Search NASA⌕ Search

SEARCH · Search NASA

Results for “proton exchange membrane electrolyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hydrogen production with seawater-resilient bipolar membrane electrolyzers

Generation of H 2 and O 2 from untreated water sources represents a promising alternative to ultrapure water required in contemporary proton exchange membrane-based electrolysis. Bipolar membrane-based devices, often used in electrodialysis and CO 2 electrolysis, facilitate impure water electrolysis via the simultaneous mediation of ion transport and enforcement of advantageous microenvironments. Herein, we report their application in direct seawater electrolysis; we show that upon introduction of ionic species such as Na + and Cl - from seawater, bipolar membrane electrolyzers limit the oxidation of Cl - to corrosive OCl - at the anode to a Faradaic efficiency (FE) of 0.005%, while proton exchange membrane electrolyzers under comparable operating conditions exhibit up to 10% FE to Cl oxidation. In conclusion, the effective mitigation of Cl - oxidation by bipolar membrane electrolyzers underpins their ability to enable longer-term seawater electrolysis than proton exchange membrane assemblies by a factor of 140, suggesting a path to durable seawater electrolysis.

08 HYDROGEN↗

Insights into the rapid two-phase transport dynamics in different structured porous transport layers of water electrolyzers through high-speed visualization

In proton exchange membrane electrolyzer cells (PEMECs), maintaining efficient two-phase transport is one of the most important functions of porous transport layers (PTLs). To enhance the two-phase transport in PTLs, thin/titanium liquid/gas diffusion layers (TT-LGDLs) are introduced in PEMECs, and their difference from the conventional Ti felt PTLs are analyzed in-situ through high-speed and microscale visualization and electrochemical characterizations. The visualization results show that unfavorable large slugs can be greatly reduced in the PEMEC with a TT-LGDL compared to the PEMEC with a Ti felt PTL. More importantly, the recovery capability of water starvation with different PTLs is studied. After water starvation, the PEMEC with the TT-LGDL can recover the water starvation much more rapidly than the Ti felt cell, benefiting from its short and straight-through flow paths. Furthermore, the TT-LGDL tends to generate oxygen bubbles that are almost six times smaller and 236 times more frequently than the Ti felt PTL, indicating significantly boosted removal efficiency of produced oxygen and PEMEC performance. Finally, this study offers new insights into the dynamic processes of two-phase transport and the recovery capability of water starvation for different PTLs, which will provide valuable guidance for further optimization of PTLs and performance enhancement of PEMECs.

08 HYDROGEN↗

High-speed characterization of two-phase flow and bubble dynamics in titanium felt porous media for hydrogen production

Bubble dynamics and two-phase flow phenomena are closely related to the performance of proton exchange membrane electrolyzer cells (PEMECs). This paper reports an in-situ study of the oxygen bubble behavior and associated multiphase evolutions in the anode side of PEMECs with titanium (Ti) felt liquid gas diffusion layers (LGDLs) by a high-speed visualization system. The micro oxygen bubble dynamics was captured and analyzed at different locations and virous operating conditions. The results show that the bubble detachment frequency and detachment diameter greatly increase with the operating current density. Additionally, they are significantly impacted by the local pore structure and morphology of Ti felt LGDLs. In the flow channels, there exist only several discrete micro bubbles at a low current density (0.04 A/cm 2 ) and a large flow velocity (133 mm/s). At a current density (0.2 A/cm 2 ) and a flow velocity (67 mm/s), a number of gas slugs are formed in the follow channels, in addition to discrete micro bubbles. At a high current density (1 A/cm 2 ) and a flow velocity (67 mm/s), more bubbles appear in the channel, and the flow field is dominated by slug or annular flows. These investigations can help to better understand the two-phase flow and bubble detachment mechanism, and provide a foundation for electrochemical reaction, multiphase flow studies and optimize the design of gas diffusion layers and flow fields for PEMECs in the future.

08 HYDROGEN↗

Tuning Catalyst Activation and Utilization Via Controlled Electrode Patterning for Low-Loading and High-Efficiency Water Electrolyzers

An anode electrode concept of thin catalyst-coated liquid/gas diffusion layers (CCLGDLs), by integrating Ir catalysts with Ti thin tunable LGDLs with facile electroplating in proton exchange membrane electrolyzer cells (PEMECs), is proposed. The CCLGDL design with only 0.08 mg Ir cm -2 can achieve comparative cell performances to the conventional commercial electrode design, saving ~97% Ir catalyst and augmenting a catalyst utilization to ~24 times. CCLGDLs with regulated patterns enable insight into how pattern morphology impacts reaction kinetics and catalyst utilization in PEMECs. A specially designed two-sided transparent reaction-visible cell assists the in situ visualization of the PEM/electrode reaction interface for the first time. Oxygen gas is observed accumulating at the reaction interface, limiting the active area and increasing the cell impedances. In this work, it is demonstrated that mass transport in PEMECs can be modified by tuning CCLGDL patterns, thus improving the catalyst activation and utilization. The CCLGDL concept promises a future electrode design strategy with a simplified fabrication process and enhanced catalyst utilization. Furthermore, the CCLGDL concept also shows great potential in being a powerful tool for in situ reaction interface research in PEMECs and other energy conversion devices with solid polymer electrolytes.

08 HYDROGEN↗

Ionomer-free nanoporous iridium nanosheet electrodes with boosted performance and catalyst utilization for high-efficiency water electrolyzers

Increasing the catalyst utilization efficiency and simplifying electrode fabrication processes are crucial to accelerate development of low-cost proton exchange membrane electrolyzer cells (PEMECs). Here, we develop a facile route to fabricate ionomer-free iridium nanosheet integrated electrodes, in which nanoporous iridium nanosheets (IrNS) with abundant exposed edges and nanopores are deposited on thin titanium liquid/gas diffusion layers (TT-LGDLs) via a low-temperature chemical synthesis strategy. Further, benefiting from high catalytic activity, good electrode conductivity and excellent liquid/gas transport properties, such nanoporous IrNS electrodes with low catalyst loadings require low cell voltages of 1.65 V and 1.78 V at 3000 and 6000 mA/cm 2 , respectively. More impressively, a stable performance can be well maintained under extremely high current density tests of 5000 mA/cm 2 , demonstrating the potential of low-loading nanoporous IrNS electrodes in solid-electrolyte based electrochemical conversion cells that require high current density operation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyzer Performance Loss from Accelerated Stress Tests and Corresponding Changes to Catalyst Layers and Interfaces

Stress tests are developed for proton exchange membrane electrolyzers that utilize low catalyst loading, elevated potential, and frequent cycling with square- and triangle-waves to accelerate anode catalyst layer degradation during intermittent operation. Kinetics drive performance losses (ohmic/transport secondary) and are accompanied by decreasing exchange current density, decreasing cyclic voltammetric capacitance, and increasing polarization resistance. Decreased kinetics are likely due to a combination of iridium (Ir) migration into electrochemically inaccessible locations in the anode or membrane, Ir particle growth (supported by X-ray scattering), changes in the extent of the Ir oxidation state (supported by X-ray absorption spectroscopy), and anode catalyst layer reordering. Decreasing catalyst/transport layer contact and catalyst/membrane interfacial tearing may add contact resistances and account for increasing ohmic losses. Performance losses for low and moderate catalyst loading, as well as from accelerated and model wind/solar cycling protocols, were likewise dominated by kinetics but vary in severity. Additionally, accelerated cycling (1 cycle per minute) appears to reasonably accelerate relevant loss mechanisms and can be used to project electrolyzer lifetime from anode deterioration. Ongoing accelerated stress test development and studies into performance loss mechanisms will continue to be critical as electrolysis shifts to intermittent power and low-cost applications.

30 DIRECT ENERGY CONVERSION↗

Interfacial engineering via laser ablation for high-performing PEM water electrolysis

A rationalized interfacial design strategy was applied to tailor the porous transport layer (PTL)-catalyst layer (CL) contact and the PTL bulk-phase architecture. Particularly, at the PTL-CL interface, our results reveal that laser ablated sintered titanium power-based PTLs improve electrolyzer performance at both the H2NEW Consortium baseline catalyst loading of 0.4 mgIr cm -2 as well as at the ultra-low catalyst loading of 0.055 mgIr cm -2 . Under ultra-low catalyst loadings, the laser ablated PTL demonstrates maximum reduction of 230 mV compared to the commercial PTL at 4 A cm -2 , and reduces by 68 mV at 3.2 A cm -2 under H2NEW baseline loading. Laser ablation alters the titanium phase at the interface, so it forms more uniform structure like a microporous layer or a backing layer, leading to an increase in the surface area in contact with the catalyst layer while preventing the membrane from deforming into the PTL. Moreover, we reveal that bulk-phase architecture modification of the PTL by ablating patterned pores at the flow field-PTL interface improves mass transport without sacrificing contact at the CL-PTL interface. Overall, laser ablation of the PTL is an effective method to customize interfacial design to enhance proton exchange membrane electrolyzer performance.

08 HYDROGEN↗

Ultrathin platinum nanowire based electrodes for high-efficiency hydrogen generation in practical electrolyzer cells

Significant reduction of noble metal catalyst loading and simplification of electrode fabrication are urgently needed in order to lower the cost of proton exchange membrane electrolyzer cells (PEMECs) for large-scale hydrogen production. Herein, we report an integrated electrode design comprising in-situ grown platinum nanowires (PtNW) on ultrathin titanium liquid/gas diffusion layers (LGDLs) via a cost-effective and green chemical synthesis approach. The ultrathin integrated PtNW electrodes showed a low cell voltage of 1.643 V and high efficiency of 90.08% at 1000 mA cm -2 using about 15 times lower catalyst loadings than a conventional catalyst-coated membrane in PEMEC tests. Ex-situ electrochemical characterizations and microscale visualizations further reveal that PtNW electrodes display highly efficient hydrogen evolution reactions and excellent electrode durability due to high active surface area, favorable bubble detachment, and structural stability. This work provides new insights into catalyst layer design and facile ultrathin electrode fabrication for more compact and low-cost PEM electrolyzers, fuel cells and other systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A techno-economic evaluation of solar-powered green hydrogen production for sustainable energy consumption in Belgium

Here this study focuses on the production and consumption of solar-powered green hydrogen in Belgium by comparing the costs of domestic production with those of imports from Morocco and Namibia. The levelized cost of hydrogen (LCOH) is determined via a techno-economic assessment considering various parameters including, power connectivity, electrolyzer types, location factors, and risk premium. The results show that the lowest LCOH can be achieved by on-grid Proton exchange membrane electrolyzers (PEMEL). LCOH of production in Belgium, Morocco, and Namibia with a PEMEL on-grid system are 5.64, 6.32 and 5.13 euro/kg H 2 , respectively. Thus, importing hydrogen from Namibia to Belgium is more competitive than domestic production. The sensitivity analysis suggests that a target LCOH of 3 euro/kg H 2 is achievable by importing from Namibia through various cost combinations. One of these combinations involves reducing the cost of PV panels to 222.3 euro/kW (70% reduction) and electrolyzers to 363.3 euro/kW (25% reduction).

08 HYDROGEN↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen SPE fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. The SPE cells have demonstrated a ten year life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton-exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluroride loss rates and average expected ultimate cell life. Several features were introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability were demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density. The SPE electrolyzers have demonstrated the same at 1000 ASF. Many future extraterrestrial applications for fuel cells require that they be self recharged. To translate the proven SPE cell life and stability into a highly reliable extraterrestrial electrical energy storage system, a simplification of supporting equipment is required. Static phase separation, static fluid transport and static thermal control will be most useful in producting required system reliability. Although some 200,000 SPE fuel cell hours were recorded in earth orbit with static fluid phase separation, no SPE electrolyzer has, as yet, operated in space.

Baldwin, R.↗

Grid ancillary services using electrolyzer-Based power-to-Gas systems with increasing renewable penetration

Increasing penetrations of renewable-based generation have led to a decrease in the bulk power system inertia and an increase in intermittency and uncertainty in generation. Energy storage is considered to be an important factor to help manage renewable energy generation at greater penetrations. Hydrogen is a viable long-term storage alternative. This paper analyzes and presents use cases for leveraging electrolyzer-based power-to-gas systems for electric grid support. The paper also discusses some grid services that may favor the use of hydrogen-based storage over other forms such as battery energy storage. Real-time controls are developed, implemented and demonstrated using a power-hardware-in-the-loop(PHIL) setup with a 225-kW proton-exchange-membrane electrolyzer stack. These controls demonstrate frequency and voltage support for the grid for different levels of renewable penetration (0%, 25%, and 50%). A comparison of the results shows the changes in respective frequencies and voltages as seen as different buses as a result of support from the electrolyzers and notes the impact on hydrogen production as a result of grid support. Finally, the paper discusses the practical nuances of implementing the tests with physical hardware, such as inverter/electrolyzer efficiency, as well as the related constraints and opportunities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrolyzer and Fuel Cell Recycling for a Circular Hydrogen Economy

Abstract Electrolyzers and fuel cells will be crucial for achieving global clean hydrogen and industrial decarbonization goals. However, the nascent clean hydrogen sector faces uncertainties around material supply chains and technology end‐of‐life management. This work aims to guide the transition to a circular hydrogen economy by using process modeling, techno‐economic analysis, and life cycle assessment to evaluate the material cost, energy use, greenhouse gas (GHG) emissions, toxicity, and water use of five potential recycling strategies for proton exchange membrane electrolyzers (PEMWE) and fuel cells (PEMFC). Hydrometallurgy, acid dissolution, and electrochemical dissolution are shown to offer 2–7 times improvement across all assessed metrics relative to the manufacturing of PEMWE and PEMFC from raw materials. Recycling can also lower the raw material demand, material cost, energy use, and GHG emissions associated with PEMWE and PEMFC deployment in the United States in 2050 by 23%, 19%, 21%, and 16%, respectively. This study provides key insights into the costs, benefits, and complexities of recycling strategies for PEMWE and PEMFC, aiding the development of a circular economy that is synergistic with clean hydrogen deployment.

08 HYDROGEN↗

Discovering Reactant Supply Pathways at Electrode/PEM Reaction Interfaces Via a Tailored Interface-Visible Characterization Cell

In situ and micro-scale visualization of electrochemical reactions and multiphase transports on the interface of porous transport electrode (PTE) materials and solid polymer electrolyte (SPE) has been one of the greatest challenges for electrochemical energy conversion devices, such as proton exchange membrane electrolyzer cells (PEMECs), CO 2 reduction electrolyzers, PEM fuel cells, etc. Here, an interface-visible characterization cell (IV-CC) is developed to in situ visualize micro-scaled and rapid electrochemical reactions and transports in PTE/SPE interfaces. Taking the PEMEC of a green hydrogen generator as a study case, the unanticipated local gas blockage, micro water droplets, and their evolution processes are successfully visualized on PTE/PEM interfaces in a practical PEMEC device, indicating the existence of unconventional reactant supply pathways in PEMs. Further comprehensive results reveal that PEM water supplies to reaction interfaces are significantly impacted with current densities. Here these results provide critical insights about the reaction interface optimization and mass transport enhancement in various electrochemical energy conversion devices.

30 DIRECT ENERGY CONVERSION↗

Electrochemically Grown Ultrathin Platinum Nanosheet Electrodes with Ultralow Loadings for Energy-Saving and Industrial-Level Hydrogen Evolution

Nanostructured catalyst-integrated electrodes with remarkably reduced catalyst loadings, high catalyst utilization and facile fabrication are urgently needed to enable cost-effective, green hydrogen production via proton exchange membrane electrolyzer cells (PEMECs). Herein, benefitting from a thin seeding layer, bottom-up grown ultrathin Pt nanosheets (Pt-NSs) were first deposited on thin Ti substrates for PEMECs via a fast, template- and surfactant-free electrochemical growth process at room temperature, showing highly uniform Pt surface coverage with ultralow loadings and vertically well-aligned nanosheet morphologies. Combined with an anode-only Nafion 117 catalyst-coated membrane (CCM), the Pt-NS electrode with an ultralow loading of 0.015 mg Pt cm -2 demonstrates superior cell performance to the commercial CCM (3.0 mg Pt cm -2 ), achieving 99.5% catalyst savings and more than 237-fold higher catalyst utilization. The remarkable performance with high catalyst utilization is mainly due to the vertically well-aligned ultrathin nanosheets with good surface coverage exposing abundant active sites for the electrochemical reaction. Overall, this study not only paves a new way for optimizing the catalyst uniformity and surface coverage with ultralow loadings but also provides new insights into nanostructured electrode design and facile fabrication for highly efficient and low-cost PEMECs and other energy storage/conversion devices.

42 ENGINEERING↗

Amorphous Iridium Oxide-Integrated Anode Electrodes with Ultrahigh Material Utilization for Hydrogen Production at Industrial Current Densities

Herein, ionomer-free amorphous iridium oxide (IrO x ) thin electrodes are first developed as highly active anodes for proton exchange membrane electrolyzer cells (PEMECs) via low-cost, environmentally friendly, and easily scalable electrodeposition at room temperature. Combined with a Nafion 117 membrane, the IrO x -integrated electrode with an ultralow loading of 0.075 mg cm –2 delivers a high cell efficiency of about 90%, achieving more than 96% catalyst savings and 42-fold higher catalyst utilization compared to commercial catalyst-coated membrane (2 mg cm –2 ). Additionally, the IrO x electrode demonstrates superior performance, higher catalyst utilization and significantly simplified fabrication with easy scalability compared with the most previously reported anodes. Notably, the remarkable performance could be mainly due to the amorphous phase property, sufficient Ir 3+ content, and rich surface hydroxide groups in catalysts. Overall, due to the high activity, high cell efficiency, an economical, greatly simplified and easily scalable fabrication process, and ultrahigh material utilization, the IrO x electrode shows great potential to be applied in industry and accelerates the commercialization of PEMECs and renewable energy evolution.

08 HYDROGEN↗

Morphology engineering of iridium electrodes via modifying titanium substrates with controllable pillar structures for highly efficient oxygen evolution reaction

Nowadays, Ti is the well-chosen anode substrate material for proton exchange membrane electrolyzer cells (PEMECs) and modifications of the substrate surfaces are essential for the fabrication of highly efficient electrodes. Herein, we introduce the morphology engineering of Ir/Ti electrodes with different acid treatments of hydrochloric acid (HCl) and oxalic acid (OA), and the comparative benefits of these two acid treatment methods are studied from the aspects of their impacts on the morphology, interfacial contact resistance (ICR), and oxygen evolution reaction (OER) performances of resultant electrodes. Notably, compared to the flat surface from OA treatment, Ti substrates with the pillar structure could be successfully achieved via HCl etching. Further, the HCl and the oxalic acid (OA) treatments would reduce the interfacial contact resistance (ICR) to 15.2% and 5.5% of the pristine Ti substrate at 1.38 MPa, respectively. By iridium electrodeposition on Ti substrates, Ir/Ti electrodes with different catalyst loadings are fabricated. With similar low-loadings of about 0.05 mgIr cm –2 , an Ir/Ti electrode with HCl treated substrate exhibits a lower overpotential of ~283 mV at 10 mA cm –2 current density than 305 mV from OA treatment, due to the boosted reaction areas from HCl treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modifying redox properties and local bonding of Co 3 O 4 by CeO 2 enhances oxygen evolution catalysis in acid

Developing efficient and stable earth-abundant electrocatalysts for acidic oxygen evolution reaction is the bottleneck for water splitting using proton exchange membrane electrolyzers. Here, we show that nanocrystalline CeO 2 in a Co 3 O 4 /CeO 2 nanocomposite can modify the redox properties of Co 3 O 4 and enhances its intrinsic oxygen evolution reaction activity, and combine electrochemical and structural characterizations including kinetic isotope effect, pH- and temperature-dependence, in situ Raman and ex situ X-ray absorption spectroscopy analyses to understand the origin. The local bonding environment of Co 3 O 4 can be modified after the introduction of nanocrystalline CeO 2 , which allows the CoIII species to be easily oxidized into catalytically active CoIV species, bypassing the potential-determining surface reconstruction process. Co 3 O 4 /CeO 2 displays a comparable stability to Co 3 O 4 thus breaks the activity/stability tradeoff. This work not only establishes an efficient earth-abundant catalysts for acidic oxygen evolution reaction, but also provides strategies for designing more active catalysts for other reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen and Battery Storage Technologies for Low-Cost Energy Decarbonization in Distribution Networks

Deep energy decarbonization cannot be achieved without high penetration of renewables. At higher renewable energy penetrations, the variability and intermittent nature of solar photovoltaic (PV) electricity can cause ramping issues with existing fossil fuel generation, requiring longer term energy storage to increase the reliability of grid operation. Here, a proton exchange membrane electrolyzer can produce H 2 and serves as a utility controllable load. The produced H 2 can then be stored and converted back into electricity, or mixed with natural gas, or used as transportation fuel, or chemical feedstock. This paper considers the perspective of the distribution system operator that operates the distributed energy resources on a standard IEEE 33-node distribution network considering the technical and physical constraints with the goal of minimizing total investment and operation cost. Different case studies, at very high PV penetrations are considered to show the challenges and path to net-zero emission energy production using H 2 energy. Sensitivity of utility PV costs and electrolyzer capital costs on producing H 2 at $\$1$ /kg are presented showing that the distribution network could produce 100% renewable electricity and H 2 could be produced at a cost of $\$1$ /kg by 2050 with conservative cost estimates and by 2030 with accelerated cost declines.

25 ENERGY STORAGE↗