Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulsed field magnetization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Field-induced spin level crossings within a quasi-$XY$ antiferromagnetic state in $Ba$ 2 $FeSi$ 2 $O$ 7

Here, we present a high-field study of the strongly anisotropic easy-plane square lattice $S$ = 2 quantum magnet $Ba$ 2 $FeSi$ 2 $O$ 7 . This compound is a rare high-spin antiferromagnetic system with very strong easy-plane anisotropy, such that the interplay between spin level crossings and antiferromagnetic order can be studied. We observe a magnetic field-induced spin level crossing occurring within an ordered state. This spin level crossing appears to preserve the magnetic symmetry while producing a nonmonotonic dependence of the order parameter magnitude. The resulting temperature–magnetic field phase diagram exhibits two dome-shaped regions of magnetic order overlapping around 30 T. The ground state of the lower-field dome is predominantly a linear combination of |$S^z$ = 0$\rangle$ and |$S^z$ = 1$\rangle$ states, while the ground state of the higher-field dome can be approximated by a linear combination of |$S^z$ = 1$\rangle$ and |$S^z$ = 2$\rangle$ states. At 30 T, where the spin levels cross, the magnetization exhibits a slanted plateau, the magnetocaloric effect shows a broad hump, and the electric polarization shows a weak slope change. We determined the detailed magnetic phase boundaries and the spin level crossings using measurements of magnetization, electric polarization, and the magnetocaloric effect in pulsed magnetic fields to 60 T. Furthermore, we calculate these properties using a mean-field theory based on direct products of SU(5) coherent states and find good agreement. Finally, we measure and calculate the magnetically induced electric polarization that reflects magnetic ordering and spin level crossings. This multiferroic behavior provides another avenue for detecting phase boundaries and symmetry changes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Canted standing spin-wave modes of permalloy thin films observed by ferromagnetic resonance

Non-collinear spin structures in materials that combine perpendicular and in-plane magnetic anisotropies are of great technological interest for microwave and spin wave-assisted magnetization switching. [Co/Pt] multilayers are well-known perpendicular anisotropy materials that have the potential to pin the magnetization of a soft magnetic layer, such as permalloy (Py), that has in-plane anisotropy, thereby forming a magnetic exchange spring. Here we report on multilayered [Co/Pt]/Pt/Py films, where an additional ultrathin Pt spacer has been included to control the coupling between the sub-units with in-plane and perpendicular magnetic anisotropy. Vector network analyser (VNA)-ferromagnetic resonance (FMR) measurements were made to obtain a complete picture of the resonant conditions, while the dynamical response of the sub-units was probed by synchrotron-based element- and phase selective x-ray detected FMR (XFMR). For all samples, only slight pinning of the dynamic magnetization of the Py by the [Co/Pt] was noted, and the FMR results were dominated by the 50 nm thick Py layer. Out-of-plane VNA-FMR maps reveal the presence of additional modes, e.g. a perpendicular standing spin-wave (PSSW) state. However, as the magnetic field is reduced below the saturation field, the PSSW state morphs continuously through a series of canted standing spin-wave (CSSW) states into a horizontal standing spin-wave (HSSW) state. The PSSW, CSSW and HSSW states are well described using a multilayer model of the Py film. The observation of CSSW modes is of particular relevance to microwave assisted magnetic recording, where microwave excitation stimulates precession of a soft layer canted out of plane by a pulsed magnetic field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Theta-Pinch Thruster for Piloted Deep Space Exploration

A new high-power propulsion concept that combines a rapidly pulsed theta-pinch discharge with upstream particle reflection by a magnetic mirror was evaluated under a Phase 1 grant awarded through the NASA Institute for Advanced Concepts. Analytic and numerical models were developed to predict the performance of a theta-pinch thruster operated over a wide range of initial gas pressures and discharge periods. The models indicate that a 1 m radius, 10 m long thruster operated with hydrogen propellant could provide impulse-bits ranging from 1 N-s to 330 N-s with specific impulse values of 7,500 s to 2,500 s, respectively. A pulsed magnetic field strength of 2 T is required to compress and heat the preionized hydrogen over a 10(exp -3) second discharge period, with about 60% of the heated plasma exiting the chamber each period to produce thrust. The unoptimized thruster efficiency is low, peaking at approximately 16% for an initial hydrogen chamber pressure of 100 Torr. The specific impulse and impulse-bit at this operating condition are 3,500 s and 90 N-s, respectively, and the required discharge energy is approximately 9x10(exp 6) J. For a pulse repetition rate of 10 Hz, the engine would produce an average thrust of 900 N at 3,500 s specific impulse. Combined with the electrodeless nature of the device, these performance parameters indicate that theta-pinch thrusters could provide unique, long-life propulsion systems for piloted deep space mission applications.

LaPointe, Mike R.↗

Enhancing easy-plane anisotropy in bespoke Ni(II) quantum magnets

We examine the crystal structures and magnetic properties of several S = 1 Ni(II) coordination compounds, molecules and polymers, that include the bridging ligands HF 2 - , A F 6 2- ( A = Ti, Zr) and pyrazine or non-bridging ligands F - , SiF 6 2- , glycine, H 2 O, 1-vinylimidazole, 4-methylpyrazole and 3-hydroxypyridine. Pseudo-octahedral NiN 4 F 2 , NiN 4 O 2 or NiN 4 OF cores consist of equatorial Ni-N bonds that are equal to or slightly longer than the axial Ni- L ax bonds. By design, the zero-field splitting ( D ) is large in these systems and, in the presence of substantial exchange interactions ( J ), can be difficult to discriminate from magnetometry measurements on powder samples. Thus, we relied on pulsed-field magnetization in those cases and employed electron-spin resonance (ESR) to confirm D when J ← D . The anisotropy of each compound was found to be easy-plane ( D > 0) and range from ≈ 8–25 K. This work reveals a linear correlation between the ratio d (Ni- L ax )/ d (Ni-N eq ) and D although the ligand spectrochemical properties may play an important role. We assert that this relationship allows us to predict the type of magnetocrystalline anisotropy in tailored Ni(II) quantum magnets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum-limit phenomena and band structure in the magnetic topological semimetal EuZn 2 As 2

The interplay between magnetism and electronic topology in the quantum limit is a forefront subject of condensed matter physics. Here, we show the electronic and magnetic properties of layered antiferromagnet EuZn 2 As 2 in pulsed magnetic fields up to 60 T and temperatures down to 0.6 K. By analyzing the quantum oscillations observed in the magnetoresistance (MR) and proximity detector oscillator (PDO) frequency, we find that (1) the oscillation frequency F = 46 ± 6 T for H // c and 42 ± 2 T for H // ab; (2) the corresponding Berry phase is close to π for H // c, implying a nontrivial topology; and (3) the large linear MR occurs beyond the first Landau level, without any sign of saturation. From these observations, we conclude that the linear MR can be understood by considering diffusing cyclotron centers due to compressed Landau wavefunction, an emergent behavior in the quantum limit.

36 MATERIALS SCIENCE↗

Piezomagnetic switching and complex phase equilibria in uranium dioxide

Abstract Actinide materials exhibit strong spin–lattice coupling and electronic correlations, and are predicted to host new emerging ground states. One example is piezomagnetism and magneto-elastic memory effect in the antiferromagnetic Mott-Hubbard insulator uranium dioxide, though its microscopic nature is under debate. Here, we report X-ray diffraction studies of oriented uranium dioxide crystals under strong pulsed magnetic fields. In the antiferromagnetic state a [888] Bragg diffraction peak follows the bulk magnetostriction that expands under magnetic fields. Upon reversal of the field the expansion turns to contraction, before the [888] peak follows the switching effect and piezomagnetic ‘butterfly’ behaviour, characteristic of two structures connected by time reversal symmetry. An unexpected splitting of the [888] peak is observed, indicating the simultaneous presence of time-reversed domains of the 3-k structure and a complex magnetic-field-induced evolution of the microstructure. These findings open the door for a microscopic understanding of the piezomagnetism and magnetic coupling across strong magneto-elastic interactions.

36 MATERIALS SCIENCE↗

THz cyclotron resonance of a 2D hole gas in a GaN/AlN heterostructure

The recent discovery of highly conducting two-dimensional hole gases (2DHGs) in GaN/AlN heterojunctions has opened the door to efficient complementary GaN electronics, a long-standing challenge in wide-bandgap semiconductor device physics. Electrical transport studies and simulations indicate that both heavy- and light-hole valence bands are occupied in these 2DHGs, but direct experimental characterization of the fundamental parameters of the mobile holes remains at an early stage. Here, we use time-domain terahertz spectroscopy and pulsed magnetic fields up to 31 T to directly measure cyclotron resonance of the mobile 2D holes in these GaN-based 2DHGs at low temperature (8 K), revealing key material properties including effective masses, densities, scattering times, and mobilities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sputtered Au–Ta films with tunable electrical resistivity

Gold–tantalum alloy films are attractive for hohlraums used in indirect drive magnetized inertial confinement fusion. A high electrical resistivity of over ~100 µΩ cm at cryogenic temperatures is an essential requirement for allowing an externally imposed pulsed magnetic field to soak through a hohlraum and magnetize the fusion fuel. In this work, we systematically study properties of Au–Ta alloy films in the entire compositional range from pure Au to pure Ta with thicknesses up to 30 µm. These films are made by direct current magnetron co-sputtering on planar substrates. Films are characterized by a combination of high-energy ion scattering, x-ray diffraction, electron microscopy, nanoindentation, and electrical transport measurements. Results show that an alloy with ~80 at.% of Ta forms a metallic glass exhibiting a maximum electrical resistivity of ~300 µΩ cm with a weak temperature dependence in the range of 5–400 K. The deposition of a film with ~80 at.% of Ta onto a sphero-cylindrical substrate for hohlraum fabrication is also demonstrated.

36 MATERIALS SCIENCE↗

Observation of cyclotron resonance and measurement of the hole mass in optimally doped La 2–x Sr x CuO 4

Using time-domain terahertz spectroscopy in pulsed magnetic fields up to 31 T, we measure the terahertz optical conductivity in an optimally doped thin film of the high-temperature superconducting cuprate La 1.84 Sr 0.16 CuO 4 . We observe systematic changes in the circularly polarized complex optical conductivity that are consistent with cyclotron absorption of p-type charge carriers characterized by a cyclotron mass of 4.9m e ± 0.8m e and a scattering rate that increases with magnetic field. Furthermore, these results open the door to studies aimed at characterizing the degree to which electron-electron interactions influence carrier masses in cuprate superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic anisotropy and two-dimensional short-range chemical ordering in Ba 1−𝑥 ⁢Na 𝑥 ⁢Fe 2 ⁢As 2

A true understanding of the properties of pnictide superconductors requires the development of high-quality materials and performing measurements designed to unravel their intrinsic properties and short-range nematic correlations which are often obscured by extrinsic effects such as poor crystallinity, inhomogeneity, domain formation, and twinning. Here, in this paper, we report the systematic growth of high-quality Na-substituted BaFe 2 As 2 single crystals and their characterization using pulsed magnetic fields x-ray diffraction and x-ray diffuse scattering. Analysis of the properties and compositions of the highest-quality crystals shows that their actual Na stoichiometry is about 50-60% of the nominal content and that the targeted production of crystals with specific compositions is accessible. We derived a reliable equation to estimate the Na stoichiometry based on the measured superconducting T c of these materials. Attempting to force spin reorientation and induce tetragonality, orthorhombic Ba 1-x Na x Fe 2 As 2 single crystals subjected to out-of-plane magnetic fields up to 31.4T are found to exhibit strong in-plane magnetic anisotropy demonstrated by the insufficiency of such high fields in manipulating the relative population of their twinned domains or in suppressing the orthorhombic order. Broad x-ray diffuse-intensity rods observed at temperatures between 30 and 300 K uncover short-range structural correlations. Local structure modeling together with 3D-Δ pair-distribution function mapping of real-space interatomic vectors show that the diffuse scattering arises from in-plane short-range chemical correlations of the Ba and Na atoms coupled with short-range atomic displacements within the same plane due to an effective size difference between the two atomic species.

36 MATERIALS SCIENCE↗

Electromagnetic hammer removes weld distortions from aluminum tanks

Distortions around weld areas on sheet-aluminum tanks and other structures are removed with a portable electromagnetic hammer. The hammer incorporates a coil that generates a controlled high-energy pulsed magnetic field over localized areas on the metal surface.

Schwinghamer, R. J.↗

Mass drivers. 1: Electrical design

A mass driver is an electrical device used to accelerate payloads of any material to a high velocity. Small vehicles (called buckets) containing superconducting coils carry the payloads. These buckets are accelerated by pulsed magnetic fields, timed by information on their position, and are guided by induced magnetic fields set up in a surrounding guideway. Upon reaching the correct velocity, the buckets release their payloads, then they are slowed for recirculation to be reused. A rationale is presented that leads to a relatively simple and near-optimum design, as well as basic programs for calculating acceleration. The transverse oscillation frequencies are found to be invariant to guideway transverse dimensions.

William H. Arnold↗

Magnetically induced cylindrical stress waves in a thermoelastic conductor

The problem of stress wave generation in a linear thermoelastic solid by a pulsed magnetic field is investigated both analytically and experimentally for a cylindrically symmetric conducting solid. A dynamic response analysis is developed to correlate magnetic, thermal, and stress fields in the solid with the time history of the electric current. In the experiment, a transient magnetic field was applied normal to a large conducting plate with a circular hole. Initially the field was confined to the interior of the circular hole. The field was generated by discharging a large capacitor bank through a solenoidal coil. The plane-stress cylindrical stress waves are 1-D in nature. The relative effects of the magnetic body force and thermoelastic stresses, both generated by the electromagnetic field, are assessed.

Chian, C. T.↗

Countermeasures to microgravity

Biological systems ranging from the most simple to the most complex generally survive exposure to microgravity. Changes in many characteristics of biological systems are well documented as a consequence of space flight. Attempts to devise countermeasures to microgravity may have direct pragmatic consequences for crew protection and may provide additional insights into the nature of microgravity influences on biological systems. Some of the most well documented changes occur in humans who have experienced space flight. Changes appear to be transient. Space adaption syndrome occurs relatively briefly whereas bone deterioration may require months of postflight time for restoration. It seems critical to recognize that these changes and others may derive from rather passive, active or even reactive changes in the biological systems that are hosts to them. For example, hydrostatic fluid redistributions may be quite passive occurrences that are realized through extensive fluid channels. Changes occur in cell metabolism because of fluid, nutrient and gas redistributions. Equally important are the misconstrued messages likely to be carried by fluid redistributions. These reactive events can trigger, for example, loss of fluids and electrolytes through altered kidney function. Each of these considerations must be evaluated in regard to the biological site affected. Countermeasures to the vast range of biological changes and sites are difficult to envision. The most obvious countermeasure is the restoration of gravity-like influences. Some options are discussed. Recent work has focussed on the use of magnetic fields. Pulsed electromagnetic fields (PEMF) are shown to alleviate bone deterioration produced in rodents exposed to tail suspension. Methods of PEMF exposure are consistent with human use in space. Related methods may provide muscular and neural benefits.

Luttges, Marvin W.↗

Measurement of hand dynamics in a microsurgery environment: Preliminary data in the design of a bimanual telemicro-operation test bed

Data describing the microsurgeon's hand dynamics was recorded and analyzed in order to provide an accurate model for the telemicrosurgery application of the Bimanual Telemicro-operation Test Bed. The model, in turn, will guide the development of algorithms for the control of robotic systems in bimanual telemicro-operation tasks. Measurements were made at the hand-tool interface and include position, acceleration and force between the tool-finger interface. Position information was captured using an orthogonal pulsed magnetic field positioning system resulting in measurements in all six degrees-of-freedom (DOF). Acceleration data at the hands was obtained using accelerometers positioned in a triaxial arrangement on the back of the hand allowing measurements in all three cartesian-coordinate axes. Force data was obtained by using miniature load cells positioned between the tool and the finger and included those forces experienced perpendicular to the tool shaft and those transferred from the tool-tissue site. Position data will provide a minimum/maximum reference frame for the robotic system's work space or envelope. Acceleration data will define the response times needed by the robotic system in order to emulate and subsequently outperform the human operator's tool movements. The force measurements will aid in designing a force-reflective, force-scaling system as well as defining the range of forces the robotic system will encounter. All analog data was acquired by a 16-channel analog-to-digital conversion system residing in a IBM PC/AT-compatible computer at the Center's laboratory. The same system was also used to analyze and present the data.

Charles, Steve↗

NASA Tech Briefs, February 2004

Topics include: Simulation Testing of Embedded Flight Software; Improved Indentation Test for Measuring Nonlinear Elasticity; Ultraviolet-Absorption Spectroscopic Biofilm Monitor; Electronic Tongue for Quantitation of Contaminants in Water; Radar for Measuring Soil Moisture Under Vegetation; Modular Wireless Data-Acquisition and Control System; Microwave System for Detecting Ice on Aircraft; Routing Algorithm Exploits Spatial Relations; Two-Finger EKG Method of Detecting Evasive Responses; Updated System-Availability and Resource-Allocation Program; Routines for Computing Pressure Drops in Venturis; Software for Fault-Tolerant Matrix Multiplication; Reproducible Growth of High-Quality Cubic-SiC Layers; Nonlinear Thermoelastic Model for SMAs and SMA Hybrid Composites; Liquid-Crystal Thermosets, a New Generation of High-Performance Liquid-Crystal Polymers; Formulations for Stronger Solid Oxide Fuel-Cell Electrolytes; Simulation of Hazards and Poses for a Rocker-Bogie Rover; Autonomous Formation Flight; Expandable Purge Chambers Would Protect Cryogenic Fittings; Wavy-Planform Helicopter Blades Make Less Noise; Miniature Robotic Spacecraft for Inspecting Other Spacecraft; Miniature Ring-Shaped Peristaltic Pump; Compact Plasma Accelerator; Improved Electrohydraulic Linear Actuators; A Software Architecture for Semiautonomous Robot Control; Fabrication of Channels for Nanobiotechnological Devices; Improved Thin, Flexible Heat Pipes; Miniature Radioisotope Thermoelectric Power Cubes; Permanent Sequestration of Emitted Gases in the Form of Clathrate Hydrates; Electrochemical, H2O2-Boosted Catalytic Oxidation System; Electrokinetic In Situ Treatment of Metal-Contaminated Soil; Pumping Liquid Oxygen by Use of Pulsed Magnetic Fields; Magnetocaloric Pumping of Liquid Oxygen; Tailoring Ion-Thruster Grid Apertures for Greater Efficiency; and Lidar for Guidance of a Spacecraft or Exploratory Robot.

Source record↗

Challenges in Pulsed-Field Gradient Nuclear Magnetic Resonance on Magnetically Heterogeneous Interfaces: Sequence and Field-Dependent Apparent Diffusion Coefficients

It is well known that the internal gradient (gi) that exists within pores haunts the diffusion coefficient (D) as measured by the pulsed-field gradient (PFG) nuclear magnetic resonance (NMR). Several PFG-NMR methods developed to determine an accurate D were not successful. Then, the steady-state diffusion coefficient (Dapp,8) for the cation [C4mim]+ of [C4mim][Tf2N]; [1-butyl-3-methylimidazolium][bis(trifluoromethylsulfonyl)imde] ionic liquid confined in ordered mesoporous carbon (OMC) were determined by comparing Dapp,8 obtained from 1H PFG-NMR performed with three different stimulated echo sequences: STE, APFG, and MPFG under the two external magnetic field strength, B0 = 9.4 and 14.1 Tesla. The measured Dapp,8 which is an order of magnitude smaller than D of bulk [C4mim][Tf2N], is in good agreement between APFG and MPFG both in B0 = 9.4 and 14.1 Tesla. However, the strong gi artifact, which caused apparent diffusion coefficient (Dapp) depending strongly and weakly on B0 and temperature, respectively, in diffusion-time dependent Dapp, Dapp(?) obtained from a sequence with monopolar gradients (STE) was suppressed by using sequences employing bipolar gradients (APFG and MPFG) in the region of steady-state diffusion. But incompletely suppressed gi artifact resulting in the different behaviors of the early part of Dapp(?) between the sequences leads a ˜ 0.6 and 0.9 in MPFG and APFG, respectively, in the relationship between mean squared displacement and diffusion time: = 2Dta, where a = 0.5 and 1 for 1-dimensional single file diffusion and 3-dimensional bulk diffusion, respectively. The above observations clearly show that the diffusion behavior of ions/molecules within the pores and pore structure, such as the surface-to-volume ratio? (D?_app (?)=D_0 [1-4/(9vp) S/V v(D_0 ?)]) and tortuosity (T = D0/Dapp,8), are possible to be misunderstood, especially in the systems with a non-negligible gi. This work demonstrates that it may be necessary to test several PFG sequences under multiple external magnetic fields for the correct determination of the diffusion behavior of ions/molecules in the pores with a larger internal gradient, gi.

Han, Kee Sung↗