Search NASA⌕ Search

SEARCH · Search NASA

Results for “progress monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigation of INL Site Implementation of ARG-US

The Packaging Certification and Life Cycle Management department at Argonne National Laboratory (ANL) developed a suite of monitoring systems collectively referred to here as ARG-US. ARG-US is used to provide necessary data for nuclear facility and system operation and maintenance. ARG-US has been previously demonstrated in hot cells, radioactive material (RAM) storage areas, and RAM shipment trucks. It has also been installed directly on RAM storage and shipment containers. ARG-US offers some unique advantages over other commercially available systems by using wireless data connections, battery power supplies, and customizable monitoring methods. Idaho National Laboratory (INL) has been tasked with investigating applications for ARG-US at INL site facilities, which are operated by several different contractors. The initial investigation scope centered on CPP-603 Wet & Dry Fuel Storage Facility in relation to the upcoming DOE Spent (SNF) Packaging Demonstration. The investigation has been led by the Used Fuel Management Department in the Nuclear Science and Technology Directorate. This investigation is expected to recommend processes or facilities at the INL site at which to implement ARG-US systems. INL has engaged local site technical and oversite representatives, security, nuclear safeguards, and program management to identify good candidates for ARG-US test implementations. INL has identified high-level goals for any INL site implementation of ARG-US: provide unique testing environments, prompt development of new monitoring methods/techniques for the ARG-US suite, and acquire useful monitoring for the user facility. To these ends, INL suggests 3 program areas for further investigation: CPP-603 Fuel Handling Cave (FHC), legacy mixed waste storage systems at Idaho Nuclear Technology & Engineering Center (INTEC) known as the “tank farm”, and periodic and emergency environmental monitoring. This progress report relates activities undertaken in this investigation, describes the preliminary areas of interest for limited scope ARG-US testing or implementation, and relays expected actions needed to complete the task scope. This report offers an opportunity to the program sponsor, technical leads at ANL, and INL site representatives to give feedback on the initial assessment and make recommendations on the forthcoming activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Human-in-the-Loop: The Future of Machine Learning in Automated Electron Microscopy

Machine learning (ML) methods are progressively gaining acceptance in the electron microscopy community for de-noising, semantic segmentation, and dimensionality reduction of data post-acquisition. The introduction of the application programming interfaces (APIs) by major instrument manufacturers now allows the deployment of ML workflows in microscopes, not only for data analytics but also for real-time decision-making and feedback for microscope operation. However, the number of use cases for real-time ML remains remarkably small. Furthermore, we discuss some considerations in designing ML-based active experiments and pose that the likely strategy for the next several years will be human-in-the-loop automated experiments (hAE). In this paradigm, the ML learning agent directly controls beam position and image and spectroscopy acquisition functions, and a human operator monitors experiment progression in real and feature space of the system and tunes the policies of the ML agent to steer the experiment toward specific objectives.

47 OTHER INSTRUMENTATION↗

INL Site ARG-US Implementation – FY22 Activities and FY23 Plans

The Packaging Certification and Life Cycle Management program at Argonne National Laboratory (ANL) developed a suite of monitoring systems collectively referred to here as ARG-US. ARG-US provides necessary data for nuclear facility and system operation and maintenance, and has been previously demonstrated in hot cells, radioactive material (RAM) storage areas, and RAM shipment trucks. It has also been installed directly on RAM storage and shipment containers. ARG-US offers some unique advantages over other commercially available systems by using wireless data connections, battery power supplies, and customizable monitoring methods. Idaho National Laboratory (INL) has been tasked with investigating applications for ARG-US at INL site facilities, which are operated by several different contractors. The initial investigation scope centered on CPP-603 Irradiated Fuel Storage Facility in relation to the upcoming Department of Energy (DOE) Spent Nuclear Fuel (SNF) Packaging Demonstration. The investigation has been led by the Used Fuel Management Department in INL’s Nuclear Science and Technology (NS&T) directorate. This investigation is expected to recommend INL site processes or facilities in which to implement ARG-US systems. INL has engaged local site technical and oversight representatives, security, nuclear safeguards, and program management personnel to identify good candidates for ARG-US test implementations. INL has identified the following high-level goals for any INL site implementation of ARG-US: provide unique testing environments, prompt development of new monitoring methods/techniques for the ARG-US suite, and acquire useful monitoring for the user facility. As a result, INL suggests three program areas for further investigation: CPP-603 Fuel Handling Cave (FHC), legacy mixed waste storage systems at Idaho Nuclear Technology & Engineering Center (INTEC) known as the “Tank Farm,” and periodic and emergency environmental monitoring. This progress report relates activities undertaken in this investigation, describes the preliminary areas of interest for limited scope ARG-US testing or implementation, and relays expected actions for completing the task scope. This report offers an opportunity to the program sponsor, technical leads at ANL, and INL site representatives to give feedback on the initial assessment and make recommendations on the forthcoming activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online Monitoring System for Concrete Structures Affected by Alkali-Silica Reaction

This report presents a comprehensive study of developing ultrasonic wave and acoustic emission (AE) techniques for long-term monitoring of alkali-silica reaction (ASR) development in concrete. Small, medium, and full-scale concrete specimens were cast, conditioned, and monitored for various periods, from at least one year to 2.4 years. The reactive concrete specimens contain coarse or fine reactive aggregates to study the effects of different types of reactive aggregates. Confinements were also designed to simulate the 2-dimensional confinement effects of reinforcement in the shield building of nuclear power plants. The concrete specimens were stored in a environmental chamber with high humidity and high temperature to accelerate the ASR development. The ultrasonic monitoring data shows high sensitivity to ASR development and could detect cracking initiation well before visible surface cracks occurred. However, the linear ultrasonic analysis based on wave velocity is strongly affected by temperature variation. Therefore, a nonlinear ultrasonic method was proposed to measure thermally induced nonlinear acoustic responses of concrete (thermal modulation of ultrasonic wave). The measured nonlinear acoustic parameter shows a high correlation with ASR expansion across specimens with different reactive aggregates and confinement conditions. The same conclusion was obtained from nonlinear resonance tests on small concrete prisms. Compared to the linear acoustic methods, the nonlinear tests show high sensitivities to ASR damage from internal microcracking initiation at the early stage to visible cracks at the late stage of ASR. The attributes of the thermal modulation of nonlinear ultrasonic method include high sensitivity, immunity to temperature effects, and strong correlation with ASR expansion, which demonstrate great potentials of the nonlinear ultrasonic method for diagnosis of ASR damage and prediction of concrete deterioration process. Acoustic emission is a passive sensing technique for damage assessment, and access to only one surface is needed even for thick and heavily reinforced elements such as the walls utilized for nuclear shield building. Additionally, relatively few sensors are required to monitor the progression of the damage process. Results indicate that the AE data can be related to the damage rating index, which is a petrography-based means of assessing damage due to ASR in reinforced concrete. Furthermore, AE is capable of detecting ASR damage long before surface cracking is visually noticeable. Boundary conditions play in important role in the progression of ASR damage and differences in boundary conditions are reflected in the AE data. Entropy based data assessment methods provide a means to assess the damage state, and convolutional neural network based data assessment provided a means to assess the damage state in real-time. Results indicate that artificial neural network models may be used as a means to predict volumetric expansion based on AE data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Machine Learning for Ultrasonic Nondestructive Evaluation of Alkali–Silica Reaction in Concrete

Alkali–silica reaction (ASR) is a type of material degradation in concrete structures that leads to concrete cracking and rebar corrosion, thereby reducing the material’s structural integrity and the overall structure’s lifetime and raising safety concerns. Ultrasonic nondestructive evaluation (NDE) has been proven to be a valuable technique for assessing concrete properties and monitoring ASR progression in concrete. However, the deployment and analysis of ultrasonic NDE and its data requires specialized expertise, often relying on the engineer’s subjective interpretation. With the surge in computational power, artificial intelligence (AI) and machine learning (ML) algorithms have become popular in automating NDE data analysis. Various industrial sectors are increasingly adopting ML algorithms for NDE data analysis with a growing emphasis on AI–assisted automation. Regulatory agencies are also preparing for this technological shift, anticipating corresponding revisions in standards. Thus, there is an urgent need to identify the capabilities and limitations of current ML technologies for the evaluation of concrete material properties and damage status. Furthermore, the effects of various factors on ML model performance must be thoroughly investigated. The study summarized herein evaluated the effectiveness of two ML models (i.e., support vector regression (SVR) and deep neural network (DNN)) in predicting concrete material damage induced by ASR based on the long-term ultrasonic monitoring data. Four distinct concrete specimens were cast with artificially induced ASR, and over a period exceeding 500 days, ultrasonic signals and expansion data were continuously collected. For the SVR model, wave velocity and 12 other wave features were extracted from the ultrasonic signals, with 6 out of 13 features selected as input for the model. Different combinations of training and testing datasets were designed to explore factors influencing prediction performance, including the range of data within training and testing sets, in addition to various signal preprocessing methodologies. These findings suggest the importance of using a training dataset with a broader data range compared with testing datasets for improved model performance alongside consistent signal preprocessing across datasets.

36 MATERIALS SCIENCE↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗

Bio-reduction of ferrihydrite-montmorillonite-organic matter complexes: Effect of montmorillonite and fate of organic matter

Organic matter (OM) is often associated with Fe (hydr)oxides such as ferrihydrite (Fh) in soils and sediments, forming binary Fh-OM complexes. Microbial reduction of Fh results in destabilization of the complexes and mineral/OM transformation. However, little is known about the role of clay minerals in such processes, despite their common co-existence with Fh and OM in natural environments. Here Fh-OM complexes were synthesized in the presence of montmorillonite (SWy-2), forming ternary Fh-(SWy-2)-OM complexes. A metal-reducing bacterium Geobacter sulfurreducens was used to reduce Fh in the complexes under circumneutral pH and anoxic conditions with or without H 2 as extra electron donor. Various spectroscopy and mass spectrometry methods were used to monitor the progress of Fh bio-reduction and mineral/OM transformation. Results showed that G. sulfurreducens utilized mineral-bound OM as electron donor and/or carbon source to couple with Fh reduction. Relative to Fh-OM complex, Addition of SWy-2 to Fh-OM complex enhanced the bio-reduction extent of Fh by increasing the proportion of bioavailable OM that was weakly bound to SWy-2. However, its effect on the bio-reduction rate was variable. SWy-2 initially decreased the rate, because it spatially separated OM (electron donor) from Fh (electron acceptor). During later incubation, SWy-2 increased the reduction rate by sorbing biogenic Fe 2+ that would otherwise passivate the Fh and cell surfaces. Bio-reduction transformed mineral-bound OM to microbial products (e.g. necromass, extracellular polymeric substances), but organic compounds with aromatic structures, carboxyl groups and large molecular weight were more resistant to desorption and oxidation. The persistence of these compounds against bio-reduction induced transformation is likely due to their stronger binding with minerals and/or lower nominal oxidation states of carbon relative to other compounds. Our results provide new insights into the role of clay minerals in regulating biogeochemical cycling of solid-phase Fe and transformation of mineral-associated OM in anoxic soil environments.

58 GEOSCIENCES↗

Real Time 3D Observations of Portland Cement Carbonation at CO2 Storage Conditions

Depleted oil reservoirs are considered a viable solution to the global challenge of CO 2 storage. A key concern is whether the wells can be suitably sealed with cement to hinder the escape of CO 2 . Under reservoir conditions, CO 2 is in its supercritical state, and the high pressures and temperatures involved make real-time microscopic observations of cement degradation experimentally challenging. Here, we present an in situ 3D dynamic X-ray micro computed tomography (μ-CT) study of well cement carbonation at realistic reservoir stress, pore-pressure, and temperature conditions. The high-resolution time-lapse 3D images allow monitoring the progress of reaction fronts in Portland cement, including density changes, sample deformation, and mineral precipitation and dissolution. By switching between flow and nonflow conditions of CO 2 -saturated water through cement, we were able to delineate regimes dominated by calcium carbonate precipitation and dissolution. For the first time, we demonstrate experimentally the impact of the flow history on CO 2 leakage risk for cement plugging. In-situ μ-CT experiments combined with geochemical modeling provide unique insight into the interactions between CO 2 and cement, potentially helping in assessing the risks of CO 2 storage in geological reservoirs.

58 GEOSCIENCES↗

Interfacial Hydrophilicity Controls Mineral Transformation Outcomes for Enstatite and Amorphous MgSiO 3

Subsurface injection of carbon dioxide (CO 2 ) into mafic-ultramafic rocks for permanent storage via mineralization is being studied to reduce emissions. Here, we investigated the carbonation products of enstatite (MgSiO 3 ) to assess its efficiency in sequestering CO 2 for safe and permanent storage as carbonate minerals. This was accomplished by conducting variable temperature carbonation reactions with samples of differing crystallinities and surface chemistries. Reaction progress was monitored utilizing in situ X-ray diffraction, and the presence of carbonate products was confirmed using additional techniques, such as thermogravimetric analysis coupled with mass spectrometry and scanning electron microscopy with energy dispersive spectrometry. Our results show that crystalline enstatite produces small amounts of the anhydrous form of MgCO 3 (magnesite), while amorphous MgSiO 3 , which was used to simulate mafic glass, more readily converts to the hydrated/hydroxylated hydromagnesite [Mg 5 (CO 3 ) 4 (OH) 2 ·4H 2 O]. These results, supplemented with dynamic vapor sorption experiments, suggest that surface properties play a significant role in the pathway and degree of carbonation. These developments concerning the reactivity of CO 2 with reactive mafic phases will help further our understanding of the reactivity of these mafic-ultramafic minerals with implications for permanent carbon storage and other subsurface engineering scenarios involving reactive reservoirs.

basalt↗

Electrochemical Amyloid β Immunosensor Based on Ti 3 C 2 T x MXene Nanosheets

Alzheimer’s disease (AD) is the most common neurodegenerative disease and a major health-care problem. More than 55 million people in the world, including 6.7 million Americans, are living with AD. As AD is characterized by production and deposition of β-amyloid peptide (Aβ) in the brain, Aβ is considered as a potential biomarker for diagnosing and monitoring the progression of AD. Nanomaterials-based electrochemical immunosensor is one of the most promising methods for early diagnosis and therapeutic of AD, due to its highly selective, sensitive, and label-free advantages. The graphene-like two-dimensional (2D) MXene nanosheets have shown large surface area, good conductivity, biocompatibility, high ion transport, and low diffusion barrier, attracting attention in recent years to use it as the nanomaterial substrate for biosensor fabrication. In this paper, we presented a Ti 3 C 2 T x MXene nanosheets-based electrochemical immunosensor to detect trace Aβ for early diagnosis of AD.

59 BASIC BIOLOGICAL SCIENCES↗

Pre-Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre-symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

47 OTHER INSTRUMENTATION↗

Pre Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

59 BASIC BIOLOGICAL SCIENCES↗

Digital Engineering Sensor Architectures for Future Microreactor Builds

The development of new nuclear reactors continues to be high risk during the construction phase, with many programs exceeding their budget by 2–3×. This work entails an investigation of sensors that can be utilized during the construction of microreactors and their incorporation into a digital twin supporting the construction process. These sensors can be used to monitor construction progress, inform of variances from the expected design, and verify that the reactor is being built to the planned building information management model. This will ensure reactor equipment and components accurately interact through welding or additive manufacturing technologies. This study illustrates the importance of the digital engineering architecture for microreactor deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NuMI Beam Monitoring Simulation and Data Analysis Status and Progress

With the Main Injector Neutrino Oscillation Search (MINOS) experiment decommissioned, muon and hadron monitors became an important diagnostic tool for the NuMI O↵- axis vμ Appearance (NOvA) experiment at Fermilab to monitor the Neutrinos at the Main Injector (NuMI) beam. The goal of this study is to maintain the quality of the monitor signals and to establish correlations with the neutrino beam profile. And we carry out a systematic study of the response of the muon monitors to the changes in the parameters of the proton beam and lattice parameters. We report here on the progress of the beam data analysis and comparison with the simulation results.

43 PARTICLE ACCELERATORS↗

Progress on an Electron Beam Profile Monitor at the Fermilab Main Injector

The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam intensities in the Main Injector (MI) that will exceed 2 MW. Measuring the transverse profiles of these high intensity beams in a ring requires non-invasive techniques. The MI uses ionization profile monitors as its only profile system. An alternative technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. This type of device was installed in MI and initial studies of it have been previously presented. This paper will present the status and recent studies of the device utilizing different techniques.

43 PARTICLE ACCELERATORS↗

Progress on an Electron Beam Profile Monitor at the Fermilab Main Injector

The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam intensities in the Main Injector (MI) that will exceed 2 MW. Measuring the transverse profiles of these high intensity beams in a ring requires non-invasive techniques. The MI uses ionization profile monitors as its only profile system. An alternative technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. This type of device was installed in MI and initial studies of it have been previously presented. This paper will present the status and recent studies of the device utilizing different techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image-based time series analysis to establish differential disease progression for two Fusarium head blight pathogens in oat spikelets with variable resistance

Oat-based value-added products have increased their value as healthy foodstuff. Fusarium head blight (FHB) infections and the mycotoxins accumulated to the oat seeds, however, pose a challenge to oat production. The FHB infections are predicted to become more prevalent in the future changing climates and under more limited use of fungicides. Both these factors increase the pressure for breeding new resistant cultivars. Until now, however, genetic links in oats against FHB infection have been difficult to identify. Therefore, there is a great need for more effective breeding efforts, including improved phenotyping methods allowing time series analysis and the identification of molecular markers during disease progression. To these ends, dissected spikelets of several oat genotypes with different resistance profiles were studied by image-based methods during disease progression by Fusarium culmorum or F. langsethiae species. The chlorophyll fluorescence of each pixel in the spikelets was recorded after inoculation by the two Fusarium spp., and the progression of the infections was analyzed by calculating the mean maximum quantum yield of PSII (F v /F m ) values for each spikelet. The recorded values were (i) the change in the photosynthetically active area of the spikelet as percentage of its initial size, and (ii) the mean of F v /F m values of all fluorescent pixels per spikelet post inoculation, both indicative of the progression of the FHB disease. The disease progression was successfully monitored, and different stages of the infection could be defined along the time series. The data also confirmed the differential rate of disease progression by the two FHB causal agents. In addition, oat varieties with variable responses to the infections were indicated.

oats↗