Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

W T Wallace↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

William T Wallace↗

The Dawn of Geostationary Air Quality Monitoring: Case Studies from Seoul and Los Angeles

With the near-future launch of geostationary pollution monitoring satellite instruments over North America, East Asia, and Europe, the air quality community is preparing for an integrated global atmospheric composition observing system at unprecedented spatial and temporal resolutions. One of the ways that NASA has supported this community preparation is through demonstration of future space-borne capabilities using the Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) airborne instrument. This paper integrates repeated high-resolution maps from GeoTASO, ground-based Pandora spectrometers, and low Earth orbit measurements from the Ozone Mapping and Profiler Suite (OMPS), for case studies over two metropolitan areas: Seoul, South Korea on June 9, 2016 and Los Angeles, California on June 27, 2017. This dataset provides a unique opportunity to illustrate how geostationary air quality monitoring platforms and ground-based remote sensing networks will close the current spatiotemporal observation gap. GeoTASO observes large differences in diurnal behavior between these urban areas, with NO2 accumulating within the Seoul Metropolitan Area through the day but NO2 peaking in the morning and decreasing throughout the afternoon in the Los Angeles Basin. In both areas, the earliest morning maps exhibit spatial patterns similar to emission source areas (e.g., urbanized valleys, roadways, major airports). These spatial patterns change later in the day due to boundary layer dynamics, horizontal transport, and chemistry. The nominal resolution of GeoTASO is finer than will be obtained from geostationary platforms, but when NO2 data over Los Angeles are up-scaled to the expected resolution of TEMPO, spatial features discussed are conserved. Pandora instruments installed in both metropolitan areas capture the diurnal patterns observed by GeoTASO, continuously and over longer time periods, and will play a critical role in validation of the next generation of satellite measurement. These case studies demonstrate that different regions can have diverse diurnal patterns and that day-to-day variability due to meteorology or anthropogenic patterns such as weekday/weekend variations in emissions is large. Low Earth orbit measurements, despite their inability to capture the diurnal patterns at fine spatial resolution, will be essential for intercalibrating the geostationary radiances and cross-validating the geostationary retrievals in an integrated global observing system.

Geostationary↗

Atmosphere and water quality monitoring on Space Station Freedom

In Space Station Freedom air and water will be supplied in closed loop systems. The monitoring of air and water qualities will ensure the crew health for the long mission duration. The Atmosphere Composition Monitor consists of the following major instruments: (1) a single focusing mass spectrometer to monitor major air constituents and control the oxygen/nitrogen addition for the Space Station; (2) a gas chromatograph/mass spectrometer to detect trace contaminants; (3) a non-dispersive infrared spectrometer to determine carbon monoxide concentration; and (4) a laser particle counter for measuring particulates in the air. An overview of the design and development concepts for the air and water quality monitors is presented.

Niu, William↗

Air Quality Monitoring Case Study Using Mobile Low-cost Sensors Mounted on Trash-Trucks: Methods Development and Lessons Learned

Air quality monitoring (AQM) is crucial for cities to develop management plans supporting population health. However, there is a dearth of measurements due to the high cost of standard reference instruments. Mobile AQM using low-cost sensors deployed on routine fleets of vehicles can enable the continuous detection of fine-scale pollutant variations in cities at a lower cost. New methods need to be developed to interpret these measurements. This paper presents three such methods. First, we propose a technique to identify aerosol hotspots. Second, we employ techniques published previously to assess the generalizable map of fine and coarse particle number concentrations, to understand qualitatively the contribution of local and regional sources across the region sampled. By using the raw number concentration of differently sized particles from the Optical Particle Counters (OPCs) instead of the noisier mass concentrations, we obtain more robust results. Third, in order to evaluate source signatures in cities, we propose another technique, in which we cluster the entire range of aerosol size-distribution measurements acquired. The properties of each cluster provide insight into the aerosol source characteristics in the sampling environment. We test these methods using a dataset we collected by mounting OPCs on two trash-trucks in Cambridge, Massachusetts.

Drive-by sensing↗

Air Quality Monitoring Case Study Using Mobile Low-cost Sensors mounted on Trash-Trucks: Methods Development and Lessons Learned

Air quality monitoring (AQM) is crucial for cities to develop management plans supporting population health. However, there is a dearth of measurements due to the high cost of standard reference instruments. Mobile AQM using low-cost sensors deployed on routine fleets of vehicles can enable the continuous detection of fine-scale pollutant variations in cities at a lower cost. New methods need to be developed to interpret these measurements. This paper presents three such methods. First, we propose a technique to identify aerosol hotspots. Second, we employ techniques published previously to assess the generalizable map of fine and coarse particle number concentrations, to understand qualitatively the contribution of local and regional sources across the region sampled. By using the raw number concentration of differently sized particles from the Optical Particle Counters (OPCs) instead of the noisier mass concentrations, we obtain more robust results. Third, in order to evaluate source signatures in cities, we propose another technique, in which we cluster the entire range of aerosol size-distribution measurements acquired. The properties of each cluster provide insight into the aerosol source characteristics in the sampling environment. We test these methods using a dataset we collected by mounting OPCs on two trash-trucks in Cambridge, Massachusetts.

Drive-by sensing↗

Great Salt Lake Health and Air Quality: Monitoring Lakebed Exposure and its Impact on Air Quality and Environmental Hazards in the Great Salt Lake Watershed

Water flow into the Great Salt Lake has declined rapidly over the last forty years due to human withdrawals and climate change. As a result of declining lake levels, over 50% of the lakebed is now exposed. Dust storms may grow in frequency and intensity across Northern Utah as lakebed dust becomes airborne under specific meteorological conditions. In our research project, we utilized satellite imagery from Terra and Aqua, Sentinel-5P, CALIPSO, Landsat 5 TM, Landsat 7 ETM+, Landsat 8 OLI-2, Suomi NPP, ground sensor environmental data, and demographic data to understand the relationship between lake desiccation and dust, and the impact of pollution upon the communities surrounding the Great Salt Lake. By plotting changes in Lake Surface Area against Aerosol Optical Depth (AOD) over our study period (2010-2022), we found an inverse relationship (R2=0.3423) between lake surface area and dust levels within our study area. We conducted a Vertical Feature Mask (VFM) and Extinction Coefficient Plot, from which we identified that during dust events, the aerosol type is mainly polluted dust and the aerosol height is 200 meters from the surface. Lastly, we created bivariate choropleth maps, which demonstrate which census tracts within our study area are most vulnerable to AOD (a proxy for PM2.5 from dust), NO2 and HCHO (precursors to ozone). In summary, our findings revealed that declining lake levels are associated with an increase in intensity of dust events, and these dust events will particularly impact residents of Tooele County and the west side of Salt Lake City. Project resources support partner needs by informing targeted air monitoring efforts, lakebed management practices, and advocacy efforts for GSL stewardship.

Terminal Saline Lake↗

Great Salt Lake Health & Air Quality: Monitoring Lakebed Exposure and its Impact on Air Quality and Environmental Hazards in the Great Salt Lake Watershed

The Great Salt Lake (GSL) is a terminal saline lake located in northern Utah, USA. Water inflow has declined rapidly over the last forty years due to human withdrawals and climate change. Lake levels have been lowered which has exposed over 50% of the lakebed to erosion. There is a public health risk tied to the subsequent increased frequency and intensity of regional dust storms caused by airborne lakebed dust under specific meteorological conditions.

Piper Christian↗

Great Salt Lake Health & Air Quality: Monitoring Lakebed Exposure and its Impact on Air Quality and Environmental Hazards in the Great Salt Lake Watershed

The Great Salt Lake (GSL) is a terminal saline lake located in northern Utah, USA. Water inflow has declined rapidly over the last forty years due to human withdrawals and climate change. Lake levels have been lowered which has exposed over 50% of the lakebed to erosion. There is a public health risk tied to the subsequent increased frequency and intensity of regional dust storms caused by airborne lakebed dust under specific meteorological conditions.

Piper Christian↗

A chemical sensor and biosensor based totally automated water quality monitor for extended space flight: Step 1

The result of a literature search to consider what technologies should be represented in a totally automated water quality monitor for extended space flight is presented. It is the result of the first summer in a three year JOVE project. The next step will be to build a test platform at the Authors' school, St. John Fisher College. This will involve undergraduates in NASA related research. The test flow injection analysis system will be used to test the detection limit of sensors and the performance of sensors in groups. Sensor companies and research groups will be encouraged to produce sensors which are not currently available and are needed for this project.

Smith, Robert S.↗

Gage monitors quality of cross-wire resistance welds

Gage nondestructively monitors the quality of cross-wire resistance welds during the welding operation. The gage gives a dial indication of the relative embedment of the cross wires during the actual welding operation. A direct relationship exists between the depth of embedment and both weld strength and consistency.

Etzel, J.↗

Application of Advanced Earth Observations and Model Simulations to Improve Air Quality Monitoring in the Hindu-Kush-Himalayan Region

Air pollution is a serious environmental health concern in the Hindu Kush Himalayan (HKH) region of south-central Asia, as rapid industrialization and population growth have led to increased anthropogenic emissions from transportation, residential, industrial, energy, and biomass burning sources. Natural emissions from dust and forest fires are additional sources of air pollutants that can exacerbate air quality in the region. The combination of the complex pollutant mixtures and atmospherically stable weather conditions during the winter monsoon can visibility reductions and hazardous air quality from persistent haze episodes. The Kathmandu Valley is especially vulnerable to extreme haze issues due to the surrounding mountains that restrict air movement and retains pollutants in the atmosphere. This study uses state-of-the-art satellite observations and modeling capabilities in conjunction with ground-based networks to provide a comprehensive data toolkit for advancing air quality monitoring and forecasting decisions in the HKH region. The toolkit includes new generation satellite observations from the TROPOspheric Monitoring Instrument (TROPOMI), Geostationary Environment Monitoring Spectrometer (GEMS), and Advanced Meteorological Imager, which provide high spatiotemporal information on NO2, HCHO, SO2, O3, and aerosol optical depth (AOD). Particulate matter with diameters less than 2.5 micrometers (PM2.5) are derived from the satellite-retrieved AOD using ground-based observations and forecast model data. The satellite observations are also used to initialize and constrain forecast model systems designed for the HKH region. This talk will highlight the performance of the air quality toolkit for enhancing decision-making processes during exceptional air quality events in the region. Note: Presentation includes additional attachment of full presentation with sound and animation (best when viewed as slide show) with runtime of 15 min 32 secs

Aaron Naeger↗

On-Orbit MTF Measurement and Product Quality Monitoring for Commercial Remote Sensing Systems

Initialization and opportunistic targets are chosen that represent the MTF on the spatial domain. Ideal targets have simple mathematical relationships. Determine the MTF of an on-orbit satellite using in-scene targets: Slant-Edge, Line Source, point Source, and Radial Target. Attempt to facilitate the MTF calculation by automatically locating targets of opportunity. Incorporate MTF results into a product quality monitoring architecture.

Person, Steven↗

Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.

Hazen-Bosveld, April↗

Performance Evaluation of the Operational Air Quality Monitor for Water Testing Aboard the International Space Station

Real-time environmental monitoring on ISS is necessary to provide data in a timely fashion and to help ensure astronaut health. Current real-time water TOC monitoring provides high-quality trending information, but compound-specific data is needed. The combination of ETV with the AQM showed that compounds of interest could be liberated from water and analyzed in the same manner as air sampling. Calibration of the AQM using water samples allowed for the quantitative analysis of ISS archival samples. Some calibration issues remain, but the excellent accuracy of DMSD indicates that ETV holds promise for as a sample introduction method for water analysis in spaceflight.

Wallace, William T.↗