Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulsed sample delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

40 records · Page 3

High-bandwidth image-based predictive laser stabilization via optimized Fourier filters

Controlling the delivery of kHz-class pulsed lasers is of interest in a variety of industrial and scientific applications, from next-generation laser-plasma acceleration to laser-based x-ray emission and high-precision manufacturing. The transverse position of the laser pulse train on the application target is often subject to fluctuations by external drivers (e.g., room cooling and heating systems, motorized optics stages and mounts, vacuum systems, chillers, and/or ground vibrations). For typical situations where the disturbance spectrum exhibits discrete peaks on top of a broad-bandwidth lower-frequency background, traditional PID (proportional-integral-derivative) controllers may struggle, since as a general rule PID controllers can be used to suppress vibrations up to only about 5%–10% of the sampling frequency. Here, a predictive feed-forward algorithm is presented that significantly enhances the stabilization bandwidth in such laser systems (up to the Nyquist limit at half the sampling frequency) by online identification and filtering of one or a few discrete frequencies using optimized Fourier filters. Furthermore, the system architecture demonstrated here uses off-the-shelf CMOS cameras and piezo-electric actuated mirrors connected to a standard PC to process the alignment images and implement the algorithm. To avoid high-end, high-cost components, a machine-learning-based model of the piezo mirror’s dynamics was integrated into the system, which enables high-precision positioning by compensating for hysteresis and other hardware-induced effects. A successful demonstration of the method was performed on a 1 kHz laser pulse train, where externally-induced vibrations of up to 400 Hz were attenuated by a factor of five, far exceeding what could be done with a standard PID scheme.

Natal, Joseph↗

Modelling pulsed field magnetization of iron-based bulk superconductors

Abstract Bulk superconductors can be used as super-strength quasi-permanent magnets capable of providing magnetic flux densities considerably superior to conventional permanent magnets. This makes them attractive for several engineering applications that rely on strong magnetic fields like rotating machines, NMR/MRI and magnetic drug delivery systems. Recently, the authors reported a record trapped magnetic field in an iron-based bulk superconductor: 2.83 T was trapped in potassium-doped barium iron arsenide (Ba, K)Fe 2 As 2 (or Ba122) at 5 K. Of particular significance is that the strength and temporal stability of this magnetic field exceeds the requirements of MRI machines, indicating iron-based bulks can now perform at levels demanded by engineering applications. One crucial challenge for their practical use, however, is the need to apply and remove an external magnetic field to magnetize them. Pulsed field magnetization (PFM) shows great promise as a practical method of magnetizing bulks, but the process generates heat in the bulk that is detrimental to its superconducting performance and ability to act as a super-strength magnet. In this paper, coupled electromagnetic–thermal numerical models are used to simulate the PFM of iron-based bulk superconductors. Here we focus on the recent-record-breaking, fine-grain polycrystalline K-doped Ba122 bulks. The impact that the specific J c ( B ) characteristics and thermal properties of the Ba122 material—all of which have been experimentally measured from state-of-the-art samples—have on the magnetic flux dynamics and thermal behaviour during PFM, including the final trapped field, is investigated. We show that because the thermal properties are similar to those of REBa 2 Cu 3 O 7 −δ bulks, a similar response to pulsed fields is obtained. A maximum trapped field of ∼0.81 T (∼43.3% of the maximum trapped field capability under ideal, field-cooling conditions) was simulated at 5 K, with a magnetization efficiency of ∼54%. The modelling framework provides a fast and flexible tool for optimising the practical PFM process at different operating temperatures to maximise the trapped field in state-of-the-art Ba122 bulks and to guide the design of future experiments.

bulk superconductors↗

The Dragonfly Entry and Descent System

Dragonfly is a proposed New Frontiers class mission that will send a nuclear powered octocopter to the surface of Titan for an extended science mission. This presentation will provide an overview of the Entry and Descent system that is under development to ensure the save delivery of this unique "relocatable lander" to Titan. Titan's dense atmosphere, large atmospheric scale height, and low gravity allows for a slow-paced entry and descent sequence that lasts more than 100 minutes, as opposed to the "7 minutes of terror" that is charac-teristic of landed Mars missions. This slow pace al-lows for sufficient temporal separation between critical events of the EDL sequence to minimize overall risk.The Dragonfly entry and descent system is composed of high-heritage components, minimizing overall risk. The aeroshell will be a scaled Genesis Sample Return capsule with a diameter of 3.75 meters, built by Lock-heed Martin. The thermal protection system (TPS) is made up of Phenolic Impregnated Carbon Ablator-Domestic (PICA-D) on the heatshield, SLA-561V on the backshell, and SLA-220M on the aft cover and low gain antenna. Each material has extensive heritage for the chosen application. The spacecraft will enter Titan at a velocity of 7.3 km/s, resulting in a predicted fully margined stagnation point heating environment of 254 W/cm2 heat rate and 13 kJ/cm2 heat load, well within the tested limits of the chosen materials. The aeroheat-ing environments, including the significant contribu-tion of shock layer radiation from CN on both the heatshield and backshell, are evaluated using state of the art models and codes that have been validated with appropriate ground testing.Once the deceleration pulse is complete, a disk-gap-band (DGB) drogue parachute will be deployed at ap-proximately Mach 1.5 to stabilize and further deceler-ate the spacecraft. Due to the dense atmosphere, the spacecraft will spend more than 80 minutes on this parachute, until reaching an appropriate altitude to de-ploy the subsonic main parachute. The lander is re-leased after approximately 17 minutes on the main chute before releasing and transitioning to powered flight in order to navigate to its first landing site. The release of the lander from the backshell effectively ends the entry and descent portion of the mission.The full presentation will provide additional details about the design of the EDL system hardware, engi-neering design, and overall con-ops. Preliminary aero-thermal and TPS sizing analyses will be presented, and the parachute system will be described in greater detail. In addition, the Dragonfly spacecraft will carry an En-gineering Science Investigation (ESI) package designed to obtain engineering data during EDL that will be used to validate the design methodology for future missions. An overview of the proposed ESI package will also be presented.

EDL↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗