Comparison of different computed radiography systems: Physical characterization and contrast detail analysis

Purpose: In this study, five different units based on three different technologies--traditional computed radiography (CR) units with granular phosphor and single-side reading, granular phosphor and dual-side reading, and columnar phosphor and line-scanning reading--are compared in terms of physical characterization and contrast detail analysis. Methods: The physical characterization of the five systems was obtained with the standard beam condition RQA5. Three of the units have been developed by FUJIFILM (FCR ST-VI, FCR ST-BD, and FCR Velocity U), one by Kodak (Direct View CR 975), and one by Agfa (DX-S). The quantitative comparison is based on the calculation of the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Noise investigation was also achieved by using a relative standard deviation analysis. Psychophysical characterization is assessed by performing a contrast detail analysis with an automatic reading of CDRAD images. Results: The most advanced units based on columnar phosphors provide MTF values in line or better than those from conventional CR systems. The greater thickness of the columnar phosphor improves the efficiency, allowing for enhanced noise properties. In fact, NPS values for standard CR systems are remarkably higher for all the investigated exposures and especially for frequencies up to 3.5 lp/mm. As a consequence, DQE values for the three units based on columnar phosphors and line-scanning reading, or granular phosphor and dual-side reading, are neatly better than those from conventional CR systems. Actually, DQE values of about 40% are easily achievable for all the investigated exposures. Conclusions: This study suggests that systems based on the dual-side reading or line-scanning reading with columnar phosphors provide a remarkable improvement when compared to conventional CR units and yield results in line with those obtained from most digital detectors for radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics

Purpose: The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 {mu}m pixel pitch and 300 {mu}m thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 {mu}m pixel pitch and 600 {mu}m thick CsI phosphor). The linear system metrics such as modulation transfer function (MTF), noise power spectrum, and detection quantum efficiency (DQE) are commonly used to gauge the intrinsic detector performance in the detector plane. However, these linear system metrics do not provide information about the image receptor performance in a real system since they do not include the effects of other parameters such as focal spot distribution, scatter radiation, and geometric unsharpness, which may compromise detector performance characteristics. Use of generalized linear system metrics [generalized modulation transfer function (GMTF), generalized normalized noise power spectrum (GNNPS), and generalized detection quantum efficiency (GDQE)] that include these effects gives a more meaningful, complete, and appropriate evaluation of detector performance as part of the imaging system. Methods: A uniform head equivalent phantom was used to simulate realistic clinical parameters and x-ray spectra. The detector MTFs were measured using the slanted edge method and the focal spot MTFs were measured using a pinhole assembly. The scatter MTF was simulated and the scatter fraction was measured for a head-equivalent phantom. The generalized system metrics were calculated for different combinations of three choices of focal spots and three different magnifications with two different air-gaps. The performance of the MAF was also illustrated using stent images obtained with different focal spots under similar conditions. Results: Results for the generalized metrics provide a quantitative description of the performance of the imaging system for both detectors. This generalized analysis demonstrated that both detectors have similar imaging capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. Conclusions: This generalized performance analysis demonstrates the significance of focal spot size, magnification, and scatter on the system performance metrics (GMTF, GNNPS, and GDQE). Although the ideal detector performance characteristics of the MAF are not fully realized due to these other system factors, it still retains an advantage in DQE at high spatial frequencies over the FPD. Similar studies based on the generalized linear system metrics can serve as an efficient tool to evaluate total system capabilities under different realistic conditions to enable optimal design for specific imaging tasks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plate-specific gain map correction for the improvement of detective quantum efficiency in computed radiography

Purpose: The purpose of this work is to improve the noise power spectrum (NPS), and thus the detective quantum efficiency (DQE), of computed radiography (CR) images by correcting for spatial gain variations specific to individual imaging plates. CR devices have not traditionally employed gain-map corrections, unlike the case with flat-panel detectors, because of the multiplicity of plates used with each reader. The lack of gain-map correction has limited the DQE(f) at higher exposures with CR. This current work describes a feasible solution to generating plate-specific gain maps. Methods: Ten high-exposure open field images were taken with an RQA5 spectrum, using a sixth generation CR plate suspended in air without a cassette. Image values were converted to exposure, the plates registered using fiducial dots on the plate, the ten images averaged, and then high-pass filtered to remove low frequency contributions from field inhomogeneity. A gain-map was then produced by converting all pixel values in the average into fractions with mean of one. The resultant gain-map of the plate was used to normalize subsequent single images to correct for spatial gain fluctuation. To validate performance, the normalized NPS (NNPS) for all images was calculated both with and without the gain-map correction. Variations in the quality of correction due to exposure levels, beam voltage/spectrum, CR reader used, and registration were investigated. Results: The NNPS with plate-specific gain-map correction showed improvement over the noncorrected case over the range of frequencies from 0.15 to 2.5 mm{sup -1}. At high exposure (40 mR), NNPS was 50%-90% better with gain-map correction than without. A small further improvement in NNPS was seen from carefully registering the gain-map with subsequent images using small fiducial dots, because of slight misregistration during scanning. Further improvement was seen in the NNPS from scaling the gain map about the mean to account for different beam spectra. Conclusions: This study demonstrates that a simple gain-map can be used to correct for the fixed-pattern noise in a given plate and thus improve the DQE of CR imaging. Such a method could easily be implemented by manufacturers because each plate has a unique bar code and the gain-map for all plates associated with a reader could be stored for future retrieval. These experiments indicated that an improvement in NPS (and hence, DQE) is possible, depending on exposure level, over a wide range of frequencies with this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image mosaicing for automated pipe scanning

Remote visual inspection (RVI) is critical for the inspection of the interior condition of pipelines particularly in the nuclear and oil and gas industries. Conventional RVI equipment produces a video which is analysed online by a trained inspector employing expert knowledge. Due to the potentially disorientating nature of the footage, this is a time intensive and difficult activity. In this paper a new probe for such visual inspections is presented. The device employs a catadioptric lens coupled with feature based structure from motion to create a 3D model of the interior surface of a pipeline. Reliance upon the availability of image features is mitigated through orientation and distance estimates from an inertial measurement unit and encoder respectively. Such a model affords a global view of the data thus permitting a greater appreciation of the nature and extent of defects. Furthermore, the technique estimates the 3D position and orientation of the probe thus providing information to direct remedial action. Results are presented for both synthetic and real pipe sections. The former enables the accuracy of the generated model to be assessed while the latter demonstrates the efficacy of the technique in a practice.

42 ENGINEERING↗

Scintillator detector characterization for laser-driven proton beam imaging

The spatial resolution and imaging characteristics of plastic scintillators are characterized using laser-driven proton beams. Laser-driven proton beams typically have broad energy spectra and are accompanied by relativistic electrons and high-energy photons, both potentially contributing to background noise. Different types and thicknesses of Eljen Technology scintillators are compared to determine their intrinsic point spread function. Point-projection imaging of a mesh is used to compare the imaging resolution of the scintillator to the usual imaging detector, radiochromic film, and is found to be reasonably comparable and sufficient for many experimental applications.

47 OTHER INSTRUMENTATION↗

Reconfigurable unitary transformations of optical beam arrays

Spatial transformations of light are ubiquitous in optics, with examples ranging from simple imaging with a lens to quantum and classical information processing in waveguide meshes. Multi-plane light converter (MPLC) systems have emerged as a platform that promises completely general spatial transformations, i.e., a universal unitary. However, until now, MPLC systems have demonstrated transformations that are far from general, e.g., converting from a Gaussian to Laguerre-Gauss mode. Here, we demonstrate the promise of an MLPC, the ability to impose an arbitrary unitary transformation that can be reconfigured dynamically. Specifically, we consider transformations on superpositions of parallel free-space beams arranged in an array, which is a common information encoding in photonics. We experimentally test the full gamut of unitary transformations for a system of two parallel beams and make a map of their fidelity. We obtain an average transformation fidelity of 0.85 ± 0.03. This high-fidelity suggests that MPLCs are a useful tool for implementing the unitary transformations that comprise quantum and classical information processing.

47 OTHER INSTRUMENTATION↗

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)↗

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

Correlative fluorescence microscopy and liquid STEM of proteins labeled with quantum dots on intact cells.

Liquid scanning transmission electron microscopy (liquid STEM) was used to image individual quantum dots bound to receptors in COS7 cells. The same regions on intact fixed cells were imaged both with fluorescence microscopy and liquid STEM. The obtained spatial resolution on was 3 nm. The resolution was sufficient to discriminate between quantum dots and gold nanoparticles for double labeling applications.

59 BASIC BIOLOGICAL SCIENCES↗

X-ray Parametric Down Conversion at an XFEL

Understanding and harnessing X-ray quantum effects could open new frontiers in imaging and quantum optics. In this study, we measured the process of X-ray Parametric Down Conversion, where a single high-energy X-ray photon splits into two lower-energy photons. Using the SACLA X-ray Free Electron Laser in Japan at 9.83 keV, we found clear evidence that pairs of photons were produced along the energy-angle relationship that conserved both energy and momentum, as predicted for down-conversion, and consistent with quantum entanglement of X-ray photons. By matching specific photon pairs for energy and momentum conservation, we observe a signal rate of 1,250 pairs per hour, confirming that correlated photon pairs can be generated and observed in the absence of explicit time correlations. Our results show that with further refinement, the number of entangled photons produced per laser pulse could increase by an order of magnitude. This paves the way for demonstrating quantum-enhanced X-ray imaging, and confirmation of X-ray photon entanglement.

47 OTHER INSTRUMENTATION↗

Computer correction of turbulent distortions of image of extended objects on near-Earth paths

An algorithm of computer-based correction of images of extended objects distorted by turbulent atmosphere is developed. The method of computer correction is used to correct a distorted image of an extended object on a horizontal 2300-m-long observation path. The angular size of the corrected-image region was 15'. (image processing)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Embedded image processing engine using ARM cortex-M4 based STM32F407 microcontroller

Due to advancement in low cost, easily available, yet powerful hardware and revolution in open source software, urge to make newer, more interactive machines and electronic systems have increased manifold among engineers. To make system more interactive, designers need easy to use sensor systems. Giving the boon of vision to machines was never easy, though it is not impossible these days; it is still not easy and expensive. This work presents a low cost, moderate performance and programmable Image processing engine. This Image processing engine is able to capture real time images, can store the images in the permanent storage and can perform preprogrammed image processing operations on the captured images.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monitoring system for the quality assessment in additive manufacturing

Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality and insurance of material security of the complex structure being manufactured. Both, our poster and our oral presentation will explain the data flow between the above mentioned parties involved. A suitable monitoring system for Additive Manufacturing will be introduced, along with a presentation of the respective high resolution data acquisition, as well as the image processing and the data analysis allowing for a precise control of the 3dim growth-process.

36 MATERIALS SCIENCE↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

Optimization of a parallel hole collimator/CdZnTe gamma-camera architecture for scintimammography

Purpose: Small field-of-view CdZnTe (CZT) gamma cameras are increasingly studied for breast lesion detection to complement mammography or ultrasonographic findings. However, in classical collimation configurations, they remain limited by the trade-off between spatial resolution and sensitivity. The HiSens architecture was proposed to overcome these limitations. Using an accurate 3D localization of the interactions inside the detector, this architecture leads to a gain in sensitivity without loss in spatial resolution. In this article, the relevance of the HiSens architecture for planar scintimammography is studied. Methods: A detective quantum efficiency (DQE) computation method is developed and used to optimize the dimensioning of a parallel hole collimator dedicated to scintimammography. Based on the DQE curves, the impact of the collimator-to-detector distance is studied. Two algorithms are proposed to combine data acquired with different collimator-to-detector distances. Results: It is shown that CZT detector virtual pixelization increases system sensitivity by 3.3 while preserving a standard LEHR spatial resolution. The introduction of a gap between the CZT detector and the collimator is useful to modulate the DQE curve shape. The combination of data acquired using different gaps in the image formation process leads to enhanced restoration of the frequency content of the images, resulting in image contrast and spatial resolution improvements. Conclusions: Acquisition duration or injected activity could be markedly reduced if the HiSens architecture with an appropriate collimator-detector gap were used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance fluorescence and quantum interference of a single NV center

The detection of a single nitrogen-vacancy center in diamond has attracted much interest, since it is expected to lead to innovative applications in various domains of quantum information, including quantum metrology, information processing and communications, as well as in various nanotechnologies, such as biological and subdiffraction limit imaging, and tests of entanglement in quantum mechanics. We propose a novel scheme of a single NV center coupled with a multi-mode superconducting microwave cavity driven by coherent fields in squeezed vacuum. We numerically investigate the spectra in-phase quadrature and out-of-phase quadrature for different driving regimes with or without detunings. It shows that the maximum squeezing can be obtained for optimal Rabi fields. Moreover, with the same parameters, the maximum squeezing is greatly increased when the detunings are nonzero compared to the resonance case. - Highlights: • The detection of a single nitrogen-vacancy center in diamond is expected to lead to innovative applications in various domains. • A single NV center coupled with a multi-mode superconducting microwave cavity in squeezed vacuum is proposed. • Numerically investigation of the spectra in-phase quadrature and out-of-phase quadrature are considered. • The maximum squeezing can be obtained for optimal Rabi fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗