structured to evaluate component/system requirements for delivery of energy to a low-earth orbit satellite. Initial experiments addressed the control issues of phase locking unstable resonators at low power levels. A successful phase lock demonstration formed the basis for the design and fabrication of the high power, water-cooled, control mirror subsequently installed in the NASA LeRC high power laser. Tests were performed to characterize the operational limits of the laser system and included quantitative assessment of the frequency stability, noise sources, and optical properties of the beam.

Hayes, C. L.↗

Advanced controls for stability assessment of solar dynamics space power generation

In support of the power requirements for the Space Station Alpha (SSA), a joint program by the U.S. and Russia for a permanently manned space station to be launched into orbit by 1998, a robust control scheme is needed to assure the stability of the rotating machines that will be integrated into the power subsystem. A framework design and systems studies for modeling and analysis is presented. It employs classical d-q axes machine model with voltage/frequency dependent loads. To guarantee that design requirements and necessary trade studies are done, a functional analysis tool CORE is used for the study. This provides us with different control options for stability assessment. Initial studies and recommendations using advanced simulation tools are also presented. The benefits of the stability/control scheme for evaluating future designs and power management are discussed.

Momoh, James A.↗

Oscillatory Spreading and Inertia in Power Grids

The increase in variable renewable generators (VRGs) in power systems has altered the dynamics from a historical experience. VRGs introduce new sources of power oscillations, and the stabilizing response provided by synchronous generators (SGs, e.g., natural gas, coal, etc.), which help avoid some power fluctuations, will lessen as VRGs replace SGs. These changes have led to the need for new methods and metrics to quickly assess the likely oscillatory behavior for a particular network without performing computationally expensive simulations. This work studies the impact of a critical dynamical parameter - the inertia value - on the rest of a power system's oscillatory response to representative VRG perturbations. We use a known localization metric in a novel way to quantify the number of nodes responding to a perturbation and the magnitude of those responses. This metric allows us to relate the spread and severity of a system's power oscillations with inertia. We find that as inertia increases, the system response to node perturbations transitions from localized (only a few close nodes respond) to delocalized (many nodes across the network respond). We introduce a heuristic computed from the network Laplacian to relate this oscillatory transition to the network structure. We show that our heuristic accurately describes the spread of oscillations for a realistic power-system test case. Using a heuristic to determine the likely oscillatory behavior of a system given a set of parameters has wide applicability in power systems, and it could decrease the computational workload of planning and operation.

dynamical systems↗

Adding power of artificial intelligence to situational awareness of large interconnections dominated by inverter‐based resources

Abstract Large‐scale power systems exhibit more complex dynamics due to the increasing integration of inverter‐based resources (IBRs). Therefore, there is an urgent need to enhance the situational awareness capability for better monitoring and control of power grids dominated by IBRs. As a pioneering Wide‐Area Measurement System, FNET/GridEye has developed and implemented various advanced applications based on the collected synchrophasor measurements to enhance the situational awareness capability of large‐scale power grids. This study provides an overview of the latest progress of FNET/GridEye. The sensors, communication, and data servers are upgraded to handle ultra‐high density synchrophasor and point‐on‐wave data to monitor system dynamics with more details. More importantly, several artificial intelligence (AI)‐based advanced applications are introduced, including AI‐based inertia estimation, AI‐based disturbance size and location estimation, AI‐based system stability assessment, and AI‐based data authentication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Validation of CNN-Based Surrogate Models for Inverter-Based Resources in Open-Source Solvers

Traditionally, distribution system planning has focused on steady-state analyses, with limited consideration of dynamic behavior. However, as large or medium-scale inverter-based resources (IBRs), particularly grid-following (GFL) inverters in commercial or industry buildings, become more prevalent, understanding their dynamic impact is essential for grid planning and operation. This article presents an innovative deep-learning (DL)-approach using convolutional neural networks technique to model the GFL inverters. Developed from real grid-tied commercial IBR transient data, these dynamic DL models overcome proprietary constraints by requiring minimal knowledge of internal converter physics while maintaining high accuracy and flexibility. To demonstrate their applicability, the models were incorporated into GridLAB-D, an open-source, three-phase distribution analysis tool. This integration enables dynamic simulations of large-scale distribution networks with high IBR penetration stability analysis. Rigorous testing and validation, aligned with industry standards, confirmed the reliability and efficiency of this approach, paving the way for enhanced planning and operational assessments of modern power systems.

Deep-learning↗

Creep behavior of tungsten/niobium and tungsten/niobium-1 percent zirconium composites

The creep behavior and microstructural stability of tungsten fiber reinforced niobium and niobium 1 percent zirconium was determined at 1400 and 1500 K in order to assess the potential of this material for use in advanced space power systems. The creep behavior of the composite materials could be described by a power law creep equation. A linear relationship was found to exist between the minimum creep rate of the composite and the inverse of the composite creep rupture life. The composite materials had an order of magnitude increase in stress to achieve 1 percent creep strain and in rupture strength at test temperatures of 1400 and 1500 K compared to unreinforced material. The composite materials were also stronger than the unreinforced materials by an order of magnitude when density was taken into consideration. Results obtained on the creep behavior and microstructural stability of the composites show significant potential improvement in high temperature properties and mass reduction for space power system components.

Petrasek, Donald W.↗

A Scalable Transmission and Distribution Co-simulation Platform for IBR-heavy Power Systems

The integration of Inverter-Based Resources (IBRs) into power systems, including both transmission and distribution networks, poses challenges for studying grid dynamic behaviours under various operating conditions and system events. This paper addresses the urgent need to investigate the influence of IBRs on grid dynamics, and their potential to enhance power system reliability and resilience. We propose a flexible, scalable transmission and distribution co-simulation platform, using opensource tools only for assessing the impact of grid-following (GFL) and grid-forming (GFM) IBRs on dynamic stability at various renewable penetration levels (up to 100%). This platform enables researchers to explore different contingencies at transmission, distribution, or both, providing a comprehensive evaluation of grid status. A series of case studies, including both small and large T&D systems with varying GFL/GFM configurations and contingencies, have been conducted. The results not only robustly validate our co-simulation framework, but also provide invaluable insights for effective IBR management in the power grid.

grid management↗

From Event Data to Wind Power Plant DQ Admittance and Stability Risk Assessment

This paper presents a dynamic event data-based stability risk assessment method for power grids with high penetrations of inverter-based resources (IBRs). This method relies on obtaining the IBRs' DQ admittance through dynamic event data and computing the system's eigenvalues based on the admittance models. Two critical technologies are employed in this research, including time-domain and frequency-domain data fitting and dq-frame voltage and current signal derivation. The first technology is key to obtaining the s-domain expressions from the transient response data, and the s-domain DQ admittance model from the frequency-domain measurements. The second technology is key to obtaining the dq-frame voltage and current signals from either the three-phase instantaneous measurements or the phasor measurement unit (PMU) data. The method is illustrated using data generated from a Type-4 wind power plant modeled in PSCAD. This paper demonstrates the technical feasibility of the proposed approach.

17 WIND ENERGY↗

System Modeling of a Lunar Molten Regolith Electrolysis Plant

Introduction: In-Situ Resource Utilization (ISRU) is the process of extracting local resources to produce commodities for propulsion, life support systems, and off-planet construction rather than transporting consumables from Earth. Molten Regolith Electrolysis (MRE) is a novel ISRU method of extracting oxygen gas and metal alloy from lunar regolith. The MRE process involves placing lunar regolith between two electrodes, through which current is passed, to melt the regolith and reduce the metal oxide constituents by direct electrolysis (e.g. FeO, SiO2, MgO, Al2O3) into oxygen gas and metal alloys. The oxygen is liquefied and used as propellant for landers, while the metals (e.g. Ferro-alloys) are further processed and used in structural building materials and parts manufacturing. A system model was developed that accounted for the major processes of an MRE plant (from excavation of raw materials to storage of products) to assess the feasibility of a lunar MRE plant. The System Engineering and Integration (SE&I) ISRU Modeling and Analysis (SIMA) team utilized its previously documented system sizing model, the Mission Analysis and Integration Tool (MAIT) [1] as framework of the system model. MAIT uses MATLAB/Simulink to integrate subsystem models into a complete system model of the MRE plant. Total mass, volume, and power requirements were computed for numerous iterations of a MRE plant. System Model: Figure 1: MRE Plant Block Diagram The regolith excavation model determines the mass and power needed to excavate sufficient regolith. The preheating auger initiates the regolith heating process before regolith enters the MRE re-actor to reduce the energy required to turn the solid into a molten liquid. The MRE reactor is modeled in COMSOL Multiphysics and based on the research by Dominguez, Sibille, and Schreiner [2, 3, 4]. This preliminary reactor model provides an accurate calculation of thermal equilibrium during electrochemical operation of the reactor system to assess the optimal mass and power required to process the inlet flow of regolith. The model also computes the outlet flowrates of oxygen and molten products. For this analysis, the primary components of the metal alloy considered were iron and silicon. The oxygen is then purified using an Yttrium Stabilized Zirconia (YSZ) electrode, followed by liquefaction using a 90K cryocooler to be stored as liquid oxygen in insulated cylindrical tanks. In future iterations of the system model, the molten metal tapped from the MRE reactor will undergo additional processing or refinement. However, downstream handling of metals is currently a technology gap that is missing a high TRL subsystem model. Therefore, for this analysis, the accumulated metal alloy stream terminates after leaving the MRE reactor. Study Goals: This analysis investigates multiple input variables to the system to determine the sensitivity of a (near) complete plant at full-scale. This preliminary investigation ran parametric sweeps on the MRE reactor geometry, electrical current supply, layers of multi-layer insulation (MLI) on the reactor, size of the electrodes in the oxygen purification model, and regolith composition (based on landing site location). Three production targets of oxygen (1,000, 10,000, and 50,000 kg/yr) were investigated for this analysis. The parametric sweeps conducted in this analysis provide valuable insight into the expected impact of the various model inputs on plant size. This information can be used to identify the most critical components of the plant and guide future decisions on allocating funding for research and development, providing subsystem developers with appropriate interfaces with downstream and upstream processes, and assessing the overall feasibility of MRE when compared to other ISRU plants. References: [1] Carlson, A. et al. (2024) ICES, ICES-2024-53. [2] Dominguez, D.A., and Sibille, L. (2011) AIAA, AIAA-2011-700. [3] Schreiner, S.S. (2015) MIT, Dissertation. [4] Schreiner, S.S. et al. (2016) ASR, 57(7), pp.1585-1603.

ISRU↗

Comparative Evaluation of the Single-Phase Shift and Extended-Phase Shift Control for Isolated DC-DC Converter

Abstract: This paper presents a comparative evaluation of the Single-Phase Shift (SPS) and Extended-Phase Shift (EPS) controls for the isolated DC-DC Converter. The analysis is based on the power regulation range, flexibility of operation, current stress on power devices, system efficiency while focusing on the issue of backflow power, control complexity, design and implementation overhead, and stability of the entire system. It is also examined how the backflow influences power circulation and increases current stress. Here, the Dual Active Bridge (DAB) Converter is employed to assess the performance of the control methods. Compared to SPS control, EPS offers a wider power regulation range, greater flexibility, lower current stress, and better system efficiency. However, EPS has increased control complexity, design and implementation overhead, and often requires sophisticated feedback control loops. The comparison is made through mathematical modeling of power transfer, backflow, and current stress. Simulation results validate the comparative analysis presented.

Amir, Aamir [The University of Alabama (UA)]↗