Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A short pulse (7 {mu}s FWHM) and high repetition rate (dc-5kHz) cantilever piezovalve for pulsed atomic and molecular beams

In this paper we report on the design and operation of a novel piezovalve for the production of short pulsed atomic or molecular beams. The high speed valve operates on the principle of a cantilever piezo. The only moving part, besides the cantilever piezo itself, is a very small O-ring that forms the vacuum seal. The valve can operate continuous (dc) and in pulsed mode with the same drive electronics. Pulsed operation has been tested at repetition frequencies up to 5 kHz. The static deflection of the cantilever, as mounted in the valve body, was measured as a function of driving field strength with a confocal microscope. The deflection and high speed dynamical response of the cantilever can be easily changed and optimized for a particular nozzle diameter or repetition rate by a simple adjustment of the free cantilever length. Pulsed molecular beams with a full width at half maximum pulse width as low as 7 {mu}s have been measured at a position 10 cm downstream of the nozzle exit. This represents a gas pulse with a length of only 10 mm making it well matched to for instance experiments using laser beams. Such a short pulse with 6 bar backing pressure behind a 150 {mu}m nozzle releases about 10{sup 16} particles/pulse and the beam brightness was estimated to be 4x10{sup 22} particles/(s str). The short pulses of the cantilever piezovalve result in a much reduced gas load in the vacuum system. We demonstrate operation of the pulsed valve with skimmer in a single vacuum chamber pumped by a 520 l/s turbomolecular pump maintaining a pressure of 5x10{sup -6} Torr, which is an excellent vacuum to have the strong and cold skimmed molecular beam interact with laser beams only 10 cm downstream of the nozzle to do velocity map slice imaging with a microchannel-plate imaging detector in a single chamber. The piezovalve produces cold and narrow ({Delta}v/v=2%-3%) velocity distributions of molecules seeded in helium or neon at modest backing pressures of only 6 bar. The low gas load of the cantilever valve makes it possible to design very compact single chamber molecular beam machines with high quality cold and intense supersonic beams. The high speed cantilever piezovalve may find broad applicability in experiments where short and strong gas pulses are needed with only modest pumping, the effective use of (expensive) samples, or the production of cold atomic and molecular beams.

43 PARTICLE ACCELERATORS↗

Colliding Laser Pulses for Laser-Plasma Accelerator Injection Control

Decoupling injection from acceleration is a key challenge to achieve compact, reliable, tunable laser-plasma accelerators (LPA). In colliding pulse injection the beat between multiple laser pulses can be used to control energy, energy spread, and emittance of the electron beam by injecting electrons in momentum and phase into the accelerating phase of the wake trailing the driver laser pulse. At LBNL, using automated control of spatiotemporal overlap of laser pulses, two-pulse experiments showed stable operation and reproducibility over hours of operation. Arrival time of the colliding beam was scanned, and the measured timing window and density of optimal operation agree with simulations. The accelerator length was mapped by scanning the collision point.

43 PARTICLE ACCELERATORS↗

The dynamics of Al/Pt reactive multilayer ignition via pulsed-laser irradiation

Reactive multilayers consisting of alternating layers of Al and Pt were irradiated by single laser pulses ranging from 100 μs to 100 ms in duration, resulting in the initiation of rapid, self-propagating reactions. The threshold intensities for ignition vary with the focused laser beam diameter, bilayer thickness, and pulse length and are affected by solid state reactions and conduction of heat away from the irradiated regions. High-speed photography was used to observe ignition dynamics during irradiation and elucidate the effects of heat transfer into a multilayer foil. For an increasing laser pulse length, the ignition process transitioned from a more uniform to a less uniform temperature profile within the laser-heated zone. A more uniform temperature profile is attributed to rapid heating rates and heat localization for shorter laser pulses, and a less uniform temperature profile is due to slower heating of reactants and conduction during irradiation by longer laser pulses. Finite element simulations of laser heating using measured threshold intensities indicate that micron-scale ignition of Al/Pt occurs at low temperatures, below the melting point of both reactants.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Double-pulse and single-pulse laser-induced breakdown spectroscopy for distinguishing between gaseous and particulate phase analytes

We explore the use of a combination of double-pulse and single-pulse laser-induced breakdown spectroscopy (LIBS) methodologies as a means of differentiating between solid-phase and gaseous-phase analytes (namely, carbon) in an aerosol stream. A range of spectral data was recorded for double-pulse and single-pulse configurations, including both ns and fs prepulse widths, while varying the gas-phase mass percentage of the carbon from about 10% to 90% for various fixed carbon concentrations. The carbon emission response, as measured by the peak-to-continuum ratio, was greater for the double-pulse configuration as compared with the single-pulse response and was also enhanced as the percentage of solid-phase carbon was increased. Using a combination of the double-pulse and single-pulse emission signals, a monotonically increasing response function was found to correlate with the percentage of gas-phase analyte. However, individual data points at the measured gas-phase percentages reveal considerable scatter from the predicted trend. Furthermore, the double-pulse to single-pulse ratio was only pronounced with the ns-ns configuration as compared with the fs-ns scheme. Overall, the LIBS methodology has been demonstrated as a potential means to discriminate between gas-phase and particulate-phase fractions of the same elemental species in an aerosol, although future optimization of the temporal parameters should be explored to improve the precision and accuracy of this approach.

74 ATOMIC AND MOLECULAR PHYSICS↗

Overcoming energy limitation in post-compression of picosecond pulses by free beam propagation in air and temporal pulse splitting and recombining

Cryogenically cooled diode-pumped Yb:YAG has been demonstrated to efficiently generate pulses of >1 J energy and several picoseconds duration at a kilohertz repetition rate. Pulse broadening and post-compression techniques capable of operating at these high pulse energies will expand the use of these lasers in applications requiring shorter pulses. Towards this goal, we demonstrate the post-compression of 5.5 ps pulses with energy in the 0.1 J range by spectral broadening of self-collimated large area beams in air. In proof-of-principle experiments, pulses of 65 mJ energy from a cryogenically cooled Yb:YAG laser were compressed to 1.1 ps after 65 m propagation in a compact setup in which the beam was folded using flat mirrors. Further energy scaling was demonstrated by combining this spectral broadening technique with temporal pulse splitting and recombining. 120 mJ pulses were split into two pulses and coherently recombined with 85% efficiency after 50 m of propagation in air to yield 1.4 ps pulses.

High Energy Laser↗

SU-C-201-03: Ionization Chamber Collection Efficiency in Pulsed Radiation Fields of High Pulse Dose

Purpose: To investigate the reduction of collection efficiency of ionization chambers (IC) by volume recombination and its correction in pulsed fields of very high pulse dose. Methods: Measurements of the collection efficiency of a plane-parallel advanced Markus IC (PTW 34045, 1mm electrode spacing, 300V nominal voltage) were obtained for collection voltages of 100V and 300V by irradiation with a pulsed electron beam (20MeV) of varied pulse dose up to approximately 600mGy (0.8nC liberated charge). A reference measurement was performed with a Faraday cup behind the chamber. It was calibrated for the liberated charge in the IC by a linear fit of IC measurement to reference measurement at low pulse doses. The results were compared to the commonly used two voltage approximation (TVA) and to established theories for volume recombination, with and without considering a fraction of free electrons. In addition, an equation system describing the charge transport and reactions in the chamber was solved numerically. Results: At 100V collection voltage and moderate pulse doses the established theories accurately predict the observed collection efficiency, but at extreme pulse doses a fraction of free electrons needs to be considered. At 300V the observed collection efficiency deviates distinctly from that predicted by any of the established theories, even at low pulse doses. However, the numeric solution of the equation system is able to reproduce the measured collection efficiency across the entire dose range of both voltages with a single set of parameters. Conclusion: At high electric fields (3000V/cm here) the existing theoretical descriptions of collection efficiency, including the TVA, are inadequate to predict pulse dose dependency. Even at low pulse doses they might underestimate collection efficiency. The presented, more accurate numeric solution, which considers additional effects like electric shielding by the charges, might provide a valuable tool for future investigations. This project was funded by the German ministry of research and education (BMBF) under grant number: 03Z1N511 and by the state of Saxony under grant number: B 209.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Fe:ZnSe laser in pulsed and repetitively pulsed regimes

The characteristics of a Fe:ZnSe laser pumped by a single-pulse free-running Er : YAG laser and a repetitively pulsed HF laser are presented. An output energy of 4.9 J is achieved in the case of liquid-nitrogen cooling of the Fe{sup 2+}:ZnSe active laser element longitudinally pumped by an Er:YAG laser with a pulse duration of 1 ms and an energy up to 15 J. The laser efficiency with respect to the absorbed energy is 47%. The output pulse energy at room temperature is 53 mJ. The decrease in the output energy is explained by a strong temperature dependence of the upper laser level lifetime and by pulsed heating of the active element. The temperature dependence of the upper laser level lifetime is used to determine the pump parameters needed to achieve high pulse energies at room temperature. Stable repetitively-pulsed operation of the Fe{sup 2+}:ZnSe laser at room temperature with an average power of 2.4 W and a maximum pulse energy of 14 mJ is achieved upon pumping by a 1-s train of 100-ns HF laser pulses with a repetition rate of 200 Hz. (lasers)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characteristics of quasi-unipolar electromagnetic pulses formed in the interaction of high-power laser pulses with nanoscale targets

A new method is suggested for generating quasi-unipolar electromagnetic IR and terahertz pulses. The method is based on synchronous acceleration of electrons combined to a dense bunch with a charge of up to several tens nanocoulombs, which are forced out from a nanoscale target under an action of a high-power, sharp-leading edge laser pulse. The electromagnetic bunch moving in a field of laser radiation can generate high-power electromagnetic pulses with various spectral composition including terahertz and IR ranges. A physical mechanism underlying the formation of generated quasi-unipolar pulses of electromagnetic radiation is determined and numerically studied. The pulse characteristics are found by numerical simulation, such as amplitude and duration dependences on the angle between the pulse propagation direction and laser beam axis. It is established that in modern laser installations, the amplitudes of quasi-unipolar pulses may reach relativistic values. Reflection of a unipolar pulse from an ideally reflecting surface is numerically analysed. It is shown that the pulse retains its unipolar profile in this case. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dissociative ionization of H{sub 2} in an attosecond pulse train and delayed laser pulse

The ionization of H{sub 2} in a single attosecond extreme ultraviolet (XUV) pulse generates a nuclear wave packet in H{sub 2}{sup +}, which is entangled with the emitted photoelectron wave packet. The nuclear wave-packet dynamics can be observed by dissociating H{sub 2}{sup +} in a delayed IR laser pulse. If H{sub 2} is ionized by a sequence of XUV pulses of an attosecond pulse train, whether or not the corresponding sequence of nuclear wave packets in H{sub 2}{sup +} is detected as a coherent or incoherent superposition depends on whether and how the photoelectrons are observed. We simulate the nuclear dynamics in this XUV-pump-IR-probe scenario and analyze our numerical results for both single attosecond pump pulses and pump-pulse trains of different lengths and temporal spacings between individual XUV pulses. By superimposing nuclear wave packets in H{sub 2}{sup +} generated by individual pulses in the pump-pulse train incoherently, we calculate proton kinetic energy release spectra that are in good qualitative agreement with the recent experiment of Kelkensberg et al. [Phys. Rev. Lett. 103, 123005 (2009)].

74 ATOMIC AND MOLECULAR PHYSICS↗

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

Near-complete extraction of maximum stored energy from large-core fibers using coherent pulse stacking amplification of femtosecond pulses

High field science relies on ultrashort pulse lasers with multi-joule pulse energies for studying light–matter interactions under extreme conditions and for driving particle accelerators and secondary radiation sources of x rays, gamma rays, neutrons, positrons, muons, and protons. Next-generation laser drivers will require a 10 3 -10 4 times increase in pulse repetition rates, producing multi-joule energies at multi-kilowatt average powers to enable practical applications in nuclear engineering, advanced materials, medicine, biology, homeland security, and high-energy physics. Spatially coherently combined femtosecond fiber lasers are recognized as a pathway to these next-generation drivers, with significant practical advantages including high efficiency and the possibility of compact integration. However, chirped pulse amplification in fibers is capable of extracting only a small fraction (usually ~1%) of the maximum stored energy. Here we demonstrate near-complete maximum stored energy extraction with low accumulated nonlinearity from a large-core fiber amplifier using coherent pulse stacking amplification. We have amplified a 81-pulse stacking burst in a 85 µm core chirally coupled core Yb-doped fiber, extracting up to 9.5 mJ (~90% of stored energy) with < 4.5 radians of accumulated nonlinear phase, temporally combined this burst into a single pulse, and achieved 4.2 mJ pulses of 313 fs bandwidth-limited duration after compression. This represents, to our knowledge, the highest energy extracted and compressed into a femtosecond pulse from a single fiber amplifier, enabling approximately two orders of magnitude size reduction of future high-energy coherently spatially combined fiber laser arrays.

47 OTHER INSTRUMENTATION↗

Evaluating pulse-shaping capabilities of next-generation pulsed power architectures

This project evaluated the pulse shaping capabilities of next-generation pulsed power (NGPP) architectures. NGPP architectures share several common attributes including multiple independent pulse-generation lines, a radial water-insulated impedance transformer, and a central vacuum insulated load region. A multi-module circuit model was developed, incorporating independent pulse-generation lines and a 2-D transmission line mesh of the radial impedance transformer to assess the effects of azimuthal asymmetry in pulse-shaped experiments. Circuit model simulations demonstrated that NGPP architectures are able to produce the the desired current pulse shapes for exemplar NGPP experiments. Additionally, the project explored automated methods for experiment design, including derivative -ree optimization and machine learning. Pulse-shaped experiments require designers to determine machine parameters that reliably produce the desired current pulse at the load, a process that typically relies on expert knowledge and iterative adjustments using the Z circuit model. Given the increased complexity of NGPP systems, this manual approach may be impractical. While the evaluated methods do not eliminate the need for manual iteration, they can reduce the time required for experiment design. Derivative-free optimization automates much of the trial-and-error process, providing a close starting point for manual adjustments or making small modifications to near-final designs. Meanwhile, deep neural network methods can generate a good qualitative match to the desired current pulse in under one second without requiring circuit model simulations.

42 ENGINEERING↗

Dual-Pulse Pulse Position Modulation (DPPM) for Deep-Space Optical Communications: Performance and Practicality Analysis

Due to its simplicity and robustness against wavefront distortion, pulse position modulation (PPM) with photon counting detector has been seriously considered for long-haul optical wireless systems. This paper evaluates the dual-pulse case and compares it with the conventional single-pulse case. Analytical expressions for symbol error rate and bit error rate are first derived and numerically evaluated, for the strong, negative-exponential turbulent atmosphere; and bandwidth efficiency and throughput are subsequently assessed. It is shown that, under a set of practical constraints including pulse width and pulse repetition frequency (PRF), dual-pulse PPM enables a better channel utilization and hence a higher throughput than it single-pulse counterpart. This result is new and different from the previous idealistic studies that showed multi-pulse PPM provided no essential information-theoretic gains than single-pulse PPM.

Li, Jing↗

Pulse Energy and Pulse Duration Effects in the Ionization and Fragmentation of Iodomethane by Ultraintense Hard X Rays

The interaction of intense femtosecond x-ray pulses with molecules sensitively depends on the interplay between multiple photoabsorptions, Auger decay, charge rearrangement, and nuclear motion. Here, we report on a combined experimental and theoretical study of the ionization and fragmentation of iodomethane (CH 3 I) by ultraintense (~10 19 W/cm 2 ) x-ray pulses at 8.3 keV, demonstrating how these dynamics depend on the x-ray pulse energy and duration. We show that the timing of multiple ionization steps leading to a particular reaction product and, thus, the product’s final kinetic energy, is determined by the pulse duration rather than the pulse energy or intensity. While the overall degree of ionization is mainly defined by the pulse energy, our measurement reveals that the yield of the fragments with the highest charge states is enhanced for short pulse durations, in contrast to earlier observations for atoms and small molecules in the soft x-ray domain. Finally, we attribute this effect to a decreased charge transfer efficiency at larger internuclear separations, which are reached during longer pulses.

36 MATERIALS SCIENCE↗

Measuring 8–250 ps short pulses using a high-speed streak camera on kilojoule, petawatt-class laser systems

Short-pulse measurements using a streak camera are sensitive to space-charge broadening, which depends on the pulse duration and shape, and on the uniformity of photocathode illumination. An anamorphic-diffuser-based beam-homogenizing system and a space-charge-broadening calibration method were developed to accurately measure short pulses using an optical streak camera. This approach provides a more-uniform streak image and enables one to characterize space-charge-induced pulse-broadening effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A survey of pulse shape options for a revised plastic ablator ignition design

Recent experimental results using the “high foot” pulse shape for inertial confinement fusion ignition experiments on the National Ignition Facility (NIF) [Moses et al., Phys. Plasmas 16, 041006 (2009)] have shown encouraging progress compared to earlier “low foot” experiments. These results strongly suggest that controlling ablation front instability growth can significantly improve implosion performance even in the presence of persistent, large, low-mode distortions. Simultaneously, hydrodynamic growth radiography experiments have confirmed that ablation front instability growth is being modeled fairly well in NIF experiments. It is timely then to combine these two results and ask how current ignition pulse shapes could be modified to improve one-dimensional implosion performance while maintaining the stability properties demonstrated with the high foot. This paper presents such a survey of pulse shapes intermediate between the low and high foot extremes in search of an intermediate foot optimum. Of the design space surveyed, it is found that a higher picket version of the low foot pulse shape shows the most promise for improved compression without loss of stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron energy distributions and electron impact source functions in Ar/N{sub 2} inductively coupled plasmas using pulsed power

In plasma materials processing, such as plasma etching, control of the time-averaged electron energy distributions (EEDs) in the plasma allows for control of the time-averaged electron impact source functions of reactive species in the plasma and their fluxes to surfaces. One potential method for refining the control of EEDs is through the use of pulsed power. Inductively coupled plasmas (ICPs) are attractive for using pulsed power in this manner because the EEDs are dominantly controlled by the ICP power as opposed to the bias power applied to the substrate. In this paper, we discuss results from a computational investigation of EEDs and electron impact source functions in low pressure (5–50 mTorr) ICPs sustained in Ar/N{sub 2} for various duty cycles. We find there is an ability to control EEDs, and thus source functions, by pulsing the ICP power, with the greatest variability of the EEDs located within the skin depth of the electromagnetic field. The transit time of hot electrons produced in the skin depth at the onset of pulse power produces a delay in the response of the EEDs as a function of distance from the coils. The choice of ICP pressure has a large impact on the dynamics of the EEDs, whereas duty cycle has a small influence on time-averaged EEDs and source functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Room temperature optical anisotropy of a LaMnO 3 thin-film induced by ultra-short pulse laser

Ultra-short laser pulse induced optical anisotropy of LaMnO 3 thin films grown on SrTiO 3 substrates were observed by irradiation with a femto-second laser pulse with the fluence of less than 0.1 mJ/cm 2 at room temperature. The transmittance and reflectance showed different intensities for different polarization states of the probe pulse after pump pulse irradiation. The theoretical optical transmittance and re ectance that assumed an orbital ordering of the 3d eg electrons in Mn 3+ ions resulted in an anisotropic time dependent changes similar to those obtained from the experimental results, suggesting that the photo-induced optical anisotropy of LaMnO 3 is a result of photo-induced symmetry breaking of the orbital ordering for an optically excited state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗