Search NASA⌕ Search

SEARCH · Search NASA

Results for “pumping test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimization Considerations for Annular Linear Electromagnetic Pumps for Space Nuclear Power and Propulsion

The Need for High Performance Liquid Metal Pumps Testing Power and Efficiency Considerations Liquid metal cooled reactors is one option for space nuclear power for settlements and electric propulsion vehicles (Snap 10 A, SP100, Soviet Topaz reactors) • High heat capacity • High boiling point (NaK~1200K) • Simplified heat transfer loop • Good neutronics Liquid metal EM pumps are desired over conventional pumps owing to lack of seals, bearings elimination of cavitation issues, lower mass and eliminates mechanical impeller • Conduction pumps (typically DC-high current, low voltage; ~5% efficiency) • Induction pumps (typically AC, high efficiency ~40%) Annular linear induction pump is an EM pump with no moving parts and of cylindrical/tubular geometry which makes it straightforward to integrate in conventional piping architectures • Higher inherent reliability • Invented by Einstein and Szilard

ALIP↗

Design and test of a pumped two-phase mounting plate

The design, fabrication, and testing of the full-scale development unit of a pumped two-phase mounting plate (TPMP) used in advanced two-phase spacecraft thermal control systems are described. The mounting plate is tested with R-11 in the evaporator mode for total heat loads of over 3000 watts and local heat fluxes over 4 W/sq cm, and in the condenser mode with condenser loads from 60 to 400 watts and inlet qualities from 8 to 94 percent. The calculated heat-transfer coefficients are between 0.66 and 1.0 W/sq cm/C and are nearly independent of the flow rate and heat load except at very low heat loads. It is shown that the TPMP can be run with inlet conditions down to 22 C subcooling without any significant gradients in the plate and that it performs well with nonuniform heat fluxes.

Grote, M. G.↗

Dynamics of cavitating cascades

The unsteady dynamics of cavitating cascades and inducer pumps were studied with a view to understanding (and possibly predicting) the dynamic characteristics of these devices. The chronology of the research is summarized as well as the final conculsions for each task. The construction of a dynamic pump test facility and its use in making experimental measurements of the transfer function is described as well as tests conducted using a scale model of the low pressure liquid oxygen turbopump inducer in the shuttle main engine. Auto-oscillation and unsteady inlet flow characteristics are discussed in addition to blade cavity influence and bubbly cavitation.

Brennen, C. E.↗

Turbomachinery incipient failure dynamic detection indicators and analysis

Tape recorded signals from case-mounted accelerometers are examined to determine the feasibility of detecting spalls on bearing balls in the liquid oxygen (LOX) pump in the Space Shuttle Main Engine (SSME). The nonperiodic nature of the spall impact on inner and outer bearing races caused traditional techniques to be unsuccessful. A technique involving statistical techniques and spectra ratios was used to review available pump test tapes.

Faby, D. R.↗

Finite element analysis of the Space Shuttle Main Engine (SSME) alternate turbopump development (ATD) high pressure oxydizer turbopump (HPOTP)

A 3D model of all stationary components of the ATD HPOTP is analyzed using a superelement solution technique to obtain a better understanding of the pump behavior and to support pump testing. Emphasis is place on the methods used for determining deflections. As part of the model verification, analyses were conducted on the main housing model under proof-pressure and push-test loading conditions. The analysis at 109 percent rate power level resulted in asymmetric deformation patterns which were used to calculate operating and rub clearances. The present analysis is considered to provide the most realistic representation of the ATD HPOTP to date.

Ham-Battista, G. L.↗

Performance test of a laboratory pump liquid transfer based on the fountain effect

A laboratory scale pump has been tested in detail in order to determine the flow characteristics of a heater-activated all-metal thermomechanical pump (fountain effect pump, FEP). The emphasis is on the functional dependence of the fountain pressure difference versus mass throughput. A modified Vote et al. (1971) power law approximation is employed for a simplified description of the flow rate as a function of the driving force. Flow rates of up to 10 liters/(hr/sq cm) have been obtained despite a large nominal pore size of the porous plug of 2 microns (filtration rating) used for the FEP.

Chen, W. E. W.↗

Scroll Pump Dust Tolerance Test for Martian Atomospheric Acquisition

The ability to generate oxygen on the Martian surface will be essential to establishing a human presence on Mars. Flow generating devices such as pumps, compressors, and blowers will be essential components in Martian atmospheric acquisition and processing systems that need to work reliably during the mission duration. A concern with the reliability of the system is its ability to continue to perform nominally when Martian dust, if it bypasses the inlet filter, enters into the system. A series of tests were conducted to simulate the ingesting of Martian dust on a small scroll pump, similar to the one used on the MOXIE payload, during its pumping operation. The inlet of the pump was connected to a large volume closed-loop pipe system, known as the Mars Atmospheric Flow Loop, containing pure CO2 gas at a Martian pressure of 7 Torr. A length of stainless steel tubing was extended from the inlet port of scroll pump, which was mounted outside the flow loop, to the inside volume of the flow loop using a feed-through compression fitting. A steady low-speed flow was generated inside the flow loop to continuously disperse and transport the dust toward the inlet tubing. JSC-Mars 1 Martian simulant was used to challenge the pump. The pump performance parameters such as flow rate, pump speed, pressures and temperature were monitored during these tests. Samples of the dust entering the pump inlet were taken prior to exposure tests, using an inline filter element to determine the rate of dust ingestion into the internal components of the pump. After two tests with exposure times of the order of 60 minutes, the data indicated that small changes in pump performance took place under high rates of dust exposure.

scroll pump↗

Scroll Pump Dust Tolerance Test for Martian Atmospheric Acquisition

The ability to generate oxygen on the Martian surface will be essential to establishing a human presence on Mars. Flow generating devices such as pumps, compressors, and blowers will be crucial components in Martian atmospheric acquisition and processing systems that need to work reliably during the mission duration. A concern with the reliability of the system is its ability to continue to perform nominally when Martian dust, if it bypasses the inlet filter, enters into the system. A series of tests were conducted to simulate the ingestion of Martian dust on a small scroll pump, similar to the one used on the MOXIE payload. The inlet of the pump was connected to a large volume closed-loop pipe system, known as the Mars Atmospheric Flow Loop, containing pure CO2 gas at a Martian pressure of 7 Torr. A length of stainless steel tubing was extended from the inlet port of scroll pump, which was mounted outside the flow loop, to the inside volume of the flow loop using a feed-through compression fitting. A steady low-speed flow was generated inside the flow loop to continuously disperse and transport the dust toward the inlet tubing. JSC-Mars 1 Martian simulant was used to challenge the pump. Pump performance parameters such as flow rate, pump speed, pressure and temperature were monitored during these tests. Samples of the dust entering the pump inlet were taken prior to the exposure tests, using an inline filter element to determine the rate of dust ingestion into the internal components of the pump. After two tests with exposure times of one hour, the data indicated that small changes in pump performance took place under high rates of dust exposure.

Martian Atmospheric↗

Laboratory testing of a supercritical helium pump for a magnetic refrigerator

A supercritical helium testing system for a magnetic refrigerator has been built. Details of the supercritical helium pump, the test system, and the test instrumentation are given. Actual pump tests were not run during this ASEE term because of delivery problems associated with the required pump flow meter. Consequently, efforts were directed on preliminary design of the magnetic refrigeration system for the pump. The first concern with the magnetic refrigerator design was determining how to effectively make use of the pump. A method to incorporate the supercritical helium pump into a magnetic refrigerator was determined by using a computer model. An illustrated example of this procedure is given to provide a tool for sizing the magnetic refrigerator system as a function of the pump size. The function of the computer model and its operation are also outlined and discussed.

Wang, Pao-Lien↗

Flight Test Results for the HST Orbital Systems Test (HOST) Capillary Pump Loop Cooling System

The Near Infrared Camera and Multi Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope (MST) in February 1997. Shortly thereafter, the instrument experienced a thermal short in its solid nitrogen dewar system which will significantly shorten the instrument's useful life. A reverse Brayton cycle mechanical refrigerator will be installed during the Third Servicing Mission (SM3) to provide cooling for the instrument, and thereby extend its operations. A Capillary Pump Loop (CPL) and radiator system was designed, built and tested to remove up to 500 watts of heat from the mechanical cryocooler and its associated electronics. The HST Orbital Systems Test (HOST) platform was flown on the Space Shuttle Discovery (STS-95) as a flight demonstration of the cryocooler system, CPL control electronics, and the CPL/Radiator. This paper will present the flight test results and thermal performance of the CPL system in detail.

Buchko, M.↗

Ion pump and leak life test

The fabrication and long term testing of a flight type ion pump and sintered inlet leak are described. These tests were conducted over a period of one year at an ion pump pressure of approximately 0.000001 torr. These long term tests were conducted to investigate aging of ion pumps and leaks under continuous use. Pumping speed and leak conductance, as well as other parameters, were measured on a weekly basis with ion pump start tests conducted on a monthly basis.

Ierokomos, N.↗

Evaluation of tantalum-alloy-clad uranium mononitride fuel specimens from 7500-hour, 1040 C pumped-lithium-loop test

Simulated nuclear fuel element specimens, consisting of uranium mononitride (UN) fuel cylinders clad with tungsten-lined T-111, were exposed for up to 7500 hr at 1040 C (1900 F) in a pumped-lithium loop. The lithium flow velocity was 1.5 m/sec (5 ft/sec) in the specimen test section. No evidence of any compatibility problems between the specimens and the flowing lithium was found based on appearance, weight change, chemistry, and metallography. Direct exposure of the UN to the lithium through a simulated cladding crack resulted in some erosion of the UN in the area of the defect. The T-111 cladding was ductile after lithium exposure, but it was sensitive to hydrogen embrittlement during post-test handling.

Watson, G. K.↗

Fuel cell technology program

A fuel cell technology program was established to advance the state-of-the-art of hydrogen-oxygen fuel cells using low temperature, potassium hydroxide electrolyte technology as the base. Program tasks are described consisting of baseline cell design and stack testing, hydrogen pump design and testing, and DM-2 powerplant testing and technology extension efforts. A baseline cell configuration capable of a minimum of 2000 hours of life was defined. A 6-cell prototype stack, incorporating most of the scheme cell features, was tested for a total of 10,497 hours. A 6-cell stack incorporating all of the design features was tested. The DM-2 powerplant with a 34 cell stack, an accessory section packaged in the basic configuration anticipated for the space shuttle powerplant and a powerplant control unit, was defined, assembled, and tested. Cells were used in the stack and a drag-type hydrogen pump was installed in the accessory section. A test program was established, in conjunction with NASA/JSC, based on space shuttle orbiter mission. A 2000-hour minimum endurance test and a 5000-hour goal were set and the test started on August 8, 1972. The 2000-hour milestone was completed on November 3, 1972. On 13 March 1973, at the end of the thirty-first simulated seven-day mission and 5072 load hours, the test was concluded, all goals having been met. At this time, the DM-2 was in excellent condition and capable of additional endurance.

Source record↗

Fabrication and test of a space power boiler feed electromagnetic pump. 3: Endurance and final performance tests

A three-phase helical induction electromagnetic pump designed for the boiler feed pump of a potassium Rankine cycle space power system was developed and built. It was mounted in a liquid metal test loop and successfully tested over a range of potassium temperatures from 900 to 1400 F, flow rates from 0.75 to 4.85 lb/sec, developed pressures up to 340 psi, net positive suction head from 1 to 22 psi, and NaK coolant temperatures from 800 to 950 F. Maximum efficiency at design point conditions of 3.25 lb/sec flow rate, 240 psi developed head, 1000 F potassium inlet temperature, and 800 F NaK coolant inlet temperature was 16.3 percent. After the performance tests the pump was operated without any difficulty at design point for 10,000 hours, and then a limited number of repeat performance tests were made. There was no appreciable change in pump performance after 10,000 hours of operation. A supplementary series of tests using the quasi-square wave power output of a dc to three-phase ac inverter showed that the pump would operate without difficulty at a frequency as low as 25 Hz, with little loss in efficiency.

Powell, A. H.↗

Reactor Simulator Integration and Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator (RxSim) test loop was designed and built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing were to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V because the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This Technical Memorandum summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained, which was lower than the predicted 750 K but 156 K higher than the cold temperature, indicating the design provided some heat regeneration. The annular linear induction pump tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

Schoenfield, M. P.↗

Characterization of a centrifugal pump in He II

As part of an effort to determine the feasibility of helium transfer in space, a centrifugal pump was tested in He II at a variety of flow rates, pump speeds, and fluid temperatures. The pump, which has a straight bladed impeller 6.86 cm in diameter, generated a maximum pressure rise of 15 kPa and a maximum flow rate of 22 g/s for the conditions of the test. Pump performance seems to be independent of fluid temperature and is in good agreement with the values predicted by the manufacturer. Over the range of flow coefficients, the measured maximum efficiency is around 50 percent. Cavitation is observed in the pump and is thought to be highly dependent on the local heating of the helium in the pump. Preliminary measurements of the noise spectra of the pump suggest a possible mechanism to predict the onset of cavitation.

Weisend, J. G., II↗

Design and testing of a tandem row pump inducer

The design and testing of a tandem row pump inducer having a supercavitating first stage with a 0.60 hub ratio is presented. The second stage tested was a helical impeller with a 0.70 hub ratio. A cubic arc transition was utilized to accomplish the hub change. The first stage had two blades and the free-vortex design approach was empirically modified based on previous experience. The recommended second stage design having four blades and using cambered blade section is presented but the model was not built or tested. The more simple helix was built instead to reduce cost. Data taken included head generation, cavitation observations and unsteady head fluctuations over the 0-100Hz range.

Etter, R. J.↗