Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Quantitative Confocal Raman Microscopy Study of Ion-Interaction Retention at Reversed-Phase Chromatographic Interfaces

Ion-interaction chromatography utilizes the addition of amphiphilic (surfactant) molecules to the mobile phase solution in order to bring about the retention and separation of hydrophilic ionic analytes on reversed-phase liquid chromatographic stationary phases. The mechanism by which retention and separation in ion-interaction chromatography is accomplished remains unclear, although two primary mechanisms of this phenomenon have been proposed: pre-adsorption of the hydrophobic counter ions to the hydrophobic stationary phase followed by interaction with the ionic analyte, or ion pairing in solution with subsequent sorption of the paired species to the hydrophobic surface. There is evidence that both mechanisms contribute to ionic retention and separations. In this work, ion interactions at a C18 stationary phase interface are investigated by confocal Raman microscopy of individual stationary-phase particles, which is capable of quantifying surface concentrations of surfactants and model solutes. Raman spectra taken within the interior of the particle indicate that pre-adsorption of the hydrophobic surfactant cetylpyridinium to the stationary phase interface is sensitive to ionic strength and concentration of organic modifier in the mobile phase. Furthermore, it was also determined that the presence of low concentrations of a model, ionic solute, nitrobenzenesulfonate, leads to greater adsorption of cetylpyridinium ion at the hydrophobic interface. As the concentration of nitrobenzenesulfonate is increased, the 1:1 increase in the cetylpyridinium-ion interfacial concentration provides evidence of ion pairs forming at the stationary phase surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative transmission electron microscopy analysis of multi-variant grains in present L1{sub 0}-FePt based heat assisted magnetic recording media

We present a study on atomic ordering within individual grains in granular L1{sub 0}-FePt thin films using transmission electron microscopy techniques. The film, used as a medium for heat assisted magnetic recording, consists of a single layer of FePt grains separated by non-magnetic grain boundaries and is grown on an MgO underlayer. Using convergent-beam techniques, diffraction patterns of individual grains are obtained for a large number of crystallites. The study found that although the majority of grains are ordered in the perpendicular direction, more than 15% of them are multi-variant, or of in-plane c-axis orientation, or disordered fcc. It was also found that these multi-variant and in-plane grains have always grown across MgO grain boundaries separating two or more MgO grains of the underlayer. The in-plane ordered portion within a multi-variant L1{sub 0}-FePt grain always lacks atomic coherence with the MgO directly underneath it, whereas, the perpendicularly ordered portion is always coherent with the underlying MgO grain. Since the existence of multi-variant and in-plane ordered grains are severely detrimental to high density data storage capability, the understanding of their formation mechanism obtained here should make a significant impact on the future development of hard disk drive technology.

36 MATERIALS SCIENCE↗

Quantitative magnetic imaging at the nanometer scale by ballistic electron magnetic microscopy

We demonstrate quantitative ballistic electron magnetic microscopy (BEMM) imaging of simple model Fe(001) nanostructures. We use in situ nanostencil shadow mask resistless patterning combined with molecular beam epitaxy deposition to prepare under ultra-high vacuum conditions nanostructured epitaxial Fe/Au/Fe/GaAs(001) spin-valves. In this epitaxial system, the magnetization of the bottom Fe/GaAs(001) electrode is parallel to the [110] direction, defining accurately the analysis direction for the BEMM experiments. The large hot-electron magnetoresistance of the Fe/Au/Fe/GaAs(001) epitaxial spin-valve allows us to image various stable magnetic configurations on the as-grown Fe(001) microstructures with a high sensitivity, even for small misalignments of both magnetic electrodes. The angular dependence of the hot-electron magnetocurrent is used to convert magnetization maps calculated by micromagnetic simulations into simulated BEMM images. The calculated BEMM images and magnetization rotation profiles show quantitative agreement with experiments and allow us to investigate the magnetic phase diagram of these model Fe(001) microstructures. Finally, magnetic domain reversals are observed under high current density pulses. This opens the way for further BEMM investigations of current-induced magnetization dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compositional analysis of GaAs/AlGaAs heterostructures using quantitative scanning transmission electron microscopy

We demonstrate a method for compositional mapping of Al{sub x}Ga{sub 1–x}As heterostructures with high accuracy and unit cell spatial resolution using quantitative high angle annular dark field scanning transmission electron microscopy. The method is low dose relative to spectroscopic methods and insensitive to the effective source size and higher order lens aberrations. We apply the method to study the spatial variation in Al concentration in cross-sectioned GaAs/AlGaAs core-shell nanowires and quantify the concentration in the Al-rich radial band and the AlGaAs shell segments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative measurement of in-plane cantilever torsion for calibrating lateral piezoresponse force microscopy.

A simple quantitative measurement procedure of in-plane cantilever torsion for calibrating lateral piezoresponse force microscopy is presented. This technique enables one to determine the corresponding lateral inverse optical lever sensitivity (LIOLS) of the cantilever on the given sample. Piezoelectric coefficient, d{sub 31} of BaTiO{sub 3} single crystal (-81.62 {+-} 40.22 pm/V) which was calculated using the estimated LIOLS was in good agreement with the reported value in literature.

47 OTHER INSTRUMENTATION↗

Sub-0.1 nm-resolution quantitative scanning transmission electron microscopy without adjustable parameters

Atomic-resolution imaging in the scanning transmission electron microscope (STEM) constitutes a powerful tool for nanostructure characterization. Here, we demonstrate the quantitative interpretation of atomic-resolution high-angle annular dark-field (ADF) STEM images using an approach that does not rely on adjustable parameters. We measure independently the instrumental parameters that affect sub-0.1 nm-resolution ADF images, quantify their individual and collective contributions to the image intensity, and show that knowledge of these parameters enables a quantitative interpretation of the absolute intensity and contrast across all accessible spatial frequencies. The analysis also provides a method for the in-situ measurement of the STEM's effective source distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Scanning Transmission Electron Microscopy for Materials Science: Imaging, Diffraction, Spectroscopy, and Tomography

Scanning transmission electron microscopy (STEM) is one of the most powerful characterization tools in materials science research. Due to instrumentation developments such as highly coherent electron sources, aberration correctors, and direct electron detectors, STEM experiments can examine the structure and properties of materials at length scales of functional devices and materials down to single atoms. STEM encompasses a wide array of flexible operating modes, including imaging, diffraction, spectroscopy, and 3D tomography experiments. This review outlines many common STEM experimental methods with a focus on quantitative data analysis and simulation methods, especially those enabled by open source software. The hope is to introduce both classic and new experimental methods to materials scientists and summarize recent progress in STEM characterization. The review also discusses the strengths and weaknesses of the various STEM methodologies and briefly considers promising future directions for quantitative STEM research.

36 MATERIALS SCIENCE↗

Quantitative Scanning Laue Diffraction Microscopy: Application to the Study of 3D Printed Nickel-Based Superalloys

Progress in computing speed and algorithm efficiency together with advances in area detector and X-ray optics technologies have transformed the technique of synchrotron radiation-based scanning Laue X-ray microdiffraction. It has now evolved into a near real-time quantitative imaging tool for material structure and deformation at the micrometer and nanometer scales. We will review the achievements of this technique at the Advanced Light Source (Berkeley, CA, USA), and demonstrate its application in the thorough microstructural investigations of laser-assisted 3D printed nickel-based superalloys.

36 MATERIALS SCIENCE↗

Quantitative Electromechanical Atomic Force Microscopy

The ability to probe a materials electromechanical functionality on the nanoscale is significant to applications from energy storage and computing to biology and medicine. Voltage modulated atomic force microscopy (VM-AFM) has become a mainstay characterization tool for investigating these materials due to its ability to locally probe electromechanically responsive materials with spatial resolution from microns to nanometers. However, with the wide popularity of VM-AFM techniques such as piezoresponse force microscopy (PFM) and electrochemical strain microscopy (ESM) there has been a rise in reports of nanoscale electromechanical functionality, including hysteresis, in materials that should be incapable of exhibiting piezo- or ferroelectricity. Explanations for the origins of unexpected nanoscale phenomena have included new material properties, surface-mediated polarization changes and/or spatially resolved behavior that is not present in bulk measurements. At the same time, it is well known that VM-AFM measurements are vulnerable to numerous forms of crosstalk and, despite efforts within the AFM community, a global approach for eliminating this has remained elusive. Here, we develop a method for easily demonstrating the presence of hysteretic ( i.e. “false ferroelectric”) long-range interactions between the sample and cantilever body. This approach should be easy to implement in any VM-AFM measurement. We then go on to demonstrate fully quantitative and repeatable nanoelectromechanical characterization using an interferometer. These quantitative measurements are critical for a wide range of devices including mems actuators and sensors, memristor, energy storage and memory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Some strategies for quantitative scanning Auger electron microscopy

The general applicability of power law forms of the background in electron spectra is pointed out and exploited for background removal from under Auger peaks. This form of B(E) is found to be extremely sensitive to instrumental alignment and to fault-free construction - an observation which can be used to set up analyser configurations in an accurate way. Also, differences between N(E) and B(E) can be used to derive a spectrometer transmission function T(E). The questions of information density in an energy-analysing spatially-resolving instrument are addressed after reliable instrumental characterization has been established. Strategies involving ratio histograms, showing the population distribution of the ratio of a pair of Auger peak heights, composition scatter diagrams and windowed imaging are discussed and illustrated.

Browning, R.↗