Search NASASearch

SEARCH · Search NASA

Results for “pulsed electroacoustic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

40 records · Page 3

Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an in situ alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

general physics

Utilization of Unmanned Aircraft Systems for Environmental Purposes at the Savannah River Site – 26578

Born in the 1950s, the Savannah River Plant was constructed as a plutonium and tritium production plant. As the Cold War era came and went, a change of direction was signaled when the name of the facility changed from Savannah River Plant to Savannah River Site (1989) – the main mission at Savannah River shifted from “production” to “cleanup.” The Department of Energy is responsible for managing the 310 square miles of land that is the Savannah River Site and the cleanup/remediation activities that occur. The Savannah River National Laboratory utilizes unmanned aircraft systems to assist with some of those environmental monitoring and remediation activities. One function of unmanned aircraft systems at the Savannah River National Laboratory is conducting aerial photography and videography. Various infrastructure evaluations have been performed with unmanned aircraft – facility rooftop inspections, water tower lock verifications, earthen dam surveys, etc. An unmanned aircraft system has been used for progress footage of remediation projects – Dunbarton Bay remediation, Saltstone Disposal Unit construction, etc. Thermal cameras on an unmanned aircraft system are used to help identify cracks/leaks in structures from vantage points not readily accessible by personnel. Virtual tours of different waste units are conducted with unmanned aircraft systems for Site groups and federal/state regulators to save costs and travel time. Additionally, advanced remote sensing technologies are used on unmanned aircraft systems at the Savannah River Site. Light Detection and Ranging uses laser pulses to measure distances to the Earth's surface or other targets to create highly detailed topographic maps that accurately portray terrain (e.g., elevation changes, slopes, and contours). Data collection with a Light Detection and Ranging unit mounted on an unmanned aircraft system is quick and efficient – large-area surveys are conducted in shorter time frames. Because Light Detection and Ranging can penetrate through foliage and vegetation to ground level, it is being used in conjunction with a watershed model to study the General Separations Area of the Site to determine stormwater flow volume and direction, monitor stream stability, and forecast river flow behavior. A hyperspectral camera captures a wide spectrum of electromagnetic wavelengths across numerous narrow bands, beyond what the human eye can see. It provides detailed spectral information about the objects or surfaces in an image, which can be used to identify and analyze materials based on their spectral signatures. A hyperspectral camera mounted on an unmanned aircraft system has been used at the Savannah River Site for non-destructive evaluation of concrete and concrete structures. Unmanned aircraft systems at the Savannah River Site are also used for the application of herbicide on identified rooftops. P-Reactor and R-Reactor are entombed nuclear reactors at the Savannah River Site. Unwanted vegetation is often present on these rooftops – over time roots can penetrate seams, cracks, and joints of the general roof and concrete caps, leading to water ingress and deterioration of the structural components. For time and cost efficiencies as well as in the interest of personnel safety, an unmanned aircraft is used to dispense herbicide on rooftop areas where vegetation is noticed to help alleviate the issues/hazards.

Lorier, Troy [Savannah River National Laboratory (

Recrystallization, cracking, and erosion of dispersoid-strengthened tungsten materials during exposure to divertor plasmas

In this study, we investigated the effects of combined intense particle and heat flux exposure on advanced tungsten plasma-facing materials within the DIII-D fusion facility. Our test matrix included two types of dispersoid-strengthened tungsten (containing either 100 nm diameter TiO 2 or Ni particles), along with high-purity polycrystalline tungsten as a reference. This experiment relied on a sample geometry angled at 15° relative to the divertor surface, thereby allowing the surfaces to intercept steady-state perpendicular heat fluxes (q ⟂ ) ranging from 10.1 to 19.6 MW/m 2 . During each shot, the samples were exposed to 42 Hz edge-localized modes (ELMs), allowing us to test the material response to transient heating. We correlated the exposure conditions with extensive post-test surface composition analysis and microscopy to determine how the plasma modified each surface. The angled specimens closest to the strike point received the highest combined heat and particle flux and melted midway through the experiment. EBSD analysis revealed they were completely recrystallized throughout, with an average grain size >100 µm. On the other hand, the specimens that received a lower steady state heat flux survived with more superficial surface damage. Whereas the high-purity polycrystalline tungsten exhibited a higher surface roughness, the dispersoid-strengthened material exhibited more extensive shallow inter-granular cracking. In addition, the surface was depleted of dispersoids following plasma exposure, possibly because of evaporation and/or sputtering. The results described here provide insights into the performance of these materials in a fusion environment which can guide further optimization for use in long-pulse devices.

Kolasinski, Robert D. [Sandia National Laboratorie

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN