Search NASA⌕ Search

SEARCH · Search NASA

Results for “power usage effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

TEP Power Partners Project [Tucson Electric Power]

The Arizona Governor’s Office of Energy Policy, in partnership with Tucson Electric Power (TEP), Tendril, and Next Phase Energy (NPE), formed the TEP Power Partners pilot project to demonstrate how residential customers could access their energy usage data and third party applications using data obtained from an Automatic Meter Reading (AMR) network. The project applied for and was awarded a Smart Grid Data Access grant through the U.S. Department of Energy. The project participants’ goal for Phase I is to actively engage 1,700 residential customers to demonstrate sustained participation, reduction in energy usage (kWh) and cost ($), and measure related aspects of customer satisfaction. This Demonstration report presents a summary of the findings, effectiveness, and customer satisfaction with the 15-month TEP Power Partners pilot project. The objective of the program is to provide residential customers with energy consumption data from AMR metering and empower these participants to better manage their electricity use. The pilot recruitment goals included migrating 700 existing customers from the completed Power Partners Demand Response Load Control Project (DRLC), and enrolling 1,000 new participants. Upon conclusion of the project on November 19, 2013; 1,390 Home Area Networks (HANs) were registered; 797 new participants installed a HAN; Survey respondents’ are satisfied with the program and found value with a variety of specific program components; Survey respondents report feeling greater control over their energy usage and report taking energy savings actions in their homes after participating in the program; On average, 43 % of the participants returned to the web portal monthly and 15% returned weekly; and An impact evaluation was completed by Opinion Dynamics and found average participant savings for the treatment period1 to be 2.3% of their household use during this period.2 In total, the program saved 163 MWh in the treatment period of 2013.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced efficiency of large-area dye-sensitized solar cells by light-scattering effect using multilayer TiO2 photoanodes

Highlights: • DSSCs with an active area of 100.6 cm{sup 2} and light-scattering layers are fabricated. • The light-scattering effect is shown to enhance the light absorption in the red part of the solar spectrum. • The light-scattering effect is more important than the dye adsorption capacity for TiO{sub 2} photoanodes with same thickness. • The highest power conversion efficiency of 7.52% has been obtained by the DSSC with optimized conditions. - Abstract: In order to reduce the usage of photoactive dye and improve light harvesting by the photoanode of dye-sensitized solar cells (DSSCs), TiO{sub 2} scatting layers were introduced. We have investigated the light-scattering effect in large-area DSSCs with an active area of 100.6 cm{sup 2} that contain diffusing or reflective layers. The result shows that the light-scattering effect is more important than the dye adsorption capacity for the light harvesting property of TiO{sub 2} photoanodes with same thickness, and the light-scattering effect is shown to enhance the light absorption in the red part of the solar spectrum. The highest power conversion efficiency of 7.52% has been obtained by the cell with optimized high dye adsorption layer and high light-scattering layer, which is 9.5% higher than that of the cell without the light-scattering layer (6.87%).

14 SOLAR ENERGY↗

Emissions of Trace Gases and Particles from Two Ships in the Southern Atlantic Ocean

Measurements were made of the emissions of particles and gases from two diesel-powered ships in the southern Atlantic Ocean off the coast of Namibia. The measurements are used to derive emission factors from ships of three species not reported previously, namely, black carbon, accumulation-mode particles, and cloud condensation nuclei (CCN), as well as for carbon dioxide, carbon monoxide (CO), methane (CH4), non-methane hydrocarbons, sulfur dioxide (SO2), nitrogen oxides (NOx), and condensation nuclei. The effects of fuel grade and engine power on ship emissions are discussed. The emission factors are combined with fuel usage data to obtain estimates of global annual emissions of various particles and gases from ocean-going ships. Global emissions of black carbon, accumulation- mode particles, and CCN from ocean-going ships are estimated to be 19-26 Gg yr(sup -1), (4.4-6.1) x 10(exp 26) particles yr(sup -1), and (1.0-1.5) x l0(exp 26) particles yr(sup -1), respectively. Black carbon emissions from ocean-going ships are approximately 0.2% of total anthropogenic emissions. Emissions of NOx and SO2 from ocean-going ships are approximately 10-14% and approximately 3-4%, respectively, of the total emissions of these species from the burning of fossil fuels, and approximately 40% and approximately 70%, respectively, of the total emissions of these species from the burning of biomass. Global annual emissions of CO and CH4 from ocean-going ships are approximately 2% and approximately 2-5%, respectively, of natural oceanic emissions of these species.

Sinha, Parikhit↗

Discovery of Signatures, Anomalies, and Precursors in Synchrophasor Data with Matrix Profile and Deep Recurrent Neural Networks (Final Project Report)

The widespread deployment of phasor measurement unit (PMU) across the U.S. together with the burgeoning machine learning technology made it possible to develop data-driven PMU data analytics to improve grid security and reliability in a more insightful and effective manner. Although PMU applications have been explored for over a decade, the representative PMU usage is limited to the bulk power system monitoring mainly due to the data integrity issues associated with PMUs (typically missing, fragmented, and wrongly amplified data). To forge a breakthrough on this stalemate and embrace PMUs for power system control and protection as well, we applied various advanced machine learning and big data analysis technology to the power system event detection and classification as the first step toward the power system control and protection pertaining to grid security enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Adaptive real-time methodology for optimizing energy-efficient computing

Dynamic voltage and frequency scaling (DVFS) is an effective way to reduce energy and power consumption in microprocessor units. Current implementations of DVFS suffer from inaccurate modeling of power requirements and usage, and from inaccurate characterization of the relationships between the applicable variables. A system and method is proposed that adjusts CPU frequency and voltage based on run-time calculations of the workload processing time, as well as a calculation of performance sensitivity with respect to CPU frequency. The system and method are processor independent, and can be applied to either an entire system as a unit, or individually to each process running on a system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive real-time methodology for optimizing energy-efficient computing

Dynamic voltage and frequency scaling (DVFS) is an effective way to reduce energy and power consumption in microprocessor units. Current implementations of DVFS suffer from inaccurate modeling of power requirements and usage, and from inaccurate characterization of the relationships between the applicable variables. A system and method is proposed that adjusts CPU frequency and voltage based on run-time calculations of the workload processing time, as well as a calculation of performance sensitivity with respect to CPU frequency. The system and method are processor independent, and can be applied to either an entire system as a unit, or individually to each process running on a system.

97 MATHEMATICS AND COMPUTING↗

Near-term hybrid vehicle program, phase 1. Appendix B: Design trade-off studies

The relative attractiveness of various hybrid/electric power train configurations and electrical and mechanical drive-line components was studied. The initial screening was concerned primarily with total vehicle weight and economic factors and identified the hybrid power train combinations which warranted detailed evaluation over various driving cycles. This was done using a second-by-second vehicle simulation program which permitted the calculations of fuel economy, electricity usage, and emissions as a function of distance traveled in urban and highway driving. Power train arrangement possibilities were examined in terms of their effect on vehicle handling, safety, serviceability, and passenger comfort. A dc electric drive system utilizing a separately excited motor with field control and battery switching was selected for the near term hybrid vehicle. Hybrid vehicle simulations showed that for the first 30 mi (the electric range of the vehicle) in urban driving, the fuel economy was 80 mpg using a gasoline engine and 100 mpg using a diesel engine. In urban driving the hybrid would save about 75% of the fuel used by the conventional vehicle and in combined urban/highway driving the fuel saving is about 50%.

Source record↗

Hybrid power plants: An effective way of decreasing loss-of-load expectation

Diversifying variable renewable resources by combining wind, solar photovoltaic, and battery assets in a hybrid power plant can increase renewable energy usage efficiency and improve system flexibility, particularly in distributed energy systems. However, the resilience impact of these systems, particularly outage mitigation, can be difficult to quantify due to uncertainty in resource, energy demand, and outage occurrence. Here, this study outlines a framework to quantify the incremental benefit of hybrid power plant assets for reducing loss-of-load expectation during random outage events. Hybrid power plant performance during outages (considering varying duration and severity) is simulated using a Monte Carlo methodology to reflect uncertainty associated with renewable resource, load demand, and outage timing. Results demonstrate the additional incremental value from increasingly hybrid designs, in which relative capacities of wind, solar photovoltaic, and storage assets contribute to lower loss-of-load expectation than the constituent technologies would alone. The value of added wind or solar capacity increases as the plant composition approaches an equal split. The value of added battery capacity depends on the outage duration and severity, but the first 50 MWh of added storage capacity is the most valuable for reducing the loss-of-load expectation for all plant designs.

14 SOLAR ENERGY↗

Diversity Strategies for Nuclear Power Plant Instrumentation and Control Systems

This report presents the technical basis for establishing acceptable mitigating strategies that resolve diversity and defense-in-depth (D3) assessment findings and conform to U.S. Nuclear Regulatory Commission (NRC) requirements. The research approach employed to establish appropriate diversity strategies involves investigation of available documentation on D3 methods and experience from nuclear power and nonnuclear industries, capture of expert knowledge and lessons learned, determination of best practices, and assessment of the nature of common-cause failures (CCFs) and compensating diversity attributes. The research described in this report does not provide guidance on how to determine the need for diversity in a safety system to mitigate the consequences of potential CCFs. Rather, the scope of this report provides guidance to the staff and nuclear industry after a licensee or applicant has performed a D3 assessment per NUREG/CR-6303 and determined that diversity in a safety system is needed for mitigating the consequences of potential CCFs identified in the evaluation of the safety system design features. Succinctly, the purpose of the research described in this report was to answer the question, 'If diversity is required in a safety system to mitigate the consequences of potential CCFs, how much diversity is enough?' The principal results of this research effort have identified and developed diversity strategies, which consist of combinations of diversity attributes and their associated criteria. Technology, which corresponds to design diversity, is chosen as the principal system characteristic by which diversity criteria are grouped to form strategies. The rationale for this classification framework involves consideration of the profound impact that technology-focused design diversity provides. Consequently, the diversity usage classification scheme involves three families of strategies: (1) different technologies, (2) different approaches within the same technology, and (3) different architectures within the same technology. Using this convention, the first diversity usage family, designated Strategy A, is characterized by fundamentally diverse technologies. Strategy A at the system or platform level is illustrated by the example of analog and digital implementations. The second diversity usage family, designated Strategy B, is achieved through the use of distinctly different technologies. Strategy B can be described in terms of different digital technologies, such as the distinct approaches represented by general-purpose microprocessors and field-programmable gate arrays. The third diversity usage family, designated Strategy C, involves the use of variations within a technology. An example of Strategy C involves different digital architectures within the same technology, such as that provided by different microprocessors (e.g., Pentium and Power PC). The grouping of diversity criteria combinations according to Strategies A, B, and C establishes baseline diversity usage and facilitates a systematic organization of strategic approaches for coping with CCF vulnerabilities. Effectively, these baseline sets of diversity criteria constitute appropriate CCF mitigating strategies for digital safety systems. The strategies represent guidance on acceptable diversity usage and can be applied directly to ensure that CCF vulnerabilities identified through a D3 assessment have been adequately resolved. Additionally, a framework has been generated for capturing practices regarding diversity usage and a tool has been developed for the systematic assessment of the comparative effect of proposed diversity strategies (see Appendix A).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Stochastic Multi-Criteria Decision-Making Algorithm for Dynamic Load Prioritization in Grid-Interactive Efficient Buildings

Increasing deployment of advanced sensing, controls, and communication infrastructure enables buildings to provide services to the power grid, leading to the concept of grid-interactive efficient buildings. Since occupant activities and preferences primarily drive the availability and operational flexibility of building devices, there is a critical need to develop occupant-centric approaches that prioritize devices for providing grid services, while maintaining the desired end-use quality of service. In this paper, we present a decision-making framework that facilitates a building owner/operator to effectively prioritize loads for curtailment service under uncertainties, while minimizing any adverse impact on the occupants. The proposed framework uses a stochastic (Markov) model to represent the probabilistic behavior of device usage from power consumption data, and a load prioritization algorithm that dynamically ranks building loads using a stochastic multi-criteria decision-making algorithm. The proposed load prioritization framework is illustrated via numerical simulations in a residential building use-case, including plug-loads, air-conditioners, and plug-in electric vehicle chargers, in the context of load curtailment as a grid service. Suitable metrics are proposed to evaluate the closed-loop performance of the proposed prioritization algorithm under various scenarios and design choices. Scalability of the proposed algorithm is established via computational analysis, while time-series plots are used for intuitive explanation of the ranking choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SBLLmalloc V1.0

Memory size has long limited large-scale applications on high-performance computing (HPC) systems. Increasing core counts per chip and power density constraints, which limit the number of DIMMs per node, have exacerbated this problem. Mechanisms to manage memory usage - preferably transparently - more efficiently could increase effective DRAM capacity and, thus, the benefit of multicore similarity. These data regions occupy multiple physical locations within a multicore node and thus offer a potential savings in memory capacity. These data, primarily residing in heap, are quite dynamic, which makes them difficult to manage statically. SBLLmalloc is a memory allocation library that automatically identifies the replicated memory blocks and merges them into a single copy. SBLLmalloc does not require application or OS changes since we implement it as a user-level library that can be linked at runtime. SBLLmalloc provides the capability to run larger problems using the same hardware configuration in multicore nodes. SBLLmalloc has been implemented for Linux clusters.

Source record↗

SBLLmalloc V1.0

Memory size has long limited large-scale applications on high-performance computing (HPC) systems. Increasing core counts per chip and power density constraints, which limit the number of DIMMs per node, have exacerbated this problem. Mechanisms to manage memory usage - preferably transparently - more efficiently could increase effective DRAM capacity and, thus, the benefit of multicore similarity. These data regions occupy multiple physical locations within a multicore node and thus offer a potential savings in memory capacity. These data, primarily residing in heap, are quite dynamic, which makes them difficult to manage statically. SBLLmalloc is a memory allocation library that automatically identifies the replicated memory blocks and merges them into a single copy. SBLLmalloc does not require application or OS changes since we implement it as a user-level library that can be linked at runtime. SBLLmalloc provides the capability to run larger problems using the same hardware configuration in multicore nodes. SBLLmalloc has been implemented for Linux clusters.

Source record↗

Advancements in Manufacturing of High-Performance Perovskite Solar Cells and Modules Using Printing Technologies

Perovskite photovoltaic technology carries immense opportunity for the solar industries because of its remarkable efficiency and prospect for cost-effective production. However, the successful deployment of perovskite solar modules (PSMs) in the solar market necessitates tackling stability-based obstacles, scalability, and environmental considerations. This paper unveils a comprehensive examination of the cutting-edge advancements in the manufacturing of perovskite solar cells (PSCs) and modules, with an emphasis on high-speed, large-area printing. The paper underscores the substantial progress achieved in printed PSCs and PSMs, demonstrating promising electrical performance and long-term device durability. This review paper categorizes printing techniques compatible with large-area high-speed manufacturing into three distinct families: blade coating, slot die coating, and screen printing, as these common printing practices offer precise control, scalability, cost-effectiveness, high resolution, and efficient material usage. Additionally, this paper presents an in-depth investigation and comparison of superior PSCs and PSMs fabricated by printing on power conversion efficiency (PCE), stability, and scalability.

14 SOLAR ENERGY↗

SEE and TID extension testing of the Xilinx XQR18V04 4Mbit radiation hardened configuration PROM

The XQR18V04 was evaluated for single event upset rates using proton and heavy ions. The PROM was demonstrated to be immune to latch-up, as well as to static upset in the flash memory cells, to an LET > 125 MeV/mg/cmz (effective). The PROM was also tested in a dynamic mode, which revealed three distinct error modes: Read Bit Errors, Address Errors, and a Single Event Functional Interrupt (SEW which affected the data output drivers. Saturation cross-sections, and onset thresholds, for these errorinodes were measured at the heavy ion facility at Texas A&M University, and the proton facility at UC Davis. Additional testing was performed at UC Davis and the Cobalt 60 source at McClellan Air Force Base to examine the effect to TID life as a function of power biasing. The PROM demonstrated a 100% improvement in total TID life with an 84% percent decrease in device usage.

FPGA Virtex II SEU↗

Bristol Ridge: A 28-nm $\times$ 86 Performance-Enhanced Microprocessor Through System Power Management

Power management techniques can be effective at extracting more performance and energy efficiency out of mature systems on chip (SoCs). For instance, the peak performance of microprocessors is often limited by worst case technology (Vmax), infrastructure (thermal/electrical), and microprocessor usage assumptions. Performance/watt of microprocessors also typically suffers from guard bands associated with the test and binning processes as well as worst case aging/lifetime degradation. Similarly, on multicore processors, shared voltage rails tend to limit the peak performance achievable in low thread count workloads. In this paper, we describe five power management techniques that maximize the per-part performance under the before-mentioned constraints. Using these techniques, we demonstrate a net performance increase of up to 15% depending on the application and TDP of the SoC, implemented on 'Bristol Ridge,' a 28-nm CMOS, dual-core x 86 accelerated processing unit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diversity Strategies to Mitigate Postulated Common Cause Failure Vulnerabilities

This paper describes an approach to establish effective mitigating strategies that can resolve potential common-cause failure (CCF) vulnerabilities in instrumentation and control (I&C) systems at nuclear power plants. A particular objective in the development of these strategies, which consist of combinations of diversity attributes and their associated criteria, is to address the unique characteristics of digital technology that can contribute to CCF concerns. The research approach employed to establish diversity strategies involves investigation of available documentation on diversity usage and experience from nuclear power and non-nuclear industries, capture of expert knowledge and lessons learned, determination of common practices, and assessment of the nature of CCFs and compensating diversity attributes. The resulting diversity strategies address considerations such as the effect of technology choices, the nature of CCF vulnerabilities, and the prospective impact of each diversity type. In particular, the impact of each attribute and criterion on the purpose, process, product, and performance aspects of diverse systems are considered.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗