Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Thematic Mapper Image Processing System (TIPS) Processing Status

Radiometric and geometric correction performance is considered. A one quantum level requirement was met in all spectral bands with an occasional band 7 exception. Initial post launch calibration was accomplished. An absolute radiometric calibration is in progress including an investigation of low impact solution to scan striping. Initial and three downstream updates as well as coordination with LANDSAT D' instrument calibration are planned. Methods and problems in measuring geometric correction performance are examined with an emphasis on temporal registration, geodetic registrtion, and the modeling error budget. Planned efforts include eliminating band 2, band 5 chips; continued performance monitoring; calibration of profile, misalignment angles, and filer parameters; studying the need for seasonal geodetic control points; and improvement of the subpixel correlation technique.

Brooks, J.↗

Self-imaging of transparent objects and structures in focusing of spatially phase-modulated laser radiation into a weakly absorbing medium

Self-imaging of transparent objects and structures in focusing of a spatially phase-modulated laser beam into an extended weakly absorbing medium is described. The laser power level that is necessary for effective imaging corresponds to the illuminating beam power when thermal self-defocusing starts evolving in the medium. The effect can be described in terms of the ideology of Zernike's classical phase-contrast method. Edge enhancement in visualised images of transparent objects is experimentally demonstrated. Self-imaging of a microscopic object in the form of transparent letters and long-lived refractive-index fluctuations in liquid glycerol is shown. Due to the adaptivity of the process under consideration, unlike the classical case, self-imaging occurs also in the situations where a beam is displaced (undergoes random walk) as a whole in the Fourier plane, for example, in the presence of thermal flows. (image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum machine learning with differential privacy

Abstract Quantum machine learning (QML) can complement the growing trend of using learned models for a myriad of classification tasks, from image recognition to natural speech processing. There exists the potential for a quantum advantage due to the intractability of quantum operations on a classical computer. Many datasets used in machine learning are crowd sourced or contain some private information, but to the best of our knowledge, no current QML models are equipped with privacy-preserving features. This raises concerns as it is paramount that models do not expose sensitive information. Thus, privacy-preserving algorithms need to be implemented with QML. One solution is to make the machine learning algorithm differentially private, meaning the effect of a single data point on the training dataset is minimized. Differentially private machine learning models have been investigated, but differential privacy has not been thoroughly studied in the context of QML. In this study, we develop a hybrid quantum-classical model that is trained to preserve privacy using differentially private optimization algorithm. This marks the first proof-of-principle demonstration of privacy-preserving QML. The experiments demonstrate that differentially private QML can protect user-sensitive information without signficiantly diminishing model accuracy. Although the quantum model is simulated and tested on a classical computer, it demonstrates potential to be efficiently implemented on near-term quantum devices [noisy intermediate-scale quantum (NISQ)]. The approach’s success is illustrated via the classification of spatially classed two-dimensional datasets and a binary MNIST classification. This implementation of privacy-preserving QML will ensure confidentiality and accurate learning on NISQ technology.

97 MATHEMATICS AND COMPUTING↗

Indirect precise angular control using four-wave mixing

Here, we show indirect precise angular control using a four-wave mixing (FWM) process. This was performed with a superposition of light with orbital angular momentum in an M-Type configuration of a hot {sup 85}Rb atomic ensemble. A gear-shaped interference pattern is observed at FWM light with a donut-shaped input signal. The gear could be rotated and is controlled through the change of the polarization of the pump laser. Our experimental results that are based on nonlinear coherent interactions have applications in image processing and precise angular control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization

Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems. Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9. Results: The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated. Conclusions: As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of different computed radiography systems: Physical characterization and contrast detail analysis

Purpose: In this study, five different units based on three different technologies--traditional computed radiography (CR) units with granular phosphor and single-side reading, granular phosphor and dual-side reading, and columnar phosphor and line-scanning reading--are compared in terms of physical characterization and contrast detail analysis. Methods: The physical characterization of the five systems was obtained with the standard beam condition RQA5. Three of the units have been developed by FUJIFILM (FCR ST-VI, FCR ST-BD, and FCR Velocity U), one by Kodak (Direct View CR 975), and one by Agfa (DX-S). The quantitative comparison is based on the calculation of the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Noise investigation was also achieved by using a relative standard deviation analysis. Psychophysical characterization is assessed by performing a contrast detail analysis with an automatic reading of CDRAD images. Results: The most advanced units based on columnar phosphors provide MTF values in line or better than those from conventional CR systems. The greater thickness of the columnar phosphor improves the efficiency, allowing for enhanced noise properties. In fact, NPS values for standard CR systems are remarkably higher for all the investigated exposures and especially for frequencies up to 3.5 lp/mm. As a consequence, DQE values for the three units based on columnar phosphors and line-scanning reading, or granular phosphor and dual-side reading, are neatly better than those from conventional CR systems. Actually, DQE values of about 40% are easily achievable for all the investigated exposures. Conclusions: This study suggests that systems based on the dual-side reading or line-scanning reading with columnar phosphors provide a remarkable improvement when compared to conventional CR units and yield results in line with those obtained from most digital detectors for radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics

Purpose: The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 {mu}m pixel pitch and 300 {mu}m thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 {mu}m pixel pitch and 600 {mu}m thick CsI phosphor). The linear system metrics such as modulation transfer function (MTF), noise power spectrum, and detection quantum efficiency (DQE) are commonly used to gauge the intrinsic detector performance in the detector plane. However, these linear system metrics do not provide information about the image receptor performance in a real system since they do not include the effects of other parameters such as focal spot distribution, scatter radiation, and geometric unsharpness, which may compromise detector performance characteristics. Use of generalized linear system metrics [generalized modulation transfer function (GMTF), generalized normalized noise power spectrum (GNNPS), and generalized detection quantum efficiency (GDQE)] that include these effects gives a more meaningful, complete, and appropriate evaluation of detector performance as part of the imaging system. Methods: A uniform head equivalent phantom was used to simulate realistic clinical parameters and x-ray spectra. The detector MTFs were measured using the slanted edge method and the focal spot MTFs were measured using a pinhole assembly. The scatter MTF was simulated and the scatter fraction was measured for a head-equivalent phantom. The generalized system metrics were calculated for different combinations of three choices of focal spots and three different magnifications with two different air-gaps. The performance of the MAF was also illustrated using stent images obtained with different focal spots under similar conditions. Results: Results for the generalized metrics provide a quantitative description of the performance of the imaging system for both detectors. This generalized analysis demonstrated that both detectors have similar imaging capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. Conclusions: This generalized performance analysis demonstrates the significance of focal spot size, magnification, and scatter on the system performance metrics (GMTF, GNNPS, and GDQE). Although the ideal detector performance characteristics of the MAF are not fully realized due to these other system factors, it still retains an advantage in DQE at high spatial frequencies over the FPD. Similar studies based on the generalized linear system metrics can serve as an efficient tool to evaluate total system capabilities under different realistic conditions to enable optimal design for specific imaging tasks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plate-specific gain map correction for the improvement of detective quantum efficiency in computed radiography

Purpose: The purpose of this work is to improve the noise power spectrum (NPS), and thus the detective quantum efficiency (DQE), of computed radiography (CR) images by correcting for spatial gain variations specific to individual imaging plates. CR devices have not traditionally employed gain-map corrections, unlike the case with flat-panel detectors, because of the multiplicity of plates used with each reader. The lack of gain-map correction has limited the DQE(f) at higher exposures with CR. This current work describes a feasible solution to generating plate-specific gain maps. Methods: Ten high-exposure open field images were taken with an RQA5 spectrum, using a sixth generation CR plate suspended in air without a cassette. Image values were converted to exposure, the plates registered using fiducial dots on the plate, the ten images averaged, and then high-pass filtered to remove low frequency contributions from field inhomogeneity. A gain-map was then produced by converting all pixel values in the average into fractions with mean of one. The resultant gain-map of the plate was used to normalize subsequent single images to correct for spatial gain fluctuation. To validate performance, the normalized NPS (NNPS) for all images was calculated both with and without the gain-map correction. Variations in the quality of correction due to exposure levels, beam voltage/spectrum, CR reader used, and registration were investigated. Results: The NNPS with plate-specific gain-map correction showed improvement over the noncorrected case over the range of frequencies from 0.15 to 2.5 mm{sup -1}. At high exposure (40 mR), NNPS was 50%-90% better with gain-map correction than without. A small further improvement in NNPS was seen from carefully registering the gain-map with subsequent images using small fiducial dots, because of slight misregistration during scanning. Further improvement was seen in the NNPS from scaling the gain map about the mean to account for different beam spectra. Conclusions: This study demonstrates that a simple gain-map can be used to correct for the fixed-pattern noise in a given plate and thus improve the DQE of CR imaging. Such a method could easily be implemented by manufacturers because each plate has a unique bar code and the gain-map for all plates associated with a reader could be stored for future retrieval. These experiments indicated that an improvement in NPS (and hence, DQE) is possible, depending on exposure level, over a wide range of frequencies with this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image mosaicing for automated pipe scanning

Remote visual inspection (RVI) is critical for the inspection of the interior condition of pipelines particularly in the nuclear and oil and gas industries. Conventional RVI equipment produces a video which is analysed online by a trained inspector employing expert knowledge. Due to the potentially disorientating nature of the footage, this is a time intensive and difficult activity. In this paper a new probe for such visual inspections is presented. The device employs a catadioptric lens coupled with feature based structure from motion to create a 3D model of the interior surface of a pipeline. Reliance upon the availability of image features is mitigated through orientation and distance estimates from an inertial measurement unit and encoder respectively. Such a model affords a global view of the data thus permitting a greater appreciation of the nature and extent of defects. Furthermore, the technique estimates the 3D position and orientation of the probe thus providing information to direct remedial action. Results are presented for both synthetic and real pipe sections. The former enables the accuracy of the generated model to be assessed while the latter demonstrates the efficacy of the technique in a practice.

42 ENGINEERING↗

Scintillator detector characterization for laser-driven proton beam imaging

The spatial resolution and imaging characteristics of plastic scintillators are characterized using laser-driven proton beams. Laser-driven proton beams typically have broad energy spectra and are accompanied by relativistic electrons and high-energy photons, both potentially contributing to background noise. Different types and thicknesses of Eljen Technology scintillators are compared to determine their intrinsic point spread function. Point-projection imaging of a mesh is used to compare the imaging resolution of the scintillator to the usual imaging detector, radiochromic film, and is found to be reasonably comparable and sufficient for many experimental applications.

47 OTHER INSTRUMENTATION↗

Reconfigurable unitary transformations of optical beam arrays

Spatial transformations of light are ubiquitous in optics, with examples ranging from simple imaging with a lens to quantum and classical information processing in waveguide meshes. Multi-plane light converter (MPLC) systems have emerged as a platform that promises completely general spatial transformations, i.e., a universal unitary. However, until now, MPLC systems have demonstrated transformations that are far from general, e.g., converting from a Gaussian to Laguerre-Gauss mode. Here, we demonstrate the promise of an MLPC, the ability to impose an arbitrary unitary transformation that can be reconfigured dynamically. Specifically, we consider transformations on superpositions of parallel free-space beams arranged in an array, which is a common information encoding in photonics. We experimentally test the full gamut of unitary transformations for a system of two parallel beams and make a map of their fidelity. We obtain an average transformation fidelity of 0.85 ± 0.03. This high-fidelity suggests that MPLCs are a useful tool for implementing the unitary transformations that comprise quantum and classical information processing.

47 OTHER INSTRUMENTATION↗

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)↗

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

Correlative fluorescence microscopy and liquid STEM of proteins labeled with quantum dots on intact cells.

Liquid scanning transmission electron microscopy (liquid STEM) was used to image individual quantum dots bound to receptors in COS7 cells. The same regions on intact fixed cells were imaged both with fluorescence microscopy and liquid STEM. The obtained spatial resolution on was 3 nm. The resolution was sufficient to discriminate between quantum dots and gold nanoparticles for double labeling applications.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray Parametric Down Conversion at an XFEL

Understanding and harnessing X-ray quantum effects could open new frontiers in imaging and quantum optics. In this study, we measured the process of X-ray Parametric Down Conversion, where a single high-energy X-ray photon splits into two lower-energy photons. Using the SACLA X-ray Free Electron Laser in Japan at 9.83 keV, we found clear evidence that pairs of photons were produced along the energy-angle relationship that conserved both energy and momentum, as predicted for down-conversion, and consistent with quantum entanglement of X-ray photons. By matching specific photon pairs for energy and momentum conservation, we observe a signal rate of 1,250 pairs per hour, confirming that correlated photon pairs can be generated and observed in the absence of explicit time correlations. Our results show that with further refinement, the number of entangled photons produced per laser pulse could increase by an order of magnitude. This paves the way for demonstrating quantum-enhanced X-ray imaging, and confirmation of X-ray photon entanglement.

47 OTHER INSTRUMENTATION↗

Enhanced quantum efficiency of high-purity silicon imaging detectors by ultralow temperature surface modification using Sb doping

A low temperature process for Sb doping of silicon has been developed as a backsurface treatment for high-purity n-type imaging detectors. Molecular beam epitaxy (MBE) is used to achieve very high dopant incorporation in a thin, surface-confined layer. The growth temperature is kept below 450 (deg)C for compatibility with Al-metallized devices. Imaging with MBE-modified 1kx1k charge coupled devices (CCDs) operated in full depletion has been demonstrated. Dark current is comparable to the state-of-the-art process, which requires a high temperature step. Quantum efficiency is improved, especially in the UV, for thin doped layers placed closer to the backsurface. Near 100% internal quantum efficiency has been demonstrated in the ultraviolet for a CCD with a 1.5 nm silicon cap layer.

charged coupled devices (CCDs)↗

Enhanced quantum efficiency of high-purity silicon imaging detectors by ultralow temperature surface modification using Sb doping

A low temperature process for Sb doping of silicon has been developed as a backsurface treatment for high-purity n-type imaging detectors. Molecular beam epitaxy (MBE) is used to achieve very high dopant incorporation in a thin, surface-confined layer. The growth temperature is kept below 450 °C for compatibility with Al-metallized devices. Imaging with MBE-modified 1kx1k charge coupled devices ((CCDs) operated in full depletion has been demonstrated. Dark current is comparable to the state-of-the-art process, which requires a high temperature step. Quantum efficiency is improved, especially in the UV, for thin doped layers placed closer to the backsurface. Near 100% internal quantum efficiency has been demonstrated in the ultraviolet for a CCD with a 1.5 nm silicon cap layer.

Nikzad, Shouleh↗