Search NASA⌕ Search

SEARCH · Search NASA

Results for “proximal algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A proximal trust-region method for nonsmooth optimization with inexact function and gradient evaluations

Many applications require minimizing the sum of smooth and nonsmooth functions. For example, basis pursuit denoising problems in data science require minimizing a measure of data misfit plus an $\ell^1$-regularizer. Similar problems arise in the optimal control of partial differential equations (PDEs) when sparsity of the control is desired. Here, we develop a novel trust-region method to minimize the sum of a smooth nonconvex function and a nonsmooth convex function. Our method is unique in that it permits and systematically controls the use of inexact objective function and derivative evaluations. When using a quadratic Taylor model for the trust-region subproblem, our algorithm is an inexact, matrix-free proximal Newton-type method that permits indefinite Hessians. We prove global convergence of our method in Hilbert space and demonstrate its efficacy on three examples from data science and PDE-constrained optimization.

97 MATHEMATICS AND COMPUTING↗

Online Optimization as a Feedback Controller: Stability and Tracking

This paper develops and analyzes feedback-based online optimization methods to regulate the output of a linear time-invariant (LTI) dynamical system to the optimal solution of a time-varying convex optimization problem. The design of the algorithm is based on continuous-time primal-dual dynamics, properly modified to incorporate feedback from the LTI dynamical system, applied to a proximal augmented Lagrangian function. The resultant closed-loop algorithm tracks the solution of the time-varying optimization problem without requiring knowledge of (time-varying) disturbances in the dynamical system. The analysis leverages integral quadratic constraints to provide linear matrix inequality (LMI) conditions that guarantee global exponential stability and bounded tracking error. Analytical results show that, under a sufficient time-scale separation between the dynamics of the LTI dynamical system and the algorithm, the LMI conditions can be always satisfied. The paper further proposes a modified algorithm that can track an approximate solution trajectory of the constrained optimization problem under less restrictive assumptions. As an illustrative example, the proposed algorithms are showcased for power transmission systems, to compress the time scales between secondary and tertiary control, and allow to simultaneously power re-balancing and tracking of DC optimal power flow points.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MO-A-BRD-09: A Data-Mining Algorithm for Large Scale Analysis of Dose-Outcome Relationships in a Database of Irradiated Head-And-Neck (HN) Cancer Patients

Purpose: To develop a framework for automatic extraction of clinically meaningful dosimetric-outcome relationships from an in-house, analytic oncology database. Methods: Dose-volume histograms (DVH) and clinical outcome-related structured data elements have been routinely stored to our database for 513 HN cancer patients treated from 2007 to 2014. SQL queries were developed to extract outcomes that had been assessed for at least 100 patients, as well as DVH curves for organs-at-risk (OAR) that were contoured for at least 100 patients. DVH curves for paired OAR (e.g., left and right parotids) were automatically combined and included as additional structures for analysis. For each OAR-outcome combination, DVH dose points, D(V{sub t}), at a series of normalized volume thresholds, V{sub t}=[0.01,0.99], were stratified into two groups based on outcomes after treatment completion. The probability, P[D(V{sub t})], of an outcome was modeled at each V{sub t} by logistic regression. Notable combinations, defined as having P[D(V{sub t})] increase by at least 5% per Gy (p<0.05), were further evaluated for clinical relevance using a custom graphical interface. Results: A total of 57 individual and combined structures and 115 outcomes were queried, resulting in over 6,500 combinations for analysis. Of these, 528 combinations met the 5%/Gy requirement, with further manual inspection revealing a number of reasonable models based on either reported literature or proximity between neighboring OAR. The data mining algorithm confirmed the following well-known toxicity/outcome relationships: dysphagia/larynx, voice changes/larynx, esophagitis/esophagus, xerostomia/combined parotids, and mucositis/oral mucosa. Other notable relationships included dysphagia/pharyngeal constrictors, nausea/brainstem, nausea/spinal cord, weight-loss/mandible, and weight-loss/combined parotids. Conclusion: Our database platform has enabled large-scale analysis of dose-outcome relationships. The current data-mining framework revealed both known and novel dosimetric and clinical relationships, underscoring the potential utility of this analytic approach. Multivariate models may be necessary to further evaluate the complex relationship between neighboring OARs and observed outcomes. This research was supported through collaborations with Elekta, Philips, and Toshiba.

60 APPLIED LIFE SCIENCES↗

SU-E-T-317: Dosimetric Evaluation of Acuros XB Advanced Dose Calculation Algorithm in Head and Neck Patients

Purpose: The Acuros XB photon dose calculation algorithm is a newly implemented calculation technique within the Eclipse treatment planning system using deterministic solutions to the linear Boltzmann transport equations. The goal of this study is to assess the clinical impact of dose differences arising from a retrospective comparison of calculations performed using the Analytical Anisotropic Algorithm (AAA) and Acuros XB on patients. Methods: Ten head and neck patients receiving intensity modulated radiation therapy were selected as a pilot study. Initial evaluation was based on the percentage of the planning target volume (PTV) covered by the prescription dose, minimum dose within the PTV, and dose differences in critical structures. For patients receiving boost plans, dosimetric evaluations were performed on the plan sum of the primary and boost plans. Results: Among the ten patients there were a total of 21 PTVs corresponding to primary and boost volumes. Using the same normalization within Eclipse, the average percentage of the PTVs receiving the prescription dose were 95.6% for AAA and Acuros XB. The average minimum doses within the PTVs, expressed as a percentage of the prescription to the volume, were 82.3% and 83.6% for AAA and Acuros XB respectively. Neither comparison showed differences with statistical significance when subjected to a paired t-test. Statistical significance was found in the average difference of the maximum dose for the mandible (242.5cGy, p=0.0005) and cord with a 5mm radial expansion (105.0cGy, p=0.0005) and in the median dose for the left parotid (25.0cGy, p=0.0423) and oral cavity (36.3cGy, p=0.002). Conclusion: The Acuros XB dose calculation algorithm did not exhibit significant differences in PTV coverage when compared to the AAA algorithm. Significant differences in critical structures are likely attributed to the structures proximity to high atomic number materials or air cavities, regions of known difficulty for the AAA algorithm.

60 APPLIED LIFE SCIENCES↗

Boosting the Performance of Plug-and-Play Priors via Denoiser Scaling

Plug-and-play priors (PnP) is an image reconstruction framework that utilizes an image denoiser as an imaging prior. Unlike traditional regularized inversion, PnP does not require the prior to be expressible in the form of a regularization function. This flexibility enables PnP algorithms to exploit the most effective image denoisers, leading to their state-of-the-art performance in various imaging tasks. However, many powerful denoisers, such as the ones based on convolutional neural networks (CNNs), do not have tunable parameters that would allow controlling their influence within PnP. To address this issue, in this paper, we introduce a scaling parameter that adjusts the magnitude of the denoiser input and output. We theoretical justify the denoiser scaling from the perspectives of proximal optimization, statistical estimation, and consensus equilibrium. Finally, we provide numerical experiments demonstrating the ability of denoiser scaling to systematically improve the performance of PnP for denoising CNN priors that do not have explicitly tunable parameters.

Boosting↗

Online State Estimation for Time-Varying Systems

The paper investigates the problem of estimating the state of a time-varying system with a linear measurement model; in particular, the paper considers the case where the number of measurements available can be smaller than the number of states. In lieu of a batch linear least-squares (LS) approach well-suited for static networks, where a sufficient number of measurements could be collected to obtain a full-rank design matrix the paper proposes an online algorithm to estimate the possibly time-varying state by processing measurements as and when available. The design of the algorithm hinges on a generalized LS cost augmented with a proximal-point-type regularization. With the solution of the regularized LS problem available in closed-form, the online algorithm is written as a linear dynamical system where the state is updated based on the previous estimate and based on the new available measurements. Conditions under which the algorithmic steps are in fact a contractive mapping are shown, and bounds on the estimation error are derived for different noise models. Numerical simulations are provided to corroborate the analytical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantitative modeling of ICRF antennas with integrated time domain RF sheath and plasma physics

Significant efforts have been made to quantitatively benchmark the sheath sub-grid model used in our time-domain simulations of plasma-immersed antenna near fields, which includes highly detailed three-dimensional geometry, the presence of the slow wave, and the non-linear evolution of the sheath potential. We present both our quantitative benchmarking strategy, and results for the ITER antenna configuration, including detailed maps of electric field, and sheath potential along the entire antenna structure. Our method is based upon a time-domain linear plasma model, using the finite-difference electromagnetic Vorpal/Vsim software. This model has been augmented with a non-linear rf-sheath sub-grid model, which provides a self-consistent boundary condition for plasma current where it exists in proximity to metallic surfaces. Very early, this algorithm was designed and demonstrated to work on very complicated three-dimensional geometry, derived from CAD or other complex description of actual hardware, including ITER antennas. Initial work with the simulation model has also provided a confirmation of the existence of propagating slow waves in the low density edge region, which can significantly impact the strength of the rf-sheath potential, which is thought to contribute to impurity generation. Our sheath algorithm is based upon per-point lumped-circuit parameters for which we have estimates and general understanding, but which allow for some tuning and fitting. We are now engaged in a careful benchmarking of the algorithm against known analytic models and existing computational techniques to insure that the predictions of rf-sheath voltage are quantitatively consistent and believable, especially where slow waves share in the field with the fast wave. Currently in progress, an addition to the plasma force response accounting for the sheath potential, should enable the modeling of sheath plasma waves, a predicted additional root to the dispersion, existing at the plasma-metal interface. Our model is presently restricted to plasma in the vicinity of metallic (highly conducting) surfaces, however we report on a new effort to include thin and thick dielectric (poorly conducting) surfaces, which are of interest to both fusion devices and to industrial plasmas, where dielectric, or dielectric-coated vessels and geometry are heavily used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward active disruption avoidance via real-time estimation of the safe operating region and disruption proximity in tokamaks

This paper describes a real-time capable algorithm for identifying the safe operating region around a tokamak operating point. The region is defined by a convex set of linear constraints, from which the distance of a point from a disruptive boundary can be calculated. The disruptivity of points is calculated from an empirical machine learning predictor that generates the likelihood of disruption. While the likelihood generated by such empirical models can be compared to a threshold to trigger a disruption mitigation system, the safe operating region calculation enables active optimization of the operating point to maintain a safe margin from disruptive boundaries. The proposed algorithm is tested using a random forest disruption predictor fit on data from DIII-D. The safe operating region identification algorithm is applied to historical data from DIII-D showing the evolution of disruptive boundaries and the potential impact of optimization of the operating point. Real-time relevant execution times are made possible by parallelizing many of the calculation steps and implementing the algorithm on a graphics processing unit. Lastly, a real-time capable algorithm for optimizing the target operating point within the identified constraints is also proposed and simulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data on Cu- and Ni-Si-Mn-rich solute clustering in a neutron irradiated austenitic stainless steel

The data presented in this article is supplementary to the research article “Phase instabilities in austenitic steels during particle bombardment at high and low dose rates” (Levine et al.). Needle-shaped samples were prepared with focused ion beam milling from a 304L stainless steel that was irradiated with fast neutrons (E 0.1 MeV) in the BOR-60 reactor at 318 °C to 47.5 dpa. Atom probe tomography (APT) experiments in voltage mode were then conducted on a Cameca LEAP 5000X HR. Atom position, range, and mass spectrum files after reconstruction with Cameca’s IVAS software are included. Cu- and Ni-Si-Mn-rich solute nanoclusters were identified and analyzed using the Open Source Characterization of APT Reconstructions (OSCAR) program. Python code for OSCAR, information on the program’s underlying algorithm, and sample output files are provided. A proximity histogram of a Ni-Si-Mn-rich cluster and a 1D density/solute concentration profile of a Cu-rich cluster are given to demonstrate OSCAR’s analytical functionalities. The provided APT dataset is valuable for benchmarking phase instabilities in neutron-irradiated austenitic stainless steels that occur at high doses. The OSCAR program can be reused to process other APT data sets where solute nanoclustering is of interest.

42 ENGINEERING↗

Rational Design of Orthogonal Multipolar Interactions with Fluorine in Protein–Ligand Complexes

Multipolar interactions involving fluorine and the protein backbone have been frequently observed in protein–ligand complexes. Such fluorine–backbone interactions may substantially contribute to the high affinity of small molecule inhibitors. Here we found that introduction of trifluoromethyl groups into two different sites in the thienopyrimidine class of menin–MLL inhibitors considerably improved their inhibitory activity. In both cases, trifluoromethyl groups are engaged in short interactions with the backbone of menin. In order to understand the effect of fluorine, we synthesized a series of analogues by systematically changing the number of fluorine atoms, and we determined high-resolution crystal structures of the complexes with menin. Here, we found that introduction of fluorine at favorable geometry for interactions with backbone carbonyls may improve the activity of menin–MLL inhibitors as much as 5- to 10-fold. In order to facilitate the design of multipolar fluorine–backbone interactions in protein–ligand complexes, we developed a computational algorithm named FMAP, which calculates fluorophilic sites in proximity to the protein backbone. We demonstrated that FMAP could be used to rationalize improvement in the activity of known protein inhibitors upon introduction of fluorine. Furthermore, FMAP may also represent a valuable tool for designing new fluorine substitutions and support ligand optimization in drug discovery projects. Analysis of the menin–MLL inhibitor complexes revealed that the backbone in secondary structures is particularly accessible to the interactions with fluorine. Lastly, considering that secondary structure elements are frequently exposed at protein interfaces, we postulate that multipolar fluorine–backbone interactions may represent a particularly attractive approach to improve inhibitors of protein–protein interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phosphorus doping of Si nanocrystals embedded in silicon oxynitride determined by atom probe tomography

Silicon nanocrystals (SiNCs) embedded in a silicon oxide matrix were studied by 3D atom probe tomography (APT). The distribution of the SiNC diameter was found to have a mean value of 3.7 ± 0.8 nm. The elemental composition of these particles was determined by employing two different approaches: (i) The proximity histogram method and (ii) a cluster identification algorithm based on maximum-atom separations. Both approaches give very similar values in terms of the amount of P, O, and Si within the SiNCs: the mean atomic concentrations are c{sub P} = 0.77% ± 0.4%, c{sub O} = 12.3% ± 2.1%, and c{sub Si} = 85.3% ± 2.1%. A detailed cluster analysis implies that, on average, a 4.5-nm SiNC would contain around 30 P atoms, whereas a 2.0-nm SiNC would contain only around 3 P atoms. Radial concentration profiles obtained for these SiNCs indicate that the P content is inhomogeneous and possibly enhanced at the boundary as compared to the interior of the NCs. About 20% of the P atoms are found to be incorporated into the SiNCs, whereas roughly 30% are trapped within the interfacial layer (with a thickness of ∼ 0.8 nm); the remainder resides in the surrounding matrix. Cluster-size dependent P concentrations support the view of self-purification in the Si nanostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

H0LiCOW VIII. A weak-lensing measurement of the external convergence in the field of the lensed quasar HE 0435–1223

We present a weak gravitational lensing measurement of the external convergence along the line of sight to the quadruply lensed quasar HE 0435–1223. Using deep r-band images from Subaru Suprime Cam, we observe galaxies down to a 3σ limiting magnitude of ~26 mag resulting in a source galaxy density of 14 galaxies per square arcminute after redshift-based cuts. Using an inpainting technique and multiscale entropy filtering algorithm, we find that the region in close proximity to the lens has an estimated external convergence of κ = -0.012$+0.020\atop{-0.013}$ and is hence marginally under-dense. We also rule out the presence of any halo with a mass greater than M vir = 1.6 × 10 14 h -1 M ⊙ (68 percent confidence limit). Our results, consistent with previous studies of this lens, confirm that the intervening mass along the line of sight to HE 0435–1223 does not affect significantly the cosmological results inferred from the time-delay measurements of that specific object

79 ASTRONOMY AND ASTROPHYSICS↗

The feasibility study and characterization of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance

Purpose: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly {sup 192}Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 μGy m{sup 2}/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named “magic phantom.”Methods: The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array “magic plate” (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the {sup 192}Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a {sup 192}Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ.Results: The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of the epitaxial diodes used in the MP is in good agreement (within 8%) with radial dose function measurements found within the TG-43 protocol, with SDD of up to 70 mm showing a 40% over response. A method for four-dimensional localization of the HDR source was developed, allowing the source dwell position to be derived within 0.50 mm of the expected position. An estimation of the average transit speed for varying step sizes was determined and was found to increase from (12.8 ± 0.3) up to (38.6 ± 0.4) cm/s for a step size of 2.5 and 50 mm, respectively.Conclusions: Our characterization of the designed QA “magic phantom” with MP in realistic HDR photon fields demonstrates the promising performance for real-time source position tracking in four dimensions and measurements of transit times. Further development of this system will allow a full suite for QA in HDR brachytherapy and analysis, and for future in vivo tracking.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reinforcement Learning Approach to Cybersecurity in Space (RELACSS)

Securing satellite groundstations against cyber-attacks is vital to national security missions. However, these cyber threats are constantly evolving. As vulnerabilities are discovered and patched, new vulnerabilities are discovered and exploited. In order to automate the process of discovering existing vulnerabilities and the means to exploit them, a reinforcement learning framework is presented in this report. We demonstrate that this framework can learn to successfully navigate an unknown network and detect nodes of interest despite the presence of a moving target defense. The agent then exfiltrates a file of interest from the node as quickly as possible. This framework also incorporates a defensive software agent that learns to impede the attacking agents progress. This setup allows for the agents to work against each other and improve their abilities. We anticipate that this capability will help uncover unforeseen vulnerabilities and the means to mitigate them. The modular nature of the framework enables users to swap out learning algorithms and modify the reward functions in order to adapt the learning tasks to various use cases and environments. Several algorithms, viz., tabular Q learning, deep Q networks, proximal policy optimization, advantage actor-critic, generative adversarial imitation learning, are explored for the agents and the results highlighted. The agent learns to solve the tasks in a light-weight abstract environment. Once the agent learns to perform sufficiently well, it can be deployed in a minimega virtual machine environment (or a real network) with wrappers that map abstract actions to software commands. The agent also uses a local representation of the actions called a ‘slot-mechanism’. This allows the agent to learn in a certain network and generalize it to different networks. The defensive agent learns to predict the actions taken by an offensive agent and uses that information to anticipate the threat. This information can then either be used to raise an alarm or to take actions to thwart the attack. We believe that with the appropriate reward design, a representative environment, and action set, this framework can be generalized to tackle other cybersecurity tasks. By sufficiently training these agents, we can anticipate vulnerabilities leading to robust future designs. We can also deploy automated defensive agents that can help secure satellite groundstation and their vital national security missions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. Results: HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. Conclusions: For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-236: Monte Carlo Calculations for Radiosurgery of the Clivus

Purpose: We sought to determine if dosimetric differences exist between Ray-Trace (RT) and Monte-Carlo (MC) calculation algorithms for radiosurgery for tumors of the clivus, given their proximity to air-tissue inhomogeneity. Methods: We retrospectively identified 10 patients with a tumor of the clivus where the target was located near an air-tissue interface. CyberKnife treatment was delivered in 1 to 5 fractions. Plans originally calculated with the RT algorithm were re-calculated with the same monitor units (MU) with the MC algorithm. Similarly, plans originally calculated with MC were recalculated with RT. MC calculations were performed using High Resolution with 2% uncertainty on the MultiPlan 4.6 planning system. If the RT plans were originally calculated using water-air density model, they were re-calculated with Body standard density model, and then compared with MC plans computed with Body standard density model. The maximum dose (Dmax) to the planning target volumes (PTV) and critical structures, minimum dose (Dmin) and coverage percentage for the PTV were calculated. Results: For 8 cases, MC PTV Dmin was a median 5% (range 0–10%) and Dmax a median 6% (range 3–9%) higher than for RT. For 2 cases, MC PTV Dmin was 6 and 2% and Dmax was 1 and 3% lower than for RT. MC PTV Dmin and Dmax maybe higher or lower than for RT even though the target coverage for MC was less than for RT (median 4%, range 0–13%) with the same MU used. The degree of differences depends on the location of the target relative to the air-tissue inhomogeneity. Examples are shown that the targets are underdosed near the air-tissue inhomogenity. Conclusion: Monte Carlo dose calculations are recommended for targets near tissue homogeneity such as the clivus. Assuming that Monte Carlo more closely approximates the true dosimetry, the use of Ray Trace could overestimate target coverage.

60 APPLIED LIFE SCIENCES↗

Accelerated fast iterative shrinkage thresholding algorithms for sparsity-regularized cone-beam CT image reconstruction

Purpose: The development of iterative image reconstruction algorithms for cone-beam computed tomography (CBCT) remains an active and important research area. Even with hardware acceleration, the overwhelming majority of the available 3D iterative algorithms that implement nonsmooth regularizers remain computationally burdensome and have not been translated for routine use in time-sensitive applications such as image-guided radiation therapy (IGRT). In this work, two variants of the fast iterative shrinkage thresholding algorithm (FISTA) are proposed and investigated for accelerated iterative image reconstruction in CBCT. Methods: Algorithm acceleration was achieved by replacing the original gradient-descent step in the FISTAs by a subproblem that is solved by use of the ordered subset simultaneous algebraic reconstruction technique (OS-SART). Due to the preconditioning matrix adopted in the OS-SART method, two new weighted proximal problems were introduced and corresponding fast gradient projection-type algorithms were developed for solving them. We also provided efficient numerical implementations of the proposed algorithms that exploit the massive data parallelism of multiple graphics processing units. Results: The improved rates of convergence of the proposed algorithms were quantified in computer-simulation studies and by use of clinical projection data corresponding to an IGRT study. The accelerated FISTAs were shown to possess dramatically improved convergence properties as compared to the standard FISTAs. For example, the number of iterations to achieve a specified reconstruction error could be reduced by an order of magnitude. Volumetric images reconstructed from clinical data were produced in under 4 min. Conclusions: The FISTA achieves a quadratic convergence rate and can therefore potentially reduce the number of iterations required to produce an image of a specified image quality as compared to first-order methods. We have proposed and investigated accelerated FISTAs for use with two nonsmooth penalty functions that will lead to further reductions in image reconstruction times while preserving image quality. Moreover, with the help of a mixed sparsity-regularization, better preservation of soft-tissue structures can be potentially obtained. The algorithms were systematically evaluated by use of computer-simulated and clinical data sets.

60 APPLIED LIFE SCIENCES↗

Scattering approach to dispersive atom-surface interactions

We develop the scattering approach for the dispersive force on a ground state atom on top of a corrugated surface. We present explicit results to first order in the corrugation amplitude. A variety of analytical results are derived in different limiting cases, including the van der Waals and Casimir-Polder regimes. We compute numerically the exact first-order dispersive potential for arbitrary separation distances and corrugation wavelengths, for a Rubidium atom on top of a silicon or gold corrugated surface. We consider in detail the correction to the proximity force approximation, and present a very simple approximation algorithm for computing the potential.

74 ATOMIC AND MOLECULAR PHYSICS↗